CERTIFICATE OF CONFORMANCE (CoC)

Product Name: GeoCore5


CoC No.: REIPL/CoC/GC5/22-23/67 Date: 23-09-2022
S-22946 Shivalaya Const_Thalikulam
Customer Name: M/s Shivalaya Construction Project/WO No.:
to Kodungallur Road Project
Invoice/challan No.: MTKE000000823 Date: 23-09-2022
Batch No: OM/INV-01847/059/HP/09/22 Quantity: 10,000 Nos.

This is to certify that GeoCore5 supplied with above details meet the requirements as stated in purchase
order/project quality assurance plan.
The average test results on random samples are stated below-

S.N. Parameters Standard Method/Instrument Measured Dimensions (mm)


Dimensions (mm) 1 2 3 4 5 Remarks
1 Dimension (A) 198.00±2.0 Vernier Caliper 197.92 198.28 198.11 197.73 198.38 Accepted
2 Dimension (B) 141.50±2.0 Vernier Caliper 141.80 141.38 141.50 141.63 141.41 Accepted
3 Dimension (C) 169.20±3.0 Vernier Caliper 168.80 168.23 168.75 169.23 169.36 Accepted
4 Dimension (D) 108.00±1.0 Vernier Caliper 107.92 108.21 108.05 107.88 108.22 Accepted
5 Dimension (E) 91.00±1.0 Vernier Caliper 90.90 91.08 91.20 90.89 91.02 Accepted
6 Thickness 1.50±0.5 Vernier Caliper 1.52 1.53 1.50 1.51 1.49 Accepted
7 Appearance Free from surface Visual Yes Yes Yes Yes Yes Accepted
defects

Note: This CoC is based on dimensions check and test performed at supplier premises while pre-dispatch inspection
under controlled conditions. Properties may change due to the storage conditions and variation in temperature.

Prepared and approved by

For Reinforced Earth India Pvt. Ltd.


E-11, Block B1 Extension, Mohan Co-operative Industrial Estate,
Mathura Road, New Delhi-110044, India
Terre Armée W: www.terrearmeeindia.com

IMS DOC NO: REIPL/QAC/FMT/11


REV: 2.0
WEF: 01/04/2021, Page 1 of 1