3. A square footing is shown in the following figure. The footing is subjected to an eccentric
load. Determine the gross allowable load that the footing could carry if γ=19.5 kN/m3,
c’=0, ϕ’=40°, B=3 m, Df=1.4 m and e=0.3 m.
4. Determine the factor of safety against bearing capacity failure of the cantilever gravity
retaining wall shown in the following figure. The existing soil is a clay (γ=20.5 kN/m3,
cu= 48 kPa, c’=9 kPa, ϕ’=23°) and the backfill is a coarse-grained soil. The base of the
wall will rest on a 50 -mm-thick, compacted layer of the backfill. The interface friction
between the base and the compacted layer of backfill is 28°. Groundwater level
is 8 m below the base.