Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

FLOW CONTROL VALVE

(Electro-Proportional, Normally Closed, Fast-acting)


Ordering Code: PEV-16A-2D-X-Y-Z
2

Torque 3 - 5 Nm

Coil EC-19A 1

TECHNICAL DATA
137.5

19
Max.Operating pressure: 350 bar
115.2

Rated flow: 240 l/min


Cavity-Tooling: 16A-2
41.2 Hex.
(1-5/8 inch) Installation torque: 200 - 215 Nm
Weight:(with Coil) 1.05 kg
Locating (without Coil) 0.81 kg
Shoulder
M36x2.0
12.8

Leakage at ∆P of 140 bar


Approximately 40 cc/minute maximum
62

Typical hysteresis less than 4% of


2 rated current at 10 bar pressure
drop - Pulse Width Modulated(PWM)
Recommended PWM frequency
31.75 60 - 150 HZ, application dependent,
140 HZ typical
1 Illustrations / detail are
UNIT:mm for reference only.
Data subject to change.
Coils must be ordered separately
2 Ports、22 Watt. Coil 19 mm tube
Typical Metering Preformance (① ②) P=14 bar
300
X OPERATION
250 Z=2400
Normally-Closed,No Reverse
Flow-Q(l/min)

200 Z=1600 09 Flow Energized,Nose-in,


Side-out Operation
150

100 Z=0800 Y OPTIONS


50 N Non-adjustable
0 Manual Override
(24 V) 100 200 300 400 500 600 (Emergency Manual
(12 V) 200 400 600 800 1000 1200 M Proportional Flow
Command Current, mA
Adjustment)
Typical Pressure Drop (② ①) Push Style
40 P Manual Override
Pressure- P(bar)

32
FLOW
Z
24 NOMINAL CAPACITY

16
0800 0 - 80 LPM
1600 0 - 160 LPM
8
2400 0 - 240 LPM
0 40 80 120 160 200 240
*If there is a requirement for factory minimum
flow setting (port ③), please contact Winner
Flow-Q(l/min) sales department.
Rev.240402 B.352.213.E

You might also like