ELECTRIC SYSTEM ]
MC1-D11 Left swing stop prop. valve 100 mA to 700 mA 200 mAp-p 100 Hz
MC1-D12 Right swing stop prop. valve 100 mA to 700 mA 200 mAp-p 100 Hz
MC1-C30 Re. drum rotate detect grip (option) พ/ฝ +24V / OPEN
Mismatch between output command
MC1-C31 Safety relay operation Operation / Normal GND / OPEN
and actual port condition.
Energized /
MC1-C32 Engine stop relay operation GND / OPEN
De-energized
MC1-C33 Swing voice alarm ON / OFF GND / OPEN
MC1-C34 Re. / 3rd. drum change GND / OPEN
GND /
MC1-C35 Vacancy
OPEN (CPU error)
Mismatch between output command
MC1-C36 3rd. drum turn detection grip +24V / OPEN
and actual port condition.
2. 6SHFL¿FDWLRQVRIPDLQFRQWUROOHULQSXWRXWSXW