pellet mill line A C_V16_1 / PLC_Pellet A ,C & E [CPU 1515-2 PN] / Program blocks / Data To Scada
Data Send To Scada Line A C E [DB535]
Data Send To Scada Line A C E Properties
General
Name Data Send To Scada Line A C Number 535 Type DB Language DB
E
Numbering Automatic
Information
Title Author Comment Family
Version 0.1 User-defined ID

Data Send To Scada Line A C E


Name Data type Offset Start value Retain Accessi‐ Writ‐ Visible in Setpoint Supervi‐ Comment
ble from able HMI engi‐ sion
HMI/OPC from neering
UA/Web HMI/
API OPC
UA/
Web
API
Static
Actual Amp P02A Real 0.0 0.0 False True True True False
Actual Amp P02C Real 4.0 0.0 False True True True False
Actual Amp P02E Real 8.0 0.0 False True True True False
Actual Amp P08A Real 12.0 0.0 False True True True False
Actual Amp P08C Real 16.0 0.0 False True True True False
Actual Amp P08E Real 20.0 0.0 False True True True False
Actual RPM P04A Real 24.0 0.0 False True True True False
Actual RPM P06A Real 28.0 0.0 False True True True False
Actual RPM P09A2 Real 32.0 0.0 False True True True False
Actual RPM P09A3 Real 36.0 0.0 False True True True False
Actual RPM P04C Real 40.0 0.0 False True True True False
Actual RPM P06C Real 44.0 0.0 False True True True False
Actual RPM P09C2 Real 48.0 0.0 False True True True False
Actual RPM P09C3 Real 52.0 0.0 False True True True False
Actual RPM P04E Real 56.0 0.0 False True True True False
Actual RPM P09E3 Real 60.0 0.0 False True True True False
Actual RPM P09E4 Real 64.0 0.0 False True True True False
Actual Temp P06A Real 68.0 0.0 False True True True False
Actual Temp P07A-1 Real 72.0 0.0 False True True True False
Actual Temp P08A Real 76.0 0.0 False True True True False
Actual Temp P06C Real 80.0 0.0 False True True True False
Actual Temp P07C-1 Real 84.0 0.0 False True True True False
Actual Temp P08C Real 88.0 0.0 False True True True False
Actual Temp P07E Real 92.0 0.0 False True True True False
Actual Temp TE10 Line A Real 96.0 0.0 False True True True False
Actual Temp TE09 Post A Real 100.0 0.0 False True True True False
Actual Temp TE01 Line A Real 104.0 0.0 False True True True False
Actual Temp TE02 Line A Real 108.0 0.0 False True True True False
Actual Temp TE03 Line A Real 112.0 0.0 False True True True False
Actual Temp TE04 Line A Real 116.0 0.0 False True True True False
Actual Temp TE05 Line A Real 120.0 0.0 False True True True False
Actual Temp TE06 Line A Real 124.0 0.0 False True True True False
Actual Temp TE07 Line A Real 128.0 0.0 False True True True False
Actual Temp TE10 Line C Real 132.0 0.0 False True True True False
Actual Temp TE09 Post C Real 136.0 0.0 False True True True False
Actual Temp TE01 Line C Real 140.0 0.0 False True True True False
Actual Temp TE02 Line C Real 144.0 0.0 False True True True False
Actual Temp TE03 Line C Real 148.0 0.0 False True True True False
Actual Temp TE04 Line C Real 152.0 0.0 False True True True False
Actual Temp TE05 Line C Real 156.0 0.0 False True True True False
Actual Temp TE06 Line C Real 160.0 0.0 False True True True False
Actual Temp TE07 Line C Real 164.0 0.0 False True True True False
Actual Temp TE10 Line E Real 168.0 0.0 False True True True False
Actual Temp TE09 Post E Real 172.0 0.0 False True True True False
Actual Temp TE11 Dryer E Real 176.0 0.0 False True True True False
Valve % Steam Line A Real 180.0 0.0 False True True True False
Valve % Steam Line C Real 184.0 0.0 False True True True False
Cmd Pellet Auto Line A Real 188.0 0.0 False True True True False
Cmd Pellet Auto Line C Real 192.0 0.0 False True True True False
Cmd Pellet Auto Line E Real 196.0 0.0 False True True True False
Status Running Line A Array[0..30] of 200.0 False True True True False
Bool
Status Running Line A[0] Bool 200.0 false False True True True False P02A
Status Running Line A[1] Bool 200.1 false False True True True False P04A
Status Running Line A[2] Bool 200.2 false False True True True False P05A
Status Running Line A[3] Bool 200.3 false False True True True False P05A-1
Status Running Line A[4] Bool 200.4 false False True True True False P06A
Status Running Line A[5] Bool 200.5 false False True True True False P07A
Totally Integrated
Automation Portal

Name Data type Offset Start value Retain Accessi‐ Writ‐ Visible in Setpoint Supervi‐ Comment
ble from able HMI engi‐ sion
HMI/OPC from neering
UA/Web HMI/
API OPC
UA/
Web
API
Status Running Line A[6] Bool 200.6 false False True True True False P07A-1
Status Running Line A[7] Bool 200.7 false False True True True False P08A
Status Running Line A[8] Bool 201.0 false False True True True False P09A-1
Status Running Line A[9] Bool 201.1 false False True True True False P09A
Status Running Line A[10] Bool 201.2 false False True True True False P09A2
Status Running Line A[11] Bool 201.3 false False True True True False P09A3
Status Running Line A[12] Bool 201.4 false False True True True False P09A2-1
Status Running Line A[13] Bool 201.5 false False True True True False P09A5
Status Running Line A[14] Bool 201.6 false False True True True False P09A6
Status Running Line A[15] Bool 201.7 false False True True True False P10A1
Status Running Line A[16] Bool 202.0 false False True True True False P11A1
Status Running Line A[17] Bool 202.1 false False True True True False P12A
Status Running Line A[18] Bool 202.2 false False True True True False P14A
Status Running Line A[19] Bool 202.3 false False True True True False P15A
Status Running Line A[20] Bool 202.4 false False True True True False P16A
Status Running Line A[21] Bool 202.5 false False True True True False
Status Running Line A[22] Bool 202.6 false False True True True False
Status Running Line A[23] Bool 202.7 false False True True True False
Status Running Line A[24] Bool 203.0 false False True True True False
Status Running Line A[25] Bool 203.1 false False True True True False
Status Running Line A[26] Bool 203.2 false False True True True False
Status Running Line A[27] Bool 203.3 false False True True True False
Status Running Line A[28] Bool 203.4 false False True True True False
Status Running Line A[29] Bool 203.5 false False True True True False
Status Running Line A[30] Bool 203.6 false False True True True False
Status Running Line C Array[0..30] of 204.0 False True True True False
Bool
Status Running Line C[0] Bool 204.0 false False True True True False
Status Running Line C[1] Bool 204.1 false False True True True False
Status Running Line C[2] Bool 204.2 false False True True True False
Status Running Line C[3] Bool 204.3 false False True True True False
Status Running Line C[4] Bool 204.4 false False True True True False
Status Running Line C[5] Bool 204.5 false False True True True False
Status Running Line C[6] Bool 204.6 false False True True True False
Status Running Line C[7] Bool 204.7 false False True True True False
Status Running Line C[8] Bool 205.0 false False True True True False
Status Running Line C[9] Bool 205.1 false False True True True False
Status Running Line C[10] Bool 205.2 false False True True True False
Status Running Line C[11] Bool 205.3 false False True True True False
Status Running Line C[12] Bool 205.4 false False True True True False
Status Running Line C[13] Bool 205.5 false False True True True False
Status Running Line C[14] Bool 205.6 false False True True True False
Status Running Line C[15] Bool 205.7 false False True True True False
Status Running Line C[16] Bool 206.0 false False True True True False
Status Running Line C[17] Bool 206.1 false False True True True False
Status Running Line C[18] Bool 206.2 false False True True True False
Status Running Line C[19] Bool 206.3 false False True True True False
Status Running Line C[20] Bool 206.4 false False True True True False
Status Running Line C[21] Bool 206.5 false False True True True False
Status Running Line C[22] Bool 206.6 false False True True True False
Status Running Line C[23] Bool 206.7 false False True True True False
Status Running Line C[24] Bool 207.0 false False True True True False
Status Running Line C[25] Bool 207.1 false False True True True False
Status Running Line C[26] Bool 207.2 false False True True True False
Status Running Line C[27] Bool 207.3 false False True True True False
Status Running Line C[28] Bool 207.4 false False True True True False
Status Running Line C[29] Bool 207.5 false False True True True False
Status Running Line C[30] Bool 207.6 false False True True True False
Status Running Line E Array[0..30] of 208.0 False True True True False
Bool
Status Running Line E[0] Bool 208.0 false False True True True False P02E
Status Running Line E[1] Bool 208.1 false False True True True False P04E
Status Running Line E[2] Bool 208.2 false False True True True False P05E
Status Running Line E[3] Bool 208.3 false False True True True False P05E-1
Status Running Line E[4] Bool 208.4 false False True True True False P07E
Status Running Line E[5] Bool 208.5 false False True True True False P08E
Status Running Line E[6] Bool 208.6 false False True True True False P09E-1
Status Running Line E[7] Bool 208.7 false False True True True False P09E
Status Running Line E[8] Bool 209.0 false False True True True False P09E2
Status Running Line E[9] Bool 209.1 false False True True True False P09E4
Status Running Line E[10] Bool 209.2 false False True True True False DE01
Status Running Line E[11] Bool 209.3 false False True True True False DE02
Status Running Line E[12] Bool 209.4 false False True True True False P09E5
Status Running Line E[13] Bool 209.5 false False True True True False P09E6
Totally Integrated
Automation Portal

Name Data type Offset Start value Retain Accessi‐ Writ‐ Visible in Setpoint Supervi‐ Comment
ble from able HMI engi‐ sion
HMI/OPC from neering
UA/Web HMI/
API OPC
UA/
Web
API
Status Running Line E[14] Bool 209.6 false False True True True False P10E1
Status Running Line E[15] Bool 209.7 false False True True True False P10E
Status Running Line E[16] Bool 210.0 false False True True True False P11E1
Status Running Line E[17] Bool 210.1 false False True True True False P12E
Status Running Line E[18] Bool 210.2 false False True True True False P14E
Status Running Line E[19] Bool 210.3 false False True True True False P16E
Status Running Line E[20] Bool 210.4 false False True True True False
Status Running Line E[21] Bool 210.5 false False True True True False
Status Running Line E[22] Bool 210.6 false False True True True False
Status Running Line E[23] Bool 210.7 false False True True True False
Status Running Line E[24] Bool 211.0 false False True True True False
Status Running Line E[25] Bool 211.1 false False True True True False
Status Running Line E[26] Bool 211.2 false False True True True False
Status Running Line E[27] Bool 211.3 false False True True True False
Status Running Line E[28] Bool 211.4 false False True True True False
Status Running Line E[29] Bool 211.5 false False True True True False
Status Running Line E[30] Bool 211.6 false False True True True False