f0 Alm 945

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

B–61395E/06 Fanuc Alpha Spindle Alarm 945, 946

ALARMS 945 AND 946 (SERIAL SPINDLE COMMUNICATION ERRORS)


Cause and corrective action
945: A communication error occurred in the first serial spindle.
946: A communication error occurred in the second serial spindle.

A poor connection between a memory printed–circuit board and the serial spindle amplifier
may occur at the points shown below.
Fanuc 0

● The memory printed–circuit board is defective.


○ The cable between the memory printed–circuit board and optical I/O
link adapter has a broken wire or is unhooked.
● The optical I/O link adapter is defective.
○ The fiber optics cable has a broken wire or is unhooked.
The serial spindle amplifier is defective.