Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

LOCAL SELF GOVERNMENT

GOVERNMENT OF KERALA
BUILDING DETAILS - KMBR/ KPBR SCRUTINY REPORT

APPLICATION TYPE General Building UPLOADED DATE 14/04/2024

UPLOADED FILE tsc9.dxf UPLOADED TIME 19:04

STATUS : NOT ACCEPTED

1) GENERAL DETAILS
SURVEY / RESURVEY NUMBER: 42,29,45

REVENUE WARD: 5
VILLAGE: YAKKARA

DESAM: YAKKARA
PLOT AREA (IN Sq M): 2330.0

ACCESS WITH (IN METERS): 5.0


NUMNBER OF MECHANICAL PARKING: 0
EXISTING AREA TO BE DEMOLISHED (IN Sq M): 0.0
ALTERED AREA (IN Sq M): 0.0

COMPOUND WALL LENGTH (IN METERS): 0.0

1. The Plot area in the Site Plan exceeds the Plot area as per document.
2. Please define the Line in layer: BLK_3_AVG_GROUND_LVL not defined in the plan.
3. Please define the Line in layer: BLK_3_ROOF_LVL not defined in the plan.
ERRORS 4. Block 3 building height not defined in the plan.
5. Block 3 building occupany not defined in the plan.
6. Height of floor in layer BLK_2_FLR_0_STAIR_1 not defined in the plan.

2) OVERALL AREA SUMMARY

2-1) PROPOSED AREA

BLOCKS BUILT UP AREA (Sq M) FLOOR AREA (Sq M)

1 2397.7769 1437.5671
2 478.0377 478.0377

2-2) COVERED AREA


BLOCKS COVERED AREA (Sq M)
1 539.2643
2 387.8606

TOTAL AREA

BUILT UP AREA(Sq M) FLOOR AREA (Sq M) COVERED AREA (Sq M)

2875.8146 1915.6048 1087.3070

3) BLOCKWISE VALIDATIONS
BLOCK 1

HEIGHT OF BUILDING IN METERS 14.40


CATEGORY OF CONSTRUCTION New Construction
PROPOSED AREA AND OCCUPANCY
AREA PROVIDED FOR
BUILT UP AREA (Sq PARKING INSIDE THE
FLOOR FLOOR DESCRIPTION OCCUPANCY FLOOR AREA (Sq M)
M) BUILDING IN SQ M

A2 - Spl. Residential-
A2 - Spl. Residential 97.12, D - Assembly-
-1 BASEMENT-01 653.2013 19.6624
129.49

A2 - Spl. Residential
0 Ground 539.1513 525.0750 -

A2 - Spl. Residential
1 FIRST 598.2005 520.0930 -

A2 - Spl. Residential
2 SECOND 551.9953 317.5082 -

A2 - Spl. Residential
3 THIRD 55.2285 55.2285 -

Total 2397.7769 1437.5671 -

1.DA RAMP - DEFINED OR NOT

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


42(1) DA Ramp Defined in the plan. Accepted

2.DA RAMP - MAXIMUM SLOPE

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


Maximum Slope of DA Ramp 1
42(3) 0.08 0.08 Accepted

3.DA RAMP - SLOPE

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


42(3) Slope of DA Ramp Defined in the plan. Accepted

4.EXIT WIDTH- MAXIMUM OCCUPANT LOAD

RULE NO FLOOR REQUIRED PROVIDED STATUS


37(2) 37(3)
Table 16 & floor -1 164.0 525.0 Accepted
17
37(2) 37(3)
Table 16 & floor 0 135.0 225.0 Accepted
17
37(2) 37(3)
Table 16 & floor 1 150.0 313.0 Accepted
17
37(2) 37(3)
Table 16 & floor 2 138.0 313.0 Accepted
17
37(2) 37(3)
Table 16 & floor 3 14.0 313.0 Accepted
17

5.EXIT WIDTH- MINIMUM EXIT WIDTH

RULE NO FLOOR OCCUPANCY REQUIRED PROVIDED STATUS


37(2) Table A2 - Spl. Residential
floor -1 1.2(MTR) 3.50(MTR) Accepted
16
37(2) Table A2 - Spl. Residential
floor 0 1.2(MTR) 1.50(MTR) Accepted
16
RULE NO FLOOR OCCUPANCY REQUIRED PROVIDED STATUS
37(2) Table A2 - Spl. Residential
floor 1 1.2(MTR) 1.27(MTR) Accepted
16
37(2) Table A2 - Spl. Residential
floor 2 1.2(MTR) 1.27(MTR) Accepted
16
37(2) Table A2 - Spl. Residential
floor 3 1.2(MTR) 1.27(MTR) Accepted
16

6.FIRE STAIR - ABUTING

RULE NO REQUIRED PROVIDED STATUS


35(2)(1) should abut built up area is abutting built up area Accepted

7.FIRE STAIR - DEFINED OR NOT

RULE NO REQUIRED PROVIDED STATUS


35(2)(1) Defined in the plan. Accepted
The height of stair handrails shall not be less than
35(2)(5) 1.0 m and greater than 1.20 m Verify

8.FIRE STAIR - LANDING MINIMUM SIDE

RULE NO REQUIRED PROVIDED STATUS


35(2)(2) 1 1 landings are having minimum width Accepted
35(2)(2) 1 3 landings are having minimum width Accepted
35(2)(2) 1 1 landings are having minimum width Accepted

9.FIRE STAIR - MAXIMUM ALLOWED RISERS PER FLIGHT

RULE NO REQUIRED PROVIDED STATUS


35(2)(4) Less than or equal to 16 Flight-1 having the 11 risers Accepted
35(2)(4) Less than or equal to 16 Flight-2 having the 11 risers Accepted
35(2)(4) Less than or equal to 16 Flight-1 having the 11 risers Accepted
35(2)(4) Less than or equal to 16 Flight-2 having the 11 risers Accepted
35(2)(4) Less than or equal to 16 Flight-1 having the 11 risers Accepted
35(2)(4) Less than or equal to 16 Flight-2 having the 11 risers Accepted
35(2)(4) Less than or equal to 16 Flight-1 having the 11 risers Accepted
35(2)(4) Less than or equal to 16 Flight-2 having the 11 risers Accepted

10.FIRE STAIR - MAXIMUM HEIGHT OF RISER

RULE NO FLOOR DESCRIPTION REQUIRED PROVIDED STATUS


Maximum Height of Riser
35(2)(4) floor -1 0.19 0.13 Accepted

Maximum Height of Riser


35(2)(4) floor 0 0.19 0.14 Accepted

Maximum Height of Riser


35(2)(4) floor 1 0.19 0.15 Accepted

Maximum Height of Riser


35(2)(4) floor 2 0.19 0.14 Accepted

11.FIRE STAIR - TREAD

RULE NO FLOOR DESCRIPTION REQUIRED PROVIDED STATUS


11 steps in the flight-1 are
Minimum tread for fire
35(2)(3) floor -1 0.25 having the minimum tread Accepted
stair 1

11 steps in the flight-2 are


Minimum tread for fire
35(2)(3) floor -1 0.25 having the minimum tread Accepted
stair 1

11 steps in the flight-1 are


Minimum tread for fire
35(2)(3) floor 0 0.25 having the minimum tread Accepted
stair 1
RULE NO FLOOR DESCRIPTION REQUIRED PROVIDED STATUS
11 steps in the flight-2 are
Minimum tread for fire
35(2)(3) floor 0 0.25 having the minimum tread Accepted
stair 1

11 steps in the flight-1 are


Minimum tread for fire
35(2)(3) floor 1 0.25 having the minimum tread Accepted
stair 1

11 steps in the flight-2 are


Minimum tread for fire
35(2)(3) floor 1 0.25 having the minimum tread Accepted
stair 1

11 steps in the flight-1 are


Minimum tread for fire
35(2)(3) floor 2 0.25 having the minimum tread Accepted
stair 1

11 steps in the flight-2 are


Minimum tread for fire
35(2)(3) floor 2 0.25 having the minimum tread Accepted
stair 1

12.FIRE STAIR - WIDTH

RULE NO FLOOR DESCRIPTION REQUIRED PROVIDED STATUS


11 steps in the flight-1 are
Minimum width for fire
35(2)(3) floor -1 1 having the minimum Accepted
stair 1
width
11 steps in the flight-2 are
Minimum width for fire
35(2)(3) floor -1 1 having the minimum Accepted
stair 1
width
11 steps in the flight-1 are
Minimum width for fire
35(2)(3) floor 0 1 having the minimum Accepted
stair 1
width
11 steps in the flight-2 are
Minimum width for fire
35(2)(3) floor 0 1 having the minimum Accepted
stair 1
width
11 steps in the flight-1 are
Minimum width for fire
35(2)(3) floor 1 1 having the minimum Accepted
stair 1
width
11 steps in the flight-2 are
Minimum width for fire
35(2)(3) floor 1 1 having the minimum Accepted
stair 1
width
11 steps in the flight-1 are
Minimum width for fire
35(2)(3) floor 2 1 having the minimum Accepted
stair 1
width
11 steps in the flight-2 are
Minimum width for fire
35(2)(3) floor 2 1 having the minimum Accepted
stair 1
width

13.FRONT YARD

RULE NO LEVEL OCCUPANCY DESCRIPTION REQUIRED PROVIDED STATUS


(Minimum distance,
26(4)Table- A2 - Spl. Residential
0 Mean distance) (4.00, 4.00) (20.57, 23.55) Accepted
4

14.GENERAL STAIR - DEFINED OR NOT

RULE NO REQUIRED PROVIDED STATUS


39(1)(5) Defined in the plan. Accepted
The height of stair handrails shall not be less than 90
35(1)(3d) Verify
cm

15.GENERAL STAIR - MAXIMUM HEIGHT OF RISER

RULE NO FLOOR DESCRIPTION REQUIRED PROVIDED STATUS


Maximum Height of Riser Not Accepted
35(1)(3c) floor 0 0.15 0.16

Maximum Height of Riser


35(1)(3c) floor 1 0.15 0.15 Accepted

Maximum Height of Riser


35(1)(3c) floor 2 0.15 0.15 Accepted
16.GENERAL STAIR - TREAD

RULE NO FLOOR DESCRIPTION REQUIRED PROVIDED STATUS


10 steps in the flight-0 are
Minimum tread for
35(1)(3b) floor 0 0.3 M having the minimum tread Accepted
general stair 1

11 steps in the flight-2 are


Minimum tread for
35(1)(3b) floor 0 0.3 M having the minimum tread Accepted
general stair 1

11 steps in the flight-0 are


Minimum tread for
35(1)(3b) floor 1 0.3 M having the minimum tread Accepted
general stair 1

11 steps in the flight-2 are


Minimum tread for
35(1)(3b) floor 1 0.3 M having the minimum tread Accepted
general stair 1

11 steps in the flight-0 are


Minimum tread for
35(1)(3b) floor 2 0.3 M having the minimum tread Accepted
general stair 1

11 steps in the flight-2 are


Minimum tread for
35(1)(3b) floor 2 0.3 M having the minimum tread Accepted
general stair 1

17.GENERAL STAIR - WIDTH

RULE NO FLOOR DESCRIPTION REQUIRED PROVIDED STATUS


10 steps in the flight-0 are
Minimum width for
35(1)(3a) floor 0 1.2 M having the minimum Accepted
general stair 1
width
11 steps in the flight-2 are
Minimum width for
35(1)(3a) floor 0 1.2 M having the minimum Accepted
general stair 1
width
11 steps in the flight-0 are
Minimum width for
35(1)(3a) floor 1 1.2 M having the minimum Accepted
general stair 1
width
11 steps in the flight-2 are
Minimum width for
35(1)(3a) floor 1 1.2 M having the minimum Accepted
general stair 1
width
11 steps in the flight-0 are
Minimum width for
35(1)(3a) floor 2 1.2 M having the minimum Accepted
general stair 1
width
11 steps in the flight-2 are
Minimum width for
35(1)(3a) floor 2 1.2 M having the minimum Accepted
general stair 1
width

18.IN-BUILDING SOLUTIONS

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


41A In-Building Solutions Mandatory Defined in the plan. Accepted

19.LIFT - MINIMUM REQUIRED

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS REMARKS


Occupancies other than
Medical are provided,so
number of floors above
48, 40A(3) Minimum number of lifts
1 1 Accepted ground level > 4 is
required to have lifts

20.RAMP/LIFT DEFINED ON EACH FLOOR

MINIMUM NUMBER OF LIFTS


RULE NO FLOOR REQUIRED PROVIDED STATUS REMARKS
RULE NO FLOOR REQUIRED PROVIDED STATUS REMARKS
Lift required as ramp with
maximum slope of 0.1 not
48(3),
floor -1 1 1 Accepted defined on this floor
40A(3)

Lift required as ramp with


maximum slope of 0.1 not
48(3),
floor 0 1 1 Accepted defined on this floor
40A(3)

Lift required as ramp with


maximum slope of 0.1 not
48(3),
floor 1 1 1 Accepted defined on this floor
40A(3)

Lift required as ramp with


maximum slope of 0.1 not
48(3),
floor 2 1 1 Accepted defined on this floor
40A(3)

Lift required as ramp with


maximum slope of 0.1 not
48(3),
floor 3 1 1 Accepted defined on this floor
40A(3)

21.REAR YARD

RULE NO LEVEL OCCUPANCY DESCRIPTION REQUIRED PROVIDED STATUS


(Minimum
26(4)Table- A2 - Spl. Residential Not Accepted
0 distance,Mean (2.50,2.50) (1.44,3.07)
4
distance)

22.SANITATION

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


Special Water Closet - Minimum
one at Ground Floor + Minimum 1
Not Accepted
42 at every floors in multiples of 3, 2 1
(GF, 3rd, 6th etc)

Special Water Closet - Minimum


42 2.625 M2 1 having area 2.625 M2 Accepted
Area
Special Water Closet - Minimum
42 1.5 M 1 having dimension 1.5M Accepted
Dimension
Water Closet- Minimum Dimension
34(1)(1) 1.0 M 11 having 1.0 M Accepted

Water Closet- Minimum Area


34(1)(1) 1.1 M2 11 having 1.1 M2 Accepted

Male Water Closet 10


Female Water Closet 2
34(3)(1) Common Water Closet 1
Male Water Closet 26.0
Table 13, Special Water Closet 1.0 Not Accepted
Water Closet - Count Female Water Closet 17.0
14 And Rule (Special water closet adjusted with
Total Water Closet 43.0
42 1.0 Male Water closets)
Total Water Closet 14.0

34(1)(1) Urinal- Minimum Dimension 0.6 M 10 having 0.6 M Accepted


34(1)(1) Urinal- Minimum Area 0.42 M2 10 having 0.42 M2 Accepted
34(3)(1)
Table 13, Male Urinals 11.0 Male Urinals 10 Not Accepted
Urinal - Count
14 And Rule
42
34(3)(1)
Male Wash Basin 26.0
Table 13, Not Accepted
Wash Basin - Count Female Wash Basin 13.0 Total Wash Basin 4
14 And Rule
Total Wash Basin 39.0
42
RULE NO DESCRIPTION REQUIRED PROVIDED STATUS
34(3)(1)
Male Bath 26.0
Table 13, Not Accepted
Bath Room - Count Female Bath 13.0 Total Bath 0
14 And Rule
Total Bath 39.0
42

23.SIDE YARD

RULE NO LEVEL OCCUPANCY SIDE NUMBER DESCRIPTION REQUIRED PROVIDED STATUS


(Minimum
26(4)Table- A2 - Spl. distance,Mean (1.87, 13.52) Not Accepted
0 Side Yard1 (2.00, 2.00)
4 Residential distance)

(Minimum
26(4)Table- A2 - Spl. distance,Mean Not Accepted
0 Side Yard2 (2.00, 2.00) (1.76, 2.16)
4 Residential distance)

BLOCK 2

HEIGHT OF BUILDING IN METERS 10.00


CATEGORY OF CONSTRUCTION New Construction
PROPOSED AREA AND OCCUPANCY
AREA PROVIDED FOR
BUILT UP AREA (Sq PARKING INSIDE THE
FLOOR FLOOR DESCRIPTION OCCUPANCY FLOOR AREA (Sq M)
M) BUILDING IN SQ M

0 Ground D - Assembly 387.8606 387.8606 -


1 FIRST D - Assembly 90.1771 90.1771 -
Total 478.0377 478.0377 -

1.DA RAMP - DEFINED OR NOT

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


42(1) DA Ramp Defined in the plan. Accepted

2.DA RAMP - MAXIMUM SLOPE

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


Maximum Slope of DA Ramp 1
42(3) 0.08 0.08 Accepted

3.DA RAMP - SLOPE

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


42(3) Slope of DA Ramp Defined in the plan. Accepted

4.EXIT WIDTH- MAXIMUM OCCUPANT LOAD

RULE NO FLOOR REQUIRED PROVIDED STATUS


37(2) 37(3)
Table 16 & floor 0 259.0 270.0 Accepted
17
37(2) 37(3)
Table 16 & floor 1 21.0 150.0 Accepted
17

5.EXIT WIDTH- MINIMUM EXIT WIDTH

RULE NO FLOOR OCCUPANCY REQUIRED PROVIDED STATUS


37(2) Table
floor 0 D - Assembly 1.2(MTR) 1.50(MTR) Accepted
16
37(2) Table
floor 1 F - Commercial 1.2(MTR) 1.20(MTR) Accepted
16

6.FRONT YARD
RULE NO LEVEL OCCUPANCY DESCRIPTION REQUIRED PROVIDED STATUS
26(4)Table- (Minimum distance,
4 AND 4A 0 D - Assembly Mean distance) (4.5, 6) (5.44, 6.71) Accepted

7.GENERAL STAIR - DEFINED OR NOT

RULE NO REQUIRED PROVIDED STATUS


39(1)(5) Defined in the plan. Accepted

8.GENERAL STAIR - TREAD

RULE NO FLOOR DESCRIPTION REQUIRED PROVIDED STATUS


18 steps in the flight-0 are
Minimum tread for
35(1)(3b) floor 0 0.3 M having the minimum tread Accepted
general stair 1

9.GENERAL STAIR - WIDTH

RULE NO FLOOR DESCRIPTION REQUIRED PROVIDED STATUS


18 steps in the flight-0 are
Minimum width for
35(1)(3a) floor 0 1.2 M having the minimum Accepted
general stair 1
width

10.IN-BUILDING SOLUTIONS

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


41A In-Building Solutions Mandatory Defined in the plan. Accepted

11.REAR YARD

RULE NO LEVEL OCCUPANCY DESCRIPTION REQUIRED PROVIDED STATUS


26(4)Table- (Minimum
4 AND 4A 0 D - Assembly distance,Mean (1.5,2) (1.50,2.52) Accepted
distance)

12.SANITATION

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


Special Water Closet - Minimum
one at Ground Floor + Minimum 1
42 at every floors in multiples of 3, 1 1 Accepted
(GF, 3rd, 6th etc)

Special Water Closet - Minimum


42 2.625 M2 1 having area 2.625 M2 Accepted
Area
Special Water Closet - Minimum
42 1.5 M 1 having dimension 1.5M Accepted
Dimension
Water Closet- Minimum Dimension
34(1)(1) 1.0 M 1 having 1.0 M Accepted

Water Closet- Minimum Area


34(1)(1) 1.1 M2 1 having 1.1 M2 Accepted

34(3)(1)
Male Water Closet 1
Table 13,
Female Water Closet 1.0 Female Water Closet 2
14 ,34(3)(3), Water Closet - Count Accepted
Total Water Closet 1.0 Special Water Closet 1.0
Rule 42
Total Water Closet 4.0

34(1)(1) Urinal- Minimum Dimension 0.6 M 6 having 0.6 M Accepted


34(1)(1) Urinal- Minimum Area 0.42 M2 6 having 0.42 M2 Accepted
34(3)(1)
Table 13,
Male Urinals 6.0 Male Urinals 6
14 ,34(3)(3), Urinal - Count Accepted
Rule 42

34(3)(1)
Table 13, Male Wash Basin 1.0
14 ,34(3)(3), Wash Basin - Count Female Wash Basin 1.0 Total Wash Basin 2 Accepted
Rule 42 Total Wash Basin 2.0
13.SIDE YARD

RULE NO LEVEL OCCUPANCY SIDE NUMBER DESCRIPTION REQUIRED PROVIDED STATUS


(Minimum
26(4)Table-
distance,Mean (29.61, 29.63)
4 & 4A 0 D - Assembly Side Yard1 (1.5, 2) Accepted
distance)

(Minimum
26(4)Table-
distance,Mean
4 & 4A 0 D - Assembly Side Yard2 (1.5, 2) (1.65, 2.86) Accepted
distance)

BLOCK 3

HEIGHT OF BUILDING IN METERS 0


CATEGORY OF CONSTRUCTION

4) PLOT LEVEL VALIDATIONS

1.ACCESS WIDTH

OCCUPANCY/CON
RULE NO DESCRIPTION REQUIRED PROVIDED STATUS REMARKS
DITION
A2 - Spl. Residential
28(1), Table Minimum access
, D - Assembly 5(MTR) 5.0(MTR) Accepted
8 width

3.BIOGAS

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


1 In-situ Waste management
system as stipulated by Pollution
79(3) Minimum area of biogas 0.5(MTRSQ) Control Board is having minimum Accepted
area 0.5 m2

4.COVERAGE IN PERCENTAGE

RULE NO DESCRIPTION OCCUPANCY PERMISSIBLE PROVIDED STATUS


Should be less than Coverage in Floor -1 Should be less than
27(1) 1005.00 Accepted
2330.00 2330.00
Should be less than Should be less than
27(1) Coverage in Floor 0 1799.00 Accepted
2330.00 2330.00
Should be less than Should be less than
27(1) Coverage in Floor 1 1145.00 Accepted
2330.00 2330.00
Should be less than Should be less than
27(1) Coverage in Floor 2 849.00 Accepted
2330.00 2330.00
Should be less than Should be less than
27(1) Coverage in Floor 3 85.00 Accepted
2330.00 2330.00

5.DISTANCE BETWEEN BLOCKS

RULE NO DESCRIPTION OCCUPANCY REQUIRED PROVIDED STATUS


Minimum distance
26-(5) between blocks 2 and 1 3(MTR) 3.00(MTR) Accepted

6.DISTANCE TO ROAD

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


Un-Notified road, Distance from
23(2) building to street boundary Mininum 2 mtrs. 25.42 mtrs. Accepted

7.FSI

RULE NO DESCRIPTION OCCUPANCY REQUIRED PROVIDED STATUS


RULE NO DESCRIPTION OCCUPANCY REQUIRED PROVIDED STATUS
Should be less than 3.63, Should be less than 3.63
with additional fee of @ A2 - Spl. Residential,D - with additional fee of @
27 Rs.5000 x (FAR- Assembly Rs.5000 x (0.82- 0.82 Accepted
2.25)*PlotArea 2.25)*2330.0

8.HEIGHT OF BUILDING

RULE NO DESCRIPTION UP TO PROVIDED STATUS


Height of Building for Block 1
24(1A) Upto 65.14 mtrs. 14.40 mtrs. Verify

Height of Building for Block 2


24(1A) Upto 10.96 mtrs. 10.00 mtrs. Verify

9.PARKING

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


3.60 M x 5.50 M Minimum Area of No violation of area in 2 parking
42(5) DA Parking Slot Area Accepted
Each DA parking
42(5) DA parking 2 Numbers 2 Numbers Accepted
Distance between DA parking area
42(5) and main entrance Less than 30(MTR) 2.09(MTR) Accepted

2.70 M x 5.50 M Minimum Area of No violation of area in 36 parking


29(1) Parking Slots Area Accepted
Each Car parking
29(3) Table Not Accepted
Car Parking 42 Numbers 38 Numbers
10
29(5) Two Wheeler Parking Area 155.925 m2 164.63 m2 Accepted
29(12) Charging Point Should be defined Defined in the plan. Accepted

10.RAIN WATER HARVESTING

RULE NO DESCRIPTION OCCUPANCY REQUIRED PROVIDED STATUS


Workable RainWater Defined in the plan.
76(2) Accepted
Storage Arrangement
Minimum capacity of Rain
Not Accepted
76(2) Water Harvesting Tank D - Assembly 46356.25 L 36500.0 L

Ground water recharging Defined in the plan.


76(1) Accepted
system

11.SECURITY ZONE

RULE NO DESCRIPTION DECLARED STATUS


24(3) Building in Security Zone No Verify

12.SEPTIC TANK

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


79(2) Septic tank Defined in the plan. Accepted
Minimum distance from Proposed
septic tank to nearest point on the
79(4) 1.2 1.32 Accepted
plot boundary

13.SOLAR

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


Solar assisted water heating
Not Accepted
77, 78 system and Solar Energy 543.65 87.6316
installations
Solar assisted water heating
77, 78 system and Solar Energy Defined in the plan. Accepted
installations
RULE NO REQUIRED PROVIDED STATUS
36(2) 30(MTR) 18.73(MTR) Accepted
Not Accepted
36(2) 30(MTR) 30.80(MTR)

36(2) 30(MTR) 15.38(MTR) Accepted


36(2) 30(MTR) 4.21(MTR) Accepted

15.WASTE DISPOSAL

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


Provisions for segregation of
79(1) Defined in the plan. Accepted
waste
Minimum distance from waste
treatment facility like: leach
79(4) pit,soak pit etc to nearest point on 1.2(MTR) 2.46(MTR) Accepted
the plot boundary

16.WASTE WATER RECYCLE PLANT

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


Recycling and reuse of waste
Not Accepted
79(6) water generated facility Not defined in the plan.

17.WELL

RULE NO DESCRIPTION REQUIRED PROVIDED STATUS


75(2(iv)) Number of Existing Wells 1 Verify
Minimum distance from Existing
Well to nearest point on Proposed
75(2(iv)) Leach Pit, Soak Pit, Refuse Pit, 7.5(MTR) 26.93(MTR) Accepted
Earth Closet

Minimum distance from Existing


Well to nearest point on Proposed
75(2(iv)) 7.5(MTR) 31.35(MTR) Accepted
Septic Tank

5) DECLARATIONS BY THE APPLICANT (S)

SL.NO DECLARATION PROVIDED VALUE


Is there any opening on the sides of the buildings, at a height above 2.10 m, where the open space
1 NA
available is less than or equal to 60 cm?
Is there any opening on sides of the buildings, at a height below 2.10 m, where the open space
2 NA
available is less than or equal to 60 cm?
Is there any opening on rear side of the buildings, at a height above 2.10 m, where the open space
3 NA
available is less than 1.0 m?
Is there any opening on rear side of the buildings, at a height below 2.10 m, where the open space
4 NA
available is less than 1.0 m?
Whether NOC from the adjascent plot owner to abut the side of the buildings available?
5 NA

Whether NOC from the adjascent plot owner to abut the rear of the buildings available?
6 NA

7 Whether the building belongs to the category of Govt. Or Aided School? NA


Whether the building situated in a plot included in an authorised Commercial Zone?
8 YES

Is there any opening on side 01 of the commercial building situated in the Commercial Zone?
9 NA

Is there any opening on side 02 of the building situated in the Commercial Zone?
10 NA

You might also like