The OTN service mapping consists of two stages: service signals mapped into
ODUk signals; ODUk signals multiplexed and encapsulated into OTUk signals.

3.1 Client-Side Signals Mapped into ODUk Signals


Huawei OptiXtrans DC908 can map client-side services into ODUk signals in
standard mode.
3.2 ODUk Signals Mapped and Multiplexed into OTUk Signals
ODUk signals are mapped, multiplexed, and encapsulated into OTUk signals. The
electrical OTUk signals are then converted into optical signals and transmitted to
the WDM side of the OTN network. This topic describes the ODUk-to-OTUk
mapping and multiplexing paths supported by the equipment.

3.1 Client-Side Signals Mapped into ODUk Signals


Huawei OptiXtrans DC908 can map client-side services into ODUk signals in
standard mode.

In standard mode, it directly maps client-side services into ODUk signals to


achieve flexible service grooming. Figure 3-1 shows an example.

Figure 3-1 Client-side services mapped into ODUk signals

Different types of client-side services occupy different numbers of timeslots when


they are mapped into ODUflex signals in standard mode. The following table lists
the number of timeslots occupied by each service type.

Issue 08 (2023-09-30) Copyright © Huawei Technologies Co., Ltd. 11


OptiXtrans DC908
Product Description 3 Service Mapping

Service Type Number of Timeslots Occupieda


(Bandwidth: 1.25 Gbit/s)

FC100 1

FC200 2

FC400 4

FICON 8G 7

FC800 7

STM-64 8

OTU2 9

OTU2E 9

FC1600 12

FC3200 23

GE 1

25GE 20

40GE 33

OTU4 90

10GE LAN Manually calculated based on the


service rate.

10GE WAN Manually calculated based on the


service rate.

100GE Manually calculated based on the


service rate.

400GE Manually calculated based on the


service rate.

NOTE

a: The number of timeslots is a rounded-up integer of the rate of the service type divided by the
bandwidth of each timeslot (1.25 Gbit/s). If the result is not an integer, add 1 to the exact
division result. For example, when FC800 services are accessed, the number of timeslots is 7 (6 +
1), because (8.5 Gbit/s)/(1.25 Gbit/s) = 6.8.

3.2 ODUk Signals Mapped and Multiplexed into OTUk


Signals
ODUk signals are mapped, multiplexed, and encapsulated into OTUk signals. The
electrical OTUk signals are then converted into optical signals and transmitted to

Issue 08 (2023-09-30) Copyright © Huawei Technologies Co., Ltd. 12


OptiXtrans DC908
Product Description 3 Service Mapping

the WDM side of the OTN network. This topic describes the ODUk-to-OTUk
mapping and multiplexing paths supported by the equipment.
Huawei OptiXtrans DC908 maps client-side signals into ODU0/ODU2/ODU2e/
ODUflex/ODU3/ODU4 signals, which are further multiplexed and mapped into
OTU4/OTUC2/OTUC3/OTUC4/OTUC6/OTUC8 signals for transmission over fibers.
Figure 3-2 shows the OTN mapping and multiplexing structure supported by
Huawei OptiXtrans DC908.

NOTE

The ODUk rates are approximately 1,244,160 kbit/s(ODU0), 2,498,775.126 kbit/s (ODU1),
10,037,273.924 kbit/s (ODU2), 40,319,218.983 kbit/s (ODU3), 10,399,525.316 kbit/s
(ODU2e), and 104,794,445.815 kbit/s (ODU4).
The ODUCn rate is approximately n x 105,725,952.000 kbit/s.

NOTE

The OTUk rates are approximately 2,666,057.143 kbit/s (OTU1), 10,709,225.316 kbit/s
(OTU2), 43,018,413.559 kbit/s (OTU3), and 111,809,973.568 kbit/s (OTU4).
The OTUCn rate is approximately n x 105,725,952.000 kbit/s.

Figure 3-2 OTN mapping and multiplexing structure

Issue 08 (2023-09-30) Copyright © Huawei Technologies Co., Ltd. 13


OptiXtrans DC908
Product Description 3 Service Mapping

NOTE

TDU is short for Transcode Data Unit.