Download as pdf or txt
Download as pdf or txt
You are on page 1of 48

Photometric Test Report

VERSAPAR
12 X 10W RGBW / FC LED
compact zoom PAR
TESTING PROCESS
Prolights has its own optical testing laboratory in arder to previde accurate photometric reports far its
lighting products. The testing laboratory contains certain variety of precise lighting measurement systems
that ensure an optimal reading of all the characteristic parameters of the lighting devices. AII
measurements are made at a controlled room temperature of 20° C without any external light sources.
This photometric report is obtained through the data measured by a high precision measurement system
and analyzed by a dedicate software.

Prolights measurement instrument


Prolights measurement instrument is a complete measurement system far any light source. lt's equipped
with two-axis goniometer, that enables to measure the full 3D distribution field of the light source. This
instrument measures the light intensity, the beam angle and the most significative colors parameters, like
color temperature, spectral distribution, CRI, CQS, TM-30 with a very high accuracy rate.
Please Note: AII measurements are made with light source at operating temperature. Befare starting the
measurement, the instrument analyzes the process of the light source during the heating phase. The
measuring process of all the parameters begins only when the light emission is stable, that is with a
variation of less than 0.5% in a 15 minutes time frame.

Prolights measurement software


The software provides user friendly interface far the operator who does the measurements, and it also
analyzes and processes all the collected data by the instrument. With this software it is possible to see the
measured data in real-time and it is possible to examine all the measured data and graphics afterwards as
well. AII infarmation is collected in a specific Prolights template, and the software creates also IES and
LDT files, which are widely used to transfer the photometric data, and to develop lighting system.

Additionally, the fixtures are rechecked using various hand-held instruments like Sekonic C-700 and
Gossen Mavospec Base, this is done to ensure, that the data in the photometric report are as accurate as
possible.

PROLIGHTS is a trademark of Via A. Olivetti snc prolights.it


MUSIC & LIGHTS S.r.l. 04026 - Minturno (LT) ITALY info@prolights.it
musiclights.it Tel: +39 0771 72190
Total lumen output:

1786 lm

Peak candela output:

6221 cd

PRODUCT NAME: 165 180 165


150 150
VERSAPAR
135 135

MEASURAMENT CONDITIONS: 120 120

Beam angle:
105 105
Max Zoom
90 90
Target:
Full On 75 75

60 60

Operator: 45 45
Paolo Carvone 30 30
15 0 15

Date and time:


25/05/2020 11:08:17 31,3°
Beam angle 50%: 31,3°
Field angle 10%: 48,9°
Cut off angle 2.5%: 61,4°

Spectra

400 450 500 550 600 650 700 750 800


BEAM DETAILS

Beam angle 50% Field angle 10% Cut off angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

31,3° 48,9° 61,4° 99,8% 99,5%

Distance (meter) 3m 5m 10 m 15 m 20 m
Distance (feet) 9,8 ft 16,4 ft 32,8 ft 49,2 ft 65,6 ft
16 lx
28 lx
62 lx
Lux* 249 lx
691 lx
31,3°
Beam center

64 fcd
Footcandles* 23 fcd

*measured at
6 fcd
center of beam 3 fcd
1 fcd
Beam width (meter) 1,7 m 2,8 m 5,6 m 8,4 m 11,2 m
Beam width (feet) 5,5 ft 9,2 ft 18,4 ft 27,6 ft 36,8 ft

BEAM INTENSITIES AND WIDTHS


Distance 1m 2m 3m 4m 5m 7,5m 10m 15m 20m 25m 30m 40m 50m

Distance 3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 24,6ft 32,8ft 49,2ft 65,6ft 82ft 98,4ft 131,2ft 164ft

Lux 6215lx 1554lx 691lx 388lx 249lx 110lx 62lx 28lx 16lx 10lx 7lx 4lx 2lx

Footcand. 577fcd 144fcd 64fcd 36fcd 23fcd 10fcd 6fcd 3fcd 1fcd 1fcd 1fcd 0fcd 0fcd

Beam wid. 0,6m 1,1m 1,7m 2,2m 2,8m 4,2m 5,6m 8,4m 11,2m 14m 16,8m 22,4m 28m

Beam wid. 1,9ft 3,7ft 5,5ft 7,3ft 9,2ft 13,8ft 18,4ft 27,6ft 36,8ft 46ft 55,2ft 73,6ft 92ft

LINEAR DISTRIBUTION DIAGRAM ELECTRICAL SPECIFICATIONS

6000 Input voltage Input current Input power Effeciency


5500 224V 0,560A 118,7W 15lm/W
5000

4500 Power FC
4000
0,95
3500

3000

2500

2000

1500

1000

500
ISO DIAGRAMS

ISO CANDELA DIAGRAM


90°
10% 621 cd
75°
20% 1243 cd

60° 30% 1864 cd

40% 2486 cd
45°
50% 3107 cd
30° 60% 3729 cd

70% 4350 cd
Vertical angles

15°
80% 4972 cd

90% 5593 cd

-15° Conditions:

Number of c-planes: 2
-30°
Candela at center: 6215 cd
-45°

-60°

-75°

Horizontal angles

ISO LUX DIAGRAM


10m 32,8f
3% 1,86 lx

8m 26,2f 5% 3,11 lx

10% 6,21 lx
6m 19,7f 30% 18,6 lx

50% 31,1 lx
4m 13,1f

2m 6,6f

0m 0f Conditions:

Number of c-planes: 2
-2m -6,6f
Lux at center: 62,1 lx

-4m -13,1f

-6m -19,7f

Lux distribution on a surface


-8m -26,2f when lamp is mounted at 10
meters from the surface.

Mounting height: 10 meters (33 feet)


Total lumen output:

1743 lm

Peak candela output:

17513 cd

PRODUCT NAME: 165 180 165


150 150
VERSAPAR
135 135

MEASURAMENT CONDITIONS: 120 120

Beam angle:
105 105
Med Zoom
90 90
Target:
Full On 75 75

60 60

Operator: 45 45
Paolo Carvone 30 30
15 0 15

Date and time:


25/05/2020 11:14:51 18,9°
Beam angle 50%: 18,9°
Field angle 10%: 28,2°
Cut off angle 2.5%: 31,9°

Spectra

400 450 500 550 600 650 700 750 800


BEAM DETAILS

Beam angle 50% Field angle 10% Cut off angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

18,9° 28,2° 31,9° 99,9% 99,2%

Distance (meter) 3m 5m 10 m 15 m 20 m
Distance (feet) 9,8 ft 16,4 ft 32,8 ft 49,2 ft 65,6 ft
43 lx
77 lx
174 lx
Lux* 696 lx
1932 lx
18,9°
Beam center

180 fcd
Footcandles* 65 fcd

*measured at
16 fcd
center of beam 7 fcd
4 fcd
Beam width (meter) 1m 1,7 m 3,3 m 5m 6,7 m
Beam width (feet) 3,3 ft 5,5 ft 10,9 ft 16,4 ft 21,8 ft

BEAM INTENSITIES AND WIDTHS


Distance 1m 2m 3m 4m 5m 7,5m 10m 15m 20m 25m 30m 40m 50m

Distance 3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 24,6ft 32,8ft 49,2ft 65,6ft 82ft 98,4ft 131,2ft 164ft

Lux 17392lx 4348lx 1932lx 1087lx 696lx 309lx 174lx 77lx 43lx 28lx 19lx 11lx 7lx

Footcand. 1616fcd 404fcd 180fcd 101fcd 65fcd 29fcd 16fcd 7fcd 4fcd 3fcd 2fcd 1fcd 1fcd

Beam wid. 0,3m 0,7m 1m 1,3m 1,7m 2,5m 3,3m 5m 6,7m 8,3m 10m 13,3m 16,7m

Beam wid. 1,1ft 2,2ft 3,3ft 4,4ft 5,5ft 8,2ft 10,9ft 16,4ft 21,8ft 27,3ft 32,8ft 43,7ft 54,6ft

LINEAR DISTRIBUTION DIAGRAM ELECTRICAL SPECIFICATIONS

Input voltage Input current Input power Effeciency

15000
224V 0,554A 117,7W 15lm/W

Power FC

0,95
10000

5000
ISO DIAGRAMS

ISO CANDELA DIAGRAM


90°
10% 1739 cd
75°
20% 3478 cd

60° 30% 5218 cd

40% 6957 cd
45°
50% 8696 cd
30° 60% 10435 cd

70% 12174 cd
Vertical angles

15°
80% 13913 cd

90% 15653 cd

-15° Conditions:

Number of c-planes: 2
-30°
Candela at center: 17392 cd
-45°

-60°

-75°

Horizontal angles

ISO LUX DIAGRAM


5m 16,4f
3% 5,22 lx

4m 13,1f 5% 8,70 lx

10% 17,4 lx
3m 9,8f 30% 52,2 lx

50% 87,0 lx
2m 6,6f

1m 3,3f

0m 0f Conditions:

Number of c-planes: 2
-1m -3,3f
Lux at center: 174 lx

-2m -6,6f

-3m -9,8f

Lux distribution on a surface


-4m -13,1f when lamp is mounted at 10
meters from the surface.

Mounting height: 10 meters (33 feet)


Total lumen output:

1450 lm

Peak candela output:

78675 cd

PRODUCT NAME: 165 180 165


150 150
VERSAPAR
135 135

MEASURAMENT CONDITIONS: 120 120

Beam angle:
105 105
Min Zoom
90 90
Target:
Full On 75 75

60 60

Operator: 45 45
Paolo Carvone 30 30
15 0 15

Date and time:


25/05/2020 10:53:14 7,9°
Beam angle 50%: 7,9°
Field angle 10%: 11°
Cut off angle 2.5%: 14,1°

Spectra

400 450 500 550 600 650 700 750 800


BEAM DETAILS

Beam angle 50% Field angle 10% Cut off angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

7,9° 11° 14,1° 99,9% 98,5%

Distance (meter) 3m 5m 10 m 15 m 20 m
Distance (feet) 9,8 ft 16,4 ft 32,8 ft 49,2 ft 65,6 ft
197 lx
349 lx
786 lx
Lux* 3144 lx
8734 lx
7,9°
Beam center

811 fcd
Footcandles* 292 fcd

*measured at
73 fcd
center of beam 32 fcd
18 fcd
Beam width (meter) 0,4 m 0,7 m 1,4 m 2,1 m 2,7 m
Beam width (feet) 1,3 ft 2,3 ft 4,5 ft 6,8 ft 9 ft

BEAM INTENSITIES AND WIDTHS


Distance 1m 2m 3m 4m 5m 7,5m 10m 15m 20m 25m 30m 40m 50m

Distance 3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 24,6ft 32,8ft 49,2ft 65,6ft 82ft 98,4ft 131,2ft 164ft

Lux 78610lx 19653lx 8734lx 4913lx 3144lx 1398lx 786lx 349lx 197lx 126lx 87lx 49lx 31lx

Footcand. 7303fcd 1826fcd 811fcd 456fcd 292fcd 130fcd 73fcd 32fcd 18fcd 12fcd 8fcd 5fcd 3fcd

Beam wid. 0,1m 0,3m 0,4m 0,5m 0,7m 1m 1,4m 2,1m 2,7m 3,4m 4,1m 5,5m 6,9m

Beam wid. 0,5ft 0,9ft 1,3ft 1,8ft 2,3ft 3,4ft 4,5ft 6,8ft 9ft 11,3ft 13,5ft 18ft 22,5ft

LINEAR DISTRIBUTION DIAGRAM ELECTRICAL SPECIFICATIONS

75000
Input voltage Input current Input power Effeciency
70000
223V 0,564A 119,4W 12lm/W
65000

60000
Power FC
55000

50000 0,95
45000

40000

35000

30000

25000

20000

15000

10000

5000
ISO DIAGRAMS

ISO CANDELA DIAGRAM


90°
10% 7861 cd
75°
20% 15722 cd

60° 30% 23583 cd

40% 31444 cd
45°
50% 39305 cd
30° 60% 47166 cd

70% 55027 cd
Vertical angles

15°
80% 62888 cd

90% 70749 cd

-15° Conditions:

Number of c-planes: 2
-30°
Candela at center: 78610 cd
-45°

-60°

-75°

Horizontal angles

ISO LUX DIAGRAM


5m 16,4f
3% 23,6 lx

4m 13,1f 5% 39,3 lx

10% 78,6 lx
3m 9,8f 30% 236 lx

50% 393 lx
2m 6,6f

1m 3,3f

0m 0f Conditions:

Number of c-planes: 2
-1m -3,3f
Lux at center: 786 lx

-2m -6,6f

-3m -9,8f

Lux distribution on a surface


-4m -13,1f when lamp is mounted at 10
meters from the surface.

Mounting height: 10 meters (33 feet)


Total lumen output:

274 lm

Peak candela output:

964 cd

PRODUCT NAME: 165 180 165


150 150
VERSAPAR
135 135

MEASURAMENT CONDITIONS: 120 120

Beam angle:
105 105
Max Zoom
90 90
Target:
Red 75 75

60 60

Operator: 45 45
Paolo Carvone 30 30
15 0 15

Date and time:


25/05/2020 11:10:07 31,1°
Beam angle 50%: 31,1°
Field angle 10%: 48,5°
Cut off angle 2.5%: 60,7°

Spectra

400 450 500 550 600 650 700 750 800


BEAM DETAILS

Beam angle 50% Field angle 10% Cut off angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

31,1° 48,5° 60,7° 99,6% 99,1%

Distance (meter) 3m 5m 10 m 15 m 20 m
Distance (feet) 9,8 ft 16,4 ft 32,8 ft 49,2 ft 65,6 ft
2 lx
4 lx
10 lx
Lux* 38 lx
106 lx
31,1°
Beam center

10 fcd
Footcandles* 4 fcd

*measured at
1 fcd
center of beam 0 fcd
0 fcd
Beam width (meter) 1,7 m 2,8 m 5,6 m 8,3 m 11,1 m
Beam width (feet) 5,4 ft 9,1 ft 18,2 ft 27,4 ft 36,5 ft

BEAM INTENSITIES AND WIDTHS


Distance 1m 2m 3m 4m 5m 7,5m 10m 15m 20m 25m 30m 40m 50m

Distance 3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 24,6ft 32,8ft 49,2ft 65,6ft 82ft 98,4ft 131,2ft 164ft

Lux 958lx 239lx 106lx 60lx 38lx 17lx 10lx 4lx 2lx 2lx 1lx 1lx 0lx

Footcand. 89fcd 22fcd 10fcd 6fcd 4fcd 2fcd 1fcd 0fcd 0fcd 0fcd 0fcd 0fcd 0fcd

Beam wid. 0,6m 1,1m 1,7m 2,2m 2,8m 4,2m 5,6m 8,3m 11,1m 13,9m 16,7m 22,2m 27,8m

Beam wid. 1,8ft 3,7ft 5,4ft 7,3ft 9,1ft 13,7ft 18,2ft 27,4ft 36,5ft 45,6ft 54,7ft 72,9ft 91,2ft

LINEAR DISTRIBUTION DIAGRAM ELECTRICAL SPECIFICATIONS

950 Input voltage Input current Input power Effeciency


900
850 225V 0,203A 36,2W 8lm/W
800
750
700
650
600
550
500
450
400
350
300
250
200
150
100
50
ISO DIAGRAMS

ISO CANDELA DIAGRAM


90°
10% 96 cd
75°
20% 192 cd

60° 30% 287 cd

40% 383 cd
45°
50% 479 cd
30° 60% 575 cd

70% 670 cd
Vertical angles

15°
80% 766 cd

90% 862 cd

-15° Conditions:

Number of c-planes: 2
-30°
Candela at center: 958 cd
-45°

-60°

-75°

Horizontal angles

ISO LUX DIAGRAM


10m 32,8f
3% 0,287 lx

8m 26,2f 5% 0,479 lx

10% 0,958 lx
6m 19,7f 30% 2,87 lx

50% 4,79 lx
4m 13,1f

2m 6,6f

0m 0f Conditions:

Number of c-planes: 2
-2m -6,6f
Lux at center: 9,58 lx

-4m -13,1f

-6m -19,7f

Lux distribution on a surface


-8m -26,2f when lamp is mounted at 10
meters from the surface.

Mounting height: 10 meters (33 feet)


Total lumen output:

269 lm

Peak candela output:

2671 cd

PRODUCT NAME: 165 180 165


150 150
VERSAPAR
135 135

MEASURAMENT CONDITIONS: 120 120

Beam angle:
105 105
Med Zoom
90 90
Target:
Red 75 75

60 60

Operator: 45 45
Paolo Carvone 30 30
15 0 15

Date and time:


25/05/2020 11:16:36 18,9°
Beam angle 50%: 18,9°
Field angle 10%: 28,2°
Cut off angle 2.5%: 32,2°

Spectra

400 450 500 550 600 650 700 750 800


BEAM DETAILS

Beam angle 50% Field angle 10% Cut off angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

18,9° 28,2° 32,2° 99,4% 98,4%

Distance (meter) 3m 5m 10 m 15 m 20 m
Distance (feet) 9,8 ft 16,4 ft 32,8 ft 49,2 ft 65,6 ft
7 lx
12 lx
26 lx
Lux* 104 lx
289 lx
18,9°
Beam center

27 fcd
Footcandles* 10 fcd

*measured at
2 fcd
center of beam 1 fcd
1 fcd
Beam width (meter) 1m 1,7 m 3,3 m 5m 6,7 m
Beam width (feet) 3,3 ft 5,5 ft 10,9 ft 16,4 ft 21,8 ft

BEAM INTENSITIES AND WIDTHS


Distance 1m 2m 3m 4m 5m 7,5m 10m 15m 20m 25m 30m 40m 50m

Distance 3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 24,6ft 32,8ft 49,2ft 65,6ft 82ft 98,4ft 131,2ft 164ft

Lux 2604lx 651lx 289lx 163lx 104lx 46lx 26lx 12lx 7lx 4lx 3lx 2lx 1lx

Footcand. 242fcd 60fcd 27fcd 15fcd 10fcd 4fcd 2fcd 1fcd 1fcd 0fcd 0fcd 0fcd 0fcd

Beam wid. 0,3m 0,7m 1m 1,3m 1,7m 2,5m 3,3m 5m 6,7m 8,3m 10m 13,3m 16,6m

Beam wid. 1,1ft 2,2ft 3,3ft 4,4ft 5,5ft 8,2ft 10,9ft 16,4ft 21,8ft 27,3ft 32,8ft 43,7ft 54,6ft

LINEAR DISTRIBUTION DIAGRAM ELECTRICAL SPECIFICATIONS

Input voltage Input current Input power Effeciency


2500
224V 0,197A 34,9W 8lm/W

2000

1500

1000

500
ISO DIAGRAMS

ISO CANDELA DIAGRAM


90°
10% 260 cd
75°
20% 521 cd

60° 30% 781 cd

40% 1042 cd
45°
50% 1302 cd
30° 60% 1562 cd

70% 1823 cd
Vertical angles

15°
80% 2083 cd

90% 2344 cd

-15° Conditions:

Number of c-planes: 2
-30°
Candela at center: 2604 cd
-45°

-60°

-75°

Horizontal angles

ISO LUX DIAGRAM


5m 16,4f
3% 0,781 lx

4m 13,1f 5% 1,30 lx

10% 2,60 lx
3m 9,8f 30% 7,81 lx

50% 13,0 lx
2m 6,6f

1m 3,3f

0m 0f Conditions:

Number of c-planes: 2
-1m -3,3f
Lux at center: 26,0 lx

-2m -6,6f

-3m -9,8f

Lux distribution on a surface


-4m -13,1f when lamp is mounted at 10
meters from the surface.

Mounting height: 10 meters (33 feet)


Total lumen output:

238 lm

Peak candela output:

12818 cd

PRODUCT NAME: 165 180 165


150 150
VERSAPAR
135 135

MEASURAMENT CONDITIONS: 120 120

Beam angle:
105 105
Min Zoom
90 90
Target:
Red 75 75

60 60

Operator: 45 45
Paolo Carvone 30 30
15 0 15

Date and time:


25/05/2020 11:02:35 7,8°
Beam angle 50%: 7,8°
Field angle 10%: 11,1°
Cut off angle 2.5%: 13,7°

Spectra

400 450 500 550 600 650 700 750 800


BEAM DETAILS

Beam angle 50% Field angle 10% Cut off angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

7,8° 11,1° 13,7° 99,6% 97,6%

Distance (meter) 3m 5m 10 m 15 m 20 m
Distance (feet) 9,8 ft 16,4 ft 32,8 ft 49,2 ft 65,6 ft
32 lx
57 lx
128 lx
Lux* 511 lx
1420 lx
7,8°
Beam center

132 fcd
Footcandles* 47 fcd

*measured at
12 fcd
center of beam 5 fcd
3 fcd
Beam width (meter) 0,4 m 0,7 m 1,4 m 2,1 m 2,7 m
Beam width (feet) 1,3 ft 2,2 ft 4,5 ft 6,7 ft 9 ft

BEAM INTENSITIES AND WIDTHS


Distance 1m 2m 3m 4m 5m 7,5m 10m 15m 20m 25m 30m 40m 50m

Distance 3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 24,6ft 32,8ft 49,2ft 65,6ft 82ft 98,4ft 131,2ft 164ft

Lux 12776lx 3194lx 1420lx 799lx 511lx 227lx 128lx 57lx 32lx 20lx 14lx 8lx 5lx

Footcand. 1187fcd 297fcd 132fcd 74fcd 47fcd 21fcd 12fcd 5fcd 3fcd 2fcd 1fcd 1fcd 0fcd

Beam wid. 0,1m 0,3m 0,4m 0,5m 0,7m 1m 1,4m 2,1m 2,7m 3,4m 4,1m 5,5m 6,9m

Beam wid. 0,5ft 0,9ft 1,3ft 1,8ft 2,2ft 3,4ft 4,5ft 6,7ft 9ft 11,2ft 13,5ft 18ft 22,5ft

LINEAR DISTRIBUTION DIAGRAM ELECTRICAL SPECIFICATIONS

Input voltage Input current Input power Effeciency

223V 0,200A 35,5W 7lm/W


10000

5000
ISO DIAGRAMS

ISO CANDELA DIAGRAM


90°
10% 1278 cd
75°
20% 2555 cd

60° 30% 3833 cd

40% 5110 cd
45°
50% 6388 cd
30° 60% 7666 cd

70% 8943 cd
Vertical angles

15°
80% 10221 cd

90% 11498 cd

-15° Conditions:

Number of c-planes: 2
-30°
Candela at center: 12776 cd
-45°

-60°

-75°

Horizontal angles

ISO LUX DIAGRAM


5m 16,4f
3% 3,83 lx

4m 13,1f 5% 6,39 lx

10% 12,8 lx
3m 9,8f 30% 38,3 lx

50% 63,9 lx
2m 6,6f

1m 3,3f

0m 0f Conditions:

Number of c-planes: 2
-1m -3,3f
Lux at center: 128 lx

-2m -6,6f

-3m -9,8f

Lux distribution on a surface


-4m -13,1f when lamp is mounted at 10
meters from the surface.

Mounting height: 10 meters (33 feet)


Total lumen output:

689 lm

Peak candela output:

2456 cd

PRODUCT NAME: 165 180 165


150 150
VERSAPAR
135 135

MEASURAMENT CONDITIONS: 120 120

Beam angle:
105 105
Max Zoom
90 90
Target:
Green 75 75

60 60

Operator: 45 45
Paolo Carvone 30 30
15 0 15

Date and time:


25/05/2020 11:11:37 30,8°
Beam angle 50%: 30,8°
Field angle 10%: 48,7°
Cut off angle 2.5%: 61,1°

Spectra

400 450 500 550 600 650 700 750 800


BEAM DETAILS

Beam angle 50% Field angle 10% Cut off angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

30,8° 48,7° 61,1° 99,7% 99,4%

Distance (meter) 3m 5m 10 m 15 m 20 m
Distance (feet) 9,8 ft 16,4 ft 32,8 ft 49,2 ft 65,6 ft
6 lx
11 lx
24 lx
Lux* 98 lx
272 lx
30,8°
Beam center

25 fcd
Footcandles* 9 fcd

*measured at
2 fcd
center of beam 1 fcd
1 fcd
Beam width (meter) 1,7 m 2,8 m 5,5 m 8,3 m 11 m
Beam width (feet) 5,4 ft 9 ft 18,1 ft 27,1 ft 36,1 ft

BEAM INTENSITIES AND WIDTHS


Distance 1m 2m 3m 4m 5m 7,5m 10m 15m 20m 25m 30m 40m 50m

Distance 3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 24,6ft 32,8ft 49,2ft 65,6ft 82ft 98,4ft 131,2ft 164ft

Lux 2449lx 612lx 272lx 153lx 98lx 44lx 24lx 11lx 6lx 4lx 3lx 2lx 1lx

Footcand. 228fcd 57fcd 25fcd 14fcd 9fcd 4fcd 2fcd 1fcd 1fcd 0fcd 0fcd 0fcd 0fcd

Beam wid. 0,6m 1,1m 1,7m 2,2m 2,8m 4,1m 5,5m 8,3m 11m 13,8m 16,5m 22m 27,5m

Beam wid. 1,8ft 3,6ft 5,4ft 7,2ft 9ft 13,5ft 18,1ft 27,1ft 36,1ft 45,1ft 54,2ft 72,2ft 90,3ft

LINEAR DISTRIBUTION DIAGRAM ELECTRICAL SPECIFICATIONS

Input voltage Input current Input power Effeciency

225V 0,218A 39,6W 17lm/W


2000

1500

1000

500
ISO DIAGRAMS

ISO CANDELA DIAGRAM


90°
10% 245 cd
75°
20% 490 cd

60° 30% 735 cd

40% 980 cd
45°
50% 1225 cd
30° 60% 1469 cd

70% 1714 cd
Vertical angles

15°
80% 1959 cd

90% 2204 cd

-15° Conditions:

Number of c-planes: 2
-30°
Candela at center: 2449 cd
-45°

-60°

-75°

Horizontal angles

ISO LUX DIAGRAM


10m 32,8f
3% 0,735 lx

8m 26,2f 5% 1,22 lx

10% 2,45 lx
6m 19,7f 30% 7,35 lx

50% 12,2 lx
4m 13,1f

2m 6,6f

0m 0f Conditions:

Number of c-planes: 2
-2m -6,6f
Lux at center: 24,5 lx

-4m -13,1f

-6m -19,7f

Lux distribution on a surface


-8m -26,2f when lamp is mounted at 10
meters from the surface.

Mounting height: 10 meters (33 feet)


Total lumen output:

680 lm

Peak candela output:

6948 cd

PRODUCT NAME: 165 180 165


150 150
VERSAPAR
135 135

MEASURAMENT CONDITIONS: 120 120

Beam angle:
105 105
Med Zoom
90 90
Target:
Green 75 75

60 60

Operator: 45 45
Paolo Carvone 30 30
15 0 15

Date and time:


25/05/2020 11:18:49 18,6°
Beam angle 50%: 18,6°
Field angle 10%: 28°
Cut off angle 2.5%: 31,9°

Spectra

400 450 500 550 600 650 700 750 800


BEAM DETAILS

Beam angle 50% Field angle 10% Cut off angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

18,6° 28° 31,9° 99,5% 98,5%

Distance (meter) 3m 5m 10 m 15 m 20 m
Distance (feet) 9,8 ft 16,4 ft 32,8 ft 49,2 ft 65,6 ft
17 lx
31 lx
69 lx
Lux* 278 lx
772 lx
18,6°
Beam center

72 fcd
Footcandles* 26 fcd

*measured at
6 fcd
center of beam 3 fcd
2 fcd
Beam width (meter) 1m 1,6 m 3,3 m 4,9 m 6,6 m
Beam width (feet) 3,2 ft 5,4 ft 10,7 ft 16,1 ft 21,5 ft

BEAM INTENSITIES AND WIDTHS


Distance 1m 2m 3m 4m 5m 7,5m 10m 15m 20m 25m 30m 40m 50m

Distance 3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 24,6ft 32,8ft 49,2ft 65,6ft 82ft 98,4ft 131,2ft 164ft

Lux 6948lx 1737lx 772lx 434lx 278lx 124lx 69lx 31lx 17lx 11lx 8lx 4lx 3lx

Footcand. 646fcd 161fcd 72fcd 40fcd 26fcd 11fcd 6fcd 3fcd 2fcd 1fcd 1fcd 0fcd 0fcd

Beam wid. 0,3m 0,7m 1m 1,3m 1,6m 2,5m 3,3m 4,9m 6,6m 8,2m 9,8m 13,1m 16,4m

Beam wid. 1,1ft 2,2ft 3,2ft 4,3ft 5,4ft 8,1ft 10,7ft 16,1ft 21,5ft 26,9ft 32,2ft 43ft 53,7ft

LINEAR DISTRIBUTION DIAGRAM ELECTRICAL SPECIFICATIONS

Input voltage Input current Input power Effeciency


6500

6000 224V 0,212A 38,3W 18lm/W


5500

5000

4500

4000

3500

3000

2500

2000

1500

1000

500
ISO DIAGRAMS

ISO CANDELA DIAGRAM


90°
10% 695 cd
75°
20% 1390 cd

60° 30% 2084 cd

40% 2779 cd
45°
50% 3474 cd
30° 60% 4169 cd

70% 4864 cd
Vertical angles

15°
80% 5559 cd

90% 6253 cd

-15° Conditions:

Number of c-planes: 2
-30°
Candela at center: 6948 cd
-45°

-60°

-75°

Horizontal angles

ISO LUX DIAGRAM


5m 16,4f
3% 2,08 lx

4m 13,1f 5% 3,47 lx

10% 6,95 lx
3m 9,8f 30% 20,8 lx

50% 34,7 lx
2m 6,6f

1m 3,3f

0m 0f Conditions:

Number of c-planes: 2
-1m -3,3f
Lux at center: 69,5 lx

-2m -6,6f

-3m -9,8f

Lux distribution on a surface


-4m -13,1f when lamp is mounted at 10
meters from the surface.

Mounting height: 10 meters (33 feet)


Total lumen output:

552 lm

Peak candela output:

29438 cd

PRODUCT NAME: 165 180 165


150 150
VERSAPAR
135 135

MEASURAMENT CONDITIONS: 120 120

Beam angle:
105 105
Min Zoom
90 90
Target:
Green 75 75

60 60

Operator: 45 45
Paolo Carvone 30 30
15 0 15

Date and time:


25/05/2020 11:00:41 7,8°
Beam angle 50%: 7,8°
Field angle 10%: 11,2°
Cut off angle 2.5%: 14,3°

Spectra

400 450 500 550 600 650 700 750 800


BEAM DETAILS

Beam angle 50% Field angle 10% Cut off angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

7,8° 11,2° 14,3° 99,7% 97,7%

Distance (meter) 3m 5m 10 m 15 m 20 m
Distance (feet) 9,8 ft 16,4 ft 32,8 ft 49,2 ft 65,6 ft
74 lx
131 lx
294 lx
Lux* 1176 lx
3268 lx
7,8°
Beam center

304 fcd
Footcandles* 109 fcd

*measured at
27 fcd
center of beam 12 fcd
7 fcd
Beam width (meter) 0,4 m 0,7 m 1,4 m 2,1 m 2,7 m
Beam width (feet) 1,3 ft 2,2 ft 4,5 ft 6,7 ft 9 ft

BEAM INTENSITIES AND WIDTHS


Distance 1m 2m 3m 4m 5m 7,5m 10m 15m 20m 25m 30m 40m 50m

Distance 3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 24,6ft 32,8ft 49,2ft 65,6ft 82ft 98,4ft 131,2ft 164ft

Lux 29409lx 7352lx 3268lx 1838lx 1176lx 523lx 294lx 131lx 74lx 47lx 33lx 18lx 12lx

Footcand. 2732fcd 683fcd 304fcd 171fcd 109fcd 49fcd 27fcd 12fcd 7fcd 4fcd 3fcd 2fcd 1fcd

Beam wid. 0,1m 0,3m 0,4m 0,5m 0,7m 1m 1,4m 2,1m 2,7m 3,4m 4,1m 5,5m 6,8m

Beam wid. 0,5ft 0,9ft 1,3ft 1,8ft 2,2ft 3,4ft 4,5ft 6,7ft 9ft 11,2ft 13,5ft 18ft 22,4ft

LINEAR DISTRIBUTION DIAGRAM ELECTRICAL SPECIFICATIONS

Input voltage Input current Input power Effeciency

25000
224V 0,214A 38,4W 14lm/W

20000

15000

10000

5000
ISO DIAGRAMS

ISO CANDELA DIAGRAM


90°
10% 2941 cd
75°
20% 5882 cd

60° 30% 8823 cd

40% 11763 cd
45°
50% 14704 cd
30° 60% 17645 cd

70% 20586 cd
Vertical angles

15°
80% 23527 cd

90% 26468 cd

-15° Conditions:

Number of c-planes: 2
-30°
Candela at center: 29409 cd
-45°

-60°

-75°

Horizontal angles

ISO LUX DIAGRAM


5m 16,4f
3% 8,82 lx

4m 13,1f 5% 14,7 lx

10% 29,4 lx
3m 9,8f 30% 88,2 lx

50% 147 lx
2m 6,6f

1m 3,3f

0m 0f Conditions:

Number of c-planes: 2
-1m -3,3f
Lux at center: 294 lx

-2m -6,6f

-3m -9,8f

Lux distribution on a surface


-4m -13,1f when lamp is mounted at 10
meters from the surface.

Mounting height: 10 meters (33 feet)


Total lumen output:

124 lm

Peak candela output:

450 cd

PRODUCT NAME: 165 180 165


150 150
VERSAPAR
135 135

MEASURAMENT CONDITIONS: 120 120

Beam angle:
105 105
Max Zoom
90 90
Target:
Blue 75 75

60 60

Operator: 45 45
Paolo Carvone 30 30
15 0 15

Date and time:


25/05/2020 11:13:08 30,5°
Beam angle 50%: 30,5°
Field angle 10%: 48,2°
Cut off angle 2.5%: 60,3°

Spectra

400 450 500 550 600 650 700 750 800


BEAM DETAILS

Beam angle 50% Field angle 10% Cut off angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

30,5° 48,2° 60,3° 99,7% 99,3%

Distance (meter) 3m 5m 10 m 15 m 20 m
Distance (feet) 9,8 ft 16,4 ft 32,8 ft 49,2 ft 65,6 ft
1 lx
2 lx
5 lx
Lux* 18 lx
50 lx
30,5°
Beam center

5 fcd
Footcandles* 2 fcd

*measured at
0 fcd
center of beam 0 fcd
0 fcd
Beam width (meter) 1,6 m 2,7 m 5,4 m 8,2 m 10,9 m
Beam width (feet) 5,3 ft 8,9 ft 17,9 ft 26,8 ft 35,7 ft

BEAM INTENSITIES AND WIDTHS


Distance 1m 2m 3m 4m 5m 7,5m 10m 15m 20m 25m 30m 40m 50m

Distance 3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 24,6ft 32,8ft 49,2ft 65,6ft 82ft 98,4ft 131,2ft 164ft

Lux 450lx 113lx 50lx 28lx 18lx 8lx 5lx 2lx 1lx 1lx 1lx 0lx 0lx

Footcand. 42fcd 10fcd 5fcd 3fcd 2fcd 1fcd 0fcd 0fcd 0fcd 0fcd 0fcd 0fcd 0fcd

Beam wid. 0,5m 1,1m 1,6m 2,2m 2,7m 4,1m 5,4m 8,2m 10,9m 13,6m 16,3m 21,8m 27,2m

Beam wid. 1,8ft 3,6ft 5,3ft 7,1ft 8,9ft 13,4ft 17,9ft 26,8ft 35,7ft 44,7ft 53,6ft 71,5ft 89,3ft

LINEAR DISTRIBUTION DIAGRAM ELECTRICAL SPECIFICATIONS

450
Input voltage Input current Input power Effeciency
400 225V 0,213A 38,4W 3lm/W
350

300

250

200

150

100

50
ISO DIAGRAMS

ISO CANDELA DIAGRAM


90°
10% 45 cd
75°
20% 90 cd

60° 30% 135 cd

40% 180 cd
45°
50% 225 cd
30° 60% 270 cd

70% 315 cd
Vertical angles

15°
80% 360 cd

90% 405 cd

-15° Conditions:

Number of c-planes: 2
-30°
Candela at center: 450 cd
-45°

-60°

-75°

Horizontal angles

ISO LUX DIAGRAM


10m 32,8f
3% 0,135 lx

8m 26,2f 5% 0,225 lx

10% 0,450 lx
6m 19,7f 30% 1,35 lx

50% 2,25 lx
4m 13,1f

2m 6,6f

0m 0f Conditions:

Number of c-planes: 2
-2m -6,6f
Lux at center: 4,50 lx

-4m -13,1f

-6m -19,7f

Lux distribution on a surface


-8m -26,2f when lamp is mounted at 10
meters from the surface.

Mounting height: 10 meters (33 feet)


Total lumen output:

122 lm

Peak candela output:

1291 cd

PRODUCT NAME: 165 180 165


150 150
VERSAPAR
135 135

MEASURAMENT CONDITIONS: 120 120

Beam angle:
105 105
Med Zoom
90 90
Target:
Blue 75 75

60 60

Operator: 45 45
Paolo Carvone 30 30
15 0 15

Date and time:


25/05/2020 11:23:11 18,3°
Beam angle 50%: 18,3°
Field angle 10%: 27,4°
Cut off angle 2.5%: 30,9°

Spectra

400 450 500 550 600 650 700 750 800


BEAM DETAILS

Beam angle 50% Field angle 10% Cut off angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

18,3° 27,4° 30,9° 99,7% 98,7%

Distance (meter) 3m 5m 10 m 15 m 20 m
Distance (feet) 9,8 ft 16,4 ft 32,8 ft 49,2 ft 65,6 ft
3 lx
6 lx
13 lx
Lux* 52 lx
143 lx
18,3°
Beam center

13 fcd
Footcandles* 5 fcd

*measured at
1 fcd
center of beam 1 fcd
0 fcd
Beam width (meter) 1m 1,6 m 3,2 m 4,8 m 6,4 m
Beam width (feet) 3,2 ft 5,3 ft 10,6 ft 15,9 ft 21,1 ft

BEAM INTENSITIES AND WIDTHS


Distance 1m 2m 3m 4m 5m 7,5m 10m 15m 20m 25m 30m 40m 50m

Distance 3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 24,6ft 32,8ft 49,2ft 65,6ft 82ft 98,4ft 131,2ft 164ft

Lux 1289lx 322lx 143lx 81lx 52lx 23lx 13lx 6lx 3lx 2lx 1lx 1lx 1lx

Footcand. 120fcd 30fcd 13fcd 7fcd 5fcd 2fcd 1fcd 1fcd 0fcd 0fcd 0fcd 0fcd 0fcd

Beam wid. 0,3m 0,6m 1m 1,3m 1,6m 2,4m 3,2m 4,8m 6,4m 8,1m 9,7m 12,9m 16,1m

Beam wid. 1,1ft 2,1ft 3,2ft 4,2ft 5,3ft 7,9ft 10,6ft 15,9ft 21,1ft 26,4ft 31,7ft 42,3ft 52,8ft

LINEAR DISTRIBUTION DIAGRAM ELECTRICAL SPECIFICATIONS

Input voltage Input current Input power Effeciency

224V 0,209A 37,2W 3lm/W


1000

500
ISO DIAGRAMS

ISO CANDELA DIAGRAM


90°
10% 129 cd
75°
20% 258 cd

60° 30% 387 cd

40% 515 cd
45°
50% 644 cd
30° 60% 773 cd

70% 902 cd
Vertical angles

15°
80% 1031 cd

90% 1160 cd

-15° Conditions:

Number of c-planes: 2
-30°
Candela at center: 1289 cd
-45°

-60°

-75°

Horizontal angles

ISO LUX DIAGRAM


5m 16,4f
3% 0,387 lx

4m 13,1f 5% 0,644 lx

10% 1,29 lx
3m 9,8f 30% 3,87 lx

50% 6,44 lx
2m 6,6f

1m 3,3f

0m 0f Conditions:

Number of c-planes: 2
-1m -3,3f
Lux at center: 12,9 lx

-2m -6,6f

-3m -9,8f

Lux distribution on a surface


-4m -13,1f when lamp is mounted at 10
meters from the surface.

Mounting height: 10 meters (33 feet)


Total lumen output:

98,0 lm

Peak candela output:

5224 cd

PRODUCT NAME: 165 180 165


150 150
VERSAPAR
135 135

MEASURAMENT CONDITIONS: 120 120

Beam angle:
105 105
Min Zoom
90 90
Target:
Blue 75 75

60 60

Operator: 45 45
Paolo Carvone 30 30
15 0 15

Date and time:


25/05/2020 11:04:15 7,8°
Beam angle 50%: 7,8°
Field angle 10%: 11°
Cut off angle 2.5%: 14,2°

Spectra

400 450 500 550 600 650 700 750 800


BEAM DETAILS

Beam angle 50% Field angle 10% Cut off angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

7,8° 11° 14,2° 99,3% 96,9%

Distance (meter) 3m 5m 10 m 15 m 20 m
Distance (feet) 9,8 ft 16,4 ft 32,8 ft 49,2 ft 65,6 ft
13 lx
23 lx
52 lx
Lux* 209 lx
579 lx
7,8°
Beam center

54 fcd
Footcandles* 19 fcd

*measured at
5 fcd
center of beam 2 fcd
1 fcd
Beam width (meter) 0,4 m 0,7 m 1,4 m 2m 2,7 m
Beam width (feet) 1,3 ft 2,2 ft 4,5 ft 6,7 ft 9 ft

BEAM INTENSITIES AND WIDTHS


Distance 1m 2m 3m 4m 5m 7,5m 10m 15m 20m 25m 30m 40m 50m

Distance 3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 24,6ft 32,8ft 49,2ft 65,6ft 82ft 98,4ft 131,2ft 164ft

Lux 5214lx 1304lx 579lx 326lx 209lx 93lx 52lx 23lx 13lx 8lx 6lx 3lx 2lx

Footcand. 484fcd 121fcd 54fcd 30fcd 19fcd 9fcd 5fcd 2fcd 1fcd 1fcd 1fcd 0fcd 0fcd

Beam wid. 0,1m 0,3m 0,4m 0,5m 0,7m 1m 1,4m 2m 2,7m 3,4m 4,1m 5,5m 6,8m

Beam wid. 0,5ft 0,9ft 1,3ft 1,8ft 2,2ft 3,4ft 4,5ft 6,7ft 9ft 11,2ft 13,4ft 17,9ft 22,4ft

LINEAR DISTRIBUTION DIAGRAM ELECTRICAL SPECIFICATIONS

5000
Input voltage Input current Input power Effeciency

4500 224V 0,209A 37,4W 3lm/W

4000

3500

3000

2500

2000

1500

1000

500
ISO DIAGRAMS

ISO CANDELA DIAGRAM


90°
10% 521 cd
75°
20% 1043 cd

60° 30% 1564 cd

40% 2086 cd
45°
50% 2607 cd
30° 60% 3128 cd

70% 3650 cd
Vertical angles

15°
80% 4171 cd

90% 4693 cd

-15° Conditions:

Number of c-planes: 2
-30°
Candela at center: 5214 cd
-45°

-60°

-75°

Horizontal angles

ISO LUX DIAGRAM


5m 16,4f
3% 1,56 lx

4m 13,1f 5% 2,61 lx

10% 5,21 lx
3m 9,8f 30% 15,6 lx

50% 26,1 lx
2m 6,6f

1m 3,3f

0m 0f Conditions:

Number of c-planes: 2
-1m -3,3f
Lux at center: 52,1 lx

-2m -6,6f

-3m -9,8f

Lux distribution on a surface


-4m -13,1f when lamp is mounted at 10
meters from the surface.

Mounting height: 10 meters (33 feet)


Total lumen output:

853 lm

Peak candela output:

2948 cd

PRODUCT NAME: 165 180 165


150 150
VERSAPAR
135 135

MEASURAMENT CONDITIONS: 120 120

Beam angle:
105 105
Max Zoom
90 90
Target:
White 75 75

60 60

Operator: 45 45
Paolo Carvone 30 30
15 0 15

Date and time:


27/05/2020 13:27:00 31,4°
Beam angle 50%: 31,4°
Field angle 10%: 49,3°
Cut off angle 2.5%: 61,8°

Spectra

400 450 500 550 600 650 700 750 800


BEAM DETAILS

Beam angle 50% Field angle 10% Cut off angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

31,4° 49,3° 61,8° 99,9% 99,5%

Distance (meter) 3m 5m 10 m 15 m 20 m
Distance (feet) 9,8 ft 16,4 ft 32,8 ft 49,2 ft 65,6 ft
7 lx
13 lx
29 lx
Lux* 117 lx
326 lx
31,4°
Beam center

30 fcd
Footcandles* 11 fcd

*measured at
3 fcd
center of beam 1 fcd
1 fcd
Beam width (meter) 1,7 m 2,8 m 5,6 m 8,4 m 11,2 m
Beam width (feet) 5,5 ft 9,2 ft 18,4 ft 27,7 ft 36,9 ft

BEAM INTENSITIES AND WIDTHS


Distance 1m 2m 3m 4m 5m 7,5m 10m 15m 20m 25m 30m 40m 50m

Distance 3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 24,6ft 32,8ft 49,2ft 65,6ft 82ft 98,4ft 131,2ft 164ft

Lux 2931lx 733lx 326lx 183lx 117lx 52lx 29lx 13lx 7lx 5lx 3lx 2lx 1lx

Footcand. 272fcd 68fcd 30fcd 17fcd 11fcd 5fcd 3fcd 1fcd 1fcd 0fcd 0fcd 0fcd 0fcd

Beam wid. 0,6m 1,1m 1,7m 2,2m 2,8m 4,2m 5,6m 8,4m 11,2m 14,1m 16,9m 22,5m 28,1m

Beam wid. 1,9ft 3,7ft 5,5ft 7,4ft 9,2ft 13,8ft 18,4ft 27,7ft 36,9ft 46,1ft 55,3ft 73,8ft 92,2ft

LINEAR DISTRIBUTION DIAGRAM ELECTRICAL SPECIFICATIONS

Input voltage Input current Input power Effeciency

227V 0,217A 39,7W 21lm/W


2500

2000

1500

1000

500
ISO DIAGRAMS

ISO CANDELA DIAGRAM


90°
10% 293 cd
75°
20% 586 cd

60° 30% 879 cd

40% 1172 cd
45°
50% 1465 cd
30° 60% 1759 cd

70% 2052 cd
Vertical angles

15°
80% 2345 cd

90% 2638 cd

-15° Conditions:

Number of c-planes: 2
-30°
Candela at center: 2931 cd
-45°

-60°

-75°

Horizontal angles

ISO LUX DIAGRAM


10m 32,8f
3% 0,879 lx

8m 26,2f 5% 1,47 lx

10% 2,93 lx
6m 19,7f 30% 8,79 lx

50% 14,7 lx
4m 13,1f

2m 6,6f

0m 0f Conditions:

Number of c-planes: 2
-2m -6,6f
Lux at center: 29,3 lx

-4m -13,1f

-6m -19,7f

Lux distribution on a surface


-8m -26,2f when lamp is mounted at 10
meters from the surface.

Mounting height: 10 meters (33 feet)


Total lumen output:

826 lm

Peak candela output:

8018 cd

PRODUCT NAME: 165 180 165


150 150
VERSAPAR
135 135

MEASURAMENT CONDITIONS: 120 120

Beam angle:
105 105
Med Zoom
90 90
Target:
White 75 75

60 60

Operator: 45 45
Paolo Carvone 30 30
15 0 15

Date and time:


27/05/2020 13:28:36 19°
Beam angle 50%: 19°
Field angle 10%: 28,6°
Cut off angle 2.5%: 32,7°

Spectra

400 450 500 550 600 650 700 750 800


BEAM DETAILS

Beam angle 50% Field angle 10% Cut off angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

19° 28,6° 32,7° 99,8% 98,7%

Distance (meter) 3m 5m 10 m 15 m 20 m
Distance (feet) 9,8 ft 16,4 ft 32,8 ft 49,2 ft 65,6 ft
20 lx
36 lx
80 lx
Lux* 321 lx
891 lx
19°
Beam center

83 fcd
Footcandles* 30 fcd

*measured at
7 fcd
center of beam 3 fcd
2 fcd
Beam width (meter) 1m 1,7 m 3,4 m 5m 6,7 m
Beam width (feet) 3,3 ft 5,5 ft 11 ft 16,5 ft 22 ft

BEAM INTENSITIES AND WIDTHS


Distance 1m 2m 3m 4m 5m 7,5m 10m 15m 20m 25m 30m 40m 50m

Distance 3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 24,6ft 32,8ft 49,2ft 65,6ft 82ft 98,4ft 131,2ft 164ft

Lux 8015lx 2004lx 891lx 501lx 321lx 142lx 80lx 36lx 20lx 13lx 9lx 5lx 3lx

Footcand. 745fcd 186fcd 83fcd 47fcd 30fcd 13fcd 7fcd 3fcd 2fcd 1fcd 1fcd 0fcd 0fcd

Beam wid. 0,3m 0,7m 1m 1,3m 1,7m 2,5m 3,4m 5m 6,7m 8,4m 10,1m 13,4m 16,8m

Beam wid. 1,1ft 2,2ft 3,3ft 4,4ft 5,5ft 8,3ft 11ft 16,5ft 22ft 27,5ft 33ft 44ft 55ft

LINEAR DISTRIBUTION DIAGRAM ELECTRICAL SPECIFICATIONS

8000
Input voltage Input current Input power Effeciency
7500

7000 227V 0,211A 38,1W 22lm/W


6500

6000

5500

5000

4500

4000

3500

3000

2500

2000

1500

1000

500
ISO DIAGRAMS

ISO CANDELA DIAGRAM


90°
10% 802 cd
75°
20% 1603 cd

60° 30% 2405 cd

40% 3206 cd
45°
50% 4008 cd
30° 60% 4809 cd

70% 5611 cd
Vertical angles

15°
80% 6412 cd

90% 7214 cd

-15° Conditions:

Number of c-planes: 2
-30°
Candela at center: 8015 cd
-45°

-60°

-75°

Horizontal angles

ISO LUX DIAGRAM


5m 16,4f
3% 2,40 lx

4m 13,1f 5% 4,01 lx

10% 8,02 lx
3m 9,8f 30% 24,0 lx

50% 40,1 lx
2m 6,6f

1m 3,3f

0m 0f Conditions:

Number of c-planes: 2
-1m -3,3f
Lux at center: 80,2 lx

-2m -6,6f

-3m -9,8f

Lux distribution on a surface


-4m -13,1f when lamp is mounted at 10
meters from the surface.

Mounting height: 10 meters (33 feet)


Total lumen output:

734 lm

Peak candela output:

36162 cd

PRODUCT NAME: 165 180 165


150 150
VERSAPAR
135 135

MEASURAMENT CONDITIONS: 120 120

Beam angle:
105 105
Min Zoom
90 90
Target:
White 75 75

60 60

Operator: 45 45
Paolo Carvone 30 30
15 0 15

Date and time:


27/05/2020 13:30:32 8°
Beam angle 50%: 8°
Field angle 10%: 12°
Cut off angle 2.5%: 14,7°

Spectra

400 450 500 550 600 650 700 750 800


BEAM DETAILS

Beam angle 50% Field angle 10% Cut off angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

8° 12° 14,7° 99,8% 97,6%

Distance (meter) 3m 5m 10 m 15 m 20 m
Distance (feet) 9,8 ft 16,4 ft 32,8 ft 49,2 ft 65,6 ft
90 lx
161 lx
362 lx
Lux* 1446 lx
4018 lx

Beam center

373 fcd
Footcandles* 134 fcd

*measured at
34 fcd
center of beam 15 fcd
8 fcd
Beam width (meter) 0,4 m 0,7 m 1,4 m 2,1 m 2,8 m
Beam width (feet) 1,4 ft 2,3 ft 4,6 ft 6,9 ft 9,2 ft

BEAM INTENSITIES AND WIDTHS


Distance 1m 2m 3m 4m 5m 7,5m 10m 15m 20m 25m 30m 40m 50m

Distance 3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 24,6ft 32,8ft 49,2ft 65,6ft 82ft 98,4ft 131,2ft 164ft

Lux 36162lx 9041lx 4018lx 2260lx 1446lx 643lx 362lx 161lx 90lx 58lx 40lx 23lx 14lx

Footcand. 3360fcd 840fcd 373fcd 210fcd 134fcd 60fcd 34fcd 15fcd 8fcd 5fcd 4fcd 2fcd 1fcd

Beam wid. 0,1m 0,3m 0,4m 0,6m 0,7m 1,1m 1,4m 2,1m 2,8m 3,5m 4,2m 5,6m 7m

Beam wid. 0,5ft 0,9ft 1,4ft 1,8ft 2,3ft 3,5ft 4,6ft 6,9ft 9,2ft 11,5ft 13,8ft 18,4ft 23ft

LINEAR DISTRIBUTION DIAGRAM ELECTRICAL SPECIFICATIONS

35000 Input voltage Input current Input power Effeciency

228V 0,210A 38,0W 19lm/W


30000

25000

20000

15000

10000

5000
ISO DIAGRAMS

ISO CANDELA DIAGRAM


90°
10% 3616 cd
75°
20% 7232 cd

60° 30% 10849 cd

40% 14465 cd
45°
50% 18081 cd
30° 60% 21697 cd

70% 25313 cd
Vertical angles

15°
80% 28930 cd

90% 32546 cd

-15° Conditions:

Number of c-planes: 2
-30°
Candela at center: 36162 cd
-45°

-60°

-75°

Horizontal angles

ISO LUX DIAGRAM


5m 16,4f
3% 10,8 lx

4m 13,1f 5% 18,1 lx

10% 36,2 lx
3m 9,8f 30% 108 lx

50% 181 lx
2m 6,6f

1m 3,3f

0m 0f Conditions:

Number of c-planes: 2
-1m -3,3f
Lux at center: 362 lx

-2m -6,6f

-3m -9,8f

Lux distribution on a surface


-4m -13,1f when lamp is mounted at 10
meters from the surface.

Mounting height: 10 meters (33 feet)