AcuDC 240 Series

Multifunction Power & Energy Meter


AcuDC 240 series power meter can be used for monitoring and controlling in DC
systems. These meters can measure a wide range of parameters such as voltage,
current, power and energy.
It supports bi-directional current measurement, digital inputs for switch monitoring
and relay outputs for remote controlling as well as an over-range alarming feature
for voltage and current. Large signals, such as voltage and current can be
converted to smaller signal using analog output. All data in the meter is accessible
via RS485 using open Modbus RTU protocol.
The large 3 line LCD display also provides easy to read real-time data directly on
the meter front.

Features
• DC power system metering
• Monitor and control power switches
• Alarming and analog output
• Standard 72x72mm, allows for drawer type panel installation
• Three line high-definition LCD display
• Accessible with SCADA, PLC systems
• Easy installation, simple wiring
• Data Logging: Offers 3 assignable historical logs where the all of
the metering parameters can be recorded.
• The onboard memory is up to 4 MB and each log size is adjustable.

Aplications • Wind Power Generation


• DC Energy Management Systems • DC Excitation Systems
• Power Distribution for Telecommunication Room • Light Rail Transit Systems
• Solar Photovoltaic Systems • EV Charging Monitoring
• Industrial DC Control Systems • Data Center
• Metallurgy and Electroplating Industries • Cellular Tower Energy Monitoring

Specifications

Category Function AcuDC 241 AcuDC 242 AcuDC 243

Voltage V
METERING Current I
Power P
Energy E
Ampere-hour Ah
2DI+2AO
I/O
2DI+2RO Support DI
2DI+2DO count
2DI+ ±15Vdc

DATALOGGING All metering parameters can be recorded (Voltage,


Current, Power, Energy, Ampere-hour, DI Count);
Interval 1 minute; Can record 4 months
COMMUNICATION RS485 , Modbus RTU
DISPLAY LCD

DIMENSIONS 72×72×64.5mm (Cutout: 68×68 mm) / 2.835×2.835×2.539 inch (Cutout: 2.677×2.677 inch)

Note: Standard; Optional Blank: Not Available

Hoyt Electrical Instrument Works, Inc. Phone: (800) 258-3652 www.hoytmeter.com


23 Meter Street Fax: (603) 753-9592 Page 1 (4)
Penacook, NH 03303 Email: sales@hoytmeter.com
AcuDC 240 Series
Multifunction Power & Energy Meter

Dimensions
51.7(2.035)
Unit: mm (inch) I/O Module Unit: mm (inch)

18.0(0.709)

72.0(2.835)
67.0(2.638)

68.0(2.677)
72.0(2.835)

Cut-Out

51.4(2.024)

51.4(2.024)
72.0(2.835) 12.8(0.504) 68.0(2.677) 65.5(2.579)

FRONT SIDE PANEL CUTOUT

Typical Wiring
Vdc+ Vdc- Vdc+ Vdc- Vdc+ Vdc-

±15 External
DC Power

IN+ + AcuDC 240


G
_
6 I- 1 U+
IN- M 1 U+
AcuDC 240 AcuDC 240
G 3 U-
5 I+ 3 U-

Load

Voltage Wiring using


Current Direct Wiring Voltage Direct Wiring
NOTE:
±15V power supply from the X5 module.

Vdc+ Vdc- Vdc+ Vdc- Vdc+ Vdc- Vdc+ Vdc-

+
IN+ _ G
1 U+
IN- M 1 U+
3 U-
±15 External
1 U+ 1 U+ DC Power G 3 U-
±15 External
+ AcuDC 240 DC Power
3 U- 3 U- G
Current Hall

_ + AcuDC 240
AcuDC 240 AcuDC 240
Shunt 75mV

Current Hall

_ G
5 I+ 6 I- M 5 I+
M 5 I+
6 I- 5 I+ G 6 I- G 6 I-
Load
External DC Power
Load Load Load

Voltage & Current Direct Wiring Voltage & Current Wiring using Shunt Voltage & Current Wiring using Current Voltage & Current Wiring using Hall

NOTE: A physical jumper from terminal 3 to 6 must be NOTE: NOTE:


connected. ±15V power supply in the X5 module. ±15V power supply from the X5 module.

AcuDC 240 AcuDC 240 AcuDC 240 External Power Supply

AC / DC
R11

21
DI11 DI12 DI21 DI22

AO1- AO1+ AO2- AO2+


17

21

Relay Output

S1
R12
Digital Input

22
18

Analog Output

Intermediate Relay
22

External Resistor R
R21 R22

23
19

AC / DC
S2
23

24
20

24

External Resistor R

Analog Output (External Power Supply < 250Vac


Digital Input
4~20mA, R<500Ω or 30Vdc I<3A)

Hoyt Electrical Instrument Works, Inc. Phone: (800) 258-3652 www.hoytmeter.com


23 Meter Street Fax: (603) 753-9592 Page 2 (4)
Penacook, NH 03303 Email: sales@hoytmeter.com
AcuDC 240 Series
Multifunction Power & Energy Meter

AcuDC 240 Series DIN Rail Mounting Adapter


AcuDC 240 Series DIN Rails adapter provide easy installation of panel-mount AcuDC 240 series meter on

Dimensions
unit: mm (inch)
4.0(0.157) 7.5 (0.295)
6.8(0.268)

6(0.236)
6.8(0.268)

7.8 7.8
(0.275) (0.275)

6.8(0.268) 6.8(0.268)

7.8(0.275)
FRONT SIDE BACK

Hoyt Electrical Instrument Works, Inc. Phone: (800) 258-3652 www.hoytmeter.com


23 Meter Street Fax: (603) 753-9592 Page 3 (4)
Penacook, NH 03303 Email: sales@hoytmeter.com
AcuDC 240 Series
Multifunction Power & Energy Meter

Technical Specifications Output


Parameter Accuracy Resolution Range Relay Output (RO)
Voltage 0.2% 0.001V 0~1200V Type Mechanical contact, Form A
Max Load Voltage 250Vac/30Vdc
Current 0.2% 0.001A 0~±50000A
Max Load Current 3A
Power* 0.5% 0.001kW 0~±60000kW
On Resistance 100mΩ (Max)
Energy* 0.5% 0.01kWh 0~9999999.99kWh Isolation Voltage 4000Vac
Drifh with Temperature <100ppm/˚C Mechanical Life 5 × 106 times
Stability 0.5‰/year Digital Output (Photo-Mos)
* 0.2% accuracy on Power and Energy available upon request Load Voltage Range 0~250Vac/dc
Load Current 100mA(Max)
Voltage
Max Output Frequency 25Hz, 50% duty cycle
Input Range Isolation Voltage 2500Vac
Voltage
2MΩ
Analog Output (AO)
Input Impedence Range 4-20mA/0~20mA; 0~5V/1-5V
Load <0.6W Accuracy 0.5%
Accuracy 0.2% Load Capacity Current type, max load resistance: 750 Ohm
Current Voltage type, max load current: 20 mA
Input Range 0~±10A(Direct Input, pick up current 0.01A) Power Supply
Input (P1)100-240Vac, 50/60Hz, 100-300Vdc
programmable range) (P2) 20-60Vdc
Shunt 50~100mV(programmable) Consumption 3W (typical value)
0~±5V/0-±4V, 4~20mA/12mA±8mA Environment
Power Consumption 2W(Max)
Operation Temperature -25°C ~ +70°C
Accuracy 0.2%
Storage Temperature -40°C ~ +85°C
Digital Input Humidity 5%~95%Non-condensing
Type Dry Contact Standard Compliance
Isolation Voltage 2500Vac
Safety Standard IEC 61010-1
Ordering Information EMC Standard IEC 55011,IEC 61000-6-2,IEC 61000-3-2
IEC 61000-3-3
AcuDC 240
Datalogging ND: No Datalogging Communication
D: Datalogging Type RS485, half duplex, Optical Isolated
(AcuRC 243 Only) Protocol Modbus-RTU
Baud rate 1200~38400bps
Communication NC: No Communication
Isolation Voltage 2500Vac
C: RS485, Modbus RTU
X0: No I/O
X1: 2DI+2AO (4~20mA/0~20mA)
I/O Option X2: 2DI+2AO (0~5V/1~5V)
VOLTAGE HALL EFFECT SENSOR ORDERING
X3: 2DI+2RO INFORMATION (0~5V output)
X4: 2DI+2DO 0.2% accuracy for Power and Energy
X5: 2DI+ ±15Vdc Special Order
Power Supply Please contact your local Accuenergy representative
Option P1:100-240Vac 50/60Hz, 100-300Vdc for further details
P2: 20-60Vdc CURRENT HALL EFFECT SENSOR ORDERING
A0: 0~±10A INFORMATION (4~20 mA output)
Current Option A1: Shunt (50~100mV) Special order
Please contact your local Accuenergy
Representative for further details
Note:
1000V: Nominal Input Voltage 1000Vdc When the input voltage is above 1000V, or the system
Voltage Option
600V: Nominal Input Voltage 600Vdc design requires an isolation sensor, the voltage input can
300V: Nominal Input Voltage 300Vdc be selected as Via Hall Effect Sensor (0-5V).
60V: Nominal Input Voltage 60Vdc The Voltage Hall Effect Sensor output range requires 0-5V.

Model AcuDC 241:Voltage Meter ORDERING INFORMATIOM


AcuDC 242:Current Meter
AcuDC 243:Multifunction Example: AcuDC 243 - 300 - A2 - P1 - X1 - C - D
Model DC DIN

Hoyt Electrical Instrument Works, Inc. Phone: (800) 258-3652 www.hoytmeter.com


23 Meter Street Fax: (603) 753-9592 Page 4 (4)
Penacook, NH 03303 Email: sales@hoytmeter.com