Outlite Gas4

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

CAESAR II 2018 Ver.10.00.00.

7700, (Build 170726) Date: FEB 12, 2024 Time: 13:53


Job Name: OUTLITE GAS
Licensed To: SPLM: Edit company name in <system>\company.txt
STRESS SUMMARY REPORT: Highest Stresses Mini Statement
Various Load Cases

LOAD CASE DEFINITION KEY

CASE 2 (OPE) W+T1+P1


CASE 4 (SUS) W+P1

Piping Code: B31.3 = B31.3 -2016, Jan 31, 2017

NO CODE STRESS CHECK PROCESSED: LOADCASE 2 (OPE) W+T1+P1

Highest Stresses: (bars ) LOADCASE 2 (OPE) W+T1+P1


Ratio (%): 0.0 @Node 70
OPE Stress: 1137.3 Allowable Stress: 0.0
Axial Stress: 85.6 @Node 700
Bending Stress: 1117.0 @Node 70
Torsion Stress: 151.1 @Node 540
Hoop Stress: 177.8 @Node 700
Max Stress Intensity: 1270.0 @Node 70

CODE STRESS CHECK PASSED : LOADCASE 4 (SUS) W+P1

Highest Stresses: (bars ) LOADCASE 4 (SUS) W+P1


Ratio (%): 14.8 @Node 510
Code Stress: 204.5 Allowable Stress: 1378.9
Axial Stress: 87.6 @Node 700
Bending Stress: 132.1 @Node 510
Torsion Stress: 8.8 @Node 609
Hoop Stress: 181.8 @Node 700
Max Stress Intensity: 207.3 @Node 510

02/12/24 14:02:48 Page 6