S pumps, range 70
80 to 140 kW
60 Hz
S pumps, range 70
1. Introduction 4
Table of contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Main constructional features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2. Performance range 5
Performance range overview, S pumps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Performance range, S pumps, range 70 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
List of pump curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3. Identification 7
Type key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Pump nameplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Ex approval plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Cable entry approval plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4. Selection of product 9
Ordering the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5. Product range 10
Standard pumps - cast iron, 3 x 380/660 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Explosion-proof pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6. Variants 14
List of variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
7. Construction 15
Sectional drawing, motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Components and material specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
8. Product description 26
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Motor range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Explosion-proof pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Level controllers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
11. Accessories 60
Accessories (for installation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Other accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
12. Dimensions 63
Recommendation for pump foundations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
2
S pumps, range 70
Basic pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Table of contents
Installation on auto-coupling system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Dry, vertical installation on concrete foundation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Dry, horizontal installation on base stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
13. Weights 74
3
1 S pumps, range 70
1. Introduction
Introduction
Introduction Applications
This data booklet deals with Grundfos heavy-duty S pumps are designed for applications, such as these:
sewage pumps, type S, range 70. • raw-water intake
• wastewater treatment plants
• municipal pumping stations
• public buildings
• blocks of flats
• industries
• garages
• underground car parks
• car-wash areas
• restaurants and hotels.
The pumps are suitable for both temporary and
permanent installation. The lifting bracket fitted on the
pumps facilitates easy transportation as well as
installation at the installation site.
4
S pumps, range 70
2
2. Performance range
Performance range
Performance range overview, S pumps
+
>P@
+]
5
2 S pumps, range 70
H
[m]
S Pumps
80
Range 70
70 60 Hz
60
50
S2.90.200
40
30
S2.100.200 S2
.12
25 2. 2
50
20
S3.
120
.30
0
15
S2.105.250 S2.145.300
10 S3.115.500
S2.90.200.1000/1200.2.70H 52 S2.90.200.1000/1200.2.70H 54
High High
S2.105.250.800.8.70H S2.105.250.800.8.70H
56 58
S2.122.250.1100/1400.6.70H S2.122.250.1100/1400.6.70H
6
S pumps, range 70
3
3. Identification
Identification
Type key 1
The power output (P2) indicated in the type key, which is used to
indicate the motor size, can deviate from the actual power output.
Please note that the pump type described in this Please refer to the nameplate or the chapter Performance curves
and technical data for the exact power output.
booklet is not necessarily available in all variants. 2 PTC sensors are connected directly to IO 113 or other PTC relay.
Example S1.100.100.55.4.50M.S.205.G.N.D.511.Z
Code Explanation Designation Pump nameplate
Grundfos sewage and wastewater
S
pump
Pump type 1
Multi-channel impeller pump installed
ST
in a column pipe 2 23
1 Single-channel impeller
2 Two-channel impeller 3 12
Impeller type
3 Three-channel impeller 4 13
V SuperVortex impeller 14
100 Maximum solid size [mm] Pump passage 5
15
Nominal diameter of pump outlet port 6
Pump outlet, S-type 16
100 [mm]
Nominal diameter of column pipe [mm] Pump outlet, ST-type 7 17
P2 = Code number from type
55 Power output [kW] 1 8 18
designation / 10
7
3 S pumps, range 70
The approval plates give the following details: b Control of ignition sources
d Flameproof
Pos. Description IIB Gas group (Ethylene)
Tamb Ambient temperature
EU Ex symbol
Gb Equipment protection level, zone 1
II Equipment group (II = non-mining)
Baseefa Certificate number
2 Equipment category (high protection)
IECEx Certificate number
G Type of explosive atmosphere (G = Gas)
ID no Inlet identification number (e.g. 36-1)
CE CE mark
0344 Number of quality assurance notified body
Ex Explosion-proof motor according to European standard
b Control of ignition sources
c Constructional safety
db Flameproof enclosure
IIB Gas group (Ethylene)
T3 Maximum surface temperature of the motor is 200 °C
T4 Maximum surface temperature of the motor is 135 °C.
Gb Equipment protection level, zone 1
Baseefa Certificate number
IECEx Certificate number
8
S pumps, range 70
4
4. Selection of product
Selection of product
Ordering the product Accessories
When ordering the product you need to take the Depending on the installation type, you may need to
following four aspects into consideration: order accessories. See Accessories, page 60 for
selection of the correct accessories.
1. pump
Note: Ordered accessories are not fitted from factory.
2. custom-built variation (option)
3. accessories Controller
4. controller.
Grundfos Dedicated Controls (DC) is available.
Pump
Use Product range, page 10 and Type key, page 7 to
identify the pump that best fulfils your needs. The list
below is a detailed description of the product you get if
you order the following pump:
Pump Product no
S2.90.200.1000.4.70H.S.340.G.N.D.611 95113053
• Pump as specified in the type key
• 10 m cable
• Paint: black, NCS 9000N/RAL 9005, gloss 30,
thickness 150 µm
• Three thermal switches (Klixon) or three thermal
sensors (PTC) in stator windings
• One moisture switch below the motor top cover (two
moisture switches in explosion-proof versions; one
9
5 S pumps, range 70
5. Product range
Product range
10
S pumps, range 70
5
Cast iron, 3 x 460 V
Product range
Accessories
11
5 S pumps, range 70
Explosion-proof pumps
Product range
12
S pumps, range 70
5
Cast iron, 3 x 460 V
Product range
Accessories
13
6 S pumps, range 70
6. Variants
Variants
List of variants
Motor
15 m
25 m
Various cable lengths
30 m
50 m
10 m
15 m
EMC power cables Screened power cables for variable-speed drives 25 m
30 m
50 m
Special motor Insulation class H
Special oil Non-toxic Shell Ondina X420 1
Motor protection
Pt100 on lower bearing + Pt100 on upper bearing + Pt100
Sensor set 2
on windings
Pt100 on lower bearing + Pt100 on upper bearing + Pt100
Sensor set 3
on windings + PVS3 vibration sensor
External water-in-oil sensor WIO
Coating
300 µm (painted twice)
Special paint thickness
450 µm (painted three times)
Epoxy coating (NCS 900N/RAL 9005 gloss 30, black)
Impeller (external surface)
Belzona 1321 coating (brush painted, blue)
Impeller (internal surface) Chesterton ARC 855 ceramic coating (grey)
Epoxy coating (NCS 900N/RAL 9005 gloss 30, black)
Pump housing (internal) Belzona 1321 coating (brush painted, blue)
Chesterton ARC 855 ceramic coating (grey)
Epoxy coating (NCS 900N/RAL 9005 gloss 30, black)
Inlet cover Belzona 1321 coating (brush painted, blue)
Chesterton ARC 855 ceramic coating (grey)
Zinc anodes (outside of inlet cover / pump housing) 3 pcs.
Materials
Stainless steel lifting bracket AISI 316
Stainless steel shaft AISI 329
Impeller Duplex stainless steel ASTM A890 Grade 3A
Tests
Test at specified duty on standard impeller curve
Trimmed impeller for specified duty test
Additional test of entire QH curve (including report) 5-10 points on the pump performance curve
ISO 9906:2012 grade 1E
tolerances
ISO 9906:2012 grade 1B/1U
Different test standard Efficiency guaranteed by Grundfos
tolerances
ISO 9906:2012 grade 2B/2U
tolerances
Vibration test (including report) According to Grundfos factory quality standard
Performance test on dry test stand Contact Grundfos
NPSHr test Contact Grundfos
String test Contact Grundfos
Witness test Contact Grundfos
Miscellaneous
Special packaging Contact Grundfos
Special nameplate Contact Grundfos
Old UK-guide shoe Contact Grundfos / order guide shoe installation kit
Other variants Contact Grundfos
1
For pumps with WIO sensor Shell Ondina is not an option.
14
S pumps, range 70
7
7. Construction
Construction
Sectional drawing, motors
15
7 S pumps, range 70
Construction
16
S pumps, range 70
7
Construction
TM06 3963 1315
17
7 S pumps, range 70
Construction
18
S pumps, range 70
7
Pump
Construction
TM04 2589 2708
19
7 S pumps, range 70
Construction
20
S pumps, range 70
7
Construction
TM04 2708 4116
21
7 S pumps, range 70
Construction
22
S pumps, range 70
7
Construction
494
495
37
7a 301 26 26c
76
0.7 0.2
62
66
9a
67
67b
62a
12c 12
35a
495
494
50
37b
7a 39a
76 301 26
12a
39
12
35 0.7 0.2
62a
9a
67b
35a
67
12c
62 49
TM04 2591 0817
487
Fig. 16 Installation type H, dry, horizontal installation on base stand - version 2
23
7 S pumps, range 70
Construction
494/495
0.7 0.2
35
35a
67
12c 67b
66
62a
9a
62
49
24
S pumps, range 70
7
Components and material specification
Construction
Motor
DIN W.Nr./ DIN W.Nr./
AISI/ AISI/
Pos. Component Material EN Pos. Component Material EN
ASTM ASTM
standard standard
25
8 S pumps, range 70
8. Product description
Product description
cables on request.
15 B
The pumps have H07RN-F 450/750 V control cables
Years as standard or screened ATON VSCB 450/750 V
1 2 3 4 5 control cables on request.
A: With Grundfos SmartTrim impeller clearance The cables are 10 m long as standard. Other cable
adjustment system lengths are available on request. See List of variants,
B: Without impeller clearance adjustment system page 14.
SmartSeal The number and dimension of cables depend on the
motor size.
For the pumps with DN 250 outlet or larger, the
Grundfos SmartSeal auto-coupling sealing mounted on Motor power
Voltage
Cable size
[kW] [power + control]
the pump outlet flange provides a completely leak-
proof connection between the pump and the base unit 2 x 4 x 25 mm2 +
3 x 460 V 7 x 1.5 mm2
of the auto-coupling system. This optimises the 80
3 x 380/660 V 2 x 4 x 25 mm2 +
efficiency of the entire pumping system and keeps 10 x 1.5 mm2
operating costs at a minimum. 2 x 4 x 25 mm2 +
3 x 460 V
7 x 1.5 mm2
Bearings 95
2 x 4 x 35 mm2 +
3 x 380/660 V
The bearings are greased for life. 7 x 1.5 mm2
Main bearings: Double-row angular contact ball 2 x 4 x 35 mm2 +
3 x 460 V
7 x 1.5 mm2
bearing. Single or pair mounted angular contact ball 110
2 x 4 x 50 mm2 +
bearings for axial forces and cylindrical roller bearing 3 x 380/660 V
7 x 1.5 mm2
for radial forces. 2 x 4 x 50 mm2 +
3 x 460 V
Support bearings: Single-row deep-groove ball 7 x 1.5 mm2
120
bearing. 2 x 4 x 70 mm2 +
3 x 380/660 V
7 x 1.5 mm2
3 x 460 V 2 x 4 x 70 mm2 +
140
3 x 380/660 V 7 x 1.5 mm2
26
S pumps, range 70
8
Power cable Testing
Product description
All pumps are tested before leaving the factory. The
Outer cable
Cable type Weight Bending radius factory test report is based on ISO 9906:2012, grade
diameter
[mm2] [kg/m] [cm]
[mm] 3B. Test reports can be ordered directly with the pump
4 x 25 28.9 -31.4 1.88 19 or can be ordered separately based on the pump serial
4 x 35 32.5 - 34.7 2.43 22 number.
4 x 50 37.7 - 40.4 3.24 25
Other tests or third party inspection certificates are
4 x 70 42.7 - 45.4 4.30 28
available on request. See List of variants, page 14.
Control cable
Cable type
Outer cable
Weight Bending radius
Operating conditions
diameter
[mm2] [kg/m] [cm]
[mm] Pumps without cooling jacket in submerged
7 x 1.5 14.4 - 16.4 0.35 10 installation:
Cable entry • Continuous operation when pump is fully
submerged to the top of the motor.
Watertight PA or cast iron cable entry with soft shape
and sealing rings to prevent damage of the cable or • Intermittent operation with maximum 20 starts per
leaks. hour when the pump is submerged to the middle of
the motor and with short periods of operation down
Sensors to the top of the pump housing.
As standard the pump is equipped with these switches Warning: A motor protection device must be used
or sensors: to cut off power supply in case of overheating.
• Three thermal switches (Klixon) or three thermal Note: Explosion proof pumps without cooling jacket
sensors in the stator housing. must always be fully submerged.
• One moisture switch under the motor top cover. Pumps with cooling jacket in submerged and dry
Customised sensor options installation:
1. WIO (water-in-oil) sensor • Continuous and intermittent operation with
The WIO sensor measures the water content in the maximum 20 starts per hour with water level down
oil and converts the value into an analog current to the top of the pump housing.
signal. The two sensor conductors are for power
supply as well as for carrying the signal to the Pumped liquids
measuring device or controller. The sensor pH value: 4-10
measures the water content from 0 to 20 %. It also Liquid temperature: 0-40 °C
sends a signal if the water content is outside the When pumping liquids with a density and/or a
normal range (warning), or if there is air in the oil kinematic viscosity higher than that of water, use
chamber (alarm). The sensor is fitted in a stainless motors with correspondingly higher outputs.
steel tube for mechanical protection.
The sensor is either built-in with the motor (Ex) or Sound pressure
installed as an accessory. If the sensor is installed The sound pressure level of the pump is lower than the
externally, it is fitted in a plastic hose for mechanical limiting values stated in EC Council directive 2006/42/
protection. The WIO sensor is connected to EC relating to machinery (the EC Machinery Directive).
Grundfos IO 113.
2. PVS3 (pump vibration sensor)
The vibration sensor monitors the vibration level of
the pump by using measurements of three axes and
combining them into a single measurement
outputted in an analog current signal. The sensor
acts only as a general indicator of changes in the
vibration levels. PVS3 is to be connected to
Grundfos IO 113 and SM 113. A substantial
increase in vibration will trigger a warning or an
alarm.
An increase in vibrations can be caused by a
clogged impeller, worn bearings, closed force main
valves, etc. indicating that service inspection should
be carried out quickly in order to protect the pump
or the pipe system from being damaged.
3. Bearing temperature sensor
Pt100 bearing temperature sensor installed within
the motor housing. Sensors to be connect using SM
113 and IO 113.
27
8 S pumps, range 70
Gr-1016086
+40 °C)
Operation with frequency converter
Only temperature class T3. Fig. 18 Grundfos Dedicated Controls control cabinet
28
S pumps, range 70
8
The communication module enables the possibility for IO 113
Product description
fieldbus protocol (e.g. PROFIBUS DP, Modbus RTU
The IO 113 module is a protection module for Grundfos
and PROFINET IO/Modbus TCP) and the
wastewater pumps.
communication line.
IO 113 has inputs for digital and analog pump sensors
For further information about Grundfos Dedicated
and can stop the pump if a sensor indicates a pump
Controls, please see Grundfos Product Center:
fault.
• Grundfos Dedicated Controls, brochure http://
IO 113 can be connected to the Grundfos Dedicated
net.grundfos.com/qr/i/96925597
Controls system and allows advanced monitoring
• Grundfos iSolutions, brochure http:// functions:
net.grundfos.com/qr/i/99249771
• motor temperature
• Grundfos Controls Guide, product guide http://
• moisture in motor
net.grundfos.com/qr/i/97954965
• water in oil
Additional features, CUE or VFD • insulation resistance.
The CUE/VFD (optional), which is either a Grundfos
variable frequency drive or a general variable SM 113
frequency drive, offers better pump protection and a The SM 113 module is used for collection and transfer
more steady flow through the pipe system. of sensor data in pumps and includes a large number
In addition, Grundfos CUE,VFD offers these features of sensors.
and benefits: SM 113 can be placed either inside the pump (allowing
• Anti-blocking fewer sensor conductors out of the pump) or in the
• Automatic energy optimisation control cabinet next to the pump installation.
• Specific-energy test SM 113 works together with IO 113 through a power-
• Output frequency line communication using the Grundfos GENIbus
• Monitoring of: protocol.
– voltage* SM 113 can collect data from:
– current* • 3 current sensors, 4-20 mA
– phase sequence* • 3 Pt100 thermal sensors or 3 Pt1000 thermal
sensors
– power*
• 1 PTC thermal sensor
– energy*
• 1 digital input.
– torque*
• Reverse start** MP 204
• Run flushing The MP 204 cabinet can be used as a stand-alone
• Stop flushing motor protector. MP 204 may also be incorporated in a
• PID control. Grundfos Dedicated Controls system in which it
* These functions are only available with a Grundfos functions as a motor protector. The pump is protected
CUE. secondarily by measuring the temperature with a
** We do not recommend reversing at full speed at Pt100 sensor and a PTC sensor or thermal switch.
any time. When reduced reverse operation settings
are set, make sure constant torque is enabled in
Variable Frequency Drive (VFD) (i.e. Grundfos
CUE, Siemens Simatic, ABB, Schneider Electric
etc.) to have maximum torque available when
reversing.
Grundfos LC controllers
The LC 231 pump controller is designed for level
control, monitoring and protection of Grundfos
pumping stations featuring one pump or two pumps,
starting direct-on-line. The LC 231 controller is
integrated in a polymer cabinet.
The LC 241 is a modular pump controller that has a
metal or polymer cabinet and can be customised
according to your needs.
It is designed for level control, monitoring and
protection of Grundfos pumping stations featuring one
pump or two pumps, starting direct-on-line with 0-23 A,
star-delta with 0-59 A or soft starter with 0-72 A.
29
8 S pumps, range 70
Product description
Control cabinet
IO 113 SM 113
T1 T2 G1 A1 G2 A2 K1 K2 R1 R2 PE
D1 D2 D3 D4 D5 D6 D7 D8 A Y B
Reset
ON DIP
1 2 3 4 5 6 7 8 9 10
P1 P2 P3 P4 P5 I1 I2 I3 1 2 3 4 5 6 7 8 9 1011 1213 14
Level sensor
SM 113, optional
1 2 3 4 5 6 7 8 9 1011 1213 14
3 3 3
Pt100 in lower bearing
4 4 4
9 1
8 2 5 5 5
7 3 Pt100 in stator
6 6 6
6 4 +t
5
Pt100 in upper bearing
7 7 7
+t
TM06 8753 1117
8 Oil indicator
8 8
4 to 20 mA
9 9 9
30
S pumps, range 70
8
Product description
MP 204
MP 204
Control cabinet
IO 113 SM 113
T1 T2 G1 A1 G2 A2 K1 K2 R1 R2 PE
D1 D2 D3 D4 D5 D6 D7 D8 A Y B
Reset
ON DIP
1 2 3 4 5 6 7 8 9 10
P1 P2 P3 P4 P5 I1 I2 I3 1 2 3 4 5 6 7 8 9 1011 1213 14
Level sensor
SM 113, optional
1 2 3 4 5 6 7 8 9 1011 1213 14
3 3 3
Pt100 in lower bearing
4 4 4
9 1
8 2 5 5 5
7 3 Pt100 in stator
6 6 6
6 4 +t
5
Pt100 in upper bearing
7 7 7
+t
TM06 8754 1117
8 Oil indicator
8 8
4 to 20 mA
9 9 9
31
8 S pumps, range 70
Wiring diagrams
Product description
Motor
Read clockwise
from GND
Pt100 in stator
Thermistor
176c
520d
176a
Stator conductors
TM04 3729 5008
Optional equipment
Pos. Description
1 Female push-on connector
2 Wire pin
3 Butt splice
4 Ring connector
176a Terminal block (power cable connections)
176c Terminal block (sensor connections)
520d Moisture sensor
32
S pumps, range 70
8
Product description
Thermal switch Moisture switch and thermal protectors
Read clockwise
from GND
In Ex pumps 2 moisture switches Motor
Pt100 in stator
Thermistor
176c
520d
176a
Stator conductors
TM04 3274 4008
Optional equipment
Pos. Description
1 Female push-on connector
2 Wire pin
3 Butt splice
4 Ring connector
176a Terminal block (power cable connections)
176c Terminal block (sensor connections)
520d Moisture sensor
33
9 S pumps, range 70
p H
[kPa] [m]
600
S 2.
100
70M.S
60 .2 0
0 .1
.4 .
200 60 Hz
S2. ISO 9906:2012 3B
100
500 50
.200
.10
QH curve for the individual
00.4
. pump
400 40
S2.1
NPSH
45.30
0.110
0.6.
[m]
300 30 15
S2.145.300.1100.6.
200 20 S2.100.200.1200.4. 10
100 10
S2.100.200.1000.4.
5
NPSH curve for all variants
shown. When sizing the
pumps, add a safety margin
0 0 0 of at least 0.5 m.
0 50 100 150 200 250 300 350 400 450 500 550 600 650 Q [l/s]
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [m³/h]
P2
[kW]
120
S2.100.200.1200.4.
S2.145.300.1100.6.
100
80 S2.100.200.1000.4.
Note: The pumps are tested according to ISO 9906:2012 grade 3B tolerance. Testing equipment and measuring
instruments are designed and calibrated according to the standards mentioned. The pumps are approved according to
tolerances for entire curves, specified in grade 3B.
34
S pumps, range 70
9
Curve conditions These tolerance grades can be used in the contract
requirements. 4
Performance acceptance grades Fig. 23 Five measured test points are used to verify one
guarantee point
Six-pump-performance-test acceptance grades, 3B,
2B, 2U, 1B, 1E and 1U are defined in ISO 9906:2012.
Mandatory Optional
Acceptance measurements measurements
grade
Q H P1 Eta-tot
3B ±9% ±7% +9% -7%
2B ±8% ±5% +8%
-5%
2U + 16 % + 10 % + 16 %
1B ±5% ±3% +4% -3%
1E ±5% ±3% +4%
≥ 0%
1U + 10 % +6% + 10 %
Q: Flow
H: Head
P1: Total consumed power
Eta-tot: Total efficiency
35
9 S pumps, range 70
– Q and H, or 50
36
S pumps, range 70
9
In fig. 29, tolerance crosses according to Grade 3B
/RZHUOLPLW
TM07 1515 1618
8SSHUOLPLW
6WDQGDUGFXUYH
Q [m3/h]
37
9 S pumps, range 70
H P1
[m] [kW] checked, individual measurements must be made,
75 150
70 140
which is not part of the performance curve test.
65 130
Static high pressure test
60 120
55 110 All produced pumps undergo a static high pressure
50 100
test of 1.5 x PN (nominal pressure of the pump).
45 90
40 80
35
30
70
60
Specifying acceptance grades
25 50
The graphs in the table on page 39 show the
15 30
10 20
5 10
Acceptance grade U
0 0 This acceptance grade refers to a grade with a
0 100 200 300 Q [l/s] unilateral tolerance on flow rate and head. For the 2U
Fig. 32 Measured values for tested pump grade, there is a tolerance on efficiency. For the 1U
grade, there is no tolerance on efficiency.
H P1
Note that if the acceptance grade changes from Grade
[m] [kW] 1B to 1U, the customer does not necessarily get a
75 150
70 140
better pump with a higher efficiency. More likely, he
65 130 gets a pump where the performance is always to the
60 120 positive side of the guarantee point.
55 110
50 100
45 90
40 80
35 70
30 60
25 50
TM07 1693 2018
20 40
15 30
10 20
5 10
0 0
0 100 200 300 Q [l/s]
38
S pumps, range 70
9
Q: ±9%
Grade 3
Ș Ș: í7%
H H
H: ±5% H: +10%
Q: ±8% Q: +16%
Q Q
Grade 2
Ș Ș: í5% Ș Ș: í5%
Q Q
H H H
H: ±3% H: ±3% H: +6%
Q Q Q
Grade 1
Q Q Q
39
10
Performance curves and technical data
p H
[kPa] [m]
240
70L.S
24
S3.115.500.1400.6.
60 Hz
ISO 9906:2012 3B
200 20
160 16
S3.115.500.800.8. NPSH
[m]
120 12 12
S3.115.500.1400.6.
80 8 8
S3.115.500.800.8.
40 4 4
0 0 0
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 Q [l/s]
800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 Q [m³/h]
P2
[kW]
140 S3.115.500.1400.6.
120
100
80 S3.115.500.800.8.
40
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 Q [l/s]
40
10
160 16
S3.115.500.800.8. NPSH
[m]
120 12 12
S3.115.500.1400.6.
80 8 8
S3.115.500.800.8.
40 4 4
0 0 0
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 Q [l/s]
800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 Q [m³/h]
P2
[kW]
140 S3.115.500.1400.6.
120
100
80 S3.115.500.800.8.
40
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 Q [l/s]
Motor data
Pump data
*
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
41
10
Performance curves and technical data
p H
[kPa] [m]
240
70L.S
24
S3.115.500.1400.6.
60 Hz
ISO 9906:2012 3B
200 20
160 16
S3.115.500.800.8. NPSH
[m]
120 12 12
S3.115.500.1400.6.
80 8 8
S3.115.500.800.8.
40 4 4
0 0 0
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 Q [l/s]
800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 Q [m³/h]
P2
[kW]
140 S3.115.500.1400.6.
120
100
80 S3.115.500.800.8.
40
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 Q [l/s]
42
10
160 16
S3.115.500.800.8. NPSH
[m]
120 12 12
S3.115.500.1400.6.
80 8 8
S3.115.500.800.8.
40 4 4
0 0 0
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 Q [l/s]
800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 Q [m³/h]
P2
[kW]
140 S3.115.500.1400.6.
120
100
80 S3.115.500.800.8.
40
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 Q [l/s]
Motor data
Pump data
* Applies to material code G (see Type key). For other material codes, please contact Grundfos.
43
10
Performance curves and technical data
p H
[kPa] [m]
600
S 2.
100
70M.S
60 .2 0
0 .1
200
.4 .
60 Hz
S2. ISO 9906:2012 3B
100
500 .200
50 .10
00.4
.
400 40
S2.1
NPSH
45.30
0.110
0.6.
[m]
300 30 15
S2.145.300.1100.6.
200 20 S2.100.200.1200.4. 10
S2.100.200.1000.4.
100 10 5
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 Q [l/s]
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [m³/h]
P2
[kW]
120
S2.100.200.1200.4.
S2.145.300.1100.6.
100
80 S2.100.200.1000.4.
60
44
10
400 40
S2.1 NPSH
45.3
00.1
100.6 [m]
300 30 . 15
S2.100.200.1200.4. S2.145.300.1100.6.
200 20 10
S2.100.200.1000.4.
100 10 5
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 Q [l/s]
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [m³/h]
P2
[kW]
120
S2.100.200.1200.4.
S2.145.300.1100.6.
100
S2.100.200.1000.4.
80
40
0 50 100 150 200 250 300 350 400 450 500 550 600 650 Q [l/s]
Motor data
1
Low/high voltage (380/660 V).
Note: Enclosure class: IP68
Pump data
*
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
45
10
Performance curves and technical data
p H
[kPa] [m]
600
S 2.
100
70M.S
60 .2 0
0 .1
200
.4 .
60 Hz
S2. ISO 9906:2012 3B
100
500 .200
50 .10
00.4
.
400 40
S2.1
NPSH
45.30
0.110
0.6.
[m]
300 30 15
S2.145.300.1100.6.
200 20 S2.100.200.1200.4. 10
S2.100.200.1000.4.
100 10 5
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 Q [l/s]
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [m³/h]
P2
[kW]
120
S2.100.200.1200.4.
S2.145.300.1100.6.
100
80 S2.100.200.1000.4.
60
46
10
400 40
S2.1 NPSH
45.3
00.1
100.6 [m]
300 30 . 15
S2.100.200.1200.4. S2.145.300.1100.6.
200 20 10
S2.100.200.1000.4.
100 10 5
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 Q [l/s]
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [m³/h]
P2
[kW]
120
S2.100.200.1200.4.
S2.145.300.1100.6.
100
S2.100.200.1000.4.
80
60
Motor data
Pump data
*
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
47
10
Performance curves and technical data
p H
[kPa] [m]
32 70M.S
S3.120.300.1400.6.
60 Hz
280 28 ISO 9906:2012 3B
240 24 S3.120.300.800.8.
200 20
160 16 NPSH
[m]
120 12 15
80 8 S3.120.300.1400.6. 10
40 4 5
S3.120.300.800.8.
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 Q [l/s]
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [m³/h]
P2
[kW]
140
S3.120.300.1400.6.
120
100
80
S3.120.300.800.8.
60
48
10
100 10
80 8 NPSH
[m]
60 6 10
40 4 8
S3.110.500.800.6.(370)
20 2 6
S3.110.500.650.8.(464)
0 0 4
0 100 200 300 400 500 600 700 800 900 Q [l/s]
80 S3.110.500.800.6.(370)
S3.110.500.650.8.(464)
60
40
Motor data
1
Low/high voltage (380/660 V).
Note: Enclosure class: IP68
Pump data
*
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
49
10
Performance curves and technical data
p H
[kPa] [m]
32 70M.S
S3.120.300.1400.6.
60 Hz
280 28 ISO 9906:2012 3B
240 24 S3.120.300.800.8.
200 20
160 16 NPSH
[m]
120 12 15
80 8 S3.120.300.1400.6. 10
40 4 5
S3.120.300.800.8.
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 Q [l/s]
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [m³/h]
P2
[kW]
140
S3.120.300.1400.6.
120
100
80
S3.120.300.800.8.
40
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 Q [l/s]
50
10
100 10
80 8 NPSH
[m]
60 6 10
40 4 8
S3.110.500.800.6.(370)
20 2 6
S3.110.500.650.8.(464)
0 0 4
0 100 200 300 400 500 600 700 800 900 Q [l/s]
80 S3.110.500.800.6.(370)
S3.110.500.650.8.(464)
60
40
Motor data
Pump data
*
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
51
10
Performance curves and technical data
p H
[kPa] [m]
90 70H.S
800 S2.90.200.1200.4.
60 Hz
80
ISO 9906:2012 3B
700 70 S2.90.200.1000.4.
600 60
500 50
400 40 NPSH
[m]
300 30 12
S2.90.200.1200.4.
200 20 8
S2.90.200.1000.4.
100 10 4
0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [l/s]
100 S2.90.200.1000.4.
80
60
20
0 20 40 60 80 100 120 140 160 180 200 Q [l/s]
52
10
600 60
500 50
400 40 NPSH
[m]
300 30 12
S2.90.200.1200.4.
200 20 8
S2.90.200.1000.4.
100 10 4
0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [l/s]
100
S2.90.200.1000.4.
80
60
20
0 20 40 60 80 100 120 140 160 180 200 Q [l/s]
Motor data
1
Low/high voltage (380/660 V).
Note: Enclosure class: IP68
Pump data
*
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
53
10
Performance curves and technical data
p H
[kPa] [m]
90 70H.S
800 S2.90.200.1200.4.
60 Hz
80
ISO 9906:2012 3B
700 70 S2.90.200.1000.4.
600 60
500 50
400 40 NPSH
[m]
300 30 12
S2.90.200.1200.4.
200 20 8
S2.90.200.1000.4.
100 10 4
0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [l/s]
100 S2.90.200.1000.4.
80
60
20
0 20 40 60 80 100 120 140 160 180 200 Q [l/s]
54
10
600 60
500 50
400 40 NPSH
[m]
300 30 12
S2.90.200.1200.4.
200 20 8
S2.90.200.1000.4.
100 10 4
0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [l/s]
100
S2.90.200.1000.4.
80
60
20
0 20 40 60 80 100 120 140 160 180 200 Q [l/s]
Motor data
Pump data
* Applies to material code G (see Type key). For other material codes, please contact Grundfos.
55
10
Performance curves and technical data
p H
[kPa] [m]
50 70H.S
S2.12
450 2.250
45 .1400
.6. 60 Hz
S2.1 ISO 9906:2012 3B
400 22.2
40 50.1
S2.1 100
05.2 .6.
350 35 50.8
00.8
.
300 30
250 25
200 20
NPSH
[m]
150 15 12
100 10 8
50 5 S2.122.250.1100.6. 4
S2.122.250.1400.6.
0 0 0
0 50 100 150 200 250 300 350 400 450 500 Q [l/s]
80 S2.105.250.800.8.
60
56
10
250 25
200 20
NPSH
[m]
150 15 12
100 10 8
S2.122.250.1400.6.
50 5 S2.122.250.1100.6. 4
0 0 0
0 50 100 150 200 250 300 350 400 450 500 Q [l/s]
80 S2.105.250.800.8.
40
0 50 100 150 200 250 300 350 400 450 500 Q [l/s]
Motor data
I N1 Istart η motor [%] Cos φ Moment Breakdown
P1 P2 No. of Starting
Pump type RPM of inertia torque Mmax
[kW] [kW] poles method [A] [A] 1/2 3/4 1/1 1/2 3/4 1/1 [kgm2] [Nm]
S2.105.250.800.8.70H.S.523... 86 80 8 882 Y/D 156/90 1042 93 94 93 0.77 0.83 0.84 2.1000 2170
S2.105.250.800.8.70H.C.523... 86 80 8 882 Y/D 156/90 1042 93 94 93 0.77 0.83 0.84 2.1000 2170
S2.105.250.800.8.70H.D.523... 86 80 8 882 Y/D 156/90 1042 93 94 93 0.77 0.83 0.84 2.1000 2170
S2.105.250.800.8.70H.H.523... 86 80 8 882 Y/D 156/90 1042 93 94 93 0.77 0.83 0.84 2.1000 2170
S2.122.250.1100.6.70H.S.443... 118 110 6 1181 Y/D 230/132 1543 89 90 90 0.73 0.80 0.81 2.1000 2223
S2.122.250.1100.6.70H.C.443... 118 110 6 1181 Y/D 230/132 1543 89 90 90 0.73 0.80 0.81 2.1000 2223
S2.122.250.1100.6.70H.D.443... 118 110 6 1181 Y/D 230/132 1543 89 90 90 0.73 0.80 0.81 2.1000 2223
S2.122.250.1100.6.70H.H.443... 118 110 6 1181 Y/D 230/132 1543 89 90 90 0.73 0.80 0.81 2.1000 2223
S2.122.250.1400.6.70H.S.465... 152 140 6 1186 Y/D 276/159 2395 92 92 92 0.67 0.78 0.84 2.8000 2930
S2.122.250.1400.6.70H.C.465... 152 140 6 1186 Y/D 276/159 2395 92 92 92 0.67 0.78 0.84 2.8000 2930
S2.122.250.1400.6.70H.D.465... 152 140 6 1186 Y/D 276/159 2395 92 92 92 0.67 0.78 0.84 2.8000 2930
S2.122.250.1400.6.70H.H.465... 152 140 6 1186 Y/D 276/159 2395 92 92 92 0.67 0.78 0.84 2.8000 2930
1
Low/high voltage (380/660 V).
Note: Enclosure class: IP68
Pump data
Impeller Maximum solids Pump housing Maximum
Moment of inertia*
Pump type diameter size pressure installation depth
57
10
Performance curves and technical data
p H
[kPa] [m]
50 70H.S
S2.12
450 2.250
45 .1400
.6. 60 Hz
S2.1 ISO 9906:2012 3B
400 22.2
40 50.1
S2.1 100
05.2 .6.
350 35 50.8
00.8
.
300 30
250 25
200 20
NPSH
[m]
150 15 12
100 10 8
50 5 S2.122.250.1100.6. 4
S2.122.250.1400.6.
0 0 0
0 50 100 150 200 250 300 350 400 450 500 Q [l/s]
80 S2.105.250.800.8.
60
58
10
250 25
200 20
NPSH
[m]
150 15 12
100 10 8
S2.122.250.1400.6.
50 5 S2.122.250.1100.6. 4
0 0 0
0 50 100 150 200 250 300 350 400 450 500 Q [l/s]
80 S2.105.250.800.8.
40
0 50 100 150 200 250 300 350 400 450 500 Q [l/s]
Motor data
Pump data
Maximum solids Pump housing Maximum
Impeller diameter Moment of inertia*
Pump type size pressure installation depth
59
11 S pumps, range 70
11. Accessories
Accessories
Weight Product
Pictures Description Size PN
[kg] number
Outlet flange
with: DN 250 225 96782483
• guide claw 1
10
• base unit
• upper guide rail bracket DN 300 275 96782484
GR8126
Intermediate guide rail bracket For guide rails longer than 6 m DN 200-600 8 96255842
Standard pipes.
Guide rails
Not supplied by Grundfos
DN 250 90 96308240
TM04 3693 4908 TM03 2015 3505
Steel, epoxy-coated.
Base plate for vertical, dry installation with:
DN 300 87 96308241
• gaskets
Inlet flange
• bolts.
DN 500 167 96308245
• S2.105.250.800.8.70H.H
Version 1 140 96308192
• S3.115.500.1400.6.70L.H
• S3.115.500.800.8.70L.H
• S3.120.300.1400.6.70M.H
• S3.120.300.800.8.70M.H
60
S pumps, range 70
11
Accessories
Weight Product
Pictures Description Size PN
[kg] number
Bend
Pipe/pump inlet
Cast iron, epoxy-coated
10
L = 500 mm DN 400 148 99036000
L
L = 500 mm DN 500 351 99036001
Reducing bend
Pipe/pump inlet
Cast iron, epoxy-coated
10
L = 500 mm DN 400/DN 300 128 99036014
61
11 S pumps, range 70
Other accessories
Accessories
Product
Pictures Description Size
number
4m 98425788
Galvanised lifting chain with lifting link and safety hook. 6m 98425789
Certified.
Maximum lifting capacity 3200 kg. 8m 98425790
10 m 98425791
4m 98425805
TM02 6126 5102
Stainless steel lifting chain with lifting link and safety hook. 6m 98425806
Certified.
Maximum lifting capacity 3200 kg. 8m 98425807
10 m 98425808
Contact
TM06 4974 3415
10 m cable 96003332
Float switch
TM02 8862 0904 TM01 6982 3999
20 m cable 96003695
10 m cable 96003421
Float switch for use in potentially explosive environments.
20 m cable 96003536
For 38 mm mounting
Bracket for level electrodes 91713196
pipe
62
S pumps, range 70
12
12. Dimensions
Dimensions
Recommendation for pump foundations
Note: This applies only to pumps above 15 kW. • The foundation must be 15 cm wider than the base
All rotating equipment generates vibrations as a mass, plate for pumps up to 350 kW and 25 cm wider for
such as an impeller or rotor, is turning at high speeds. larger pumps.
Proper installation and anchorage of Grundfos pumps • The concrete used in the foundation must have a
and installation accessories is critical to limit vibrations minimum tensile strength of 250 N/cm 2. Epoxy grout
and achieve reliable, trouble-free installation. It is must always be used to secure the pump base plate
important to note that all mechanically connected to the foundation.
pipes, fittings and supports to the pump are part of a
single system. Pull-out strengths for anchor bolts
The rotating mass of the entire pump, together with the Submerged installation on auto-coupling (type S and
forces from the motor and hydraulics, will generate C):
disturbances related to the speed of the motor.
Unbalance and impeller vane pass in hydraulics are Auto-coupling base Pull-out resistance
Anchor bolts
unit [kN]
the two most important frequencies affecting vibration.
DN 100 5
When these frequencies coincide with the natural 4 x M16
DN 125/DN 150 1 8
frequency of the entire mechanical system, the DN 200 16
vibration level will increase substantially. DN 250 4 x M24 30
Pumps from Grundfos are designed and produced DN 300 40
according to the highest quality standards. The method DN 500 40
6 x M30
DN 600 40
and grade of balancing is specified by the
manufacturer in order to achieve acceptable vibration 1 Pump outlet DN 125 and base plate outlet DN 150.
levels. Although the pump itself can withstand rather Dry installation (type H and D):
high vibration levels under operating conditions without
considerable lifetime reduction, the pipes and Dry installation Anchor bolts
Pull-out resistance
[kN]
supportive structure might suffer and crack if vibration
levels are too high. Furthermore, noticeable noise DN 100 3 x M20 18
DN 150 18
levels might be generated. 6 x M20
DN 200 18
The likelihood of high vibration levels occurring is DN 250 25
increased in variable-speed applications where the DN 300 25
6 x M24
pump is operated over a range of speeds rather than DN 500/DN 4001 25
at a single constant speed. Most variable-speed drives DN 500 25
provide the possibility to exclude certain frequency 1
Base plate inlet DN 500 and pump inlet DN 400.
ranges to avoid operating areas with high vibrations.
To ensure acceptable vibration levels in the field, all
parts of the system must be sufficiently stiff and firmly
anchored to minimise vibrations:
• The foundation and concrete must be of adequate
strength to support the weight of the pump including
accessories, the weight of the liquid passing
through the pump and the forces generated by the
pump.
• As a rule of thumb, the mass of the concrete
foundation must be a minimum of three to five times
the mass of the supported equipment and must
have sufficient rigidity to withstand the axial,
transverse and torsional loadings generated by the
equipment.
63
12 S pumps, range 70
Basic pump
Dimensions
MOT_H
DN2
H DC02
HYDR_H
E
DC10
D01 x D1N
MOT_H
A
TM04 2412 2018 - TM07 1653 2018
D02 x D2N
DN2
DC02
E DN1
HYDR_H
C
64
S pumps, range 70
12
Note: Dimensions D01, D1N, DC10 and DN1 are equal to zero for installation types C and S because of the inlet type.
Dimensions
HYDR MOT MOT
Pump type A C D D01 D02 D1N D2N DC02 DC10 DN1 DN2 DT2 E F H
H H Hfix
S2.90.200.1000.4.70H.C 1625 770 285 - 24 - 8 295 - - DN 200 26 500 570 203 305 1320 20
S2.90.200.1000.4.70H.D 1638 770 285 M20 24 12 8 295 350 DN 250 DN 200 26 500 570 226 318 1320 20
S2.90.200.1000.4.70H.H 1638 770 285 M20 24 12 8 295 350 DN 250 DN 200 26 500 570 226 318 1320 20
S2.90.200.1000.4.70H.S 1625 770 285 - 24 - 8 295 - - DN 200 26 500 570 203 305 1320 20
S2.90.200.1200.4.70H.C 1625 970 285 - 24 - 8 295 - - DN 200 26 700 570 203 305 1320 20
S2.90.200.1200.4.70H.D 1638 770 285 M20 24 12 8 295 350 DN 250 DN 200 26 500 570 226 318 1320 20
S2.90.200.1200.4.70H.H 1638 770 285 M20 24 12 8 295 350 DN 250 DN 200 26 500 570 226 318 1320 20
S2.90.200.1200.4.70H.S 1625 970 285 - 24 - 8 295 - - DN 200 26 700 570 203 305 1320 20
S2.100.200.1000.4.70M.C 1638 809 400 - 24 - 8 295 - - DN 200 26 460 720 215 318 1320 20
S2.100.200.1000.4.70M.D 1638 809 400 M20 24 12 8 295 350 DN 250 DN 200 26 460 720 215 318 1320 20
S2.100.200.1000.4.70M.H 1638 809 400 M20 24 12 8 295 350 DN 250 DN 200 26 460 720 215 318 1320 20
S2.100.200.1000.4.70M.S 1638 809 400 - 24 - 8 295 - - DN 200 26 460 720 215 318 1320 20
S2.100.200.1200.4.70M.S 1638 809 400 - 24 - 8 295 - - DN 200 26 460 720 215 318 1320 20
S2.100.200.1200.4.70M.D 1638 809 400 M20 24 12 8 295 350 DN 250 DN 200 26 460 720 215 318 1320 20
S2.100.200.1200.4.70M.H 1638 809 400 M20 24 12 8 295 350 DN 250 DN 200 26 460 720 215 318 1320 20
S2.100.200.1200.4.70M.S 1638 809 400 - 24 - 8 295 - - DN 200 26 460 720 215 318 1320 20
S2.105.200.800.8.70H.C 1719 1193 478 - 24 - 12 350 - - DN 250 30 750 891 235 369 1350 20
S2.105.200.800.8.70H.D 1773 1193 478 M20 24 12 12 250 400 DN 300 DN 250 30 750 891 289 423 1350 20
S2.105.200.800.8.70H.H 1773 1193 478 M20 24 12 12 250 400 DN 300 DN 250 30 750 891 289 423 1350 20
S2.105.200.800.8.70H.S 1719 1193 478 - 24 - 12 350 - - DN 250 30 750 891 235 369 1350 20
S2.122.250.1100.6.70H.C 1689 1193 478 - 24 - 12 350 - - DN 250 30 450 891 235 369 1320 20
S2.122.250.1100.6.70H.D 1743 1193 478 M20 24 12 12 250 400 DN 300 DN 250 30 450 891 289 423 1320 20
S2.122.250.1100.6.70H.H 1743 1193 478 M20 24 12 12 250 400 DN 300 DN 250 30 450 891 289 423 1320 20
S2.122.250.1100.6.70H.S 1689 1193 478 - 24 - 12 350 - - DN 250 30 450 891 235 369 1320 20
S2.122.250.1400.6.70H.C 1844 1193 478 - 24 - 12 350 - - DN 250 30 750 891 235 369 1475 20
S2.122.250.1400.6.70H.D 1898 1193 478 M20 24 12 12 350 400 DN 300 DN 250 30 750 891 289 423 1475 20
S2.122.250.1400.6.70H.H 1898 1193 478 M20 24 12 12 350 400 DN 300 DN 250 30 750 891 289 423 1475 20
S2.122.250.1400.6.70H.S 1844 1193 478 - 24 - 12 350 - - DN 250 30 750 891 235 369 1475 20
S2.145.300.1100.6.70M.C 1915 1139 522 - 24 - 12 400 - - DN 300 33 700 907 450 595 1320 20
S2.145.300.1100.6.70M.D 1743 1139 522 M20 24 12 12 400 400 DN 300 DN 300 33 700 907 278 278 1320 20
S2.145.300.1100.6.70M.H 1743 1139 522 M20 24 12 12 400 400 DN 300 DN 300 33 700 907 278 278 1320 20
S2.145.300.1100.6.70M.S 1915 1139 522 - 24 - 12 400 - - DN 300 33 700 907 450 595 1320 20
S3.115.500.800.8.70L.C 1830 1743 719 - 27 - 20 620 - - DN 500 37 1200 1269 380 510 1320 20
S3.115.500.800.8.70L.D 1783 1743 719 M24 27 16 20 620 515 DN 400 DN 500 37 1200 1269 333 463 1320 20
S3.115.500.800.8.70L.H 1783 1743 719 M24 27 16 20 620 515 DN 400 DN 500 37 1200 1269 333 463 1320 20
S3.115.500.800.8.70L.S 1830 1743 719 - 27 - 20 620 - - DN 500 37 1200 1269 380 510 1320 20
S3.115.500.1400.6.70L.C 1985 1843 719 - 27 - 20 620 - - DN 500 37 1200 1269 380 510 1475 20
S3.115.500.1400.6.70L.D 1938 1843 719 M24 27 16 20 620 515 DN 400 DN 500 37 1200 1269 333 463 1475 20
S3.115.500.1400.6.70L.H 1938 1843 719 M24 27 16 20 620 515 DN 400 DN 500 37 1200 1269 333 463 1475 20
S3.115.500.1400.6.70L.S 1985 1843 719 - 27 - 20 620 - - DN 500 37 1200 1269 380 510 1475 20
S3.120.300.800.8.70M.C 1915 1139 522 - 24 - 12 400 - - DN 300 33 700 907 450 595 1320 20
S3.120.300.800.8.70M.D 1743 1139 522 M20 24 12 12 400 400 DN 300 DN 300 33 700 907 278 423 1320 20
S3.120.300.800.8.70M.H 1743 1139 522 M20 24 12 12 400 400 DN 300 DN 300 33 700 907 278 423 1320 20
S3.120.300.800.8.70M.S 1915 1139 522 - 24 - 12 400 - - DN 300 33 700 907 450 595 1320 20
S3.120.300.1400.6.70M.C 2070 1139 522 - 24 - 12 400 - - DN 300 33 700 907 450 595 1475 20
S3.120.300.1400.6.70M.D 1898 1139 522 M20 24 12 12 400 400 DN 300 DN 300 33 700 907 278 423 1475 20
S3.120.300.1400.6.70M.H 1898 1139 522 M20 24 12 12 400 400 DN 300 DN 300 33 700 907 278 423 1475 20
S3.120.300.1400.6.70M.S 2070 1139 522 - 24 - 12 400 - - DN 300 33 700 907 450 595 1475 20
65
12 S pumps, range 70
Auto-coupling X
Product number Size [mm]
96641489 DN 200
96782483 DN 250
150
96782484 DN 300
96782485 DN 500
Auto-coupling dimensions
G C
A H I J
E D K
Dimensions [mm]
Product number Size
A B C D E F G H I J K
96641489 DN 200 485 710 365 535 89 86 175 500 430 430 710
96255838 DN 250 545 753 375 565 89 86 175 540 470 470 745
96782484 DN 300 650 860 450 670 80 95 175 620 550 550 845
96782485 DN 500 890 1148 564 735/150 1 127 99 226 720 660 660 1120
1
Six bolt installation: distance between the front bolt hole and the middle bolt hole / distance between the middle bolt hole and the back bolt hole.
66
S pumps, range 70
12
Pump installation dimensions
Dimensions
ZDN1 C
Z01
c1
ZD
Z2 Z3
F
Z4
Z6
Z7
Z8
Z9
Z10
Z17G
Z17S Installation S
Ex pump
ZL1
Z15 ZL2
ZDT1
Installation S
Std. pump Z1
Installation C Z23 Z11
S3OPR
Z12B
ZM Z14
Fig. 37 Installation on auto-coupling system - version 1 (base unit with 4 anchor bolts)
Note: Z12A is the minimum recommended distance from pit bottom to bottom of pump inlet side.
Note: Z11 is the total height of pump installed on Grundfos accessory in the pit.
Note: The pump in this figure might not equal Z12A + Z1.
67
12 S pumps, range 70
Dimensions
68
S pumps, range 70
12
Dimensions
C
ZDN1
Z01
Z3 F
Z2
ZDC1 Z4
Z6
Z7
Z8
Z9
Z10
Z17G
Installation S
Z17S
ZL1 Ex pump
Z15 ZL2
ZDT1 Installation S
Std. pump
Z1
Installation C Z11
S3OPR Z23
Z16
Z12B
ZM Z5 Z14
Fig. 38 Installation on auto-coupling system - version 2 (base unit with 6 anchor bolts)
Note: Z12A is the minimum recommended distance from pit bottom to bottom of pump inlet side.
Note: Z11 is the total height of pump installed on Grundfos accessory in the pit.
Note: The pump in this figure might not equal Z12A + Z1.
69
12 S pumps, range 70
X1
X02
DN2
XDC2
X16
XM1
X2
X3
X6
X7
X8
X12 X04
X03
X11
X9
X11 C
E
TM04 2424 2018
X10
XDC3
70
S pumps, range 70
12
Dimensions
Pump type C E ∅ X02 ∅ X03 ∅ X04 X1 X2 X3 X6 X7 X8
S2.90.200.1000.4.70H.D 770 500 24 23 28 1638 249 20 700 500 900
S2.90.200.1200.4.70H.D 770 500 24 23 28 1638 249 20 700 500 900
S2.100.200.1000.4.70M.D 809 460 24 23 28 1638 238 20 700 500 900
S2.100.200.1200.4.70M.D 809 460 24 23 28 1638 238 20 700 500 900
S2.105.250.800.8.70H.D 1193 750 24 23 28 1743 312 20 800 600 900
S2.122.250.1100.6.70H.D 1193 750 24 23 28 1743 312 20 800 600 900
S2.122.250.1400.6.70H.D 1193 750 24 23 28 1898 312 20 800 600 900
S2.145.300.1100.6.70M.D 1139 700 24 23 28 1743 301 20 800 600 900
S3.115.500.800.8.70L.D 1843 1200 27 27 28 1783 496 160 1450 850 1180
S3.115.500.1400.6.70L.D 1843 1200 27 27 28 1938 496 160 1450 850 1180
S3.120.300.800.8.70M.D 1139 700 24 23 28 1743 301 20 800 600 900
S3.120.300.1400.6.70M.D 1139 700 24 23 28 1898 301 20 800 600 900
Pump type X9 X10 X11 X12 X16 DT2 XDC2 XDC3 DN2 XM1
S2.90.200.1000.4.70H.D 700 DN 250 300 800 2358 28 295 350 DN 200 6 x M24
S2.90.200.1200.4.70H.D 700 DN 250 300 800 2358 28 295 350 DN 200 6 x M24
S2.100.200.1000.4.70M.D 700 DN 250 300 800 2358 28 250 350 DN 200 6 x M24
S2.100.200.1200.4.70M.D 700 DN 250 300 800 2358 28 295 350 DN 200 6 x M24
S2.105.250.800.8.70H.D 700 DN 300 300 800 2563 28 350 400 DN 250 6 x M24
S2.122.250.1100.6.70H.D 700 DN 300 300 800 2563 28 350 400 DN 250 6 x M24
S2.122.250.1400.6.70H.D 700 DN 300 300 800 2718 28 350 400 DN 250 6 x M24
S2.145.300.1100.6.70M.D 700 DN 300 300 800 2563 28 400 400 DN 300 6 x M24
S3.115.500.800.8.70L.D 700 DN 400 300 1100 3393 34 620 620 DN 500 6 x M24
S3.115.500.1400.6.70L.D 700 DN 400 300 1100 3548 34 620 620 DN 500 6 x M24
S3.120.300.800.8.70M.D 700 DN 300 300 800 2563 28 400 400 DN 300 6 x M24
S3.120.300.1400.6.70M.D 700 DN 300 300 800 2718 28 400 400 DN 300 6 x M24
71
12 S pumps, range 70
DN2
Ø DC2
D2N
D2NxxØD02
D02
Q2 DT2
QDN1
Ø QDC1
QZ2
QZ3
Q3
D1N xD1N
Q01x Q01
Q4
QZ4
Q9 Q10
Q1
Q5 Q6 Q7
Q8
F
D
TM04 2415 2018
ØQ03
Ø Q03
72
S pumps, range 70
12
Dimensions
Pump type D F Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10
S2.90.200.1000.4.70H.H 285 570 1638 226 1300 800 395 600 600 700 288 1357
S2.90.200.1200.4.70H.H 285 570 1638 226 1300 800 395 600 600 700 288 1357
S2.100.200.1000.4.70M.H 400 720 1638 215 1260 800 395 600 600 700 288 1357
S2.100.200.1200.4.70M.H 400 720 1638 215 1260 800 395 600 600 700 288 1357
S2.105.250.800.8.70H.H 478 891 1743 289 1550 800 500 600 600 700 393 1357
S2.122.250.1100.6.70H.H 478 891 1743 289 1550 800 500 600 600 700 393 1357
S2.122.250.1400.6.70H.H 478 891 1898 289 1550 800 500 600 600 700 393 1357
S2.145.300.1100.6.70M.H 522 907 1743 278 1500 800 500 600 600 700 393 1357
S3.115.500.800.8.70L.H 719 1269 1783 333 2000 800 540 600 600 700 433 1357
S3.115.500.1400.6.70L.H 719 1269 1938 333 2000 800 540 600 600 700 433 1357
S3.120.300.800.8.70M.H 522 907 1743 278 1500 800 500 600 600 700 393 1357
S3.120.300.1400.6.70M.H 522 907 1898 278 1500 800 500 600 600 700 393 1357
Pump type ∅ QDC1 QDN1 D1N Q01 DN2 D2N D02 DC02 DT2 ∅ Q03 QZ2 QZ3 QZ4
S2.90.200.1000.4.70H.H 350 DN 250 12 M20 DN 200 8 24 295 26 28 338 -50 107
S2.90.200.1200.4.70H.H 350 DN 250 12 M20 DN 200 8 24 295 26 28 338 -50 107
S2.100.200.1000.4.70M.H 350 DN 250 12 M20 DN 200 8 24 295 26 28 338 -50 107
S2.100.200.1200.4.70M.H 350 DN 250 12 M20 DN 200 8 24 295 26 28 338 -50 107
S2.105.250.800.8.70H.H 400 DN 300 12 M20 DN 250 12 24 350 30 28 443 -50 107
S2.122.250.1100.6.70H.H 400 DN 300 12 M20 DN 250 12 24 250 30 28 443 -50 107
S2.122.250.1400.6.70H.H 400 DN 300 12 M20 DN 250 12 24 350 30 28 443 -50 107
S2.145.300.1100.6.70M.H 400 DN 300 12 M20 DN 300 12 24 400 33 28 443 -50 107
S3.115.500.800.8.70L.H 515 DN 400 16 M24 DN 500 20 27 620 37 28 483 -50 107
S3.115.500.1400.6.70L.H 515 DN 400 16 M24 DN 500 20 27 620 37 28 483 -50 107
S3.120.300.800.8.70M.H 400 DN 300 12 M20 DN 300 12 24 400 33 28 443 -50 107
S3.120.300.1400.6.70M.H 400 DN 300 12 M20 DN 300 12 24 400 33 28 443 -50 107
73
13 S pumps, range 70
13. Weights
Weights
74
S pumps, range 70
14
Flange forces
The flange forces and moments are according to EN
Horizontal installations
ISO 5199.
Z Forces can be found for both horizontal and vertical
installations in table B.3 in EN ISO 5199, by selecting
the correct flange dimension. Forces cannot be used
Y directly for end-suction wastewater pumps without
using a coefficient which can be found in table B.5 in
EN ISO 5199 by selecting the correct pump family.
Z For Grundfos wastewater pumps the pump families
Y and coefficients are as stated below.
Horizontally installed pumps
Pump family A4 = Coefficient 0.35
X
Vertically installed pumps
Pump family 10A = Coefficient 0.30
Vertical installations
X
Base unit
Z
TM06 4901 3115 - TM06 4903 3115 - TM06 4902 3115
75
15 S pumps, range 70
Online search and sizing tool to help you make the right choice.
http://product-selection.grundfos.com
TM07 2384
instructions, data booklets, service instructions, etc. in PDF format.
2 3 4 5
TM07 2383
Pos. Description
1 This drop-down menu enables you to set the search function to "Products" or "Literature".
2 SIZING enables you to size a pump based on entered data and selection choices.
3 CATALOGUE gives you access to the Grundfos product catalogue.
REPLACEMENT enables you to find a replacement product.
Search results will include information on
4 the lowest purchase price
the lowest energy consumption
the lowest total life cycle cost.
5 LIQUIDS enables you to find pumps designed for aggressive, flammable or other special liquids.
76
77
78
79
ECM: 1307628
GRUNDFOS A/S
96846146 01.2021
www.grundfos.com
Telephone: +45 87 50 14 00
DK-8850 Bjerringbro . Denmark
Trademarks displayed in this material, including but not limited to Grundfos, the Grundfos logo and “be think innovate” are registered trademarks owned by The Grundfos Group. All rights reserved. © 2021 Grundfos Holding A/S, all rights reserved.