Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Sample Wiring Diagrams for ETC-AED330A-24

Needed:
• ETC-AED330A-24 Temperature controller, including temperature sensor
• DC Power supply, 12 to 24 volts DC output
• AC power cord, three wire
• TEC or TEC assembly such as ATA, ATP, or ATL products
• Wire for making connections, Minimum AWG 20
Temp Sensor placed
EXAMPLE DIAGRAM FOR A TEC at area of control

SENSOR

AC Plug 9 10
Sensor

DC ETC-
Power AED330A-24
Temperature TEC
Supply Controller
12-24 Relay
Output
Input
Power
L N V- V- V+ V+ 1 2 11 12 - +

Notes:
1. Some DC power supplies do not have multiple V- and V+ terminals. It is OK to
combine all the V- wires together on a single V- terminal and all the V+ wires together
on a single V+ terminal.
2. The temperature sensor's location can have a dramatic effect on the effectiveness of
the system. Experiment with its location to achieve desired results.
3. The ETC-AED330A-24 controller can operate with a minimum of 12 volts DC of input
power on terminals 11 and 12. Make sure terminal 11 is positive (+) DC and terminal
12 is negative (-) DC power. The maximum input power is 24 volts DC.
4. Typical control accuracy can be +/- 2.0 C of setpoint temperature. Tuning of the
controllers parameters can create better control accuracy. Please see the
ETC-AED330A-24 instructions.
Temp Sensor placed
EXAMPLE DIAGRAM FOR A TEC ASSEMBLY at area of control

SENSOR

AC Plug 9 10
Sensor
DC TEC
ETC-
Power AED330A-24
ASSEMBLY
Supply ATA or ATP
Temperature
or ATL
12-24 RelayController Input
Output Power
L N V- V- V+ V+ 1 2 11 12 TEC FAN
+ - + -

EXAMPLE DIAGRAM FOR A TEC Temp Sensor placed


at area of control
with SEPARATE POWER SUPPLY
SENSOR

AC Plug 9 10
Sensor

DC ETC-
Power AED330A-24
Temperature TEC
Supply Controller
for TEC Relay
Output
Input
Power
L N V- V- V+ V+ 1 2 11 12 - +

DC
Power
Supply
12-24
L N V- V- V+ V+