Professional Documents
Culture Documents
E1 Long
E1 Long
E1 Long
2. ALL WIRING SHALL BE INSTALLED IN STANDARD CONDUITS RUN EMBEDDED IN CONCRETE AND HOLLOW 12W, OUTDOOR LED CANISTER TYPE LIGHTING FIXTURE
BLOCK STRUCTURES,COLUMNS, WALLS, PARTITIONS, AND OR RUN CONCEALED BETWEEN DOUBLE WALL S1 ONE GANG SWITCH-1 WAY
PARTITIONS AND INSIDE THE CEILING SPACES. WHERE THE USE OF THE CONCEALED CONDUIT WIRING IS Sab TWO GANG SWITCH-1 WAY
IMPRACTICABLE, SURFACE METAL MOULDING MAYBE USED. Sa-2way ONE GANG SWITCH-2 WAY
INSTALLED AT CONVENIENCE AND INCONSPICUOUS LOCATIONS.ALTHOUGH SUCH BOXES ARE NOT PANEL BOARD
SHOWN ON THE PLAN NOR MENTIONED IN THE SPECIFICATIONS. PB N
4. THE ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE SUPERVISION OF A DULY XX CIRCUIT NO.
WP
TWO GANG, 220V CONVENIENCE OUTLET-WATER PROOF
ACU
1.5 HP SPLIT TYPE AIRCONDITION UNIT
W
WASHING MACHINE
REF
REFRIGERATOR
M
MICROWAVE
1 VICINITY MAP
E 1 NOT DRAWN TO SCALE
MAIN GEN
100AT,2P
30AT,2P
MTS
CIRCUIT 1 CIRCUIT 2
15AT ,2P 15AT ,2P 2-30mm2 THHN in 63mmPVC
CIRCUIT 3 CIRCUIT 4
20AT ,2P 20AT ,2P
CIRCUIT 5 CIRCUIT 6
20AT ,2P 20AT ,2P
KWH METER
CIRCUIT 7 CIRCUIT 8
20AT ,2P 20AT ,2P
PANELBOARD
CIRCUIT 9 CIRCUIT 10
20AT ,2P 20AT ,2P
GROUND
CONCRETE ENCLAVED
CERTIFIED BY: PRC No. XXXX PROJECT TITLE: APPROVAL: SHEET CONTENT: REVISIONS: SHEET NO.:
VALIDITY XXXX