Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Tank

Inventory and
Management
System

Proven performance •
Windows based •
Unique Communication Capabilities •
Open System / Interfaces •
OPC – Easy integration to other systems •
Full API conformity •
100% KROHNE support •
Tank Inventory and Management System

Powerful and intelligent


Proven performance · Windows based · Unique Communication Capabilities
Open System / Interfaces · OPC – Easy integration to other systems
Full API conformity · 100% KROHNE support

KROHNE Tank Inventory and Management System


(TIM) is a powerful and intelligent control system
designed for tank monitoring and control. It can be
employed as a single tank solution, or as part of a
comprehensive multi-tank farm including loading
and offloading.

The system consists of precision level meters (BM


70A Level Radar or its high-precision pendent, the
BM 70P and also the BM 100A TDR level meter or
the BM 100AP high-precision variant). Together with
all auxiliaries such as temperature and pressure
gauges, overfill switches, dry-run protection switches
and communications.

The heart of the system is the SCADA (Supervisory


Control and Data Acquisition) system that resides
on one or more industrial PC’s with SCADD and CM
(Floating Roof Calculation Module) Software. These
industrial PC’s function as the Human machine In-
terface (HMI) for one or more tank measurement
systems.
Main Screen
Overview of the main tank-
and transducer data from
each measurement system.

Tank Data Screen


Overview of the main tank-
and transducer data from
each tank measurement,
together with the corrections
used to calculate volume
and mass.

Tank Detail Screen


Detailed transducer data from
the tank and the stilling well.

Com View Screen


Communication status of the
tank measurement system
and the HMI SCADA system.
Alarm Screen
Alarms, warnings and mes-
sages that are active or have
been active on the tank
measurement system and
the HMI SCADA system.

Tank Config Screen


Tank parameters and the
tank and stilling well trans-
ducer positions and ranges.

Calc Config Screen


Methods used to calculate
volume and mass.

Override Screen
Manually entered values
which are used to override
the measured values for
level, temperature and pres-
sure.
KROHNE Oil and Gas
The year 2001: For over 10 years, KROHNE had been
supplying flowmeters and level gauges to the Oil
and Gas industry. Following the introduction and
successful application of high-precision level gauges
such as the BM 70P and the unique ultrasonic
5-beam custody-transfer flowmeter ALTOSONIC V, it
was clear that demand was so high that a dedica-
ted company was needed to handle this industry.
We relieved selected experts of all their duties so
that they could concentrate solely on Oil and Gas.

KROHNE Oil and Gas is now a 2-year old company


with a 10-year tradition. The staff grew as experts
from petrochemical companies, engineering compa-
nies, and instrument manufacturers were recruited,
all with decades of hands-on experience on oil rigs,
in oil field and in refineries.

Experts at your side


At our site in the Netherlands, close to Rotterdam,
we brought all these experts together in their own
buildings that house the following departments:

• Consultation and Planning


• Engineering
• Development
• Manufacturing
• Testing
• Software
• Pre-Installation
• Quality Control

While for the major oil-producing regions and coun-


tries we have local staff to look after the needs of
our customers on site.

In short, from start to finish you’ll find experts at


your side.
KROHNE Oil & Gas
Ask us to solve your problem
General Question List for Tanks/Tank Inventory and Management System (TIM)
Tank No.: TAG No.:

1. Dimension of the Tank 4. Measuring Instruments / Measuring Units


Height Description yes / no Accuracy
Diameter Level
Volume Interface
Please provide, if possible, Temperature
the drawing of the tank. - Multiple Sensors
- Spot Sensor
2. Type of Tank
Density
Floating Roof Tank
Pressure Bottom
Fixed Roof Tank
Pressure Top (vapour)
Dome Tank
Overfill Protection
Sphere Tank
Underground Tank
Horizontal Tank
5. Measuring Variables / Calculations
3. Product / Process Data Description yes / no
Product Name Actual Level
Density Mass Calculation
Viscosity Calculations for reference Conditions
Dielectric Constant - Mass
Pressure (vapour) - Volume
Temperature Product Density Calculation
Temperature Ambient Temperature
Pour Point Interface

6. To accomplish our final offer and technical 7. Remarks:


optimized offer, we kindly asked you to
provide further data as follows:

• Tank data
• Flange sizes
• Stilling wells (diameter / condition)
• Pressure class
• Drawing of the tank
• Drawings of the tank with all distances and
locations (control room / cabinet room /
safe areas / etc.)
• Specification of product / tank groups
(for reason of graphical representation)
• Strapping tables
• Dynamic behavior of the tank
(pressure / temperature specification)
Netherlands
• TAG Specification Paper KROHNE Oil & Gas B.V.
• P & ID Drawings Kerkeplaat 12
• Communication with higher Systems NL-3313 LC Dordrecht
• Fiscal Measurement Tel: +31(0)78-6306300
Fax: +31(0)78-6306404
• Certificates / Approvals E-mail:info@krohne-oilandgas.nl
• Special Designs / Extras

You might also like