1 Name and Adress OF Manufacturer XCTY 2 Type of the cable CU/XLPE/PVC/SWA/PVC 3 Rated Voltage kV 0.6/1 4 Size 4X35 5 Standard Applied Design guidelines IEC60502.1/ BS7889 Conductor IEC60228 Insulation and sheath IEC60502.1 Flame resistance IEC60332.3 Fault current carrying of conductor IEC 60949 6 Application Max. continuous operation temperature ℃ 90 Max. temperature at short circuit(≤5s) ℃ 250 Lowest recommended temperature during installation ℃ 0 7 Core identification and mark as listed below, or as purchase order. 7.1 Identification of core: For 4 Conductors: Red, Yellow, Blue, Black. 7.2 Mark on outer sheath: MANUFACTURER ELECTRIC CABLE STANDARD SIZE VOLTAGE TYPE YEAR METER A line of characters along the surface of outer sheath by printing. Eg: XCTY IEC60502-1 IEC60332-3 POWER CABLE 0.6/1kV CU/XLPE/PVC/SWA/PVC 4C35 MM2 2022 xxxm 8 Dimension 8.1 Conductor Cross sectional area mm2 35 Material Plain annealed copper Shape of finished conductor Sector Compacted No. of strands/single wire diameter of Phase No./mm 7/2.52 8.2 Insulation Material XLPE OVERSES SALES SUBSIDIARYS: HENAN XINCHANGIMPORT AND EXPORT TRADE CO., LTD., #2 building of # 85 Jinshui Dong Road, Zhengzhou, Henan,P.R.China INDUSTRIAL PARK,GONGYI,HENAN,P.R.CHINA Tel: 0086-15936206976 http://www.cncuxc.com 1209792977@qq.com
Nominal thickness of Phase mm 0.9
Minimum radial thickness mm 0.71 8.3 Fillers Binding tape Material Non-Hygroscopic 8.4 Inner sheath Material PVC Nominal thickness mm 1.0 OD over bedding (Approx.) mm 24.40 8.5 Armored Material G. steel wire Diameter of armoring single wire mm 1.6 8.6 Out Sheath Material PVC Nominal thickness mm 2.0 Minimum radial thickness mm 1.40 8.7 OD of the finished cable (Approx.) mm 29.5 8.8 Weight of the finished cable (Approx.) Kg/km 2396 9 Electrical and Mechanical particulars 9.1 Max. D.C. Phase conductor resistance at 20℃ Ω/km 0.524 9.2 High Voltage test KV/(min) 3.5/5 The result No breakdown 9.3 Min. bending radius During installation xD 12 Installed xD 10 9.4 Max. allowable pulling force of conductor KN 9.8 9.5 Fault current carrying of phase conductor (1s) KA 5.0 10 Current Carrying Capacity Maximum conductor temperature ℃ 90 Ambient air temperature ℃ 40 Ground temperature ℃ 25 Depth of laying M 0.8 Thermal resistivity of soil C. m/W 1.2 In Air A 115 In Ground A 150 In Duct A 135 Note: these values are only for reference. 11 Environment temperature correction coefficient. Environment temperature(℃) Ambient Air Temperature Variation Ground Temperature Variation 20 25 35 40 45 50 55 10 15 20 25 30 35 40 1.18 1.14 1.05 1.00 0.95 0.89 0.84 1.11 1.07 1.04 1.00 0.96 0.92 0.88 12 Packing style Wooden Drum OVERSES SALES SUBSIDIARYS: HENAN XINCHANGIMPORT AND EXPORT TRADE CO., LTD., #2 building of # 85 Jinshui Dong Road, Zhengzhou, Henan,P.R.China INDUSTRIAL PARK,GONGYI,HENAN,P.R.CHINA Tel: 0086-15936206976 http://www.cncuxc.com 1209792977@qq.com