Parameter
Location: Ethiopia, Awassa (7° North; 38° East) Water temperature: 25 °C
Required daily output: 403 m³; Sizing for July Dirt loss: 5.0 % Motor cable: 200 m
Pipe type: - Total dynamic head: 350 m Pipe length: -
Output [m³]
Energy [kWh] 63 64 60 54 51 46 42 45 53 59 65 65 56
Irradiation [kWh/m²] 6.8 6.9 6.5 5.8 5.4 4.9 4.4 4.7 5.6 6.3 7.0 7.0 6.0
Rainfall [mm] 1.0 1.5 2.6 3.3 3.8 3.3 4.7 5.0 4.3 2.3 0.70 0.47 2.8
Ambient temp. [°C] 18 20 20 20 18 17 16 16 16 17 17 18 18
Hourly values 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00
Output [m³/h]
Energy [kWh] 0.15 1.3 2.7 4.0 4.9 5.5 5.6 5.4 4.8 3.9 2.6 1.2 0.15
Irradiation [kWh/m²] 0.015 0.12 0.27 0.41 0.51 0.58 0.60 0.58 0.51 0.41 0.27 0.12 0.015
Ambient temp. [°C] 11 11 12 14 16 18 20 21 21 21 21 20 20
System characteristic
Wiring diagram
System Layout
Sizing Layout
H (Static head): Vertical height from the dynamic water level to the highest point of delivery.
B (Drawdown): Lowering of water level depending on flow rate and recovery rate of the well.
D (Pipeline inner diameter)
L (Pipe length): Entire pipeline from the pump outlet to the point of delivery. Ellbows and armatures must be added as an
equivalent length of pipeline.
M (Motor cable): The cable between controller and pump unit.
T (Tilt angle): Angle of the PV generator surface from the horizontal plane.
System Overview
Head max. 450 m
Flow rate max. 0.92 m³/h
Technical Data
Controller PS2-4000
ƒControlling and monitoring
ƒControl inputs for dry running protection, remote control etc.
ƒProtected against reverse polarity, overload and overtemperature
ƒIntegrated MPPT (Maximum Power Point Tracking)
ƒIntegrated Sun Sensor
Standards
2006/42/EC, 2004/108/EC, 2006/95/EC
The logos shown reflect the approvals that have been granted for this product family. Products are ordered and supplied with the approvals specific to the market
requirements.
**Vmp: MPP-voltage under Standard Test Conditions (STC): 1000 W/m² solar irradiance, 25 °C cell temperature
***Specify temperature range on order
H1 = 352 mm A= 1,130 mm
H2 = 333 mm B= 265 mm
W1 = 207 mm C= 865 mm
W2 = 170 mm D= 96 mm
W3 = 164 mm E= 147 mm
D1 = 124 mm S= 1.25 in
Net weight
Controller 6.1 kg
Pump Unit 14 kg
Motor 10 kg
Pump End 4.4 kg
*Vmp: MPP-voltage under Standard Test Conditions (STC): 1000 W/m² solar irradiance, 25 °C cell temperature
Order Information
Item no.: 19-000005 Product name: Well probe sensor V2
Features
Reliable dry run protection
Simple to install using 3 cable ties
Improved tolerance to dirt
Splicing kit and cable ties for fixing are included
Technical Data
Max. operating temperature 55°C
Enclosure class: IP68
Submersion depth: max 50 m (164 ft)
Cable length: 1.5 m
Wire size: 2 x 0.50 mm² or AWG 20, waterproofed
Must be mounted in a vertical position
Meets the requirements for CE
Dimensions / Weight
Packaging dimensions: 255 x 170 x 40 mm
10.0 x 6.7 x 1.6 in
Total weight: 0.1 kg / 0.2 lbs
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
Float Switch
Mechanically Activated Device for Water Level Detection in Applications
with LORENTZ Solar Pump Systems
The switch can be used to detect the water level within a tank. When the water level in the tank
reaches the maximum, the LORENTZ Controller will stop the pump and indicates Tank Full LED.
ORDER INFORMATION
• Item no.: 19-000030 product name: Float Switch
FEATURES
• N.O. (normally open) and N.C. (normally closed) function
• Reliable water level detection
• Simple to install
• Trouble free operation
• Not sensitive to rotation
• Corrosion-free
TECHNICAL DATA
• Operating temperature: -10°C to 55°C
• Storage temperature: : -10°C to 55°C
• Enclosure class: IP68
• Cable length: 3m, waterproof
• Wire size: 3x 1.0mm² or AWG 18
• Meets the requirements for CE
DIMENSION/WEIGHT
• Packaging dimensions: 230 x 160 x 55 mm
9.1 x 6.3 x 2.2 in
• Total weight: 0.8 kg / 1.8 lbs
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
Pressure Switch
Device for Water Pressure Detection in Applications with LORENTZ Solar
Pump Systems
The switch can be used to detect the water level within a tank. When the water level in the tank
reaches the maximum, the pressure will increase and the LORENTZ Controller will stop the pump and
indicates Tank Full LED.
ORDER INFORMATION
• Item no.: 19-000310 product name: Pressure Switch 1-5bar
FEATURES
• Reliable water pressure detection
• Simple to install
• Trouble free operation
• Corrosion-free
TECHNICAL DATA
• Pressure range between 1 and 5 bar
• 2x cable gland Ø 5-9mm
• G ¼’’ pipe thread
• Meets the requirements for CE
DIMENSION/WEIGHT
• Packaging dimensions: 130 x 105 x 65 mm
5.1 x 4.2 x 2.6 in
• Total weight: 0.5 kg / 1 lbs
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
Liquid Level Sensor
Sensor for measuring the level of liquid in a well or tank
USE / PURPOSE
The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors can be used for
collection of long term liquid level monitoring and also for pump control in applications where a well probe cannot be
used. The liquid level sensor must be used with a compatible LORENTZ Controller (see requirements).
FEATURES
• Gauge pressure sensor, pressure measurement relative to atmosphere
• For measuring levels of liquid in a well or tank
• Accurate, robust sensor
• For use with LORENTZ PumpScanner and pumpMANAGER
REQUIREMENTS
• LORENTZ PS2 controller, LORENTZ PSk2 controller or PS Controller equipped
with a licensed PS DataModule
• The cable contains a capillary tube to balance the sensor against atmospheric
changes. The sensor must be ordered with the required cable length for the
application as it cannot be spliced. Further cable lengths are available on demand,
please contact LORENTZ.
ORDER INFORMATION
Item # Product Pressure range Cable length
0-100 kPa
Liquid Level Sensor,
19-005040 0 to 10 m / 0 to 33 ft 30 m / 100 ft *
0-10m/33ft, 30m/100ft Cable
0 to 1 bar / 0 to 14.5 psi
0-200 kPa
Liquid Level Sensor,
19-005050 0 to 20 m / 0 to 66 ft 40 m / 130 ft *
0-20m/66ft, 40m/130ft Cable
0 to 2 bar / 0 to 29 psi
0-500 kPa
Liquid Level Sensor,
19-005080 0 to 50 m / 0 to 164 ft 60 m / 200 ft *
0-50m/164ft, 60m/200ft Cable
0 to 5 bar / 0 to 72.5 psi
0-1000 kPa
Liquid Level Sensor,
19-004395 0 to 100 m / 0 to 328 ft 140 m / 460 ft *
0-100m/328ft, 140m/460ft Cable
0 to 10 bar / 0 to 145 psi
*Further cable length is available on demand. Please contact LORENTZ.
BERNT LORENTZ GmbH
Siebenstuecken 24, 24558 Henstedt-Ulzburg, Germany
V180822
USE / PURPOSE
The sensors are commonly used to measure the pressure in the delivery pipeline or in a vessel. The pressure
signal is used with a LORENTZ pump controller to measure pressure and for pressure switching or constant
presure applications. The liquid pressure sensor must be used with a compatible LORENTZ Controller.
FEATURES
• Gauge pressure sensor, pressure measurement relative to atmosphere
• For measuring pressure in a pipe or vessel
• Accurate, robust sensor
• For use with LORENTZ PumpScanner and LORENTZ Global
REQUIREMENTS
• LORENTZ PS2 controller, LORENTZ PSk2 controller or LORENTZ PSk3 Controller
• Care must be taken to position the sensor without turbulent water
to ensure accurate measurement
• G1/4” or G1/2” female threaded filling / air vent hole is required to mount the sensor
The NWM Water Meter is a device for Characteristics Dimensions and weights
measuring flow in water applications.
½ All materials in contact with water Description DN25 DN32
The NWM water meter has a pulse are corrosion resistant. L [mm] 260 260
output for connection to LORENTZ ½ Five (5) digit mechanical display L1 [mm] 380 384
pump controllers. showing total liquid in 1m3 D [mm] G1-1/4B G1-1/2B
increments.
d [mm] R1 R1-1/4
The water meter is used in applications ½ Reed switch output which can
where measured flow and water be connected to PS2 and PSk H [mm] 117,5 117,5
volume values are required. controllers. H1 [mm] 206,5 206,5
½ Easy to install. W [mm] 98 98
The NWM Water Meter is suitable for Net Weight [kg] 2,6 3,1
applications with a pipe size of DN25 Technical Data
and DN32.
½ Water temperature max. 50°C
The NWM Water Meter contains a ½ Water pressure: max. 16 bar
special sealed liquid which is separate ½ Reed switch positioned on the
from the flow water to maximize x0,001 dial pointer: 10 l/imp.
readability, avoid fogging and avoid ½ Reed Switch cable length: 1,45m
scaling. ½ IP64
½ CE Conformity Order information
Flow DN25 DN32 The Accuracy curve shows the deviation in percent error
Max. flow rate: Qmax [m³/h] 7,87 12,5 for different flow rates. In regular operation the deviation
Nominal flow rate: Qn [m³/h] 6,3 10 is between -2% and +2%.
Transition flow rate: Qt [m³/h] 0,063 0,1
Packaging information
Minimum flow rate: Qmin [m³/h] 0,036 0,062
Error [%]
6
Description 19-002220 19-002225
4 Dimension [LxWxH] [mm] 310x280x250 310x280x250
2 Gross Weight [Kg] 3,5 3,9
Reed switch impulse data output X Volume [m³] 0,022 0,022
0 X
X
Reed switch impulse -2 X
Water meter size Liters per impulse
-4
DN25 10
-6
DN32 10
Qmin Qt Qn Qmax
Flow [m³/h]
1 2
220601
Water Meters Water Meters
Flow measuring instrument for water use Flow measuring instrument for water use
Error [%]
The WP Water Meter is a turbine type Characteristics Accuracy Curve 6
intended to measure high flow rates in ½ Removable and interchangeable The Accuracy curve shows the deviation in percent error for different flow 2
water applications. measuring element. rates. In regular operation the deviation is between -2% and +2%. 0
DN65 100 19-002165 Water meter, WP-DN50, 0.1 cbm/p 15 280x230x320 0,021
DN80 100 19-002170 Water meter, WP-DN65, 0.1 cbm/p 16 290x230x330 0,022
19-002180 Water meter, WP-DN80, 0.1 cbm/p 17 280x240x350 0,023
DN100 100
19-002190 Water meter, WP-DN100, 0.1 cbm/p 20 320x260x350 0,029
DN125 100
19-002200 Water meter, WP-DN125, 0.1 cbm/p 25 340x310x390 0,041
DN150 1000
19-002210 Water meter, WP-DN150, 1 cbm/p 38 370x340x420 0,053
DN200 1000
19-002202 Water meter, WP-DN200, 1 cbm/p 49 415x390x435 0,070
3 4
220601
SunSwitch
Automatic Solar Level Switching Device
The SunSwitch can be used for any application where you need to switch depending on the solar
intensity. It is an autonomous working unit that supplies itself with power from the PV-module on its
rear side.
ORDER INFORMATION
• Item no.: 19-000050 product name: SUN SWITCH Light-Sensor
FEATURES
• Trouble free operation
• Pump will only run when minimum flow rates or
pressure levels can be achieved which are required
by certain applications
• Reduced wear on the pump and motor since the
pump only starts when it will continue to run
TECHNICAL DATA
• Contact rating:
▪ Max. voltage 250 VAC / 220 VDC
▪ Max. current 2A
▪ Max. power 60 W / 62.5 VA
• Enclosure class: IP54
• Cable length: 4 m
• Wire size: 3x 1.0mm² or AWG 18, waterproofed
• Mounted close to the solar array
• Manual with further information
is available in PartnerNet
• Meets the requirements for CE
DIMENSION/WEIGHT
• Packaging dimensions: 230 x 115 x 90 mm
9.1 x 4.5 x 3.5 in
• Total weight: 1.2 kg / 0.6 lbs
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
Sacrificial Anode for HR(E) Pumps
Zinc sacrificial anode for corrosion protection of HR(E) pump ends
USE / PURPOSE
The LORENTZ Sacrificial Anode is designed for use with LORENTZ pump ends. Where solar pump ends operate in aggres-
sive water conditions acidic water can attacks the passive layer of the high quality-steel pump end. This corrosion re-
duces the life time of the product. The LORENTZ Sacrificial Anode protects the pump system from this type of corrosion
and extends the pump life.
ORDER INFORMATION
• Item no.: 19-002621 Product name: Anode, Sacrificial Zink Anode, Di42mm
• Item no.: 19-002622 Product name: Anode, Sacrificial Zink Anode, Di48mm
• Item no.: 19-002624 Product name: Anode, Sacrificial Zink Anode, Di40mm
FEATURES
• Simple and cost effective part to protect the pump end from corrosion
• Designed for HR(E) pump ends
TECHNICAL DATA
1. A flow sleeve reduces the amount of dirt in the pump. Where water sources contain sand or
have the potential for dirt falling into them (uncapped wells) a flow sleeve is recommended to
protect the pump from dirt. Due to the large inner diameter of the flow sleeve the water rises
very slowly and dirt deposits at the bottom of the well. Subsequently, water with less
sediments enters the pump which increases its lifetime.
2. A flow sleeve cools the motor. In open water, tanks or pools there is no natural flow of water
across the motor which can lead to heat build-up. The tube enforces water flow across the
motor which has a cooling effect.
ORDER INFORMATION (please compare (1), (2) etc. with the sample flow sleeve)
Item no. Product name Scope of delivery Suitable for
19-000220 Flow Sleeve Kit for (1) 1 x flow sleeve adapter All HR pumps
4” HR Pumps (2) 2 x hose clamp with 4" motor
(3) 4 x countersunk bolt
M6x20
(4) 1 x PVC tube: ø125x5,
19-000225 Flow Sleeve Kit for 800 mm length All HRE pumps
4” HRE Pumps with 4" motor
19-000240 Flow Sleeve Adaptor (1) 1 x flow sleeve adaptor All HR pumps
for 4” HR Pumps (2) 2 x hose clamp with 4" motor
19-000245 Flow Sleeve Adaptor (3) 4 x countersunk bolt All HRE pumps
for 4” HRE Pumps M6x20 with 4" motor
FEATURES
• Due to the large inner diameter of the flow sleeve the water
rises very slowly allowing dirt to settle at the bottom of the well
• The life expectancy of the pump is increased due to less sand
entering the pump
• Simple installation
• Can be used with PS2-200 – PS2-4000 HR(E) Pumps
• Min. well diameter of 6” (150 mm) required sample flow sleeve
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
DIMENSIONS/WEIGHT
Flow Sleeve Kit for 4” HR(E) Pumps (19-000220 or 19-000225):
• Packaging dimensions: 850 x 150 x 130 mm
33.5 x 6.0 x 5.1 in
• Total weight: 3.7 kg / 8.2 lbs
Flow Sleeve Adaptor for 4” HR(E) Pumps (19-000240 or 19-000245, without PVC tube):
• Packaging dimensions: 135 x 135 x 135 mm
5.3 x 5.3 x 5.3 in
• Total weight: 1.2 kg / 2.6 lbs
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
PS2 Manual Speed Controller
Device to provide manual motor speed control of PS2 systems
The LORENTZ PS2 Manual Speed Controller allows adjustment of the maximum
motor speed without using the PumpScanner App. To use the Manual Speed
Controller, it is required to activate this function in the settings of PumpScanner
during or before installation.
Llk
ORDER INFORMATION
• Item no.: 19-000035 Product name: PS2 Manual Speed Controller
FEATURES
• Allows manual control of PS2 motor speed
• Outdoor rated, installed in the housing of the controller
TECHNICAL DATA
• Voltage: 15-24 V DC
• Enclosure class: IP65
• Ambient temperature: -38…50 °C (-36… 122 F)
• Wire size: 2 x 0,75 mm²/18 AWG
• Replaces Ø 20mm cable gland
• Meets the requirements for CE
• Please note that if “Manual Speed Controller” is configured then “Set speed limitation” function
is not available in PumpScanner.
DIMENSION/WEIGHT
• Packing dimension : 100 x 70 x 35 mm; 3.9 x 2.7 x 1.3 in
• Total weight: 0.2 kg / 0.4 lbs
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
PS 2 Controller Plug Kit
Kit for an easy and electrical safe installation of PS2 Controller
The LORENTZ PS2 Controller Plug Kit can be installed on any PS2 system. The kit extends the internal
wiring connections to plugs allowing systems to be pre-wired and delivered to site. Possible uses for the
plug kit are where time on site needs to me minimized, where systems are often moved or where the
skills available onsite do not allow for a standard installation.
The sensor extension kit allows the installation of two additional sensors, the standard set contains only
two plug sets for sensor connections.
Order Information
Features
Technical Data
Ambient
PLUG Wire size max. current max. voltage
temperature
max, 6mm²
Motor 32 A 600V DC -40°C … +90°C
(10 AWG)
40 A
max 8mm²
PV (27A at 2.5mm² 1500V DC -40°C …+90°C
(8 AWG)
/14AWG)
max. 1.5mm²
Sensor 3A 50V DC -40°C …+90°C
(16 AWG)
Packing Dimension/Weight
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
Surge Protector2
Device to Protect LORENTZ Pump Accessories from Voltage Spikes
ORDER INFORMATION
• Item no.: 19-005210 product name: Surge Protector2
FEATURES/COMPATIBILITY
• Reliable surge protection device for any switched, pulse or
analogue (4-20 mA) inputs sensors including:
o Well Probe Sensor 19-000000
o Water Sensor 19-000001
o Float Switch 19-000030
o Pressure Switch 19-000310
o Liquid Level (all types, e.g. 19-005040)
o Liquid Pressure Sensor (all types, e.g. 19-004460)
o Water Meter (all types, e.g. 19-002160)
o Sun Switch (19-000050)
• The device must be installed inside the PS2 or PSk2 controller.
TECHNICAL DATA
• Max. voltage: 30 V DC
• Max current 8/20µs: 500 A
• Enclosure class: IP20
• Ambient temperature: max. 80°C (176°F)
• Wire size: 2 x 1.5mm² (AWG 16)
• Meets the requirements for CE
DIMENSION/WEIGHT
• Packing dimensions: 56 x 26 x 120 mm
2.2 x 1.02 x 0.47 in
• Total weight 0.1 kg / 0.2 lbs
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
PowerPack 4000S
DC power supply for PS2-4000 pump systems
Description
The PowerPack 4000S is an outdoor
rated power supply unit which allows
LORENTZ PS2-4000 systems to be po-
wered from an AC (mains voltage) power
source. The PowerPack 4000S can be PP4000S
AC PowerPack
OFF www.lorentz.de
v210521
*
SN
IEC/EN 62368-1*
IP33 ! EN 61000-6-2
EN61204-3
UL62368-1
Features
DC power supply to power LORENTZ
solar pump systems from the grid or a
generator
Single phase powered device
Robust weatherproof housing
Wall or panel mount possible
Efficiency up to 93%
External on / off switch plus LED
indicator
Forced air cooling by built-in fans
Protections against short circuit, over-
load, over voltage, over temperature,
fan failure
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
Order information
A 280 mm / 11 in
B 350 mm / 13.8 in F D
C 140 mm / 5.5 in
D 334 mm / 13.1 in C A
E 384 mm / 15.1 in
F 180 mm / 7.1 in A= 28
B= 35
C= 14
B
E
D= 33
E= 38
Product Dimensions for Ins
F= 18
Mounting
Fixing pattern for holes: 310 x 292 mm /
12.2 x 11.5 in
F
C
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
Water Level Measurement Solution
The LORENTZ Water Level This solution allows control of the Features
Measurement Solution (WLMS) pump based on the water level in the
accurately measures water levels source or tank. It delivers not only ½ Measures water levels in tank, well
in boreholes and tanks. WLMS is a information about the current water or other water source
combination of pressure sensor and level but also about trends related to ½ Provides pump run dry run
plug in barometer to provide water water usage. Predicting and planning protection
level measurement for PS2 and PSk3 for low water levels is possible with ½ Absolute pressure sensor -
systems. Used in conjunction with this solution. complete with plug in barometer
inbuilt software WLMS allows you to ½ Control of pump based on sensor
record and monitor water levels in The WLMS can also provide dry data
your tank and control your system run protection for the pump and ½ Very simple configuration and high
based on these levels. is a very good alternative to a well customer value
probe in any water source that is ½ Real time and historic level data
The sealed sensor comes with a plug- prone to calcium scaling, snails, is viewed locally via LORENTZ
in barometer placed in the controller algae or other contaminants that can CONNECTED apps (PumpScanner
and measures the pressure based on effect operation of mechanical float or Assistant or remotely via
the difference between the submersed switches. LORENTZ Global
sensor and the barometer.
Sensor type absolute pressure sensor ½ for use with LORENTZ PS2
Enclosure class IP68 controllers and LORENTZ PSk3
controllers
Sensor housing high tech polymer
Measuring range 25 m / 82 ft water level
Accuracy +/- 0.35 m / 1.15 ft
Diaphragm material stainless steel AISI316L
O-ring material FKM
Overpressure max 75m / 246 ft water column
Min shut off level 0.5 m / 1.6 ft
Output signal 4-20mA
Power supply 12-28V DC
Cable jacket PVC
Cable length 35 m / 114.8 ft
Application temperature -10 to 80° C / 14 to 176° F
Meets the requirements for CE
8
WLMS Ordering Information
Order information
Dimensions
Packing Dimensions Weight
225 x 205 x 70 mm / 8.9 x 8 x 2.8 in 1.5 kg / 3.3 lbs
Shipping Items
Splice kit
9
PV Disconnect 400-50-3-P PV Disconnect 400-50-3-P
Connection Box with DC Disconnect Switch, String Fuses and Surge Connection Box with DC Disconnect Switch, String Fuses and Surge
Protection Device Protection Device
Description Compatibility
PV Fuse, 15A
parallel to the solar pump system. [WxH, Hole diameter] [10.6 x 5.9, Ø0.236 in]
Ground cable size ≥ 6 mm² / AWG 10
½ Built-in protection with Fuses and
Quantity of fuses 6
SPD.
½ Robust weatherproof housing Fuse current rating 15 A Order and Packaging information
designed to make installation Fuse voltage rating 1000 V DC
simple. Fuse Size 10 x 38 mm Item number 19-001975
½ Lockable to secure the system PG glands (input) 6 x M16
during maintenance (power locked Product name PV Disconnect 400-50-3-P
PG glands (output) 2 x PG-11
off). Packed gross weight 3.4 kg [7.5 lbs]
PG gland GND 1 x M16
½ Internal touch protection with
Packed volume 0.018 m3 [0.63 ft3]
screws. Enclosure class IP 68
Packaging dimensions
V220803
½ Required for a professional Housing material Polycarbonate 360 x 250 x 200 mm [14.1 x 9.8 x 7.8 in]
installation of solar pumping [LxWxH]
Approvals and standards EN 60947-3 / 6094-3
systems
1 2
PV Disconnect 400-50-1-S PV Disconnect 400-50-1-S
Connection Box with DC Disconnect Switch and Surge Protection Device Connection Box with DC Disconnect Switch and Surge Protection Device
Description Compatibility
187
requires a reliable ground connection.
218
[LxWxH] [8.6 x 5.4 x 7.8 in]
187
218
139
The product can connect one (1) string
139
Net Weight 1.7 kg [3.7 lbs]
of PV Modules through the enclosed
DC disconnect switch safely to a solar
pump system.
V220802
Packaging dimensions
Housing material Polycarbonate 250 x 250 x 200 mm [9.8 x 9.8 x 7.8 in]
[LxWxH]
Approvals and standards EN 60204-1 / EN 60947-3
1 2
PV Disconnect 400-50-3-S PV Disconnect 400-50-3-S
Connection Box with DC Disconnect Switch and Surge Protection Device Connection Box with DC Disconnect Switch and Surge Protection Device
Description
Compatibility
The LORENTZ PV Disconnect 400-
50-3-S is a PV connection box with an ½ For use with LORENTZ PS2
integrated DC disconnect switch, a controllers [PS2-150 to PS2-4000].
combining function and additionally
is equipped with a Surge Protection
Device (SPD), for use with LORENTZ
PS2 pump systems.
V220803
½ Required for a professional Housing material Polycarbonate 360 x 250 x 200 mm [14.1 x 9.8 x 7.8 in]
installation of solar pumping [LxWxH]
Approvals and standards EN 60204-1 / EN 60947-3
systems
1 2
PV Disconnect 400-50-6-S PV Disconnect 400-50-6-S
Connection Box with DC Disconnect Switch and Surge Protection Device Connection Box with DC Disconnect Switch and Surge Protection Device
Description
Compatibility
The LORENTZ PV Disconnect 400-
50-6-S is a PV connection box with an ½ For use with LORENTZ PS2
integrated DC disconnect switch, a controllers [PS2-150 to PS2-4000].
combining function and additionally
is equipped with a Surge Protection
Device (SPD), for use with LORENTZ
PS2 pump systems.
V220803
½ Required for a professional Housing material Polycarbonate 360 x 250 x 200 mm [14.1 x 9.8 x 7.8 in]
installation of solar pumping [LxWxH]
Approvals and standards EN 60204-1 / EN 60947-3
systems
1 2
LC330-P72
High-efficiency PV Module
Features
high energy yields ensured by high conversion
efficiency
sturdy, clear-anodized aluminum frame with
pre-drilled holes for quick installation
advanced EVA encapsulation with triple-layer
backsheet, meets the most stringent safety
requirements for high-voltage operation
pre-wired junction box equipped with connec-
tors ”plug‘n‘play“
Specifications
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
Electrical Performance
140 140
9 9
Current [A]
80 Voc 80
5 5 600 W/m2
50°C Pmax
4 4 60 60
3 3 400 W/m 2 Isc
75°C 40 40
Pmax
2 2
20 20
1 200 W/m
2
1
0 0 0 0
0 10 20 30 40 50 0 10 20 30 40 50 -25 0 +25 +50 +75 100 0 200 400 600 800 1000 1,200
Voltage [V] Voltage [V] Cell temperature [°C] Irradiance [W/m2]
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
Pole Mount PM-1-x
PV Module Mounting System Top of the Pole
CHARACTERISTICS
Total PV Module* surface up to 8.5 m² / (91 ft²)
Capacity of 1 to 6 framed PV Modules*
Fast and simple installation by one installer
Statics calculated to European and American standards
High reliability and life expectancy
TECHNICAL DATA
Mounting Structure
Infinitely variable tilt angle between 0° and 55° reduced quantity and loads
Horizontal rail orientation for ease of mounting by Flexible PV Module* mounting sizes
one installer For PV Module frame specifications see the diagrams
Total PV Module* surface up to 8.5 m² / (91 ft²) below
1 to 6 framed PV Modules* are mountable with Premium, corrosion-resistant material (stainless steel,
dimensions up to 1.6 to 0.8 m / 63 to 32’’, or 1 to 5 aluminum, hot dipped galvanized steel)
framed PV Modules* are mountable with dimensions Suitable for high wind speeds up to
up to 1.7 to 1.0 m / 76 to 40’’, or 1 to 4 framed PV 130 km/h /81 mph, according to European and
Modules are mountable with dimenstions up to 2 m American standard
to 1 m / 39 to 78’’, larger modules possible but with
Foundation (not included)
Concrete foundation with steel reinforcement (min.
dimensions provided in the table on page 2)
min. 20 mm / 0.8 in
US Market
Beam US Standard pipe schedule 40
Cross section [inch] 2.5
Length [inch] for the calculation of the beam length A see formula below
Pole US Standard pipe schedule 40
Cross section [inch] 2.5 4
Length [inch] 75
** for PV Modules of 1.7 x 1.0 m: max. tilt 45°
Calculation of beam length A for local purchase
A
Metric in mm:
A = n * w + (n+1) * 30 mm
Imperial in inch:
A = n * w + (n+1) * 1.2 inch
B
n: Number of mounted PV Modules
0.5 m / 1.64 ft
1.2 m / 3.9 ft
w: Width of PV Module
1.5 m / 5 ft
2 m / 6.6 ft
D D
Dimensions with installed PV Modules 1.6 x 0.8 m and 1.7 x 1.0 m
BERNT LORENTZ GmbH
Siebenstuecken 24, 24558 Henstedt-Ulzburg, Germany
V200309