Ramp Footing

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 7

Concrete

Foundation Design Summary


RAMP FOOTING.vfp
Free For ALL
Courtesy of Lavteam.org 22-Apr-24 11:39 PM

Accounting Design Parameters


Project Notes Add Notes Here F'c 27579 kPa
Engineer Free For ALL Fy 413685 kPa
Company Courtesy of Lavteam.org Rebar Layers Top and Bottom
Top Cover 0.0508 m
Concrete Design Criteria Bottom Cover 0.0762 m
Design Provisions ACI 318-11
Outer Bar Direction X
Conc. E Multiplier 1 Rebar Preference #8 @ 0.1 m, #8 @ 0.2 m, #6 @
Load Cases & Combinations 0.3 m, #8 @ 0.15 m, #6 @ 0.3
m, #6 @ 0.2 m, #6 @ 0.3 m, #8
Strength Combinations ULTI
@ 0.2 m
Service Combinations SERVICE
Custom Service Cases 0 Case(s) Design Unit Width Per Foot
Custom Combinations 0 Case(s)
Concrete Detail Information
Safety Factors Bar Pattern 1 : #6 @ 0.3 m 0.00 m^2/Ft.
Strength Uplift
Strength Sliding
1.50
1.50
Minimum Concrete Reinforcement
Minimum Steel Type ACI 7.12.2.1
Strength Overturning 2.00
Service Uplift 1.50 Minimum Steel Ratio 0.001800
Placement Split Top/Bottom
Service Sliding 1.50
Service Overturning 2.00 Design Summary
Reduce Seismic Overturning No Foundation Stable? Yes (unity = 0.21)
Slab Steel OK? Yes (unity = 0.72)
Seismic Criteria Shear Capacity OK? Yes (unity = 0.78)
Redundancy X (ρ) 1
Bearing Pressure OK? Yes (unity = 0.55)
Redundancy Y (ρ) 1
Punching Shear OK? Yes (unity = 0.45)
SDS 0.01
Pile Capacity OK? Yes (unity = 0.00)
SD1 0.01
S1 0.015 Foundation Geometry
Occupancy Category I Area 2.25 m^2
Category (SDC) A Width 1.5 m
Height 1.5 m
Sliding Criteria Volume 0.7875 m^3
Service Force Y 0.0000 kN
Columns 1
Service Force X 0.0000 kN
Strength Force Y 0.0000 kN
Strength Force X 0.0000 kN
Passive Pressure 0.0000 kPa
Friction Coefficient 0.5000

Soil Criteria
Allowable Bearing 200.0000 kPa

Foundation Boundary Information


Footing Material Area Thickness Soil Stiffness Self Weight
Footing 1 Concrete F'c= 27579 2.25 m^2 0.35 m 4800 kN/m^3 Yes
kPa

VisualFoundation 6.0 6.00.0003 1 www.iesweb.com


Foundation Layout
RAMP FOOTING.vfp
Free For ALL
Courtesy of Lavteam.org 22-Apr-24 11:39 PM

VisualFoundation 6.0 6.00.0003 2 www.iesweb.com


Loads and Foundation Components
RAMP FOOTING.vfp
Free For ALL
Courtesy of Lavteam.org 22-Apr-24 11:39 PM

Dependent Load Combinations


Combination Name Building Code Equation Design Type
SERVICE SERVICE D Soil/Service
ULTIMATE ULTI L Footing/Strength

Column Loads
Case Name Location P Mx My Sliding X Sliding Y
L NL4 COL3 -323 kN 0 kN-m 0 kN-m -14. kN -1 kN
D NL2 COL3 -230 kN 0 kN-m 0 kN-m -17 kN -1 kN
SERVICE COL3 -230 kN 0 kN-m 0 kN-m -17 kN -1 kN
ULTIMATE COL3 -323 kN 0 kN-m 0 kN-m -14. kN -1 kN

Columns
Column X Y Type Width/Radius Depth
COL3 0.75 m 0.75 m Rectangle 0.25 m 0.3 m

VisualFoundation 6.0 6.00.0003 3 www.iesweb.com


Stability, Bearing Pressure, and Slab Displacement
RAMP FOOTING.vfp
Free For ALL
Courtesy of Lavteam.org 22-Apr-24 11:39 PM

Bearing Pressure
Maximum

Soil Parameters
Soil Load Combinations SERVICE
Allowable Bearing Pressure 200.0000 kPa

Bearing Pressure
Load Combination Location Pressure Unity Value Average Value
SERVICE (0.75 m, 0.75 m) 110.87 kPa 0.55435 110.47 kPa
SERVICE (0.21875 m, 0.85435 m) 110.48 kPa 0.55241 110.47 kPa

Uplift Stability Sliding


Load Combination Equation Uplift Force Resisting Force Safety Factor Allow. Safety Factor
SERVICE D 0 kN 248.55 kN > 1000 1.5

Stability
Load Equation Sliding Force Resisting Friction Resisting Passive Resisting Safety Factor Allow. Safety
Combination Force Force Additional Force Factor
SERVICE D 17.029 kN 124.28 kN 0 kN 0 kN 7.30 1.5
ULTIMATE L 14.036 kN 161.5 kN 0 kN 0 kN 11.51 1.5

Overturning Stability
Load Combination Equation Side Overturning Resisting Moment Safety Factor Allow. Safety Factor
Moment
SERVICE D V1->V2 (0.75 m, 0 0 kN-m 186.42 kN-m > 1000 2
m)

Z-Displacement
Load Combination Location Z-Displacement
SERVICE (0 m, 1.5 m) -0.02297 m
SERVICE (0.75 m, 0.75 m) -0.0231 m

VisualFoundation 6.0 6.00.0003 4 www.iesweb.com


Concrete Design: Flexure
RAMP FOOTING.vfp
Free For ALL
Courtesy of Lavteam.org 22-Apr-24 11:39 PM

Provided Top Steel Provided Top Steel


X-Direction (steel parallel to X) Y-Direction (steel parallel to Y)

Required Top Steel Required Top Steel


X-Direction (steel parallel to X) Y-Direction (steel parallel to Y)

X Top Steel Check


Location Combination Mu/Ft. ϕ d As Reqd./Ft. As Flex./Ft. As Min./Ft. As Prov./Ft. Unity
(1.4763 m, ULTIMATE 0.03442 kN- 0.90 0.2865 m 0.0001 m^2 0.0000 m^2 0.0001 m^2 0.0003 m^2 0.33139
0.60938 m) m (Min)
(0.04688 m, ULTIMATE 0.00461 kN- 0.90 0.2865 m 0.0001 m^2 0.0000 m^2 0.0001 m^2 0.0003 m^2 0.33139
0.63018 m) m (Min)

Y Top Steel Check


Location Combination Mu/Ft. ϕ d As Reqd./Ft. As Flex./Ft. As Min./Ft. As Prov./Ft. Unity
(0.84375 m, ULTIMATE 0.0266 kN-m 0.90 0.2611 m 0.0001 m^2 0.0000 m^2 0.0001 m^2 0.0003 m^2 0.33139
1.5 m) (Min)
(0.46875 m, ULTIMATE 0.00529 kN- 0.90 0.2611 m 0.0001 0.0000 m^2 0.0001 m^2 0.0003 m^2 0.33139
0 m) m m^2
(Min)

VisualFoundation 6.0 6.00.0003 5 www.iesweb.com


Concrete Design: Flexure
RAMP FOOTING.vfp
Free For ALL
Courtesy of Lavteam.org 22-Apr-24 11:39 PM

Provided Bottom Steel Provided Bottom Steel


X-Direction (steel parallel to X) Y-Direction (steel parallel to Y)

Required Bottom Steel Required Bottom Steel


X-Direction (steel parallel to X) Y-Direction (steel parallel to Y)

X Bottom Steel Check


Location Combination Mu/Ft. ϕ d As Reqd./Ft. As Flex./Ft. As Min./Ft. As Prov./Ft. Unity
(0.7441 m, ULTIMATE 19.589 kN-m 0.90 0.2611 m 0.0002 m^2 0.0002 m^2 0.0001 m^2 0.0003 m^2 0.71181
0.625 m)
(0.21875 m, ULTIMATE 0.74192 kN- 0.90 0.2611 m 0.0001 m^2 0.0000 m^2 0.0001 m^2 0.0003 m^2 0.33139
0.85435 m) m (Min)

Y Bottom Steel Check


Location Combination Mu/Ft. ϕ d As Reqd./Ft. As Flex./Ft. As Min./Ft. As Prov./Ft. Unity
(0.9 m, ULTIMATE 17.794 kN-m 0.90 0.2357 m 0.0002 m^2 0.0002 m^2 0.0001 m^2 0.0003 m^2 0.71822
0.76273 m)
(0.21875 m, ULTIMATE 6.5004 kN-m 0.90 0.2357 m 0.0001 m^2 0.0001 m^2 0.0001 m^2 0.0003 m^2 0.33139
0.85435 m) (Min)

VisualFoundation 6.0 6.00.0003 6 www.iesweb.com


Concrete Design: Shear
RAMP FOOTING.vfp
Free For ALL
Courtesy of Lavteam.org 22-Apr-24 11:39 PM

Shear Factor

Slab Shear Check


Location Case - Vux Vux/Ft. ϕVcx/Ft. Case - Vuy Vuy/Ft. ϕVcy/Ft. Unity Check
(0.80546 m, ULTIMATE 5.7826 kN 52.055 kN ULTIMATE 36.571 kN 46.991 kN 0.77825
0.3893 m)

Column Punching Shear Check


Name Location Perimeter Beta C ϕ Vc Load Case Load Soil-Footing Unity
COL3 Interior 2.0428 m 1.2 0.75 839.84 kN ULTIMATE 323 kN 37.387 kN 0.45344

VisualFoundation 6.0 6.00.0003 7 www.iesweb.com