Inspection Report End Winding Assembly

Generator Maintenance Axial Distance Check


Work : Generator Rotor Recondition Type: T276-371
Plant/Unit: National Power Supply/NPS7 Euipment S/N: 5000156
Manufacturer: GEC Alstom
 Before Baking
 After Baking

Unit : mm

DE NDE
Code Axial distance Spec
Left Right Left Right
Pole 1 - 25.27 25.14 25.28 25.26
c0 Rotor plate packer thickness
Pole 2 - 25.43 25.31 25.15 24.33
Pole 1 - 85.14 85.70 92.42 92.77
c1 Field lead support thickness
Pole 2 - 85.45 86.15 89.96 90.27
Pole 1 - 150.00 154.00 159.00 160.00
y1 Axial distance rotor to coil 1
Pole 2 - 152.00 153.00 157.00 158.00
Pole 1 - 214.00 209.00 212.00 216.00
y2 Axial distance rotor to coil 2
Pole 2 - 207.00 207.00 211.00 213.00
Pole 1 - 260.00 264.00 268.00 270.00
y3 Axial distance rotor to coil 3
Pole 2 - 261.00 260.00 263.00 267.00
Pole 1 - 318.00 317.00 327.00 325.00
y4 Axial distance rotor to coil 4
Pole 2 - 316.00 317.00 325.00 324.00
Pole 1 - 376.00 377.00 382.00 380.00
y5 Axial distance rotor to coil 5
Pole 2 - 373.00 375.00 381.00 380.00
Pole 1 - 432.00 433.00 436.00 434.00
y6 Axial distance rotor to coil 6
Pole 2 - 428.00 430.00 435.00 433.00
Pole 1 - 492.00 491.00 492.00 489.00
y7 Axial distance rotor to coil 7
Pole 2 - 489.00 488.00 488.00 490.00
Comments :

Check By: Approved By: Inspected By:


( Miss Thitiphon amphaicharatkun ) (นายประเสริฐ มารยาท) วก.795 (Mr.Chawakorn Champakeed)
Date : 13/3/2024 Date : 13/3/2024 Date : 13/3/2024
JHM Controls and Engineering Co.,Ltd.
155/85 Ratchaburi Industrial Estate M.4 T.Chet-samian A.Photharam Ratchaburi 70120