Power Relay Temperature Test 4

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

DATE : 02.01.

17
DEPT : MLC QUALITY
RELIABILITY TEST REPORT REP NO:MLK/RL/HMSI/0117/03
PAGE : 4 OF 4

1) TEST METHOD : 2) TEST CONDITION :

TEMPERATURE: +80°C FOR 1 HOUR


PLACE THE SAMPLE IN THE THERMOSTATIC CHAMBER AND LOWER THE
TEMPERATURE GRADUALLY FROM NORMAL TEMPERATURE TO +80°C
THEN MEASURE THE VALUES OF THE PARAMETERS MENTIONED BELOW

3) PHOTOS TAKEN DURING THE TEST :

MITSUBA
&
MULTILINK OMRON
POWER POWER
RELAY RELAY

4) OBSERVATION :

A) NO CRACKS OBSERVED ON THE PRODUCT.

B) NO DEFORMATION OBSERVED.

c) NO OTHER FUNCTIONAL ABNORMALITIES OBSERVED.

5) FUNCTIONAL OBSERVATION :

BEFORE TEST AFTER TEST

PARAMETERS SPECIFICATION
SAMPLE 1 SAMPLE 2 SAMPLE 3 SAMPLE 1 SAMPLE 1 SAMPLE 1 SAMPLE 2 SAMPLE 3 SAMPLE 1 SAMPLE 1
(MULTILINK) (MULTILINK) (MULTILINK) (MITSUBA) (OMRON) (MULTILINK) (MULTILINK) (MULTILINK) (MITSUBA) (OMRON)

MINIMUM
OPERATING 8V max 5.7 6.4 6.5 5.8 6.4 6.2 6.4 7.2 6.8 6.4
VOLTAGE

RELEASE
1V-5V 1.4 2.4 1.9 1.6 1.6 3.5 1.5 1.3 4.3 4.1
VOLTAGE

EXCITING
0.2A max 0.142 0.141 0.146 0.143 0.097 0.144 0.141 0.147 0.149 0.106
CURRENT

CONTACT
VOLTAGE 0.2V max 0.12 0.15 0.17 0.15 0.17 0.14 0.17 0.13 0.17 0.15
DROP

RUST & WHITE


COLOUR
APPEARANCE NO PHYSICAL DAMAGE & COLOUR FORMATION OBSERVED NO PHYSICAL DAMAGE & COLOUR FORMATION OBSERVED
FORMATION
NOT ALLOWED