Professional Documents
Culture Documents
NCR 2024 0037 Faulty Packaging
NCR 2024 0037 Faulty Packaging
NCR 2024 0037 Faulty Packaging
PO No: B016899
Description:
P6791 found not intact on the bottom.
Supplier investigation details, root cause analysis:
Occurred:
1. Fatigue of the pressure spring at the bottom craft of the bowl leads to insufficient elasticity;
2. The abrasion of the bowl bottom support fixture slide rail caused deviation when the bottom craft
of the bowl was transferred to the designated position;
Outflow:
1. Depending on visual inspection only at finished products position there is a risk of leakage;