INSTALLATION, USE AND MAINTENANCE – MARINE CABINETS

UNITS: MR, MF, MRF 2/2


REV 062007B

CONTENCE

Installation, use and maintenance manual 3

Receiving the goods 3

Before use and installation 3

Installation 3

Start-up 4

Use 4

Use: Wing electronic thermostat 4

Keyboard 4

LED –lights 5

Temperature settings 5

Alarm signals 6

Cleaning by the user 6

Malfunction 7

Quarantee 7

PRODUCT INFORMATION – TUOTETIEDOT

Type of unit / Tyypi

Serial number / Valmistusnumero

Place and date of purchase / Ostopaikka ja -aika

2
REV 062007B

INSTALLATION, USE AND MAINTENANCE MANUAL


PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE.
KEEP THESE INSTRUCTIONS FOR FURTHER USE AND OTHER USERS.

FOLLOWING THESE INSTRUCTIONS CONTRIBUTES PROPER AND LONGTERM


FUNCTION OF THE UNIT FOR MAXIMUM EFFICIENCY AND MINIMUM SERVICE
AND REPAIR COSTS.

FOR QUARANTEE, SEE PAGE 7.

THESE INSTRUCTIONS APPLY TO UNITS MR, MF AND MRF 2/2

RECEIVING THE GOODS


Examine the unit before accepting the delivery.

In case of any damage, please note the waybill and report


to your forwarder and supplier immediately.

Quarantee does not cover damages due to transportation.

BEFORE USE AND INSTALLATION


Unpack the unit at site.

Remove the protection films on outer surfaces of the unit.

INSTALLATION
Cabinet shall be fixed on a deck through the three Ø9 mm bolting holes
existing in the flange of each adjustable stainless steel feet.
If necessary feet can be welded on a deck.

Feet can be adjusted after bolt-mounting.

Ensure the unit is level (use spirit level if needed). This ensures doors and
locks work properly. Uneven installation may twist the chassis.

Make sure the area below the cabinet is clear to allow free condenser
air circulation.

100 mm free space above the cabinet is necessary for ventilation


and service.

Should the unit still be cold when taken in, humidity will condensate
on its surface in wintertime. Do not plug on the unit until it has dried
and reached the room temperature.

Protect the cabinet from direct sunlight and other objects radiating heat,
such as owen, radiator etc.

The ambient temperature must not rise above +32°C or fall below +5°C.

Ensure the voltage and frequency band is fitted with the cabinet and
connect the unit to earthed socket protected with a 10 amp. fuse.

3
REV 062007B

START-UP

Let the cabinet stay on its final place for 2 hours before
starting-up. The time is needed for the machinery
lubrication oil to run into the oil compartment of
compressor.

Clean the unit thoroughly before start-up with mild


dish washing solution or other suitable detergent.
Do not use scouring powder.

Unpack the shelf package and set the shelves in place.

Do not add any products until the unit has reached


the required operation temperature.

USE
Marine cabinets are made for storage of chilled and
frozen food.

Operating temperature for chiller is + 2°C...+ 8°C and for


freezer - 18°C...- 25°C.

Food which contains vinegar, such as pickels, sallad dressing


and lingonberry jam, shall be stored in covered receptacles.
Vinegar may damage the evaporator.

Cabinet shall not be used outdoors or exposed to rain.

USE: WING ELECTRONIC THERMOSTAT

Keyboard

To display and modify target set point; in programming mode it selects a parameter or
confirm an operation. By holding it pressed for 3s when max or min temperature is
displayed it will be erased.

To see the max stored temperature; in programming mode it browses the parameter codes
or increases the displayed value.

To see the min stored temperature; in programming mode it browses the parameter codes
or decreases the displayed value.

By holding the button pressed for 3s the defrost is started.

Switch ON and OFF the light (cabinets equipped with fluorescent lamp)

Switch ON and OFF the counter

4
REV 062007B

USE: WING ELECTRONIC THERMOSTAT

LED-lights

ON; the compressor is running

FLASHING; programming phase (flashing with LED )

Anti-short cycle delay enabled

ON; the fan is running

FLASHING; programming phase (flashing with LED )

ON; the defrost is enabled

FLASHING; the fast freezing cycle is enabled

ON; ALARM –signal (for alarm codes see page 6)

ON; the light is on (cabinets equipped with fluorescent lamp)

Temperature settings

Press and release the -key

The ”Lo” message will be displayed followed by the minimum temperature recorded.

By pressing the -key or waiting for 5s the normal display will be restored.

Press and release the -key

The ”Hi” message will be displayed followed by the maximum temperature recorded.

By pressing the -key or waiting for 5s the normal display will be restored.

To reset the stored temperature, when max or min temperature is displayed, press -key
until ”rST” label start blinking.

How to modify the set point:

Push and immediately release the SET –key. The display will show the set point value.

The SET LED starts blinking.

To change the SET value push the or arrows within 10s.

To memorise the new set point value push the SET –key again or wait 10s.

5
REV 062007B

Alarm signals

”P1” Thermostat probe failure. Call for service.

”P2” Evaporator probe failure. The unit will work, but there is no temperature reading displayed.
Defrosting takes place as programmed. Call for service.

”P3” Condenser probe failure. Call for service.

”HA” Maximum temperature alarm.

”LA” Minimum temperature alarm

“A2” Maximum condenser temperature alarm. Clean the condenser (see page 6)

”LA2” Minimum condenser temperature alarm.

“E” Data or memory failure. To reset the ”EE” alarm and restart the normal functioning
press any key, the ”rST” message is displayed for about 3s.

Temperature alarms ”HA”, ”LA”, ”HA2” ja ”LA2” automatically stop as soon as the related
temperature returns to normal values or when the defrost starts.

Once the alarm signal is detected the buzzer can be silenced by pressing any key.

CLEANING BY THE USER

Turn the power OFF and unplug the unit from power.

Clean the cabinet with a moist cloth with detergent.


Never use running water to clean the cabinet.

Clean stainless steel surfaces with mild water


blended dishwashing solution or other suitable
detergent. Do not use scouring powder.

Clean the gasket with mild water blended dishwashing


solution or other suitable detergent. Do not use sharp Filter
instruments or solvent of any kind.

After cleaning, spray or wipe the gasket with silicone to make


it more pliable and dirt resistant.

Clean the cooling unit condenser air filter regularly i.e. twice
a month. Dusty filter leads to decreased capasity, continious
running of the compressor and the possible damage of
the cooling unit.

Remove the filter and rinse it with running water.

Shake off water and replace.

6
REV 062007B

MALFUNCTION

The unit does not start

Make sure the operation switch is on (page 4).

Check the plug connection.

Check the fuse.

The unit does not reach the required temperature or does not chill at all

Make sure the operation switch is on (page 4).

Check the plug connection.

Check the fuse.

Check the thermostat settings (page 5).

Check the filter (page 6).

For control unit malfunctioning codes see page 5

QUARANTEE

The quarantee is valid only when the unit is used solely for purposes, stated in this manual.

The quarantee expires if the unit is being used against installation, use and maintenance manual.

All units are supplied under our terms and conditions of sale, a copy of which may be obtained upon request.

The quarantee does not apply to

defects caused by faulty installation

defects due to ignoring maintenance and cleaning by the user

defects caused by natural wear

defects caused by improper use of the unit

settings, repairs or spare parts due to negligence, non-attention


or not following these installation, use and maintenance
instructions

The manufacturer or his selling agents is not at any time or any circumtances liable for direct
or indirect losses of resulting effects caused by an unfit of badly maintained unit.

The manufacturer reserves the right to make any changes or improvements without prior notice.

When claiming for warranty, the serial number of your cabinet is needed.

You might also like