INSTALLATION
Cabinet shall be fixed on a deck through the three Ø9 mm bolting holes
existing in the flange of each adjustable stainless steel feet.
If necessary feet can be welded on a deck.
Ensure the unit is level (use spirit level if needed). This ensures doors and
locks work properly. Uneven installation may twist the chassis.
Make sure the area below the cabinet is clear to allow free condenser
air circulation.
Should the unit still be cold when taken in, humidity will condensate
on its surface in wintertime. Do not plug on the unit until it has dried
and reached the room temperature.
Protect the cabinet from direct sunlight and other objects radiating heat,
such as owen, radiator etc.
The ambient temperature must not rise above +32°C or fall below +5°C.
Ensure the voltage and frequency band is fitted with the cabinet and
connect the unit to earthed socket protected with a 10 amp. fuse.
3
REV 062007B
START-UP
Let the cabinet stay on its final place for 2 hours before
starting-up. The time is needed for the machinery
lubrication oil to run into the oil compartment of
compressor.
USE
Marine cabinets are made for storage of chilled and
frozen food.
Keyboard
To display and modify target set point; in programming mode it selects a parameter or
confirm an operation. By holding it pressed for 3s when max or min temperature is
displayed it will be erased.
To see the max stored temperature; in programming mode it browses the parameter codes
or increases the displayed value.
To see the min stored temperature; in programming mode it browses the parameter codes
or decreases the displayed value.
Switch ON and OFF the light (cabinets equipped with fluorescent lamp)
4
REV 062007B
LED-lights
Temperature settings
The ”Lo” message will be displayed followed by the minimum temperature recorded.
By pressing the -key or waiting for 5s the normal display will be restored.
The ”Hi” message will be displayed followed by the maximum temperature recorded.
By pressing the -key or waiting for 5s the normal display will be restored.
To reset the stored temperature, when max or min temperature is displayed, press -key
until ”rST” label start blinking.
Push and immediately release the SET –key. The display will show the set point value.
To memorise the new set point value push the SET –key again or wait 10s.
5
REV 062007B
Alarm signals
”P2” Evaporator probe failure. The unit will work, but there is no temperature reading displayed.
Defrosting takes place as programmed. Call for service.
“A2” Maximum condenser temperature alarm. Clean the condenser (see page 6)
“E” Data or memory failure. To reset the ”EE” alarm and restart the normal functioning
press any key, the ”rST” message is displayed for about 3s.
Temperature alarms ”HA”, ”LA”, ”HA2” ja ”LA2” automatically stop as soon as the related
temperature returns to normal values or when the defrost starts.
Once the alarm signal is detected the buzzer can be silenced by pressing any key.
Turn the power OFF and unplug the unit from power.
Clean the cooling unit condenser air filter regularly i.e. twice
a month. Dusty filter leads to decreased capasity, continious
running of the compressor and the possible damage of
the cooling unit.
6
REV 062007B
MALFUNCTION
The unit does not reach the required temperature or does not chill at all
QUARANTEE
The quarantee is valid only when the unit is used solely for purposes, stated in this manual.
The quarantee expires if the unit is being used against installation, use and maintenance manual.
All units are supplied under our terms and conditions of sale, a copy of which may be obtained upon request.
The manufacturer or his selling agents is not at any time or any circumtances liable for direct
or indirect losses of resulting effects caused by an unfit of badly maintained unit.
The manufacturer reserves the right to make any changes or improvements without prior notice.
When claiming for warranty, the serial number of your cabinet is needed.