Download as pdf or txt
Download as pdf or txt
You are on page 1of 39

Project Job ref.

WWX Debenhams Refurbishment 6685


Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 1/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Steel
Beam Design
Beams
Non-Composite
Rolled
SB 1/10/#22-1/%137

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 3.500 ● 1.000 1.000 1.000 1.000
member 3.500 ● ●
sub-beam 0.160 ● 1.000 1.000 1.000 1.000
support 3.660 ● ● ● ●
Static Design Summary
Summary UB 457x191x67(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 -37.9 839.2 kN 0.045
Pass
Buckling Shear Web - 50.353 58.580 - -
Pass
Moment Major 1 6.0 522.2 kNm 0.012
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.0 - mm - -
Deflection Slab 1 0.0 14.6 mm 0.001
Pass
Deflection Dead 1 0.0 7.3 mm 0.002
Pass
Deflection Imposed 1 0.0 10.2 mm 0.003
Pass
Deflection Total 1 0.1 18.3 mm 0.005
Pass
SB 1/10/#71-1/%165

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 2/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 4.238 ● 1.000 1.000 1.000 1.000
support 4.238 ● ● ● ●
Static Design Summary
Summary UB 457x191x67(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 -73.9 839.2 kN 0.088
Pass
Buckling Shear Web - 50.353 58.580 - -
Pass
Moment Major 1 83.3 522.2 kNm 0.160
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.0 - mm - -
Deflection Slab 1 0.6 17.0 mm 0.033
Pass
Deflection Dead 1 0.5 8.5 mm 0.053
Pass
Deflection Imposed 1 0.9 11.8 mm 0.075
Pass
Deflection Total 1 1.9 21.2 mm 0.092
Pass
SB 1/#15/#16-1/10/#16

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 3/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 2.100 ● 1.000 1.000 1.000 1.000
support 2.100 ● ● ● ●
Static Design Summary
Summary UB 305x165x40(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 -10.1 411.7 kN 0.024
Pass
Buckling Shear Web - 47.167 58.580 - -
Pass
Moment Major 1 4.5 221.2 kNm 0.021
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.0 - mm - -
Deflection Slab 1 0.0 8.4 mm 0.003
Pass
Deflection Dead 1 0.0 4.2 mm 0.005
Pass
Deflection Imposed 1 0.0 5.8 mm 0.008
Pass
Deflection Total 1 0.1 10.5 mm 0.010
Pass
SB 1/%3-1/G/#54

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 4/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 0.300 ● 1.000 1.000 1.000 1.000
member 0.300 ● ●
sub-beam 6.900 ● 1.000 1.000 1.000 1.000
support 7.200 ● ● ● ●
Static Design Summary
Summary UB 457x191x67(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 188.3 839.2 kN 0.224
Pass
Buckling Shear Web - 50.353 58.580 - -
Pass
Moment Major 1 317.0 522.2 kNm 0.607
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.4 - mm - -
Deflection Slab 1 5.9 28.8 mm 0.204
Pass
Deflection Dead 1 4.7 14.4 mm 0.324
Pass
Deflection Imposed 1 9.1 20.0 mm 0.457
Pass
Deflection Total 1 20.1 36.0 mm 0.557
Pass
SB 1/%5-1/G/#55

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 5/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 0.300 ● 1.000 1.000 1.000 1.000
member 0.300 ● ●
sub-beam 3.300 ● 1.000 1.000 1.000 1.000
support 3.600 ● ● ● ●
Static Design Summary
Summary UB 457x191x67(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 84.6 839.2 kN 0.101
Pass
Buckling Shear Web - 50.353 58.580 - -
Pass
Moment Major 1 68.6 522.2 kNm 0.131
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.0 - mm - -
Deflection Slab 1 0.4 14.4 mm 0.024
Pass
Deflection Dead 1 0.3 7.2 mm 0.039
Pass
Deflection Imposed 1 0.5 10.0 mm 0.055
Pass
Deflection Total 1 1.2 18.0 mm 0.067
Pass
SB 1/%60-1/%65

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 6/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 2.959 ● 1.000 1.000 1.000 1.000
member 2.959 ● ●
sub-beam 0.890 ● 1.000 1.000 1.000 1.000
member 3.849 ● ●
sub-beam 1.450 1.000 1.000 1.000 1.000
support 5.299 ● ● ● ●
Static Design Summary
Summary UB 610x229x101(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 -254.6 1369.6 kN 0.186
Pass
Buckling Shear Web - 54.571 58.580 - -
Pass
Moment Major 1 517.7 1021.9 kNm 0.507
Pass
Buckling Lateral Torsional 1 338.5 1021.9 kNm 0.331
Pass
Torsion No Significant Forces Not required
Deflection Self weight 1 0.3 - mm - -
Deflection Slab 1 1.8 21.2 mm 0.084
Pass
Deflection Dead 1 1.4 10.6 mm 0.133
Pass
Deflection Imposed 1 2.8 14.7 mm 0.188
Pass
Deflection Total 1 6.3 26.5 mm 0.236
Pass
SB 1/%60-1/%136

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 7/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
sub-beam 8.201 ● 1.000 1.000 1.000 1.000
member 8.201 ● ●
sub-beam 0.161 ● 1.000 1.000 1.000 1.000
member 8.362 ● ●
sub-beam 0.265 ● 1.000 1.000 1.000 1.000
support 8.627 ● ● ● ●
Static Design Summary
Summary UB 610x229x101(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 -130.0 1369.6 kN 0.095
Pass
Buckling Shear Web - 54.571 58.580 - -
Pass
Moment Major 1 161.6 1021.9 kNm 0.158
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.5 - mm - -
Deflection Slab 1 1.6 34.5 mm 0.045
Pass
Deflection Dead 1 1.2 17.3 mm 0.072
Pass
Deflection Imposed 1 2.4 24.0 mm 0.101
Pass
Deflection Total 1 5.7 43.1 mm 0.132
Pass
SB 1/%65-1/%192

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 2.102 ● 1.000 1.000 1.000 1.000
support 2.102 ● ● ● ●
Static Design Summary
Summary UB 305x165x40(S355)

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 8/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Design Condition # Design Value Design Capacity Units U.R. Status


Classification 1 Class 1 - - -
Pass
Shear Major 1 29.9 411.7 kN 0.073
Pass
Buckling Shear Web - 47.167 58.580 - -
Pass
Moment Major 1 15.7 221.2 kNm 0.071
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.0 - mm - -
Deflection Slab 1 0.1 8.4 mm 0.013
Pass
Deflection Dead 1 0.1 4.2 mm 0.020
Pass
Deflection Imposed 1 0.2 5.8 mm 0.028
Pass
Deflection Total 1 0.4 10.5 mm 0.034
Pass
SB 1/%135-1/%134

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 3.225 ● 1.000 1.000 1.000 1.000
support 3.225 ● ● ● ●
Static Design Summary
Summary UB 305x165x40(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 0.9 411.7 kN 0.002
Pass
Buckling Shear Web - 47.167 58.580 - -
Pass
Moment Major 1 0.7 221.2 kNm 0.003
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.0 - mm - -
Deflection Slab - No loads mm - Not required
Deflection Dead - No loads mm - Not required
Deflection Imposed - No loads mm - Not required
Deflection Total 1 0.0 16.1 mm 0.002
Pass
SB 1/%150-1/%149

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 9/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 4.969 ● 1.000 1.000 1.000 1.000
support 4.969 ● ● ● ●
Static Design Summary
Summary UB 254x146x31(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 37.9 335.5 kN 0.113
Pass
Buckling Shear Web - 39.033 58.580 - -
Pass
Moment Major 1 38.2 139.5 kNm 0.274
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.3 - mm - -
Deflection Slab 1 2.2 19.9 mm 0.110
Pass
Deflection Dead 1 1.7 9.9 mm 0.175
Pass
Deflection Imposed 1 3.4 13.8 mm 0.247
Pass
Deflection Total 1 7.6 24.8 mm 0.306
Pass
SB 1/%152-1/%151

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 5.289 ● 1.000 1.000 1.000 1.000
support 5.289 ● ● ● ●
Static Design Summary
Summary UB 254x146x31(S355)

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 10/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Design Condition # Design Value Design Capacity Units U.R. Status


Classification 1 Class 1 - - -
Pass
Shear Major 1 -1.5 335.5 kN 0.004
Pass
Buckling Shear Web - 39.033 58.580 - -
Pass
Moment Major 1 2.0 139.5 kNm 0.014
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.3 - mm - -
Deflection Slab 1 0.0 21.2 mm 0.002
Pass
Deflection Dead 1 0.0 10.6 mm 0.003
Pass
Deflection Imposed 1 0.1 14.7 mm 0.004
Pass
Deflection Total 1 0.5 26.4 mm 0.018
Pass
SB 1/%160-1/%152

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 3.574 ● 1.000 1.000 1.000 1.000
support 3.574 ● ● ● ●
Static Design Summary
Summary UB 254x146x31(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 0.7 335.5 kN 0.002
Pass
Buckling Shear Web - 39.033 58.580 - -
Pass
Moment Major 1 0.7 139.5 kNm 0.005
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.1 - mm - -
Deflection Slab - No loads mm - Not required
Deflection Dead - No loads mm - Not required
Deflection Imposed - No loads mm - Not required
Deflection Total 1 0.1 17.9 mm 0.004
Pass
SB 1/%162-1/%160

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 11/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 3.600 ● 1.000 1.000 1.000 1.000
support 3.600 ● ● ● ●
Static Design Summary
Summary UB 254x146x31(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 0.7 335.5 kN 0.002
Pass
Buckling Shear Web - 39.033 58.580 - -
Pass
Moment Major 1 0.7 139.5 kNm 0.005
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.1 - mm - -
Deflection Slab - No loads mm - Not required
Deflection Dead - No loads mm - Not required
Deflection Imposed - No loads mm - Not required
Deflection Total 1 0.1 18.0 mm 0.004
Pass
SB 1/%164-1/%162

Restraints

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 12/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 3.241 ● 1.000 1.000 1.000 1.000
support 3.241 ● ● ● ●
Static Design Summary
Summary UB 254x146x31(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 0.7 335.5 kN 0.002
Pass
Buckling Shear Web - 39.033 58.580 - -
Pass
Moment Major 1 0.5 139.5 kNm 0.004
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.1 - mm - -
Deflection Slab - No loads mm - Not required
Deflection Dead - No loads mm - Not required
Deflection Imposed - No loads mm - Not required
Deflection Total 1 0.1 16.2 mm 0.003
Pass
SB 1/%177-1/%173

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 9.999 ● 1.000 1.000 1.000 1.000
support 9.999 ● ● ● ●
Static Design Summary
Summary UB 457x191x74(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 96.7 920.1 kN 0.105
Pass
Buckling Shear Web - 47.556 58.580 - -
Pass
Moment Major 1 289.1 590.4 kNm 0.490
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 1.4 - mm - -
Deflection Slab 1 8.6 40.0 mm 0.215
Pass
Deflection Dead 1 6.8 20.0 mm 0.342
Pass
Deflection Imposed 1 13.4 27.8 mm 0.482
Pass
Deflection Total 1 30.2 50.0 mm 0.604
Pass
SB 1/%192-1/%62

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 13/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 1.550 ● 1.000 1.000 1.000 1.000
member 1.550 ● ●
sub-beam 1.135 ● 1.000 1.000 1.000 1.000
support 2.685 ● ● ● ●
Static Design Summary
Summary UB 305x165x40(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 -59.7 411.7 kN 0.145
Pass
Buckling Shear Web - 47.167 58.580 - -
Pass
Moment Major 1 54.1 221.2 kNm 0.245
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.0 - mm - -
Deflection Slab 1 0.5 10.7 mm 0.046
Pass
Deflection Dead 1 0.4 5.4 mm 0.073
Pass
Deflection Imposed 1 0.8 7.5 mm 0.102
Pass
Deflection Total 1 1.7 13.4 mm 0.126
Pass
SB 1/%208-1/%206

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 3.134 ● 1.000 1.000 1.000 1.000
member 3.134 ● ●
sub-beam 1.900 ● 1.000 1.000 1.000 1.000
support 5.034 ● ● ● ●
Static Design Summary
Summary UB 305x165x40(S355)

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 14/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Design Condition # Design Value Design Capacity Units U.R. Status


Classification 1 Class 1 - - -
Pass
Shear Major 1 -44.7 411.7 kN 0.109
Pass
Buckling Shear Web - 47.167 58.580 - -
Pass
Moment Major 1 46.1 221.2 kNm 0.208
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.2 - mm - -
Deflection Slab 1 1.4 20.1 mm 0.070
Pass
Deflection Dead 1 1.1 10.1 mm 0.112
Pass
Deflection Imposed 1 2.2 14.0 mm 0.158
Pass
Deflection Total 1 5.0 25.2 mm 0.198
Pass
SB 1/%212-1/%222

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 3.134 ● 1.000 1.000 1.000 1.000
support 3.134 ● ● ● ●
Static Design Summary
Summary UB 305x165x40(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 0.8 411.7 kN 0.002
Pass
Buckling Shear Web - 47.167 58.580 - -
Pass
Moment Major 1 0.7 221.2 kNm 0.003
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.0 - mm - -
Deflection Slab - No loads mm - Not required
Deflection Dead - No loads mm - Not required
Deflection Imposed - No loads mm - Not required
Deflection Total 1 0.0 15.7 mm 0.002
Pass
SB 1/%213-1/%218

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 15/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 3.134 ● 1.000 1.000 1.000 1.000
support 3.134 ● ● ● ●
Static Design Summary
Summary UB 305x165x40(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 28.8 411.7 kN 0.070
Pass
Buckling Shear Web - 47.167 58.580 - -
Pass
Moment Major 1 22.6 221.2 kNm 0.102
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.0 - mm - -
Deflection Slab 1 0.3 12.5 mm 0.024
Pass
Deflection Dead 1 0.2 6.3 mm 0.037
Pass
Deflection Imposed 1 0.5 8.7 mm 0.053
Pass
Deflection Total 1 1.0 15.7 mm 0.065
Pass
SB 1/%214-1/G/#55

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 16/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 2.071 ● 1.000 1.000 1.000 1.000
support 2.071 ● ● ● ●
Static Design Summary
Summary UB 457x191x67(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 -30.6 839.2 kN 0.036
Pass
Buckling Shear Web - 50.353 58.580 - -
Pass
Moment Major 1 16.5 522.2 kNm 0.032
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.0 - mm - -
Deflection Slab 1 0.0 8.3 mm 0.004
Pass
Deflection Dead 1 0.0 4.1 mm 0.007
Pass
Deflection Imposed 1 0.1 5.8 mm 0.009
Pass
Deflection Total 1 0.1 10.4 mm 0.012
Pass
SB 1/%218-1/%65

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 17/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 1.900 ● 1.000 1.000 1.000 1.000
support 1.900 ● ● ● ●
Static Design Summary
Summary UC 203x203x46(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 2 - - -
Pass
Shear Major 1 17.6 369.3 kN 0.048
Pass
Buckling Shear Web - 25.167 58.580 - -
Pass
Moment Major 1 8.3 178.1 kNm 0.047
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.0 - mm - -
Deflection Slab 1 0.1 7.6 mm 0.011
Pass
Deflection Dead 1 0.1 3.8 mm 0.017
Pass
Deflection Imposed 1 0.1 5.3 mm 0.024
Pass
Deflection Total 1 0.3 9.5 mm 0.029
Pass
SB 1/%218-1/%221

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 18/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 2.002 ● 1.000 1.000 1.000 1.000
member 2.002 ● ●
sub-beam 0.100 ● 1.000 1.000 1.000 1.000
support 2.102 ● ● ● ●
Static Design Summary
Summary UB 305x165x40(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 -1.3 411.7 kN 0.003
Pass
Buckling Shear Web - 47.167 58.580 - -
Pass
Moment Major 1 0.4 221.2 kNm 0.002
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.0 - mm - -
Deflection Slab 1 0.0 8.4 mm 0.000
Pass
Deflection Dead 1 0.0 4.2 mm 0.000
Pass
Deflection Imposed 1 0.0 5.8 mm 0.000
Pass
Deflection Total 1 0.0 10.5 mm 0.001
Pass
SB 1/%221-1/%192

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 19/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 1.900 ● 1.000 1.000 1.000 1.000
support 1.900 ● ● ● ●
Static Design Summary
Summary UB 305x165x40(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 11.8 411.7 kN 0.029
Pass
Buckling Shear Web - 47.167 58.580 - -
Pass
Moment Major 1 5.6 221.2 kNm 0.025
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.0 - mm - -
Deflection Slab 1 0.0 7.6 mm 0.004
Pass
Deflection Dead 1 0.0 3.8 mm 0.007
Pass
Deflection Imposed 1 0.0 5.3 mm 0.009
Pass
Deflection Total 1 0.1 9.5 mm 0.012
Pass
SB 1/%221-1/%228

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 1.550 ● 1.000 1.000 1.000 1.000
support 1.550 ● ● ● ●
Static Design Summary
Summary UB 305x165x40(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major No Significant Forces kN - Not required
Buckling Shear Web - 47.167 58.580 - -
Pass
Moment Major 1 0.2 221.2 kNm 0.001
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.0 - mm - -
Deflection Slab - No loads mm - Not required
Deflection Dead - No loads mm - Not required
Deflection Imposed - No loads mm - Not required
Deflection Total 1 0.0 7.7 mm 0.000
Pass
SB 1/F/9-1/10/#18
Tekla Structural Designer, version: 23.2.1.1
Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 20/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 0.301 ● 1.000 1.000 1.000 1.000
member 0.301 ● ●
sub-beam 5.801 ● 1.000 1.000 1.000 1.000
member 6.102 ● ●
sub-beam 5.022 ● 1.000 1.000 1.000 1.000
member 11.124 ● ●
sub-beam 0.677 ● 1.000 1.000 1.000 1.000
support 11.801 ● ● ● ●
Static Design Summary
Summary UB 762x267x147(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 368.4 2039.3 kN 0.181
Pass
Buckling Shear Web - 56.172 59.423 - -
Pass
Moment Major 1 1193.2 1778.7 kNm 0.671
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 2.3 - mm - -
Deflection Slab 1 8.8 47.2 mm 0.187
Pass
Deflection Dead 1 7.0 23.6 mm 0.298
Pass
Deflection Imposed 1 13.8 32.8 mm 0.421
Pass
Deflection Total 1 31.9 59.0 mm 0.541
Pass
SB 1/G/#64-1/G/#53

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 0.014 ● 1.000 1.000 1.000 1.000

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 21/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
member 0.014 ● ●
sub-beam 4.611 ● 1.000 1.000 1.000 1.000
member 4.625 ● ●
sub-beam 1.430 ● 1.000 1.000 1.000 1.000
member 6.055 ● ●
sub-beam 3.661 ● 1.000 1.000 1.000 1.000
member 9.716 ● ●
sub-beam 1.373 ● 1.000 1.000 1.000 1.000
support 11.090 ● ● ● ●
Static Design Summary
Summary UB 610x229x113(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 -335.5 1420.2 kN 0.236
Pass
Buckling Shear Web - 51.622 59.423 - -
Pass
Moment Major 1 854.7 1131.9 kNm 0.755
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion - - - - 0.865
Pass
Deflection Self weight 1 2.2 - mm - -
Deflection Slab 1 11.8 44.4 mm 0.267
Pass
Deflection Dead 1 9.4 22.2 mm 0.424
Pass
Deflection Imposed 1 18.4 30.8 mm 0.598
Pass
Deflection Total 1 41.8 55.4 mm 0.755
Pass
Torsion design check applied forces only -
Torsion design check destabilising loads -
SB 1/G/#72-1/%177

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 8.509 ● 1.000 1.000 1.000 1.000
member 8.509 ● ●
sub-beam 2.247 ● 1.000 1.000 1.000 1.000
support 10.756 ● ● ● ●
Static Design Summary
Summary UB 457x191x74(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 -119.8 920.1 kN 0.130
Pass
Buckling Shear Web - 47.556 58.580 - -
Pass
Moment Major 1 332.3 590.4 kNm 0.563
Pass
Buckling Lateral Torsional - - - - - Not required

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 22/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Design Condition # Design Value Design Capacity Units U.R. Status


Torsion No Significant Forces Not required
Deflection Self weight 1 2.8 - mm - -
Deflection Slab 1 11.4 43.0 mm 0.265
Pass
Deflection Dead 1 9.1 21.5 mm 0.421
Pass
Deflection Imposed 1 17.8 29.9 mm 0.594
Pass
Deflection Total 1 41.0 53.8 mm 0.762
Pass
SB 1/G/#74-1/%208

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 1.498 ● 1.000 1.000 1.000 1.000
member 1.498 ● ●
sub-beam 0.842 ● 1.000 1.000 1.000 1.000
member 2.340 ● ●
sub-beam 2.002 ● 1.000 1.000 1.000 1.000
member 4.342 ● ●
sub-beam 1.650 ● 1.000 1.000 1.000 1.000
support 5.992 ● ● ● ●
Static Design Summary
Summary UB 457x191x74(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 66.7 920.1 kN 0.073
Pass
Buckling Shear Web - 47.556 58.580 - -
Pass
Moment Major 1 114.4 590.4 kNm 0.194
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.3 - mm - -
Deflection Slab 1 1.1 24.0 mm 0.047
Pass
Deflection Dead 1 0.9 12.0 mm 0.075
Pass
Deflection Imposed 1 1.8 16.6 mm 0.107
Pass
Deflection Total 1 4.1 30.0 mm 0.137
Pass
SB 1/H/9-1/#15/#16

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 23/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Restraints
Source Distance / LTB Top / LTB Top LTB Btm / LTB Btm Strut Major / Strut Strut Minor / Strut
Length Sub-Beam Factor Sub-Beam Factor Sub-Beam Major Sub-Beam Minor
[m] Factor Factor
support 0.000 ● ● ● ●
sub-beam 0.484 ● 1.000 1.000 1.000 1.000
member 0.484 ● ●
sub-beam 3.468 ● 1.000 1.000 1.000 1.000
member 3.952 ● ●
sub-beam 0.773 ● 1.000 1.000 1.000 1.000
member 4.725 ● ●
sub-beam 0.800 ● 1.000 1.000 1.000 1.000
support 5.525 ● ● ● ●
Static Design Summary
Summary UB 457x191x74(S355)
Design Condition # Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major 1 263.4 920.1 kN 0.286
Pass
Buckling Shear Web - 47.556 58.580 - -
Pass
Moment Major 1 196.6 590.4 kNm 0.333
Pass
Buckling Lateral Torsional - - - - - Not required
Torsion No Significant Forces Not required
Deflection Self weight 1 0.4 - mm - -
Deflection Slab 1 2.0 22.1 mm 0.091
Pass
Deflection Dead 1 1.6 11.1 mm 0.145
Pass
Deflection Imposed 1 3.1 15.3 mm 0.205
Pass
Deflection Total 1 7.1 27.6 mm 0.258
Pass
Beam Design Summary
Static
Member Reference Group Ref. Span Section Grade Length No. Connectors Camber Utilization Status
[m]
SB 1/%213-1/%218 SBR6 1 UB 305x165x40 S355 3.134 0.0 0.102
Pass

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 24/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Member Reference Group Ref. Span Section Grade Length No. Connectors Camber Utilization Status
[m]
SB 1/#15/#16-1/10/#16 SBR35 1 UB 305x165x40 S355 2.100 0.0 0.024
Pass
SB 1/%60-1/%65 SBR32 1 UB 610x229x101 S355 5.299 0.0 0.507
Pass
SB 1/%3-1/G/#54 SBR11 1 UB 457x191x67 S355 7.200 0.0 0.607
Pass
SB 1/%5-1/G/#55 SBR50 1 UB 457x191x67 S355 3.600 0.0 0.131
Pass
SB 1/%218-1/%65 SBR41 1 UC 203x203x46 S355 1.900 0.0 0.048
Pass
SB 1/%60-1/%136 SBR33 1 UB 610x229x101 S355 8.627 0.0 0.158
Pass
SB 1/F/9-1/10/#18 SBR31 1 UB 762x267x147 S355 11.801 0.0 0.671
Pass
SB 1/10/#22-1/%137 SBR23 1 UB 457x191x67 S355 3.660 0.0 0.045
Pass
SB 1/%162-1/%160 SBR50 1 UB 254x146x31 S355 3.600 0.0 0.005
Pass
SB 1/%164-1/%162 SBR69 1 UB 254x146x31 S355 3.241 0.0 0.004
Pass
SB 1/H/9-1/#15/#16 SBR34 1 UB 457x191x74 S355 5.525 0.0 0.333
Pass
SB 1/%160-1/%152 SBR50 1 UB 254x146x31 S355 3.574 0.0 0.005
Pass
SB 1/%152-1/%151 SBR68 1 UB 254x146x31 S355 5.289 0.0 0.018
Pass
SB 1/%221-1/%228 SBR65 1 UB 305x165x40 S355 1.550 0.0 0.001
Pass
SB 1/G/#64-1/G/#53 SBR36 1 UB 610x229x113 S355 11.090 0.0 0.865
Pass
SB 1/%214-1/G/#55 SBR38 1 UB 457x191x67 S355 2.071 0.0 0.036
Pass
SB 1/%221-1/%192 SBR41 1 UB 305x165x40 S355 1.900 0.0 0.029
Pass
SB 1/10/#71-1/%165 SBR58 1 UB 457x191x67 S355 4.238 0.0 0.160
Pass
SB 1/%177-1/%173 SBR59 1 UB 457x191x74 S355 9.999 0.0 0.604
Pass
SB 1/%65-1/%192 SBR42 1 UB 305x165x40 S355 2.102 0.0 0.073
Pass
SB 1/%192-1/%62 SBR64 1 UB 305x165x40 S355 2.685 0.0 0.245
Pass
SB 1/G/#74-1/%208 SBR62 1 UB 457x191x74 S355 5.992 0.0 0.194
Pass
SB 1/%208-1/%206 SBR40 1 UB 305x165x40 S355 5.034 0.0 0.208
Pass
SB 1/%150-1/%149 SBR67 1 UB 254x146x31 S355 4.969 0.0 0.306
Pass
SB 1/%135-1/%134 SBR6 1 UB 305x165x40 S355 3.225 0.0 0.003
Pass
SB 1/G/#72-1/%177 SBR61 1 UB 457x191x74 S355 10.756 0.0 0.762
Pass
SB 1/%218-1/%221 SBR42 1 UB 305x165x40 S355 2.102 0.0 0.003
Pass
SB 1/%212-1/%222 SBR6 1 UB 305x165x40 S355 3.134 0.0 0.003
Pass
Steel
Column Design
Columns
Rolled
SC %96

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 25/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Lateral Restraints
Level Source Distance / Face A restrained / Face A Face C restrained/ Face C
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Strut Restraints
Level Source Distance / Major restrained / Major Minor restrained / Minor
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Static Design Summary
Summary UC 203x203x46(S355)
Design Condition Combination Name Design Value Design Capacity Units U.R. Status
Classification 1 Class 2 - - -
Pass
Shear Major No Significant Forces kN - Not required
Shear Minor No Significant Forces kN - Not required

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 26/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Design Condition Combination Name Design Value Design Capacity Units U.R. Status
Buckling Shear Web - 25.17 58.58 - -
Pass
Moment Major 1 -3.5 178.1 kNm 0.020
Pass
Moment Minor 1 23.3 82.1 kNm 0.284
Pass
Axial 1 305.5 2102.4 kN 0.145
Pass
Axial Bending Combined 1 - - - 0.285
Pass
Buckling Lateral Torsional 1 -3.5 149.7 kNm 0.024
Pass
Buckling Compression 1 305.5 718.5 kN 0.425
Pass
Buckling Combined 1 - - - 0.717
Pass
SC %191

Lateral Restraints
Level Source Distance / Face A restrained / Face A Face C restrained/ Face C
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Strut Restraints

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 27/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Level Source Distance / Major restrained / Major Minor restrained / Minor


Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Static Design Summary
Summary UC 203x203x46(S355)
Design Condition Combination Name Design Value Design Capacity Units U.R. Status
Classification 1 Class 2 - - -
Pass
Shear Major No Significant Forces kN - Not required
Shear Minor No Significant Forces kN - Not required
Buckling Shear Web - 25.17 58.58 - -
Pass
Moment Major 1 -2.4 178.1 kNm 0.013
Pass
Moment Minor 1 -2.8 82.1 kNm 0.034
Pass
Axial 1 102.1 2102.4 kN 0.049
Pass
Axial Bending Combined 1 - - - 0.034
Pass
Buckling Lateral Torsional 1 -2.4 149.7 kNm 0.016
Pass
Buckling Compression 1 102.1 718.5 kN 0.142
Pass
Buckling Combined 1 - - - 0.182
Pass
SC %217

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 28/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Lateral Restraints
Level Source Distance / Face A restrained / Face A Face C restrained/ Face C
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Strut Restraints
Level Source Distance / Major restrained / Major Minor restrained / Minor
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Static Design Summary
Summary UC 203x203x46(S355)
Design Condition Combination Name Design Value Design Capacity Units U.R. Status
Classification 1 Class 2 - - -
Pass
Shear Major No Significant Forces kN - Not required
Shear Minor No Significant Forces kN - Not required

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 29/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Design Condition Combination Name Design Value Design Capacity Units U.R. Status
Buckling Shear Web - 25.17 58.58 - -
Pass
Moment Major 1 -2.3 178.1 kNm 0.013
Pass
Moment Minor No Significant Forces kNm - Not required
Axial 1 50.4 2102.4 kN 0.024
Pass
Axial Bending Combined 1 - - - 0.001
Pass
Buckling Lateral Torsional 1 -2.3 149.7 kNm 0.015
Pass
Buckling Compression 1 50.4 718.5 kN 0.070
Pass
Buckling Combined 1 - - - 0.085
Pass
SC %225

Lateral Restraints
Level Source Distance / Face A restrained / Face A Face C restrained/ Face C
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Strut Restraints

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 30/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Level Source Distance / Major restrained / Major Minor restrained / Minor


Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Static Design Summary
Summary UC 203x203x46(S355)
Design Condition Combination Name Design Value Design Capacity Units U.R. Status
Classification 1 Class 2 - - -
Pass
Shear Major No Significant Forces kN - Not required
Shear Minor No Significant Forces kN - Not required
Buckling Shear Web - 25.17 58.58 - -
Pass
Moment Major 1 2.3 178.1 kNm 0.013
Pass
Moment Minor No Significant Forces kNm - Not required
Axial 1 16.9 2102.4 kN 0.008
Pass
Axial Bending Combined 1 - - - 0.001
Pass
Buckling Lateral Torsional 1 2.3 149.7 kNm 0.016
Pass
Buckling Compression 1 16.9 718.5 kN 0.024
Pass
Buckling Combined 1 - - - 0.040
Pass
Column Design Summary
Static
Member Reference Group Ref. Stack Section Grade Length Utilization Status
[m]
SC %96 SCR7 1 UC 203x203x46 S355 5.550 0.717
Pass
SC %217 SCR7 1 UC 203x203x46 S355 5.550 0.085
Pass
SC %191 SCR7 1 UC 203x203x46 S355 5.550 0.182
Pass
SC %225 SCR7 1 UC 203x203x46 S355 5.550 0.040
Pass
Column Group Design Summary
Static
Reference No. in Group Critical Member Stacks Critical Stack Section Grade Max. UR Status
SCR2 6 SC H/7 1 1 UC 356x368x129 S355 0.461
Pass
SCR3 10 SC %53 1 1 UC 254x254x73 S355 0.078
Warning
SCR7 4 SC %96 1 1 UC 203x203x46 S355 0.717
Pass
Reference Stacks Critical Stack Section Grade Max. UR Status
SC %52 1 1 UC 254x254x89 S355 0.563
Pass
SC %34 1 1 UC 203x203x71 S355 0.760
Pass
SC G/8 1 1 UC 356x368x153 S355 0.403
Pass
SC %52

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 31/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Lateral Restraints
Level Source Distance / Face A restrained / Face A Face C restrained/ Face C
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Strut Restraints
Level Source Distance / Major restrained / Major Minor restrained / Minor
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Static Design Summary
Summary UC 254x254x89(S355)
Design Condition Combination Name Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major No Significant Forces kN - Not required
Shear Minor No Significant Forces kN - Not required
Buckling Shear Web - 21.91 59.42 - -
Pass

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 32/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Design Condition Combination Name Design Value Design Capacity Units U.R. Status
Moment Major 1 -99.8 422.2 kNm 0.236
Pass
Moment Minor 1 -5.5 198.5 kNm 0.028
Pass
Axial 1 578.9 3909.2 kN 0.148
Pass
Axial Bending Combined 1 - - - 0.090
Pass
Buckling Lateral Torsional 1 -99.8 387.6 kNm 0.257
Pass
Buckling Compression 1 578.9 1906.3 kN 0.304
Pass
Buckling Combined 1 - - - 0.563
Pass
SC %34

Lateral Restraints
Level Source Distance / Face A restrained / Face A Face C restrained/ Face C
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Strut Restraints

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 33/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Level Source Distance / Major restrained / Major Minor restrained / Minor


Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Static Design Summary
Summary UC 203x203x71(S355)
Design Condition Combination Name Design Value Design Capacity Units U.R. Status
Classification 1 Class 1 - - -
Pass
Shear Major No Significant Forces kN - Not required
Shear Minor No Significant Forces kN - Not required
Buckling Shear Web - 18.12 59.42 - -
Pass
Moment Major 1 -64.9 275.6 kNm 0.236
Pass
Moment Minor 1 -16.1 128.9 kNm 0.125
Pass
Axial 1 470.8 3119.7 kN 0.151
Pass
Axial Bending Combined 1 - - - 0.188
Pass
Buckling Lateral Torsional 1 -64.9 247.7 kNm 0.262
Pass
Buckling Compression 1 470.8 1147.0 kN 0.410
Pass
Buckling Combined 1 - - - 0.760
Pass
SC G/8

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 34/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Lateral Restraints
Level Source Distance / Face A restrained / Face A Face C restrained/ Face C
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Strut Restraints
Level Source Distance / Major restrained / Major Minor restrained / Minor
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Static Design Summary
Summary UC 356x368x153(S355)
Design Condition Combination Name Design Value Design Capacity Units U.R. Status
Classification 1 Class 2 - - -
Pass
Shear Major No Significant Forces kN - Not required

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 35/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Design Condition Combination Name Design Value Design Capacity Units U.R. Status
Shear Minor No Significant Forces kN - Not required
Buckling Shear Web - 26.07 59.42 - -
Pass
Moment Major 1 -7.6 1022.8 kNm 0.007
Pass
Moment Minor 1 -0.5 495.0 kNm 0.001
Pass
Axial 1 1833.8 6720.7 kN 0.273
Pass
Axial Bending Combined 1 - - - 0.000
Pass
Buckling Lateral Torsional 1 -7.6 993.7 kNm 0.008
Pass
Buckling Compression 1 1833.8 4642.8 kN 0.395
Pass
Buckling Combined 1 - - - 0.403
Pass
SC H/7

Lateral Restraints
Level Source Distance / Face A restrained / Face A Face C restrained/ Face C
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 36/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Level Source Distance / Face A restrained / Face A Face C restrained/ Face C


Length Sub-stack continuous factor Sub-stack continuous factor
1 floor 0.000 Yes Yes
Strut Restraints
Level Source Distance / Major restrained / Major Minor restrained / Minor
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Static Design Summary
Summary UC 356x368x129(S355)
Design Condition Combination Name Design Value Design Capacity Units U.R. Status
Classification 1 Class 3 - - -
Pass
Shear Major No Significant Forces kN - Not required
Shear Minor No Significant Forces kN - Not required
Buckling Shear Web - 30.83 59.42 - -
Pass
Moment Major 1 172.2 780.9 kNm 0.220
Pass
Moment Minor No Significant Forces kNm - Not required
Axial 1 937.9 5669.6 kN 0.165
Pass
Axial Bending Combined 1 - - - 0.384
Pass
Buckling Lateral Torsional 1 172.2 760.7 kNm 0.226
Pass
Buckling Compression 1 937.9 3898.7 kN 0.241
Pass
Buckling Combined 1 - - - 0.461
Pass
SC %53

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 37/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Lateral Restraints
Level Source Distance / Face A restrained / Face A Face C restrained/ Face C
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Strut Restraints
Level Source Distance / Major restrained / Major Minor restrained / Minor
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 No Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Static Design Summary
Summary UC 254x254x73(S355)
Design Condition Combination Name Design Value Design Capacity Units U.R. Status
Classification 1 Class 2 - - -
Pass
Shear Major No Significant Forces kN - Not required
Shear Minor No Significant Forces kN - Not required
Buckling Shear Web - 26.24 58.58 - -
Pass

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 38/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Design Condition Combination Name Design Value Design Capacity Units U.R. Status
Moment Major No Significant Forces kNm - Not required
Moment Minor 1 7.4 165.2 kNm 0.045
Pass
Axial 1 76.5 3305.1 kN 0.023
Pass
Axial Bending Combined 1 - - - 0.045
Pass
Buckling Lateral Torsional No Significant Forces kNm - Not required
Buckling Compression 1 76.5 1563.7 kN 0.049
Pass
Buckling Combined 1 - - - 0.078
Pass
Design Note Major and/or Minor Axes Strut Restrained
Warning
SC %96

Lateral Restraints
Level Source Distance / Face A restrained / Face A Face C restrained/ Face C
Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Strut Restraints

Tekla Structural Designer, version: 23.2.1.1


Project Job ref.
WWX Debenhams Refurbishment 6685
Structure Sheet no.
Slab opening to suit new lift, risers, and risers (GL 8 – 10 / E – I) Page 39/39
Calc. by Date Chk'd by Date App'd by Date
S.pidakala 02/04/2024 M.Furness 02/04/2024 M.Furness 02/04/2024

Level Source Distance / Major restrained / Major Minor restrained / Minor


Length Sub-stack continuous factor Sub-stack continuous factor
2 floor 5.550 Yes Yes
sub-beam 5.550 No 1.000 No 1.000
1 floor 0.000 Yes Yes
Static Design Summary
Summary UC 203x203x46(S355)
Design Condition Combination Name Design Value Design Capacity Units U.R. Status
Classification 1 Class 2 - - -
Pass
Shear Major No Significant Forces kN - Not required
Shear Minor No Significant Forces kN - Not required
Buckling Shear Web - 25.17 58.58 - -
Pass
Moment Major 1 -3.5 178.1 kNm 0.020
Pass
Moment Minor 1 23.3 82.1 kNm 0.284
Pass
Axial 1 305.5 2102.4 kN 0.145
Pass
Axial Bending Combined 1 - - - 0.285
Pass
Buckling Lateral Torsional 1 -3.5 149.7 kNm 0.024
Pass
Buckling Compression 1 305.5 718.5 kN 0.425
Pass
Buckling Combined 1 - - - 0.717
Pass

Tekla Structural Designer, version: 23.2.1.1