Q64ad-Gh (HW) en

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1. Overview 4. Precautions for Use 5.

3 Switch setting for intelligent functional module


The settings for the intelligent function module are performed using the I/O
This manual describes the specifications and part names for the type Q64AD-GH (1) Do not drop or apply strong shock to the module. assignment settings for the GX Developer.
Q64AD-GH Channel Isolated High Resolution channel isolated high resolution analog-digital converter module (hereinafter (2) Do not remove the PCB of the module from its case. It can be easy to set by inputting in hexadecimal-4 digits.
Analog-Digital Converter Module Q64AD-GH) to be used in combination with the MELSEC-Q Series CPU module. Doing so may cause the module to fail. Setting item

Thank you for buying the Mitsubishi programmable controller MELSEC Q 2. Specifications (3) Prevent foreign matter such as dust or wire chips from entering the module.
Such foreign matter can cause a fire, failure, or malfunction.
Analog input range Input range setting value
4 to 20mA 0H
Series. The specifications for the Q64AD-GH are shown in the following table. For general (4) A protective film is attached to the top of the module to prevent foreign matter, such 0 to 20mA 1H
specifications for the Q64AD-GH, refer to the operation manual for the CPU module as wire chips, from entering the module during wiring.
Prior to use, please read both this manual and detailed manual thoroughly 1 to 5V 2H
being used. Do not remove the film during wiring. 0 to 5V 3H
and familiarize yourself with the product. Model name
Item
Q64AD-GH Remove it for heat dissipation before system operation. Input range setting – 10 to 10V 4H
(5) Before touching the module, always touch grounded metal, etc. to discharge static
User's Manual Number of analog input
points
4 points (4 channels)
-10 to 10VDC (Input resistance 1 M Ω)
electricity from human body, etc.
Switch 1
H
0 to 10V
4 to 20mA
5H
AH
(Hardware) Analog
input
Voltage
Current 0 to 20mADC (Input resistance 250 Ω) Not doing so can cause the module to fail or malfunction. CH4 CH3 CH2 CH1 (Expanded mode)
1 to 5V
Digital output
16-bit signed binary (-32768 to 32767) (6) Tighten the terminal screws using torque within the following ranges. Loose screws (Expanded mode) CH
32-bit signed binary (-65536 to 65535)
MODEL Q-A/D-GH-U-HW may cause short circuits, mechanical failures or malfunctions. User range setting
Analog input Maximum resolution Digital output Digital output EH
Input Screw location Tightening torque range (Uni-polar)
MODEL range 32-bit 16-bit value (32-bit) value (16-bit)
13JT82 Module fixing screw (M3 screw) 0.36 to 0.48 N · m User range setting FH
Code 0 to 10V 156.3μV 312.6μV
(Bi-polar)
0 to 5V 78.2μV 156.4μV 0 to 64000 0 to 32000 Terminal block terminal screw (M3 screw) 0.42 to 0.58 N · m
IB-0800223-D (0810) MEE 1 to 5V 62.5μV 125.0μV Switch 2 Empty
©2002 MITSUBISHI ELECTRIC CORPORATION 1 to 5V -16000 to Terminal block mounting screw (M3.5 screw) 0.66 to 0.89 N · m
62.5μV - - Switch 3 Empty
(Expanded mode) 72000
5. Wiring
Voltage
Users input range
I/O characteristics, 47.4μV 94.8μV 0 to 64000 0 to 32000
(Uni-polar) H
SAFETY PRECAUTIONS maximum resolution -10 to 10V
Users input range
156.3μV 312.6μV
-64000 to
64000
-32000 to
32000 5.1 Wiring precautions 000H Fixed
(Bi-polar)
47.4μV 94.8μV Switch 4
(Read these precautions before using.) 0 to 20mA 312.5nA 625.0μV
0H : Normal mode
0 to 64000 0 to 32000 (1) Use separate cables for the AC control circuit and the external input signals of the (A/D conversion processing)
When using Mitsubishi equipment, thoroughly read this manual and the related manuals 4 to 20mA 250.0nA 500.0μV
Q64AD-GH to avoid the influence of the AC side surges and inductions. 1H to FH (numeric value other than 0H) *
4 to 20mA -16000 to : Offset/gain setting mode
introduced in the manual. Also pay careful attention to safety and handle the module Current
(Expanded mode)
250.0nA -
72000
-
(2) Perform an one-point grounding for shielded lines and the shields of sealed cables.
correctly. Users input range Switch 5 0H : Fixed
151.6nA 303.2μV 0 to 64000 0 to 32000 (3) Do not mount the cables close to or bundle them with the main circuit line, a
These precautions apply only to this product. Refer to the user’s manual of the CPU (Uni-polar) * Setting any value within the setting range will provide the same operation.
highvoltage cable or a load cable from other than the programmable controller. This When the setting range is 1H to FH, set 1H for example.
module to use for the programmable cntroller system safety precautions. Accuracy
Reference
±0.05%
(Accuracy Digital output value (32-bit) : ±32digit
*2
may increase the effects of noise, surges and induction.
These SAFETY PRECAUTIONS classify the safety precautions into two categories:
"DANGER" and "CAUTION".
relative to
digital
accuracy *1
Digital output value (16-bit) : ±16digit *2
(4) Perform an one-point grounding for shielded lines and the shields of sealed cables. 6. External Dimensions
Temperature
output
coefficient *3
±71.4ppm/°C (0.00714%/°C) (5) A solderless terminal with insulating sleeve cannot be used for the terminal block. Q64AD-GH
value)
Procedures which may lead to a dangerous condition and Common mode Common mode voltage Input-Common ground (input voltage 0V): 1780VAC
Covering the cable-connection portion of the solderless terminal with a marked tube RUN

ERR.
ALM

DANGER cause death or serious injury if not carried out correctly. characteristic Common mode voltage rejection ratio (VCM < 1780V): 60Hz 105dB, 50Hz 107dB or an insulation tube is recommended.
Conversion speed 10ms/4 channels
Procedures which may lead to a dangerous condition and Absolute maximum input Voltage: ± 15V Current: ± 30mA *4 5.2 External wiring V+
1

CAUTION
2

cause superficial to medium injury, or physical damage only, if Specific isolated area
Isolation Dielectric withstand Insulation (1) For voltage input
C V-
H
1 I+
3
4
method voltage resistance
not carried out correctly.

98 (3.86)
Signal source 0 to ±10V
SLD
5
Between I/O terminal V+
6

Isolation specifications Photocoupler *2


C V-
and programmable 500VDC H 7

Depending on circumstances, procedures indicated by CAUTION may also cause controller power supply
insulation 1780VAC rms/3 cycles
10MΩ or *1 500k +
2
SLD
I+
8

(elevation 2000m) 9
serious accidents. Between analog input Transformer more V+ C V-
H
V+
10

In any case, it is important to follow the directions for usage. channels isolation 3 I+ 11
SLD 12

Maximum number of writes I+


Store this manual in a safe place and read it whenever necessary. Always forward it to the Maximum 100,000 C V-
V+ 13

for E2PROM H 14

end user. Number of I/O occupied


GND V-
4
SLD
I+
15

16 points (I/O assignment: Intelligent 16 points) 16


points Shielded 500k -
[DESIGN PRECAUTIONS] A/D 17

Connected terminal 18 points terminal block SLD -10~10V


0~ 20mA
18

CAUTION Applicable wire size 0.3 to 0.75mm2


Applicable solderless
• Do not bunch the control wires or communication cables with the main circuit or power wires, or R1.25 - 3 (Solderless terminals with sleeves are not applicable) *4 90 (3.54) 22 (0.87) 27.4 (1.08)
terminals
install them close to each other. Internal current consumption
0.89A
They should be installed 100 mm (3.94 inch) or more from each other. (5VDC) unit (mm (in.))
Otherwise, noise may occur and result in malfunction. Weight 0.20kg

[INSTALLATION PRECAUTIONS] (2) For current input


*1: Accuracy of offset/gain setting at ambient temperature
CAUTION *2: “digit” indicates a digital output value. Signal source 0 to 20mA Warranty
*3: Accuracy per temperature change of 1 °C *2 Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi;
• Use the programmable controller in an environment that meets the general specifications given in Example: Accuracy when temperature changes from 25 to 30 °C *3 500k + machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage,
the User's Manual of the CPU module being used. 0.05% (reference accuracy) + 0.00714 %/°C (temperature coefficient) x 5 °C (temperature change
*1 V+ accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other
Using this programmable controller in an environment outside the range of the general specifications than Mitsubishi products; and to other duties.
difference) = 0.0857%
may cause electric shock, fire, malfunction, and damage to or deterioration of the product. I+
• To mount the module, while pressing the module mounting lever located in the lower part of the
*4: Current value indicates value of instant input current that does not break module inner electrical resistance.
250 For safe use
module, fully insert the module fixing projection(s) into the hole(s) in the base unit and press the V- This product has been manufactured as a general-purpose part for general industries, and has not been
module until it snaps into place. Incorrect mounting may cause malfunction, failure or drop of the
module. When using the programmable controller in an environment of frequent vibrations, fix the
3. Part Identification Nomenclature GND
Shielded
SLD
500k - designed or manufactured to be incorporated in a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine
module with a screw. This section explains the part names for the Q64AD-GH. or passenger movement vehicles, consult with Mitsubishi.
If the screws are loose, it may cause the module to fallout, short circuits, or malfunction. *4 This product has been manufactured under strict quality control. However, when installing the product
If the screws are tightened too much, it may cause damage to the screw and/or the module, Terminal number Signal name *1 Use a 2-core twisted shielded wire for the power wire. where major accidents or losses could occur if the product fails, install appropriate backup or failsafe
resulting in fallout, short circuits or malfunction. 1) Q64AD-GH 3) functions in the system.
1 Empty *2 Shows input resistance.
• Switch all phases of the external power supply off when mounting or removing the module. RUN ALM

ERR.
2 Empty *3 For current input, be sure to connect to (V+) and (I+) terminals.
Otherwise, the module may be damaged. 2) *4 Be sure to ground the shield wire of each channel.
Country/Region Sales office/Tel Country/Region Sales office/Tel
• Do not directly touch the conductive area or electronic components of the module. 3 V+ U.S.A Mitsubishi Electric Automation Inc. Hong Kong Mitsubishi Electric Automation
The SLD terminal can be used when grounding, however it has not been wired inside the board. Ground 500 Corporate Woods Parkway Vernon (Hong Kong) Ltd.
Otherwise, the module may malfunction or go down. 4 V– it as shown in the diagram shown above or below. Hills, IL 60061, U.S.A. 10th Floor, Manulife Tower, 169 Electric
1 CH1
5 I+ In addition, ground the FG of the power supply module. Tel : +1-847-478-2100 Road, North Point, Hong Kong
[WIRING PRECAUTIONS] V+ 2
Brazil MELCO-TEC Rep. Com.e Assessoria Tel : +852-2887-8870
C V-
3 6 SLD V+ China Mitsubishi Electric Automation
CAUTION H
1 I+ 4
Tecnica Ltda.
(Shanghai) Ltd.
SLD 7 V+ Rua Correia Dias, 184,
4/F Zhi Fu Plazz, No.80 Xin Chang Road,
• When turning on the power and operating the module after wiring is completed, always attach the V+
5
6 8 V– I+ Edificio Paraiso Trade Center-8 andar
Shanghai 200003, China
terminal cover included with the product. C V-
H 7
CH2 Paraiso, Sao Paulo, SP Brazil Tel : +86-21-6120-0808
There is a risk of electric shock if the terminal cover is not attached. 2 I+ 9 I+ V- Tel : +55-11-5908-8331 Taiwan Setsuyo Enterprise Co., Ltd.
8
SLD Germany Mitsubishi Electric Europe B.V. German 6F No.105 Wu-Kung 3rd.Rd, Wu-Ku
• Tighten the terminal screws within the range of specified torque. 9 10 SLD Shielded
Branch
V+
SLD Hsiang, Taipei Hsine, Taiwan
If the terminal screws are loose, it may result in short circuits or malfunction. C V-
H
10
11 V+ Gothaer Strasse 8 D-40880 Ratingen, Tel : +886-2-2299-2499
If the terminal screws are tightened too much, it may cause damage to the screw and/or the 3 I+ 11
12 V– GERMANY Korea Mitsubishi Electric Automation Korea
module, resulting in short circuits or malfunction. SLD 12
CH3 Tel : +49-2102-486-0 Co., Ltd.
• Use applicable solderless terminals and tighten them within the specified torque range. C V-
V+ 13 13 I+ U.K Mitsubishi Electric Europe B.V. UK 1480-6, Gayang-dong, Gangseo-ku
H 14 Branch Seoul 157-200, Korea
If any spade solderless terminal is used, it may be disconnected when the terminal screw comes 4 I+
15 14 SLD Travellers Lane, Hatfield, Hertfordshire., Tel : +82-2-3660-9552
loose, resulting in failure. SLD
16 15 V+ AL10 8XB, U.K. Singapore Mitsubishi Electric Asia Pte, Ltd.
• Be careful not to let foreign matters such as sawdust or wire chips get inside the module. 17 Tel : +44-1707-276100 307 Alexandra Road #05-01/02,
A/D
16 V– Mitsubishi Electric Building,
These may cause fires, failure or malfunction. Italy Mitsubishi Electric Europe B.V. Italian
-10~10V
0~20mA
18
CH4 Singapore 159943
• The top surface of the module is covered with protective film to prevent foreign objects such as 17 I+ Branch Tel : +65-6470-2460
Centro Dir. Colleoni, Pal. Perseo-Ingr.2
cable offcuts from entering the module when wiring. 18 SLD Via Paracelso 12, I-20041 Agrate Brianza.,
Thailand Mitsubishi Electric Automation (Thailand)
Co., Ltd.
Do not remove this film until the wiring is complete. Number Name Description Milano, Italy Bang-Chan Industrial Estate No.111
Before operating the system, be sure to remove the film to provide adequate heat ventilation. Tel : +39-039-60531 Moo 4, Serithai Rd, T.Kannayao,
1) RUN LED Displays the operating status of the Q64AD-GH. Spain Mitsubishi Electric Europe B.V. Spanish A.Kannayao, Bangkok 10230 Thailand
ABOUT MANUAL On : Normal operation Branch Tel : +66-2-517-1326
The following manual is also related to this product. If necessary, order it by quoting the details in the Flickering : During offset/gain setting mode Carretera de Rubi 76-80, Indonesia P.T. Autoteknindo Sumber Makmur
E-08190 Sant Cugat del Valles, Muara Karang Selatan, Block A/Utara
table below. Off : 5V power supply interrupted, watch dog timer error or module
No.1 Kav. No.11 Kawasan Industri
Barcelona, Spain
exchangeable status during online module replacement
Related Manual Tel : +34-93-565-3131 Pergudangan Jakarta - Utara 14440,
2) ERR. LED Displays the error status of the Q64AD-GH. France Mitsubishi Electric Europe B.V. French P.O.Box 5045 Jakarta, 11050 Indonesia
Manual name Manual No. (Model code) On : Error (A/D conversion continues.) Branch Tel : +62-21-6630833
India Messung Systems Pvt, Ltd.
Channel Isolated High Resolution Analog-Digital Converter SH-080277 Flickering : Error (A/D conversion stops.) 25, Boulevard des Bouvets, F-92741
Electronic Sadan NO:III Unit No15,
Module/Channel Isolated High Resolution Analog-Digital Converter Off : Normal operation Nanterre Cedex, France M.I.D.C Bhosari, Pune-411026, India
Module (with signal conditioning function) User’s Manual (13JR51) TEL: +33-1-5568-5568 Tel : +91-20-2712-3130
3) ALM LED Displays the warning status of the Q64AD-GH. South Africa Circuit Breaker Industries Ltd. Australia Mitsubishi Electric Australia Pty. Ltd.
Compliance with the EMC and Low Voltage Directives On : An alarm (process alarm, rate alarm) is being generated. Private Bag 2016, ZA-1600 Isando, 348 Victoria Road, Rydalmere,
Flickering : An input signal error is being generated. South Africa N.S.W 2116, Australia
(1) For programmable controller system Off : Normal operation Tel : +27-11-928-2000 Tel : +61-2-9684-7777
To configure a system meeting the requirements of the EMC and Low Voltage
Directives when incorporating the Mitsubishi programmable controller (EMC and Low Voltage
Directives compliant) into other machinery or equipment, refer to Chapter 9 "EMC AND LOW HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
VOLTAGE DIRECTIVES" of the QCPU User's Manual (Hardware Design, Maintenance and NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN

Inspection).
The CE mark, indicating compliance with the EMC and Low Voltage Directives, is printed on When exported from Japan, this manual does not require application to the Ministry
the rating plate of the programmable controller. of Economy, Trade and Industry for service transaction permission.
(2) For the product
No additional measures are necessary for the compliance of this product with the EMC and Specifications subject to change without notice.
Low Voltage Directives. Printed in Japan on recycled paper.