Professional Documents
Culture Documents
Seboba - Sheet - S-1 - Roof Plan and Frames
Seboba - Sheet - S-1 - Roof Plan and Frames
Seboba - Sheet - S-1 - Roof Plan and Frames
A B C D EF G H I J K L M N O P Q RS T U V W
Steel Mast with spike for 3000 3000 3000 3000 533 4885 2096 757 2275 3334
lightning protection, to 605 889 881 877 202676 889 1070 1126 1638 2160 2209 1636 1138 1052 891 668242 867 900 876 607
specialist's detail 1 D F H K M
specifications S.3 S.3 S.3 S.3 S.3
Steel Mast with spike for
lightning protection, to
B specialist's detail
specifications
S.3
FHR
TC1
38 Dia laths
W spaced at 150 c/c
607
A. 36.48° (Typical) 57
V 38 Dia laths
44
36.48°
B1
876
4306
(Typical)
B1
A.
A. 11
A.
FE 8
900
C-1 46 43
4 11 3
P
T A. B1 S.3 C-2 B2
S.1 A. A.
key
668242 867
C-1
FE C-2 B2
S C-1 B1 C-2 B2
R TC1
A.
C-2 56
B2 44 89
Q B1 57 A. A.
A.
A.
891
C-1
12744 12740
P L
A.
A.
1052
A.
ST3
ST3
O
A.
A.
A.
A.
FE
A.
A.
1138
A.
A.
N TC1 FE
A.
A.
A.
A. Level 2
1636
A.
A.
A.
A.
3000
M A.
A.
A.
A.
A.
2209
A.
A.
Lower ground
FE
B.
FE 0
A. A. TC1 A. Level 1
L L TC1 0
2 2
S.2 S.2
FE
A.
2160
2.1 2.1
A.
S.1 S.1
A.
A.
Section 3.
A.
A.
A.
A.
K SCALE 1 : 75
A.
A.
A.
A.
1638
A.
A.
EF G H I J K L M N O P Q RS
A.
A.
A.
J
A.
TC1
A.
1126
A. 202676 889 1070 1126 1638 2160 2209 1636 1138 1052 891 668242
A.
FE
A.
A.
A.
A.
A.
A.
A.
I
A.
1070
A.
A.
A.
FE
H A.
889
FE
A.
C-1 A.
B1 C-2
C-2
G A.
877 202676
C-2
C-1
A. A.
F
E A.
B1 P
FHR B2
TC1
S.3 C-2
C-1 B2
B1 B2 4
D FE A.
V1
S.1
B2
881
C-1 S.3
A.
B1
C
889
A. C-1 KEY
B1
B
605
A
TC1
FE FIRE EXTINGUISHER
A.
TC1
FHR A.
Steel Mast with spike for A E G J L N L
lightning protection, to C FIRE HORSE REEL
S.2 S.3 S.3 S.2 S.3 S.2 A.
specialist's detail S.3
specifications A.
Steel Mast with spike for
lightning protection, to
specialist's detail A. Level 2
specifications Upper Ground
3000
ROOF PLAN A. Level
26172
SCALE 1 : 75 3000
Lower ground
1 2 3 4 5 6 7 8 9 10 11 0
3000 3000 3000 3000 533 4885 2096 757 2275 3334 Level 1
0
1a 2a 3a 4a 6a 6b 6c 7a
Section 4. graphic scale
997 1003 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1010 990 516 SCALE 1 : 75
0M 10 M 50 M 100 M N
ROOF PLAN
38 Dia laths 12900 Location plan
general notes
spaced at 150 c/c
A.
(Typical) 2852 1.Do not scale from this drawing.
A. 2.All dimensions to be checked on site.
B. 3.Report all drawing errors, omissions and discrepancies to the
B.
architect.
4.This document may be issued in an uncontrolled CAD format to
enable others to use it as background information to make
A.
B.
A.
A.
A.
A.
A.
A.
B. B.
A.
client
A.
A.
A.
TC1
A.
B.
A.
B.
1 B.
TC1
B. A. A.
B. B. B.
ST3
ST3
B. B.
B.
B.
TC1
B.
TC1
TC1
B. B.
3 B.
TC1
ST3
S.2
ST3
Upper Ground
TC1
4717
500
Level 2 2617
A.
1300
3000
1800
1800
600 600
job title job location
2917
2917
1500
Footing
(Typical) Lower ground
300
SECTI 2.1
Orapa
1 : 75 S.1
Architect