Professional Documents
Culture Documents
TS1V4A - Desalinhamento Elevador
TS1V4A - Desalinhamento Elevador
TS1V4A - Desalinhamento Elevador
TS1V3A/TS1V4A TS1V3A/TS1V4A
BRAIME BRAIME
Liability and Indemnity
Neither the Company nor its suppliers shall in any circumstances whatsoever be
liable for any loss or damage suffered by the Buyer or by any third party howsoever
caused involving any person, property or interest, suffered by the Buyer or any third
party directly or indirectly in connection with the use, functioning or state of the goods,
unless the same shall arise out of the Company’s negligence.
The Buyer shall indemnify the Company against all actions, claims or demands
by third parties, whether in tort or otherwise, howsoever arising, directly or indirectly,
in connection with the use, functioning or state of the goods or in connection with the
performance of service.
Limitation of Liability
⇒ For any incidental or consequential loss or damage suffered by the buyer, including,
without limitation, delay, detention, loss of production, loss of profit or liability to
third parties except liability for personal injury or death arising out of negligence by
the Company. ATEX Zone 20 approved
⇒ For any loss or damage covered by insurance or which would ordinarily be covered
by insurance. II 1D T120°C Tamb -15 to 45°C
Certificate n° Baseefa01ATEX1192X
Warranty
II 2D T80°C Tamb -15 to 45°C
The equipment is covered by a 12 month warranty from the date of dispatch.
Any faults arising due to faulty materials or workmanship in the original equipment Certificate n° Baseefa01ATEX2193X
within the warranty period will be corrected free of charge providing the equipment is
returned to us freight paid.
1180 IP66
October 2007
BRAIME ELEVATOR COMPONENTS LTD. - Hunslet Road - Leeds LS 10 1JZ - ENGLAND BRAIME ELEVATOR COMPONENTS LTD. - Hunslet Road - Leeds LS 10 1JZ - ENGLAND
Tel: +44 (0) 113 246 1800 Fax: +44 (0) 113 243 5021 Tel: +44 (0) 113 246 1800 Fax: +44 (0) 113 243 5021
Email: 4b-uk@go4b.com www.go4b.com Email: 4b-uk@go4b.com www.go4b.com
Wiring / Set-Up and Test
All wiring must be in accordance with the local and National Electrical Codes and
should be undertaken by an experienced and professional, qualified electrician
Mount a suitable junction box within 2m of the sensor, and using a suitable gland
to bring the cable into the box, make the necessary wiring connections inside this junc-
tion box. A 2m long PVC coated cable connected to the sensor contains the following
22 AWG wires :
Note: The TouchSwitch contains a non repairable 160mA fuse and thermal fuses set at
73°C. Should the sensor body reach 73°C or higher then the thermal fuses may fail.
Note: The relay contact is energized when power is supplied and de-energizes when the
sensor detects the belt or pulley. Relay contact closed between White and Blue when
unit is powered and Led is on .
Observe that the red Led on the sensor housing is on and the belt or pulley is
not touching the sensor. Slowly turn the test knob clockwise by hand, until the LED
goes out. Check the alarms and shutdowns work as expected. Turn the test knob back
to its original position. Observe that the LED is now on.
Periodically test the sensor and system, and visually inspect the contact surface
of the sensor.
Warning Z
Use shielded cable and keep separate from high voltage cables
Never run the TouchSwicth cables in the same conduit as 3-phase motor cables
Never weld near or around the TouchSwitch
Track belts and commission plant prior to installing TouchSwitch
7 October 2007
Installation Introduction
Test knob 4 x M6
Led
Calibration Seal
Test knob
TS2 - Conduit Entry Version -
Available
Enclosed Belt
6 x 22AWG conductors Conveyor
2 m long cable Application
TS1 - Cable Version -
1/2’’ NPT
Conduit Entry
(TS2 Version)
Correct Mounting
Supply Voltage: 12Vdc (TS1V3A) 24Vdc (TS1V4A)
Power Consumption: 60mA 50mA Elevator casing
Indication : Red Led indicates when powered up and relay is energized.
Adjustment : Force Sensitivity is factory set to 8 lb (3.6Kg) approx.
Output : Voltage free changeover relay contact rated at 5A 250Vac Rubber
Non-Inductive Gasket
Body Construction: Pressed seamless steel with epoxy paint
Face Construction: Hardened and annealed stainless steel
Entry: Cable Entry
Cable Length: 2 m (9ft) Belt
TS
Conductors : 6 at 22 awg (see ‘wiring’ p7) TS
Weight : 3 lb (1.36kg) Pulley
Approvals: ATEX zone 20 Ex II 1D T120 °C et Ex II 2D T80°C
Protection: NEMA 4X IP66 Bucket
Dimensions: 45mm x 86mm (See drawing) / 3.4" Diameter x 1.75" Deep
Up-Side Down-Side
leg leg
WarningZ
Don’t put the TouchSwitch on the bolt or buckets
Warning Z
TouchSwitch Wiring is Low
Voltage DC. Incorrect Mounting
Red LED TS
Don’t exceed 27 Vdc power
Belt
to the TouchSwitch
Test Knob
Bucket
TS
Calibration Seal
TS