Professional Documents
Culture Documents
DBxConnect User Guide
DBxConnect User Guide
User’s guide
Manufactured By
Vyaire Medical, Inc.
26125 North Riverwoods Blvd.
Mettawa, IL 60045 U.S.A.
1-833-327-3284
customersupport@vyaire.com
www.vyaire.com
Intended use
The DBx Connect software converts VmaxTM data to a format that it is compatible
with the Sentry Suite system. The software also enables the retrieval of patient
demographics data from the Sentry Suite system by the Vmax system.
DBx Connect is a series of applications and services that will import Vmax, nSpire,
Medical Graphics, and MicroMedical data into the SentrySuite database. Data import
can be performed manually or via schedule using the DBxConnect Data Import
Scheduler. Additionally, Vmax Encore systems can transfer data near real-time to the
SentrySuite.
For nSpire and Medical Graphics data import, Vyaire does not provide support for
the access, maintenance, or integrity of the source database or application. Vyaire
provides support only for the process of converting the source data into the
SentrySuite database.
The system comprises four main components:
● Import SentrySuite patient demographics in the Vmax Encore system
● Near real-time transfer of Vmax Encore patient and measurement data into
SentrySuite
● Manual batch transfer of Vmax, nSpire, Medical Graphics, and MicroMedical
patient and measurement data into SentrySuite
● Scheduled transfer of Vmax, nSpire, and Medical Graphics, and MicroMedical
patient and measurement data into SentrySuite
Note:
You cannot transfer SentrySuite measurement data to the Vmax, nSpire,
Medical Graphics, or MicroMedical system.
Product description
Product specifications
Table 1 Minimum computer requirements
Supported operating systems Microsoft Windows XP SP2 and
SP3
HIPAA compliance
The Vmax Encore system to Sentry Suite Connectivity program can access any Vmax
Encore database, encrypted or non-encrypted. Using the Security Administration
(VSA) program does not prevent this program from operating.
Therefore, it must be noted:
● Access rights to the Vmax database, Vmax software, and DBxConnect software
is the responsibility of the customer.
● Access rights to the nSpire database, nSpire software, and DBxConnect software
is the responsibility of the customer.
● Access rights to the Medical Graphics database, Medical Graphics software, and
DBxConnect software is the responsibility of the customer.
● Access rights to the Sentry Suite database and the Sentry Suite software is the
responsibility of the customer.
● At no point in the DBxConnect data integration program is patient measurement
data accessible or viewable.
● The mechanism (transfer file) used to import data to the Sentry Suite database
is encrypted and deleted after the data transfer is completed.
Note:
For communication with, and access to, a SentrySuite system, Encore version
21-2 or higher must be installed.
3. Click the Settings tab and select the desired Data Source.
4. Click Configure.
5. Enter the IP address and port number of the computer where the DBxConnect
database adapter was installed. Select Enable mixed network and select
the appropriate Anaerobic Threshold (AT) and Respiratory Compensation
Point (RCP). Click OK after entering the appropriate settings.
Note:
It is suggested to use the 1st threshold (Wasserman AT) for AT
determination and the 2nd threshold (Wasserman RCP) for RCP
determination as that is how Vmax automatically calculates these points.
The reason for alternative selections is due to different viewpoints on
calculating AT and RCP. Please take the time to consider the most
appropriate selections for your laboratory.
1. Select the patient file and click OK, or double-click the patient file to move
it into the Vmax program.
Note:
This dialog box only appears if more than one patient matches the filter
criteria. For example, if you enter “A1232” in the ID field, then the
patient ID 1232 will automatically be selected and the dialog box will not
appear.
Note:
If necessary, height and weight values are included in the demographic
data transferred from SentrySuite.
Wait for this message box to close before continuing with any Vmax actions.
3. Enter a name for the task (does not apply for Manual Job) in the Create a
Job window and then click Next.
Note:
If this is to be a reoccurring scheduled task on the same database,
it is recommended to perform an entire database import then
schedule the reoccurring task using the data since last import
selection.
9. If the selection was a Manual Job, the import task will begin. A dialog
box will appear to give a 30-second countdown to start of import. Click
OK to start immediately or click Cancel to stop the job.
10. If the selection was a New Job, the information will appear in the job list.
You can click Run Job to manually run the selected job. Also, you can edit,
delete, or copy a selected job. Click Schedule to set a schedule for a
selected job.
11. Select daily, weekly, or monthly. Click Next.
Note:
An actual password is required. If your login does not require a password
then the schedule task cannot be set.