Volvo Guided Diagnostics

Date: Information Type:


27-Feb-23 Diagnostics Fault Codes 249: V2ECU 1468: OBW Rubber Spring Right,
load cell
Profile:
A60H Volvo

MID249 PPID1468 / SE9302


Showing Selected Profile

Valid for serial numbers


Model Production site Serial number start Serial number stop
A60H Volvo

SAE code
MID/Control Unit MID249 V2ECU
PID/PPID/SID/PSID PPID1468 OBW Rubber Spring Right, load cell
Machine display message
Text presentation SE9302

Reference Load weighing, description

Fault mode diagnosis

Fault mode Detection conditions:The vehicle control unit 2 (V2-ECU) registers: that the voltage is
FMI 3 above 4.8 V (V2B18)
Symptom: Possible causes:

¡ Load weighing is not working ¡ Open circuit on frame ground cable


¡ Not possible to perform load ¡ Signal line short-circuited to 5 V or
calibration higher voltage
¡ Frame ground cable short-circuited
to voltage
¡ Defective sensor

Action Fault trace the circuit


SE9301/SE9302, description and measuring

Ref: Service Tip ART 371 18 ST - Mixed connector positions in wiring harness

Fault mode Detection conditions:The vehicle control unit 2 (V2-ECU) registers: that the voltage is
FMI 4 below 0.2 V (V2B18)
Symptom: Possible causes:

¡ Load weighing is not working ¡ Open circuit on signal line


¡ Not possible to perform load ¡ Open circuit on feed cable
calibration ¡ Signal line short-circuited to frame
ground
¡ Defective sensor

Action Fault trace the circuit


SE9301/SE9302, description and measuring

Ref: Service Tip ART 371 18 ST - Mixed connector positions in wiring harness

Guided Diagnostics