Lotul 9 Servicemanual Ultf With G-214.semnat

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 60

Service Manual8/7)ZLWK*

Digitally signed by Ermicev Alexandr


Date: 2021.06.17 12:06:03 EEST
Reason: MoldSign Signature
Location: Moldova
,QGH[
:RUNLQJVDIHW\
x *HQHUDOVDIHW\
x (OHFWULFDOVDIHW\
x &KHPLFDODQGELRORJLFDOVDIHW\

 ,QIRUPDWLRQDERXWWKHXQLW
x D,QIRUPDWLRQDERXWWKHIUHH]HU
x E&RQWUROOHU*
x F0RGHOLQIRUPDWLRQ

 7URXEOHVKRRWLQJ5HSDLU
x D*HQHUDORSHUDWLQJSUREOHPV
x E7URXEOHVKRRWLQJVFKHGXOH
x F2SHQLQJRIWKHFRROLQJV\VWHP
x G(YDFXDWLRQRIWKHUHIULJHUDQW
x H&KDQJLQJWKHGU\ILOWHU
x I&KDQJLQJWKHFRPSUHVVRU
x J3UHVVXUHWHVWLQJDQGOHDNGHWHFWLRQ
x K9DFXXPVXFWLRQ9DFXXPFKHFN
x L5HIULJHUDQWILOOLQJZLWK(3+&
x M(OHFWULFDOWURXEOHVKRRWLQJ
x N(OHFWULFDOIDXOWFRPSUHVVRU
x O+67VWDUWUHOD\VWDUWFDSDFLWRU
x P6HQVRUIRUWKHFRQWUROOHU
x Q&RQGHQVHU
x R)DQ

0DLQWHQDQFH
x D5XEEHUJDVNHWRIWKHOLG
x E/RFNVDQGKLQJHV
x F&RQGHQVDWRU
x G(YDSRUDWRU
x H0DQXDOGHIURVW
x I1RLVH
x J%DWWHU\EDFNXS

 :LULQJGLDJUDPVDQGVDIHW\GDWDVKHHW
x D:LULQJGLDJUDP8/7)
x E6SDUHSDUWVOLVW8/7)
x F&RPSUHVVRUGDWD
x G6DIHW\GDWDVKHHW(3
x H&RQWUROOHU*
x I'HIDXOWVHWWLQJV


:RUNLQJVDIHW\
7KLVSDJHSURYLGHVJHQHUDOVDIHW\LQIRUPDWLRQIRUVHUYLFLQJWKHIUHH]HU
7KHLQVWUXFWLRQPDQXDOLQFOXGHVDGGLWLRQDOLQIRUPDWLRQDERXWVHFXULW\DQGFOHDQLQJRIIUHH]HU

*HQHUDOVDIHW\
7RSUHYHQWSHUVRQDODQGHTXLSPHQWGDPDJHWKHHOHFWULFDOVDIHW\OHJLVODWLRQRI\RXUFRXQWU\PXVW
EHREVHUYHG

x 1HYHUH[SRVHWKHPRYLQJSDUWVRIWKHSODQWWRSK\VLFDORYHUORDG

x :KHQUHSDLULQJSODQWSDUWVVDIHW\FRQFHUQVPXVWEHUHVSHFWHG

x :KHQXVLQJWRROVVSDUHSDUWVDQGHTXLSPHQWWKHH[LVWLQJVHFXULW\FRQFHUQVPXVWEH
PHW

x 0DLQWHQDQFHSURFHGXUHVGHVFULEHGLQWKLVPDQXDOPXVWRQO\EHSHUIRUPHGE\WUDLQHG
SHUVRQQHO

(OHFWULFDOVDIHW\
0DLQWHQDQFHSURFHGXUHVPD\LPSO\DYROWDJHKD]DUG)ROORZH[LVWLQJVDIHW\LQVWUXFWLRQVLQFOXGLQJ
WKHORZYROWDJHDQGFXUUHQW(8GLUHFWLYHVDQGRWKHUGHUHFWLYHVRI\RXUFRXQWU\
$OZD\VGLVFRQQHFWWKHSRZHUWRWKHXQLWEHIRUHUHSDLURUSDUWVUHSODFHPHQWLVLQLWLDWHG
8VHRQO\HOHFWULFDOHTXLSPHQWZKLFKLVGHVLJQHGIRUWKHIUHH]HU

&KHPLFDODQGELRORJLFDOVDIHW\
x $OZD\VREVHUYHWKHUHTXLUHPHQWVIRUVDIHKDQGOLQJDVGHVFULEHGEHORZ

x 5HDGWKHLQVWUXFWLRQPDQXDOEHIRUHXVLQJFOHDQLQJDQGVHUYLFLQJWKHIUHH]HU

x :HDUH\HSURWHFWLRQDQGJORYHVZKHQZRUNLQJZLWKUHIULJHUDQWV

x 6NLQFRQWDFWZLWKOLTXLGUHIULJHUDQWVPD\FDXVHIURVWELWH

x *RRGYHQWLODWLRQDQGDLUH[WUDFWLRQDWWKHZRUNDUHDLVUHTXLUHG

x 6WD\LQHQYLURQPHQWVZLWKKLJKFRQFHQWUDWLRQVRIUHIULJHUDQWYDSRUVLVKDUPIXO

x /RZFRQFHQWUDWLRQVPD\FDXVHQDUFRWLFHIIHFWV

x 6\PSWRPVRIWKLVPD\LQFOXGHKHDGDFKHVKRUWQHVVRIEUHDWKQDXVHDDQGGLIIFXOWLHVLQ
FRQFHQWUDWLRQ3RVVLEO\0RELOLW\FRQVFLRXVQHVV

x 5HDGWKHVDIHW\GDWDVKHHWVHFWLRQH


2. Information about the freezer
2a. General information about the freezer

ULTF 80
Backside

Hinge
Porthole

Controller
G-214

Sublid
Motor compartment Condenser
Feet

Door handle with lock

ULTF
L 220 / 320 / 420
Door handle with lock Backside Porthole

Condenser

Motor compartment
Castors Controller G-214

Sublids

4
Label plate located on the device.

Model Voltage/Hz Temp.range Refrigerant/Filling Serial no.

When contacting the supplier it is important to inform the model and serial number.
The label plate is located behind the front panel in the engine compartment.
For technical problems: See troubleshooting schedule (3b).

2b. Controller G-214


The PCB controller board is located in the engine compartment behind
the front panel.
The display is mounted in the front panel.
Data controller: Display G-214
72 hour battery backup for alarms.
Microprocessor with digital display.
Temperature display and data acquisition during power failures.
Visual and audible alarm.
Adjustable high / low temperature / alarm.
Integrated data logger.
Automatic cycle of sensor failure.
Measurement of the ambient air temperature.
Direct download / upload from the USB memory stick.
Display of battery voltage and ambient temperature.
Integrated memory and data logger.
RS 485/232 Interface.
Contact for remote alarm.
Prepared for GSM alarm.

Alarm for: PCB board


High / low temp.
Voltage Fault
Sensor error
Instrument error
Front door
Datasheet for controller G-214.
See section 5e.

5
2c. Model information
Model ULTF 80 ULTF 220 ULTF 320 ULTF 420
Item code DAI 0200 DAI 0213 DAI 0205 DAI 0213
Temp. range °C -40/-86 -40/-86 -40/-86 -40/-86
Max. ambient temp. °C 25 20 20 25
Power supply (V) 230/115*
Frequency (Hz) 50/60
Fuse (A) 10
AMP (A) 3 4 4 4
Power consumption
(KWh/24h) 3,83 7,4 8,79 10,5

Power (KW/Hp) 0.660/0.9 *) 0.880/1.2 0.880/1.2


No. of compressors 1
Refigerant/filling (gram) EP 88 / see label plate

* Special unit - not standard

*) Power consumption is monitored over time for each element. Pt. no values.

3. Troubleshooting / Repair
3a. General operating problems

Malfunction of the device, which can arise from improper handling of the device:

Moving or long periods of inactivity of the unit:

When moving or after long periods of inactivity, you must wait 1-2 hours before the freezer is
started.

Loading the freezer

When loading large quantities of items into the freezer, the temperature will rise temporarily.

Repeated lid openings

In case of repeated lid openings, leaks or faulty gaskets, the humidity will cause rime and possibi-
lity of ice formation inside the device and around the lid / sublids.

Component failure occurred during operation

Use the troubleshooting table section 3b.

6
E7URXEOHVKRRWLQJVFKHGXOH
Problem Cause Recommended Troubleshoong Acon
equipment
The socket or New fuse / plug.
fuse is defect.
Check the instal-
laon.
Repair errors. Con-
The unit does not Universal sider using wiring
Power cable is defect. Check power diagram secon 5
freeze and the instrument
cables
compressor does The controller is defect. test Lamp Change controller
and wiring in the
not start.
engine compart-
ment.
The sensor is defect. Test sensor. See secon 3n
Faulty windings in Test compressor See secon 3k
compressor. windings.
Start relay defect. Test start relay. See secon 3m
Fault in electrical instal- Use wiring-dia- See secon 5
laon. gram.
Voltmeter Check voltage Find the cause.

Low voltage
Defect or faulty start See secon 3m See secon 3m Change start relay/
relay/capacitor. capacitor

Defect compressor Ohmmeter Check for electrical Change the compr.


windings. failure in the com-
pressor. See secon 3f
Defect rotor (compres- Change the compr.
sor failure)
See secon 3f
The unit does not Tapping valve Open the system Remove 5cm of
freeze. The com- Manometer and rinse the sy- the capillary tube.
pressor tries to High pressure in the Filter stem with nitrogen. Change lter.
start, but fails. cooling system. See secon 3e

The unit has been The unit must rest


transported horizon- a few hours before
tally. start.
Ambient temp. low. Eksternal thermo- Check the temp. Find a beer place-
Compr.oil too cold. meter. ment.
May be general, if the Eksternal thermo- Check, that the Find a beer pla-
venlaon is not suf- meter. compressor not cement or venla-
cient. exceeds 70°C. on.

___________________ _______________ ________________ ______________

Ambient temp. high. Thermometer Check ambient Find a beer pla-


temp. cement or venla-
on.


E7URXEOHVKRRWLQJVFKHGXOH

Problem Cause Recommended Troubleshoong Acon


equipment
The compressor The sensor is in-
runs constantly. correctly installed.
Sensor is defect.
The unit freezes
normal or colder. Controller is dama-
ged.
Icing on the frame. Check the door for See secon 4a.
leaks.
The temperature is Check the sengs Set new values.
set too low. in the controller.
See secon 5f.

The compressor Too high voltage. Voltmeter Meassure the vol- Inform.
starts normally, tage.
but stops again. Too high ambient external thermometer Check the tempe- Beer placement
temperature. rature and venla- or venlaon.
on.
The unit cools too Leakage in the sy- Electronic leak-seeking, First check the solder See secon 3.
much, too lile or stem. soapy water, leak se- points, comp,
not at all. eking spray. capacitor, etc.
The fan is not run- Voltmeter Check for errors. Replace the fan.
The compressor
ning.
may run con- See secon 3p.
nuously.
The evaporator is
blocked by ice.
The unit cools too Lile or no com- service valve Mount the valve Change compres-
much or not at all. pressor and check pressure. sor.
capacity. Manometer
Compressor run- See secon 3f.
ning constant.
Insucient The device has Inform the user.
cooling. recently been l-
led up with a large
amount of heat.
In addion, tem- external thermometer Check temperature. Find beer venla-
perature of the air on or placement.
is too high.
In addion, the air external thermometer Check temperature. Find beer venla-
temperature is too on or placement.
low.


Examples of troubleshooting with a manometer connected to the process piping of the cooling sy-
stem. The system is blocked:
Suction pressure is very low.
Pressure equalization takes place very slowly or not at all.
Reason: Icing or dirt in the capillary tube or lter, or blockings in the system due to other reasons.

Reason: No compressor capacity


The suction pressure is too high.
The suction pressure does not change noticeably when the compressor stops.
This can be tested with a volumetric meter.

Leakage in the system


The pressure gauge indicating insufcient suction pressure.
On the pressure side the temperature increases.
Pressure equalization time is short.
Countervailing pressure is lower than expected.
Be sure that the pressure is sufcient for a pressure test.

9
F2SHQLQJRIWKHFRROLQJV\VWHP
x 7RSUHYHQWPRLVWXUHIURPSHQHWUDWLQJXQGHUUHSDLUWKHV\VWHPPXVWQRWEHRSHQIRUPRUH
WKDQPLQXWHV
x 3UHSDUHVSDUHSDUWVFRPSRQHQWVEHIRUHWKHV\VWHPLVRSHQHG
x 7KHQHZFRQQHFWRULVVROGHUHGWRDWXEHZLWKYDOYH

x 9HULI\WKDWWKHQHZILOWHUSDFNDJLQJLVLQWDFWDQGWKDWWKHILOWHULVQRWGDPDJHG
x ,IWKHSDFNDJLQJKDVEHHQEURNHQIRUDORQJHUSHULRGWKHILOWHUZLOOEHHPRLVW

G(YDFXDWLRQRIWKHUHIULJHUDQW
x ,WLVUHFRPPHQGHGWKDWWKHFRPSUHVVRULVUXQQLQJDWOHDVWPLQEHIRUHUHIULJHUDQWHYD
FXDWLRQLVXQGHUWDNHQ7KLVHQVXUHVWKDWWKHV\VWHPLVKRWVRWKDWWKHUHIULJHUDQWHDVLHUFDQ
EHSXOOHGRXWRIWKHFRPSUHVVRURLO
x $GULOOLQJWRQJVZLWKYDOYHLVSODFHGRQWKHSURFHVVSLSH
x 7KHUHIULJHUDQWLVHYDFXDWHG

x ,QVWDOODYDOYHRQWKHSUHVVXUHWXEHDQGSURFHVVSLSH


3URFHVVSLSHDQGSUHVVXUH
WXEHILWWHGZLWKDYDOYH

x 7KHFRROLQJV\VWHPLVHYDFXDWHGZLWKDWZRVWDJHYDFXXPSXPSIRUDWOHDVWPLQXWHV
%RWKIURPWKHSUHVVXUHSLSLQJDQGSURFHVVSLSLQJ
x %ORZWKHV\VWHPZLWKQLWURJHQERWKIURPWKHVXFWLRQDQGWKHSUHVVXUHVLGH

H&KDQJLQJWKHGU\ILOWHU
x 7KHGU\ILOWHUPXVWSLFNXSPRLVWXUHLQWKHV\VWHPGXULQJRSHUDWLRQDQGIXQFWLRQDVWKHFD
SLOODU\WXEHLQIURQWRIWKHFDSLODU\WXEHLQRUGHUWRDYRLGFORJJLQJ&ORJJHGILOWHURUFDSLOODU\
WXEHFDXVHVDSUHVVXUHGURSE\WKLVWKHILOWHUEHFRPHVFROGHUDQGLFHZLOOEORFNWKHV\VWHP
7KHFRPSUHVVRULVRYHUORDGHGZLWKDSRVVLELOLW\RIFUDVK
x 7KHGU\ILOWHULVSODFHGDIWHUWKHFRQGHQVHURXWOHWLPPHGLDWHO\EHIRUHWKHFDSLOODU\$Q\
RSHQLQJRIWKHFRROLQJV\VWHPGU\ILOWHUFKDQJHWRHQVXUHWKHIXQFWLRQDQGOLIHWLPHRIWKH
IUHH]HU
x ,WLVWKHUHIRUHUHFRPPHQGHGDOZD\VWRRUGHUDQHZILOWHUGULHUDORQJZLWKDQHZVHUYLFHF\
OLQGHUZLWKFRROLQJDJHQW
x 7RSUHYHQWPRLVWXUHIURPSHQHWUDWLQJGXULQJWKHUHSDLUWKHGU\LQJILOWHUPXVWQRWEHRSHQ
IRUPRUHWKDQPLQXWHV
x $IWHUHYDFXDWLRQDQGEORZLQJZLWKQLWURJHQWKHWXEHVPXVWEHFOHDQHGRQERWKVLGHVRIWKH
ILOWHUGULHUEHIRUHFXWWLQJ%\GRLQJWKLVWKHSLSHHQGVDUHIUHHIURPLPSXULWLHVDQGPHWDOSLH
FHVDQGUHDG\IRUVROGHULQJ
x &XWRIIWKHSUHVVXUHSLSHFORVHWRWKHILOWHUZLWKDSLSHFXWWHU

x &XWRIIWKHFDSLOODU\WXEHZLWKDFDSLOODU\WXEHVFLVVRUV
x ,WLVUHFRPPHQGHGWRXVHDVSHFLDOWRQJVWRFUHDWHDZDYHRQWKHFDSLOODU\WXEHZKLFKHQ
VXUHVWKHFRUUHFWSRVLWLRQLQJLQWKHILOWHU


A B

Right Wrong

,QWKHILJXUH$WKHFDSLOODU\WXEHLVFRUUHFWO\LQVWDOOHGLQDGU\ILOWHU,QRUGHUWRHQVXUHHIIFLHQW
XVHRIWKHILOWHULWPXVWEHSRVLWLRQHGZLWKDQLQFOLQDWLRQRIDWOHDVWDQGWKHFDSLOODU\WXEH
PXVWEHXQGHUQHDWK

,QWKHILJXUH%WKHFDSLOODU\WXEHLVWRRFORVHWRRWKHZHERIWKHILOWHU,WSURYLGHVJUHDWUHVLVWDQ
FHDQGILOWHUEORFNLQJDIWHUDVKRUWWLPH2UWRRIDUDZD\VRLWZLOOEHILOOHGZLWKIOX[RUVROGHU

x 6ROGHUWKHQHZILOWHU
x &OHDQWKHVROGHUSRLQWVZLWKDZLUHEUXVK

x )OXVKWKHV\VWHPZLWKQLWURJHQ

x ,IRQO\WKHGU\ILOWHULVWREHUHSODFHGWKHV\VWHPPXVWEHSUHVVXUHWHVWHG6HHVHFWLRQJ


I&KDQJLQJWKHFRPSUHVVRU
x (YDFXDWHWKHUHIULJHUDQWRIWKHV\VWHP6HHVHFWLRQG
x $OOWXEHVDUHFXWZLWKDSLSHFXWWHU'R127VROGHURI
x :KHQUHSODFLQJWKHFRPSUHVVRUWKHGU\ILOWHUPXVWDOVREHUHSODFHG6HHVHFWLRQH
x 7KHVXFWLRQDQGSUHVVXUHSLSHVRIWKHFRPSUHVVRUPXVWEHFOHDQHGDQGFXWZLWKDSLSHFXW
WHUMXVWDERYHWKHVROGHULQJSLSH
x 'HPRXQWWKHFRPSUHVVRU
x ,QVWDOOWKHQHZFRPSUHVVRUZKLFKLVSUHSDUHGDVGHVFULEHGEHIRUH F

x ,QRUGHUWRDYRLGGHFRPSRVLWLRQRIUHIULJHUDQWVZKLFKPD\UHPDLQLQWKHV\VWHPGXULQJWKH
VROGHULQJRSHUDWLRQWKHV\VWHPLVEORZQZLWKGU\QLWURJHQUHVSHFWLYHO\IURPWKHVXFWLRQ
VLGHUHVSHFWLYHO\SUHVVXUHVLGH
x 6ROGHUWKHWXEHVRQWRWKHFRPSUHVVRU
x 3UHVVXUHWHVWWKHV\VWHP

J3UHVVXUHWHVWLQJDQGOHDNGHWHFWLRQ
x 3UHVVXUHWHVWWKHV\VWHPZLWKQLWURJHQ7KHSUHVVXUHPXVWEHEDUGXULQJDSHULRGRI
KRXUV
x &KHFNWKHVROGHUSRLQWVZLWKVRDS\ZDWHURUOHDNGHWHFWLRQVSUD\
x ,QFDVHRIDQ\OHDNVHPSW\WKHV\VWHPIRUQLWURJHQ
x 5HSDLUDQGSUHVVXUHWHVWDJDLQ
x 'XULQJRSHUDWLRQOHDNGHWHFWLRQPXVWEHSHUIRUPHGRQWKHSUHVVXUHVLGHZLWKWKHFRPSUHV
VRUUXQQLQJ7KHVXFWLRQVLGHPXVWEHWHVWHGZKLOHWKHFRPSUHVVRULVVWRSSHGDQGWKH
SUHVVXUHVDUHHTXDOL]HG
x 7KHQLWURJHQPXVWVORZO\EHHPSWLHGIURPWKHV\VWHP


K9DFXXPVXFWLRQ9DFXXPFKHFN
$YDFXXPLVPDGHRQWZRORFDWLRQVRQWKHV\VWHPRQHRQWKHSURFHVVWXEHDQGRQHRQWKHSLSHEUDQFK
XVHGIRUWHVWLQJORFDWHGRQWKHSUHVVXUHWXEHZLWKDQH[SORVLRQSURRIVWDJHYDFXXPSXPS

x 7KHSUHVVXUHVKRXOGEHP%DURUORZHUIRUDWOHDVWKRXUV
x 7KHV\VWHPLVQRZUHDG\IRUWKHILOOLQJRIWKHUHIULJHUDQW

L5HIULJHUDQWILOOLQJZLWK(3
%HIRUHILOOLQJWKHUHIULJHUDQWDYDFXXPPXVWEHVXFKHG6HHVHFWLRQK
1RWHWKDW(3LVWREHVXSSOLHGIURPDERWWOHFRQWDLQLQJDVSHFLILFDPRXQWRIUHIULJHUDQW
&RPPRQSURFHGXUHVIRURWKHUUHIULJHUDQWVFDQQRWEHXVHG
)XUWKHULWLVLPSRUWDQWWKDWWKHHQWLUHFRQWHQWVRIWKHERWWOHLVLQWURGXFHGLQWRV\VWHPWRHQVXUHRSWLPDOSHUIRU
PDQFH
7KHFRQWHQWVRIWKHERWWOHPXVWEHPL[HGEHIRUHXVHE\VKDNLQJWKHERWWOHIRUDWOHDVWPLQXWHEHIRUHWKH
ILOOLQJ
,QRUGHUWRSHUIRUPWKHILOOLQJRSHUDWLRQSURSHUO\LWLVQHFHVVDU\WRXVHDFDSLOODU\WXEHZLWKWKHYDOYHEHIRUH
WKHILOOLQJVLWHLQVWHDGRIDFRQYHQWLRQDOIHHGLQJWXEH7KHUHDVRQLVWKDWWKHFDSLOODU\WXEHHQVXUHVWKDWWKH
HQWLUHTXDQWLW\RIUHIULJHUDQWLVLQWURGXFHGWRWKHV\VWHP,IDQRUGLQDU\ILOOHUKRVHLVXVHGLWPXVWEHDVVKRUW
DVSRVVLEOH

:$51,1*(3LVIODPPDEOH
7KHUHIULJHUDQWF\OLQGHULVZHLJKHGEHIRUHXVH
7KHF\OLQGHUPXVWEHVKDNHQIRUPLQEHIRUHXVH
'XULQJWKHILOOLQJSURFHGXUHWKHF\OLQGHUPXVWEHXSVLGHGRZQ


&\OLQGHUZLWKPDQRPHWHU 9DFXXPVXFWLRQRIWKHILOOLQJKRVH

/RDGLQJSURFHGXUH
0DNHYDFFXP6HHVHFWLRQK
7KHF\OLQGHUZLWKPDQRPHWHULVFRQQHFWHGWRWKHFRXSOHURIWKHSURFHVVSLSLQJ
5HPHPEHUWRILUVWPDGHYDFXXPLQWKHILOOLQJKRVHWRHPSW\LW
)LOOWKHUHIULJHUDQWLQWRWKHV\VWHPXQWLOWKHSUHVVXUHJDXJHRQWKHSUHVVXUHWXEHVKRZVDSSUR[EDU
6WDUWWKHFRPSUHVVRUDQGOHWLWUXQIRUPLQ2SHQWRWKHF\OLQGHUDJDLQWRJHWRXWWKHUHPDLQLQJUHIULJHUDQW
:KHQWKHSUHVVXUHLQWKHERWWOHVKRZVEDUWKHERWWOHLVHPSW\
,WLVLPSRUWDQWWKDWWKHYDOYHLVFORVHGLPPHGLDWHO\LQRUGHUWRDYRLGWKDWWKHUHIULJHUDQWUXQVEDFNLQWRWKHF\OLQGHU
1RZWKHFRROLQJV\VWHPLVILOOHGZLWKUHIULJHUDQWDQGRQO\QHHGVWREHFORVHG
'LVFRQQHFWWKHILOOLQJKRVHZLWKSUHVVXUHJDXJHIURPWKHSURFHVVSLSLQJ
3XVKWKHSURFHVVSLSLQJDQGSUHVVXUHSLSHVWRJHWKHUZLWKDVSHFLDOWRQJV
&XWRIIYDOYHZLWKDSLSHFXWWHU

&ORVLQJWKHSURFHVVWXEHRQV\VWHPVZLWKIODPPDEOHUHIULJHUDQWVPXVWEHSHUIRUPHGE\SURIHVVLRQDOVZLWKD/RN
5LQJHQGVOHHYH,WLVUHFRPPHQGHG127WRVROGHUV\VWHP
&OHDQWKHSLSHZLWKVWHHOZRRORUHPHU\FORWK8VHURWDWLRQDOPRYHPHQWLQRUGHUWRDYRLGVFUDWFKLQJWKHOHQJWKRI
WKHWXEH
$SSO\/RN3UHEWRWKHHQGRIWKHWXEH
7XUQWKHHQGVOHHYHƒVRWKDWWKH/RN3UHELVSODFHGDURXQGWKHWXEH
6TXHH]HWKHHQGVOHHYHWRJHWKHUZLWKWKHVSHFLDOWRRODVVKRZQLQWKHLOOXVWUDWLRQ
6WDUWWKHIUHH]HUDQGFRQWUROWKHIXQFWLRQRIWKHXQLW


M(OHFWULFDOWURXEOHVKRRWLQJ

%HIRUHVWDUWLQJV\VWHPDWLFWURXEOHVKRRWLQJFKHFNWKHIROORZLQJ
x 3URSHUYROWDJHLVSUHVHQW
x (OHFWULFDOHTXLSPHQWXVHGLVVXLWDEOHIRUWKHFRPSUHVVRU
x 7KHZLUHVDUHSURSHUO\LQVWDOOHGDFFRUGLQJWRZLULQJGLDJUDP
x 7KHUHLVQRWUDQVLWLRQEHWZHHQWKHOLYHSDUWVDQGJURXQG

&RQWURORIWKHWUDQVLWLRQWRJURXQG

,QRUGHUWRFKHFNZKHWKHUWKHUHLVDWUDQVLWLRQEHWZHHQWKHFRQGXFWLQJFRPSRQHQWVDQGWKHFKDV
VLVWKHLQVXODWLRQUHVLVWDQFHLVWHVWHGE\XVLQJDQRKPPHWHURUWKHVHFRQGKLJKYROWDJHHTXLS
PHQW$QRKPPHWHUFDQEHXVHGIRUDURXJKFKHFN$WWKH2KPPHWHURQHFODPSLVSODFHGRQWKH
FRPSUHVVRU¶VJURXQGWHUPLQDO7KHVHFRQGFODPSRQWKHFRPSUHVVRUVKDUHGOHJ VHHVNHWFK 
6KRZLQJRKPPHWHUDWUDQVLWLRQWKHFRPSUHVVRULVUHSODFHG

3OXJRQWKHFRPSUHVVRU

6KDUHGOHJ*URXQGWHUPLQDO

8VHVKLJKYROWDJHWHVWV\VWHPVZLWKIODPPDEOHUHIULJHUDQWVHQVXUHWKDWWKHV\VWHPLVFRPSOHWHO\
GUDLQHGRIFRRODQWDVWKLVFDQFDXVHVSDUNVGXULQJWKHWHVW


N(OHFWULFDOIDXOWFRPSUHVVRU

5HPRYHWKHVWDUWUHOD\IURPWKHFRPSUHVVRUDQGXVHDQRKPPHWHUWRWHVWWKHFRPSUHVVRUKHDG
DQGVWDUWUHFRYHU\&RQQHFWRKPPHWHUEHWZHHQWKHFRPPRQFRQQHFWRUDQGVWDUWZLQGLQJWKHQWKH
ZLQGLQJLVWRGHEXJ6HHWKHSLFWXUHEHORZ

'LPHQVLRQVRIWKHFRPSUHVVRUFRQQHFWLRQVWRGHWHUPLQHZKHWKHUGULYLQJDQGVWDUWZLQGLQJDUHLQWDFW

7KLVLVGRQHE\PHDVXULQJWKHUHVLVWDQFHRIWKHVH&DUU\RXWWKUHHUHVLVWDQFHPHDVXUHPHQWVRQ
FRPSUHVVRUSHQHWUDWLRQV7KHVXPRIWKHWZRVPDOOHVWPHDVXUHPHQWVWKHLQWDFWZLQGLQJVZLOOEH
HTXDOWRWKHKLJKHVW)LQGLIWKHFXUUHQWYDOXHVRIWKHFRPSUHVVRUGDWDVKHHW

%\PHDVXULQJWKHFRPSUHVVRUVZLWKEXLOWZLQGLQJSURWHFWRULW
LVH[WUHPHO\LPSRUWDQWWRPHDVXUHEHWZHHQ.DQG6DVWKLV
PHDVXUHZLOOWHOOLIWKLVLVEXUQWZLQGLQJVRUDQRSHQZLQGLQJ
SURWHFWRU

:LQGLQJ 6LQFHLWLVUHODWLYHO\VPDOOYDOXHWREHPHDVXUHGLWZRXOGEH
SURWHFWRU
DJUHDWDGYDQWDJHWRXVHDGLJLWDORKPPHWHU

2KPPHDVXUHPHQW

,QGLFDWHVWKHPHDVXUHPHQWHUURUWKHFRPSUHVVRULVUHSODFHG


3m. HST-start relay, start capacitor

Connect a voltmeter between terminals 10 and 13 at the start of the relay. If no voltage is present,
there is either a faulty cable or also start relay is defective.

Connect a voltmeter between terminals 10 and 14. If no voltage is present, the temperature sensor
or its cable is defective.

18
$UHOD\FDQEHFKHFNHGZLWKDQLQGLFDWRUOLJKWDV
VKRZQLQWKHVNHWFKPDLQWDLQHQG7KHUHOD\LVXVX
DOO\RNZKHQLQVWDQGLQJSRVLWLRQLVQRWOLWDQGZKHQ
LWLVOLWZKHQWKHUHOD\LVXSVLGHGRZQ

7KHVWDUWFDSDFLWRUFDQEHFKHFNHGE\LQMHFWLQJWKH
QRUPDOYROWDJHIRUDIHZVHFRQGVDQGWKDQVKRUWLQJ
LW:KHQVSDUNVDUHJHQHUDWHGWKHFDSDFLWRULVLQ
RUGHU

:KHQUHSODFLQJWKHFRPSUHVVRUVKRXOGVWDUWUHOD\DQGVWDUWFDSDFLWRUDOVRUHSODFHG
6WDUWUHOD\LVSODFHGRQWKHFRPSUHVVRU¶VWKUHHWHUPLQDOOHJVDQGFODPSHG
7KHYROWDJHLVFRQQHFWHGWRWHUPLQDOVDQG
7KHVWDUWFDSDFLWRULVFRQQHFWHGWRWHUPLQDOVDQGDQGFODPSHG

E&RYHU H7KHFRPSUHVVRUEODGHV F6WDUWFDSDFLWRU

G:LUHKDQJHU D6WDUWUHOD\


3n. Sensor for the controller
PT 1000

A faulty sensor will typically prevent the compressor from starting.

If the sensor is covered with ice, the compressor will run more than usual and cool too much.

The easiest way to check the function of the sensor, is to place your hand around the sensor. If the
temperature recorded on the display in the front panel does not rise, the sensor is faulty and needs to
be replaced.

The sensor can also be tested with an ohmmeter.

The PT 1000 sensor for ULTF 80 is located behind an alu. panel at the bottom of the freezer.

Remove the alu. panel.


Remove the sealing material around introduction and pull out the sensor.
Disconnect the electrical connection of the sensor in the CBS-modul.
Mount the new sensor in reverse order.
Remember! The sensor must be replaced with a sensor with the same characteristics as the original.

Sensor ULTF80 Alu. panel

The PT 1000 sensor for ULTF220 /320 and 420 is located in the stage on the right side of the freezer.

Remove the alu. panel.


Remove the sealing material around introduction and pull out the sensor.
Disconnect the electrical connection of the sensor in the CBS-modul.
Mount the new sensor in reverse order.
Remember! The sensor must be replaced with a sensor with the same characteristics as the original.

Sensor ULTF220 / 320 / 420 Alu. panel

20
n&RQGHQVHU
6HHVHFWLRQF

m)DQ
,IWKHYHQWLODWRUVWRSVLWFDQFDXVHLQVXIILFLHQWFRROLQJRIFRQGHQVHUDQGFRPSUHVVRUV
(OHFWULFDOO\WKHIDQLVFRQQHFWHGWRWHUPLQDODQGRQWKHVWDUWUHOD\
3K\VLFDOO\WKHIDQLVSODFHGLQWKHPRWRUFRPSDUWPHQWFORVHWRWKHFRPSUHVVRUDQGIL[HGRQWKH
SDQHOZLWKEROWV

)DQ 3DQHO


0DLQWHQDQFH
D5XEEHUJDVNHWRIWKHOLG
5XEWKHJDVNHWZLWKDVXLWDEOHSURGXFWVRWKDWLWVWD\VIOH[LEOHDQGWKHRSWLPDOIXQFWLRQDQGWLJKW
QHVVLVVHFXUHG
0DNHVXUHWKHOLGFORVHVWLJKWO\VRWKDWQRLFHIRUPVDURXQGWKHOLGIUDPH
x 2SHQWKHOLGDQGSODFHDSLHFHRISDSHU&ORVHWKHOLG
x 3XOOWKHSDSHU
x ,IWKHSDSHUFDQQRWEHSXVKHGEDFNWKHDGMXVWPHQWLV2.
x 7KHWHVWLVPDGHDWERWKWKHOHIWDQGULJKWVLGH

E/RFNVDQGKLQJHV
0DNHVXUHWKHORFNZRUNVHDVLO\DQGVDIHO\,IQHVHVVDU\XVHDOXEULFDQWIRUORFNV
0DNHVXUHWKHKLQJHVDUHQRWORRVH

F&RQGHQVHU
7KHFRQGHQVHULVSODFHGRQWKHEDFNRIWKHIUHH]HUDQGIL[HGZLWKVFUHZV
7KHIUHH]HUVKRXOGEHSODFHGZLWKDWOHDVWFPIUHHWRWKHVLGHVDQGFPIUHHDWWKHEDFN
,WLVLPSRUWDQWWKDWWKHFRROLQJULEVDUHNHSWFOHDQDQGWKHDPELHQWWHPSHUDWXUHGRHVQRWH[HHG
ƒ& 8/7) ƒ& 8/7) 
,WPD\EHQHFHVVDU\WRFKDQJHWKHUXEEHUSDFNLQJRQWKHFRQGHQVHUFRUQHUVDOVRPD\EHGDPSHQ
WKHORQJLQOHWWXEHZLWKDUXEEHUVWUDS


G(YDSRUDWRU
7KHIUHH]HUWKHOLGIUDPHDQGWKHVHQVRUPXVWEHFKHFNHGIRULFH
,QFDVHRIODUJHLFHIRUPDWLRQWKHIUHH]HUPXVWEHGHIURVWHG

H0DQXDOGHIURVW
x 5HPRYHWKHFRQWHQWVRIWKHIUHH]HU

x 8QSOXJWKHXQLW

x 3ODFHDWUD\XQGHUWKHIUHH]HUDQGUHPRYHWKHSOXJDWWKHERWWRPRIWKHIUHH]HU

x /HDYHWKHOLGRSHQXQWLOWKHLFHFDQEHUHPRYHG

x :LSHWKHLQWHULRUFDELQHWZLWKDFORWKXQWLOLWLVGU\

:KHQWKHLQWHULRUFDELQHWLVGU\FORWKWKHSOXJDQGUHVWDUWWKHIUHH]HU

3OXJIRUGHIURVWZDWHU

I1RLVH
7KHIROORZLQJPXVWEHFKHFNHGLQFDVHRIQRLVH
x 7KHFRPSUHVVRULVQRWWLJKWHQHGZHOO
x 7KHUXEEHUIHHWDUHGHIHFWRUWRRKDUG
x 7KHFRPSUHVVRUSURFHVVWXEHLVWRRORQJ
x 7KHIDQEODGHVDUHGDPDJHGRUGLUW\
x 7KHIDQLVQRWWLJKWHQHGZHOO
x 7KHIDQEXVKLQJVDUHZRUQ
x 7KHIUHH]HULVQRWSRVLWLRQHGRQDIODWVXUIDFH

3URFHVVWXEH WRRIDU

5XEEHUIHHW


x /RQJSLSHVFDQFDXVHUHVRQDQFHYLEUDWLRQV$UXEEHUVWUDSFDQDVVLVW6HHLOOXVWUDWLRQ

J%DWWHU\EDFNXS
7KHEDWWHU\ 9$K LVORFDWHGLQWKHHQJLQHFRPSDUWPHQW
,WKDVDOLIHVSDQRI\HDUVEXWVKRXOGEHFKHFNHGHYHU\VL[PRQWKV
&KHFNWKHYROWDJHZLWKDYROWPHWHU

%DFNXSEDWWHU\


RD
WH
BK

RD

BK
USB + -
+12 VDC

- + - + - +
Heater

Heater

RS +

Power
RS -

Battery
0V
Valve

Supply
Door

Light

BATTERY
12 V 12 V
Alarm
MG214
temperatur sensors
Door Sensor

Evaporat.
Compr. 1

Compr. 2
Compr. 1
Compr. 2

Chamber
+12 VDC
Defrost

NTC 1
NTC 2
Heater

0V
Fan

230V AC
L
PG214 SG214 N
BN BN WH WH RD WH BU WH
BN BN BU
LI RD

25
Controller box
5a. Wiring diagram ULTF 80

BK OLP C
COMPRESSOR
black red natur S R
relais
1 2 BU
BU BN BK GR BK BU BN BU
BN
Starting capacitor
BN
BU V fan
YG
door switch sensor 2 sensor 1 1
external alarm optional
N L YG
BK
E - Farvekode Colour Code Farbkode
GR Earth screw in BN Brun Brown Braun
compressor compartment
terminal board BU Blå Blue Blau
BK Sort Black Schwarz
LI Lilla Lilac Lila
YG Gul / grøn Yellow / green Gelb / grün
power cord WH Hvid White Weiss
RD Rød Red Rot
GR Grå Gray Grau
5a. Wiring diagram ULTF 220
BU
BN
BK
BK RD

USB - + - + - +

+12 VDC
Heater

Heater

RS +
Power

Battery
RS -
0V
Valve

Supply
Door

Light 12V 12V


Alarm
230V AC

MG214 SG214 L N

temperatur sensors

PG214
+12 VDC
Door Sensor

Evaporat.
Compr. 1
Compr. 2
Compr. 2

Chamber
Compr. 1
Defrost

NTC 2

NTC 1
BN BU
Heater

BN

0V
Fan

GR BK BN

GR BN
BK BU YG

BU BN WH RD BU BN Controller box

black red natur

BU BN BK BK BU
GR BN YG

door switch sensor 2 sensor 1


optional

COMPRESSOR
C
+ RD
external alarm BATTERY BK
S R
-

OLP relais
1 2

BK BN BU
Starting capacitor BU

BN
BU V
1
BU BN YG
YG fan
BK N L YG
E
Earth screw in
GR compressor compartment

terminal board

BU BN YG

power cord

Farvekode Colour Code Farb kode

BN Brun Brown Braun


BU Blå Blue Blau
BK Sort Black Schwarz
GR Grå Grey Grau
YG Gul / grøn Yellow / green Gelb / grün
WH Hvid White Weiss
RD Rød Red Rot

26
5a. Wiring diagram ULTF 320 / 420
BU
BN
BK
BK RD

USB - + - + - +

+12 VDC
Heater

Heater

RS +
Power

Battery
RS -
0V
Valve

Supply
Door

Light 12V 12V


Alarm
230V AC

MG214 SG214 L N

temperatur sensors

PG214
+12 VDC
Door Sensor

Evaporat.
Compr. 1
Compr. 2
Compr. 2

Chamber
Compr. 1
Defrost

NTC 2

NTC 1
BN BU
Heater

BN

0V
Fan

GR BK BN

GR BN
BK BU YG

BU BN WH RD BU BN
Controller box

black red natur

BU BN BK door switch sensor 2 sensor 1


GR BN YG
BK BU optional

overload protector compressor NEK2160U

BK 3 1
C

YG

5 2
S R
BN
BN BU BN BU
external alarm
4 4 1
BU BU

RD BK YG BU BK
+ -
BATTERY

BN
BU
V
YG

E L N 1 2 VENTILATOR

YG BN BN BU BU GR BK

YG
Power cord BN
BU

Farvekode Colour Code Farb kode

BN Brun Brown Braun


BU Blå Blue Blau
BK Sort Black Schwarz
GR Grå Grey Grau
YG Gul / grøn Yellow / green Gelb / grün
WH Hvid White Weiss
RD Rød Red Rot

27
5b. Spare parts list ULTF 80
5144

5605
5606
5682

5054
5055

5054
5145 6553
4605

4607

5972 5871
4608

5714
5450 5870
5451 5129 5141
5128
5402

5716
5715
61

5683
5850 5684 4630

5002 5130

5538 126

863
87

28
5b. Spare parts list ULTF 80

Pos. no. Code no. Part Recommended


61 5079000-01 Filter dryer 20 gr. 1
87 5079007-01 Base plate fittings, set, complete
126 5070095-01 Compressor NEK2150U, complete 1
863 5070106-01 Cover
4605 5044001-01 Backup battery 1
4607 5041006-01 PCB-Board G-214 Controller 1
4608 5041007-01 Power supply G-214 1
4630 5043007-01 Display G-214 1
5002 5053017-01 Foot with pin
5054 5079008-01 Fittings for condenser
5055 5071017-01 Condenser
5128 5032011-01 Magnet
5129 5031164-01 Magnet bracket
5130 5030088-01 Display cover
5141 5031163-01 Sensor bracket
5144 5052003-01 Lid foamed without handle and hinges
5145 5052009-01 Sub lid ULTF80 1
5402 5031006-01 Hinge
5450 5030003-01 Cover top part for hinge
5451 5030004-01 Cover bottom part for hinge
5538 5070099-01 Terminal Board, complete
5605 5051001-01 Handle with lock
5606 5030000-01 Inlay for handle
5682 5051002-01 Key, set 2 pcs.
5683 5031004-01 Catch for handle
5684 5030001-01 Cover for catch
5714 5042019-01 Temp. sensor - lenght 800 mm 1
5715 5054003-01 Chassis plug
5716 5054002-01 Plug for remote alarm
5850 5070101-01 Starting device 1
5870 5010009-01 Wings for fan
5871 5010000-01 Fan complete 1
5972 5030006-01 Grill for motor compartment
6553 Mains lead
- Refrigerant 1
- 5072000-01 Cylinder deposit for refrigerant 1

29
5b. Spare parts list ULTF 220
5112

5605

5606
5682

5055
5054

5054
4607

5970
5408 4608
5871
5404 5971

5714 5870

5141
5129 5872
5716
5450 5128
5715
5451 5000
5401

4630
6553
5683
5684
5130

61
5850 4605

5005
5538
126
5004 863
87

30
5b. Spare parts list ULTF 220

Pos. no. Code no. Part Recommended


61 5079000-01 Filter dryer 20 gr. 1
87 5079007-01 Base plate fittings, set, complete
126 5070095-01 Compressor NEK2150U, complete 1
863 5070106-01 Cover
4605 5044001-01 Backup battery 1
4607 5041006-01 PCB-Board G-214 Controller 1
4608 5041007-01 Power supply G-214 1
4630 5043007-01 Display G-214 1
5000 5030040-01 Drain plug
5004 5053009-01 Double castor
5005 5032002-01 Fixed spanner, 9mm
5054 5079008-01 Fittings for condenser
5055 5071017-01 Condenser
5112 5052100-01 Lid foamed without handle and hinges
5128 5032011-01 Magnet
5129 5031164-01 Magnet bracket
5130 5030088-01 Display cover
5141 5031163-01 Sensor bracket
5402 5031006-01 Hinge
5404 5052008-01 Sub lid, small
5450 5030003-01 Cover top part for hinge
5451 5030004-01 Cover bottom part for hinge
5538 5070099-01 Terminal Board, complete
5605 5051001-01 Handle with lock
5606 5030000-01 Inlay for handle
5682 5051002-01 Key, set 2 pcs.
5683 5031004-01 Catch for handle
5684 5030001-01 Cover for catch
5714 5042018-01 Temp. sensor - lenght 400 mm 1
5715 5054003-01 Chassis plug
5716 5054002-01 Plug for remote alarm
5850 5070101-01 Starting device 1
5870 5010009-01 Wings for fan
5871 5010000-01 Fan complete 1
5872 5019052-01 Well-nut, screw, set for fan bracket
5970 5030006-01 Motor screen, white plastic
5971 5030005-01 Grill for motor compartment
6553 Mains lead
- Refrigerant 1
- 5072000-01 Cylinder deposit for refrigerant 1

31
5b. Spare parts list ULTF 320
5118

5605

5606
5682

5052

5053
5970

5052 4607

4608
5405 5871

5405 5971

5714 5716 5870


5405
5141 5715
5129
5450 5128 5872
5451 5000
5401

4630
6553
5683
5684

5130
5850 5851

4605
61 5820
5005

5004

126
87 5831
0069

32
5b. Spare parts list ULTF 320

Pos. no. Code no. Part Recommended


61 5079000-01 Filter dryer 20 gr. 1
69 5070103-01 Overload protector
87 5079007-01 Base plate fittings, set, complete
126 5070097-01 Compressor NEK2160U, complete 1
4605 5044001-01 Backup battery 1
4607 5041006-01 PCB-Board G-214 Controller 1
4608 5041007-01 Power supply G-214 1
4630 5043007-01 Display G-214 1
5000 5030040-01 Drain plug
5004 5053009-01 Double castor
5005 5032002-01 Fixed spanner, 9mm
5052 5079009-01 Fittings for condenser
5053 5071018-01 Condenser
5118 5052034-01 Lid foamed without handle and hinges
5128 5032011-01 Magnet
5129 5031164-01 Magnet bracket
5130 5030088-01 Display cover
5141 5031163-01 Sensor bracket
5401 5031006-01 Hinge 30
5405 5052007-01 Sub lid, large
5450 5030003-01 Top part for hinge cover
5451 5030004-01 Bottom part for hinge cover
5605 5051001-01 Handle with lock
5606 5030000-01 Inlay for handle, neutral
5682 5051002-01 Key, set - 2 pcs
5683 5031004-01 Catch for handle
5684 5030001-01 Cover for catch
5714 5042018-01 Temp. sensor - lenght 400 mm 1
5715 5054003-01 Chassis plug
5716 5054002-01 Plug for remote alarm
5820 5070107-01 Starting device 1
5831 5070104-01 Cover
5850 5070108-01 Starting capacitor 1
5851 5070109-01 Run capacitor 1
5870 5010009-01 Wings for fan
5871 5010000-01 Fan, complete
5872 5019052-01 Well-nut, screw, set for fan bracket
5970 5030006-01 Motor screen, White plastic
5971 5030005-01 Grill for motor compartment
6553 Mains lead
- Refrigerant 1
- 5072000-01 Cylinder deposit for refrigerant 1

33
5b. Spare parts list ULTF 420 5122

5605

5606
5682

5052

5053
5970

5052 4607
5404
4608 5871
5405

5405
5971
5870
5405 5714
5716
5129 5141 5715
5450 5128
5872
5451 5000

5402

4630
6553

5683
5684
5130

5850 5851

5005 61 4605
5820
5004

126
5831
87 0069

34
5b. Spare parts list ULTF 420
Pos. no. Code no. Part Recommended
61 5079000-01 Filter dryer 20 gr. 1
69 5070103-01 Overload protector
87 5079007-01 Base plate fittings, set, complete
126 5070097-01 Compressor NEK2160U, complete 1
4605 5044001-01 Backup battery 1
4607 5041006-01 PCB-Board G-214 Controller 1
4608 5041007-01 Power supply G-214 1
4630 5043007-01 Display G-214 1
5000 5030040-01 Drain plug
5004 5053009-01 Double castor
5005 5032002-01 Fixed spanner, 9mm
5052 5079009-01 Fittings for condenser
5053 5071018-01 Condenser
5122 5052004-01 Lid foamed without handle and hinges
5128 5032011-01 Magnet
5129 5031164-01 Magnet bracket
5130 5030088-01 Display cover
5141 5031163-01 Sensor bracket
5402 5031007-01 Hinge 40
5404 5052008-01 Sub lid, small
5405 5052007-01 Sub lid, large
5450 5030003-01 Top part for hinge cover
5451 5030004-01 Bottom part for hinge cover
5605 5051001-01 Handle with lock
5606 5030000-01 Inlay for handle, neutral
5682 5051002-01 Key, set - 2 pcs
568 3 5031004-01 Catch for handle
5684 5030001-01 Cover for catch
5714 5042018-01 Temp. sensor lenght - 400 mm 1
5715 5054003-01 Chassis plug
5716 5054002-01 Plug for remote alarm
5820 5070107-01 Starting device 1
5831 5070104-01 Cover
5850 5070108-01 Starting capacitor 1
5851 5070109-01 Run capacitor 1
5870 5010009-01 Wings for fan
5871 5010000-01 Fan, complete
5872 5019052-01 Well-nut, screw, set for fan bracket
5970 5030006-01 Motor screen, White plastic
5971 5030005-01 Grill for motor compartment
6553 Mains lead
- Refrigerant 1
- 5072000-01 Cylinder deposit for refrigerant 1

35
5c.

36
37
38
5c.

39
40
41
d6DIHW\GDWDVKHHWIRU(3
 ,'(17,),&$7,212)7+(68%67$1&(0,;785($1'2)7+(&203$1<81'(57$.,1*

3 URGXFWLGHQWLILHU

(3

 5HOHYDQWLGHQWLILHGXVHVRIWKHVXEVWDQFHRUPL[WXUHDQGXVHVDGYLVHGDJDLQVW
&RROLQJDJHQW

 'HWDLOVRIWKHVXSSOLHURIWKHVDIHW\GDWDVKHHW
$UFWLNR$6
/DPPHIMRUGVYHM
'.(VEMHUJ1
3KRQH
)D[
(PDLOLQIR#DUFWLNRFRP

 (PHUJHQF\WHOHSKRQHQXPEHU
 '. 


+ $=$5'6,'(17,),&$7,21

 &ODVVLILFDWLRQRIWKHVXEVWDQFHRUPL[WXUH
([WUHPHO\IODPPDEOHJDV0D\FRXUVHIURVWELWHV

(8 RU   )[5
&/3    )ODP*DV+3UHVV*DV

See the full text of risk- and hazard phrases in section 16.

/DEHO HOHPHQWV

(8
&RQWDLQV


 
([WUHPHO\IODPPDEOH

5([ WUHPHO\IODPPDEOH
6 .HHSFRQWDLQHULQDZHOOYHQWLODWHGSODFH
6 .HHSDZD\IURPVRXUFHVRILJQLWLRQ1RVPRNLQJ

2
6 7DNHSUHFDXWLRQDU\PHDVXUHVDJDLQVWVWDWLFGLVFKDUJHV
6 ,IVZDOORZHGVHHNPHGLFDODGYLFHLPPHGLDWHO\DQGVKRZFRQWDLQHURUODEHO


&/3
&RQWDLQV


 'DQJHU

+ ([WUHPHO\IODPPDEOHJDV
3 6WRUHLQDZHOOYHQWLODWHGSODFH
3 3.HHSDZD\IURPKHDWVSDUNVRSHQIODPHVKRWVXUIDFHV–1RVPRNLQJ
3 7DNHSUHFDXWLRQDU\PHDVXUHVDJDLQVWVWDWLFGLVFKDUJH 
33 ,)6:$//2:('*HWLPPHGLDWHPHGLFDODGYLFHDWWHQWLRQ 

2WKHU KD]DUGV
0D\FRXUVHIURVWELWHVLQFDVHRIFRQWDFWZLWKVNLQDQGH\HV
3%7Y3Y%7KHPL[WXUHGRHVQRWPHHWWKHFULWHULDIRU3%7Y3Y%LQDFFRUGDQFHZLWK5($&+$QQH[;,,


 &20326,7,21,1)250$7,2121,1*5(',(176

6XEVWDQFHV 
1RWDSSOLFDEOH

0 L[WXUHV
3URGXFWGHVFULSWLRQ/LTXHILHG*DV

6XEVWDQFHQDPH &$6QR(LQHFVQR  &ODVVLILFDWLRQ

+H[DIOXRURHWKDQH 5      (8 1RWFODVVLILHG
       &/31RW FODVVLILHG

7ULIORXURPHWKDQH 5       (8 1RWFODVVLILHG
       &/31RW FODVVLILHG

3URSDQH 5        (8 )[5
       &/3 )ODP*DV+
         3UHVV*DV

1%XWDQH 5       (8 )[5
       &/3 )ODP*DV+
         3UHVV*DV

See the full text of risk- and hazard phrases in section 16.

3
),567 $,'0($685(6

 'HVFULSWLRQRIILUVWDLGPHDVXUHV

,QKDODWLRQ
5HPRYHYLFWLPWRXQFRQWDPLQDWHGDUHDZHDULQJVHOIFRQWDLQHGEUHDWKLQJDSSDUDWXV.HHSYLFWLPZDUP
DQGUHVWHG&DOODGRFWRU$SSO\DUWLILFLDOUHVSLUDWLRQLIEUHDWKLQJVWRSSHG

6NLQFRQWDFW 
,QFDVHRIFRQWDFWZLWKOLTXLGVSLOODJH–IOXVKZLWKZDWHUIRUDWOHDVWPLQXWHV6HHNPHGLFDODWWHQWLRQ

(\HFRQWDFW
,QFDVHRIFRQWDFWZLWKOLTXLGVSLOODJH–IOXVKZLWKZDWHUIRUDWOHDVWPLQXWHV+ROGWKHH\HRSHQ
5HPRYHFRQWDFWOHQVHV6HHNPHGLFDODWWHQWLRQ

,QJHVWLRQ
6HHNPHGLFDODWWHQWLRQ

%XUQV
5LQVHZLWKZDWHUXQWLOWKHSDLQGLVDSSHDUV5HPRYHEXUQHGFORWKHVGXULQJULQVLQJ,IPHGLFDODWWHQWLRQ
LVQHFHVVDU\FRQWLQXHULQVHXQWLODGRFWRUWDNHVRYHU

 0RVWLPSRUWDQWV\PSWRPVDQGHIIHFWVERWKDFXWHDQGGHOD\HG
+LJKFRQFHQWUDWLRQVPD\FDXVHDVSK\[LDWLRQ6\PSWRPVPD\LQFOXGHORVVRIPRELOLW\FRQVFLRXVQHVV
9LFWLPPD\QRWEHDZDUHRIDVSK\[LDWLRQ/RZFRQFHQWUDWLRQVPD\FDXVHQDUFRWLFHIIHFWV6\PSWRPV
PD\LQFOXGHGL]]LQHVVKHDGDFKHQDXVHDDQGORVVRIFRRUGLQDWLRQ0D\FRXUVHIURVWELWHVLQFDVHRI
FRQWDFWZLWKVNLQDQGH\HV

 ,QGLFDWLRQRIDQ\LPPHGLDWHPHGLFDODWWHQWLRQDQGVSHFLDOWUHDWPHQWQHHGHG
,IWKHSHUVRQLVXQFRQVFLRXV&DOOLPPHGLDWHO\DGRFWRURUDQDPEXODQFH6KRZWKLVVDIHW\GDWDVKHHW
WRWKHPHGLFDOVWDII


),5(),*+7 ,1*0($685(6

([WLQJXLV KLQJPHGLD
$OONQRZQH[WLQJXLVKLQJDJHQWVFDQEHXVHG

 6SHFLDOKD]DUGVDULVLQJIURPWKHVXEVWDQFHRUPL[WXUH
([WUHPHO\I ODPPDEOH ([SRVXUHWRI LUH PD\FDXV HFRQWDLQHUVWRUXSWX UHH[SORGH. $YRLGLQKDO DWLRQR I
VPRNH,QFRPSOHWHFRPEXVWLRQPD\IRUPFDUERQPRQR[LGHFDUERQ\OIOXRULGHRJK\GURJHQIOXRULGH

$ GYLFHIRUILUHILJKWHUV
,QFRQILQHGVSDFHXVHVHOIFRQWDLQHGEUHDWKLQJDSSDUDWXV

6SHFLILFPHWKRGV
,ISRVVLEOHVWRSIORZRISURGXFW
0RYHDZD\IURPWKHFRQWDLQHUDQGFRROZLWKZDWHUIURPDSURWHFWHGSRVLWLRQ
'RQRWH[WLQJXLVKDOHDNLQJJDVIODPHXQOHVVDEVROXWHQHFHVVDU\
6SRQWDQHRXVH[SORVLYHUHLJQLWLRQPD\RFFXU
([WLQJXLVKDQ\RWKHUILUH


 $&&,'(17$/5(/($6(0($685(6

 3HUVRQDOSUHFDXWLRQVSURWHFWLYHHTXLSPHQWDQGHPHUJHQF\SURFHGXUHV
8VHSURWHFWLYHVXLW8VHVHOIFRQWDLQHGEUHDWKLQJDSSDUDWXVZKHQHQWHULQJDUHDXQOHVVDWPRVSKHUHLV
SURYHGWREHVDIH
(YDFXDWHWKHDUHD(QVXUHDGHTXDWHDLUYHQWLODWLRQ(OLPLQDWHLJQLWLRQVRXUFHV

4
 (QYLURQPHQWDOSUHFDXWLRQV
7U\WRVWRSUHOHDV H3UHYHQWI URPHQWHULQJV HZHUVEDVHPHQWVDQGZRUNSLWV RUDQ\SODF HZKHUHLWV 
DFFXPXODWLRQFDQEHGDQJHURXV 

 0HWKRGVDQGPDWHULDOIRUFRQWDLQPHQWDQGFOHDQLQJXS
9HQWLODWHDUHD

 5HIHUHQFHWRRWKHUVHFWLRQV
1RWDSSOLFDEOH

+ $1'/,1*$1'6725$*(

3UHFDXWLRQV IRUVDIHKDQGOLQJ
$YRLGLQKDO DWLRQDQGF RQWDFWP HGVNLQDQGH\HV .H HSDZD\I URPV RXUFHVRI L JQLWLRQLQFOXGL QJ
HOHFWURVWDWLFGLVFKDUJH
(QVXUHHTXLSPHQWLVDGHTXDWHO\HDUWKHG6XFNEDFNRIZDWHULQWRWKHFRQWDLQHUPXVWEHSUHYHQWHG
3XUJHDLUIURPV\VWHPEHIRUHLQWURGXFLQJJDV'RQRWDOORZUHIOX[LQWRWKHFRQWDLQHU
8VHRQO \SURSH UO\VSHF LILHGHTXL SPHQWZKLF KLV V XLWDEOHI RUWKLVSURGXF WLWV V XSSO\SUHVVXUH DQG 
WHPSHUDWXUH

 &RQGLWLRQVIRUVDIHVWRUDJHLQFOXGLQJDQ\LQFRPSDWLELOLWLHV
6HJUHJDWHI URPR[ LGDQWJDV HVDQGRWKHUR[ LGDQWVLQ VWRUH.HHSFRQWDLQHUEHO RZ  ƒ&LQDZHOO
YHQWLODWHGSODFH.HHSWKHFRQWDLQHUVHFXUHGDQGVDIHIURPFROOLVLRQ

6SHFLILF HQGXVH V 
6HHXVHLQVHFWLRQ


(;32 685(&21752/63(5621$/3527(&7,21

&RQWURO SDUDPHWHUV

6XEVWDQFHQDPH ([SRVXUHOLPLW   

3URSDQH  SSPPJP '.   
1%XWDQH  SSPPJP '.  


([SRVXUH FRQWUROV

$SSURSULDWHHQJLQHHULQJFRQWUROV
(QVXUHDGHTXDWHYHQWLODWLRQ

,QGLYLGXDOSURWHFWLRQPHDVXUHV
'RQRWVPRNHZKLOHKDQGOLQJSURGXFW3URWHFWH\HVDQGVNLQDJDLQVWVSODVKHVRIOLTXLG

5HVSLUDWRU\SURWHFWLRQ
,QFDVHRIJDVOHDNZHDUVHOIFRQWDLQHGEUHDWKLQJDSSDUDWXV

(\HSURWHFWLRQ
8VHJRJJOHVLIWKHUHLVULVNRIVSODVKHVRIOLTXLG

6NLQSURWHFWLRQ
8VHLQVXODWLQJJORYHVDQGSURWHFWLYHVXLWLIWKHUHLVULVNRIVSODVKHVRIOLTXLG

5


 3+<6,&$/$1'&+(0,&$/3523(57,(6

 ,QIRUPDWLRQRQEDVLFSK\VLFDODQGFKHPLFDOSURSHUWLHV

$SSHDUDQFH &RORXUOHVVJDV
2GRXU 6ZHHWLVK3RRUZDUQLQJSURSHUWLHVDWORZFRQFHQWUDWLRQ
2GRXUWKUHVKROG 1RWDYDLODEOH
S+ 1RWDSSOLFDEOH
0HOWLQJSRLQWIUHH]LQJSRLQW 1RWDYDLODEOH
,QLWLDOERLOLQJSRLQWDQGERLOLQJUDQJH 1RWDYDLODEOH
)ODVKSRLQW 1RWDYDLODEOH
(YDSRUDWLRQUDWH 1RWDYDLODEOH
)ODPPDELOLW\ 1RWDYDLODEOH
8SSHUORZHUIODPPDELOLW\RUH[SORVLYHOLPLWV 1RWDYDLODEOH
9DSRXUSUHVVXUH 1RWDYDLODEOH
9DSRXUGHQVLW\ 1RWDYDLODEOH
5HODWLYHGHQVLW\ 1RWDYDLODEOH
6ROXELOLW\ LHV  1RWDSSOLFDEOH
3DUWLWLRQFRHIILFLHQW QRFWDQROZDWHU 1RWDYDLODEOH
$XWRLJQLWLRQWHPSHUDWXUH 1RWDYDLODEOH
'HFRPSRVLWLRQWHPSHUDWXUH 1RWDYDLODEOH
9LVFRVLW\ 1RWDYDLODEOH
([SORVLYHSURSHUWLHV 1RWDYDLODEOH
2[LGLVLQJSURSHUWLHV 1RWDYDLODEOH

3K\VLFDOKD]DUGV )ODPPDEOHJDV  )ODP*DV+ 
  
2 WKHULQIRUPDWLRQ
1RWUHOHYDQW


 67$%,/,7<2*5($&7,9,7<

5HDFWLYLW\
1RWDYDLODEOH

&KHPLFDOVWDELOLW\
0D\GHFRPSRVHYLROHQWO\DWKLJKWHPSHUDWXUHDQGRUSUHVVXUHRULQWKHSUHVHQFHRIDFDWDO\VW

3RVVLELOLW\RIKD]DUGRXVUHDFWLRQV
&DQIRUPH[SORVLYHPL[WXUHZLWKDLU0D\UHDFWYLROHQWO\ZLWKR[LGDQWV

&RQGLWLRQVWRDYRLG
.HHSDZD\IURPKHDW

,QFRPSDWLEOHPDWHULDOV
$YRLGFRQWDFWZLWKR[LGL]LQJDJHQWV

+D]DUGRXVGHFRPSRVLWLRQSURGXFWV
,QFRPSOHWHFRPEXVWLRQPD\IRUPFDUERQPRQR[LGHFDUERQ\OIOXRULGHDQGK\GURJHQIOXRULGH



6
7 2;,&2/2*,$/,1)250$7,21

,QIRUPDWLRQRQWR[LFRORJLFDOHIIHFWV

+D]DUGFODVV 'DWD 7HVW 6RXUFH
$FXWHWR[LFLW\   
,QKDODWLRQ 1RWDYDLODEOH  
'HUPDO 1RWDYDLODEOH  
2UDO 1RWDSSOLFDEOH  
6NLQFRUURVLRQ 1RWDYDLODEOH  
LUULWDWLRQ
6HQVLWLVDWLRQ1RW DYDLODEOH  
&051RW DYDLODEOH  


,QIRUPDWLRQRQOLNHO\URXWHVRIH[SRVXUH
6NLQH\HVDQGLQKDODWLRQ

,QKDODWLRQ
+LJKFRQFHQWUDWLRQVPD\FDXVHDVSK\[LDWLRQ6\PSWRPVPD\LQFOXGHORVVRIPRELOLW\FRQVFLRXVQHVV
9LFWLPPD\QRWEHDZDUHRIDVSK\[LDWLRQ/RZFRQFHQWUDWLRQVPD\FDXVHQDUFRWLFHIIHFWV6\PSWRPV
PD\LQFOXGHGL]]LQHVVKHDGDFKHQDXVHDDQGORVVRIFRRUGLQDWLRQ0D\FRXUVHIURVWELWHVLQFDVHRI
FRQWDFWZLWKVNLQDQGH\HV

6NLQFRQWDFW
0D\FRXUVHIURVWELWHV

(\HFRQWDFW
0D\FRXUVHIURVWELWHV

,QJHVWLRQ
,QJHVWLRQLVQRWFRQVLGHUHGDSRWHQWLDOURXWHRIH[SRVXUH

/RQJWHUPHIIHFWV
1RNQRZQORQJWHUPHIIHFWV


(FRORJLFDO LQIRUPDWLRQ

7R[LFLW\

$TXDWLF'DWD  7HVW 6RXUFH
PHGLXP 
)LVK1RW DYDLODEOH  
&UXVWDFHDQV1RW DYDLODEOH  
$OJDH1RW DYDLODEOH  


3HUVLVWHQFHDQGGHJUDGDELOLW\
1RWDYDLODEOH

%LRDFFXPXODWLYHSRWHQWLDO
1RWDYDLODEOH

0RELOLW\LQVRLO
1RWDYDLODEOH

5HVXOWVRI3%7DQGY3Y%DVVHVVPHQW
1RWDYDLODEOH

7
 

2WKHUDGYHUVHHIIHFWV
1RWDYDLODEOH


',6326 $/&216,'(5$7,216

:DVWHWUHDWPHQWPHWKRGV
'RQRWGLV FKDUJHLQWRDUHDV ZKHUHWKHUHLVD ULVN RIIRUPLQJDQH[ SORVLYHPL[WXUHZLWKDLU:DVWHJDV
VKRXOGEHIODUHGWKURXJKDVXLWDEOHEXUQHUZLWKIODVKEDFNDUUHVWRU
'RQRWGLVFKDUJHLQWRDQ\SODFHZKHUHLWLVDFFXPXODWLRQFRXOGEHGDQJHURXV

(PSW\ERWWOHVDQGERWWOHVZLWKUHVLGXHVVKRXOGEHUHWXUQHGWRWKHVXSSOLHU


7 5$163257,1)250$7,21

81QXPEHU
81

81SURSHUVKLSSLQJQDPH
81/LTXHILHGJDVIODPPDEOHQRV 1EXWDQHSURSDQH 

7UDQVSRUWKD]DUGFODVV HV 
 &ODVVLILFDWLRQFRGH) 

3DFNLQJJURXS
1RWDSSOLFDEOH

(QYLURQPHQWDOKD]DUGV
7KHPL[WXUHLVQRWDQHQYLURQPHQWDOKD]DUG

6SHFLDOSUHFDXWLRQVIRUXVHU
$YRLGWUDQVSRUWRQYHKLFOHVZKHUHWKHORDGVSDFHLVQRWVHSDUDWHGIURPWKHGULYHUVFRPSDUWPHQW
(QVXUHYHKLFOHGULYHULVDZDUHRIWKHSRWHQWLDOKD]DUGVRIWKHORDGDQGNQRZVZKDWWRGRLQWKHHYHQW
RIDQDFFLGHQWRUDQHPHUJHQF\

%HIRUHWUDQVSRUWLQJSURGXFWFRQWDLQHUV
 (QVXUHWKDWFRQWDLQHUVDUHILUPO\VHFXUHG
 (QVXUHF\OLQGHUYDOYHLVFORVHGDQGQRWOHDNLQJ
 (QVXUHYDOYHRXWOHWFDSQXWRUSOXJ ZKHUHSURYLGHG LVFRUUHFWO\ILWWHG
 (QVXUHYDOYHSURWHFWLRQGHYLFH ZKHUHSURYLGHG LVFRUUHFWO\ILWWHG
 (QVXUHWKHUHLVDGHTXDWHYHQWLODWLRQ
 &RPSOLDQFHZLWKDSSOLFDEOHUHJXODWLRQV

7UDQVSRUWLQEXONDFFRUGLQJWR$QQH[,,RI0$532/DQGWKH,%&&RGH
1RWDSSOLFDEOH

8
5(*8/ $725<,1)250$7,21

6DIHW\KHDOWKDQGHQYLURQPHQWDOUHJXODWLRQVOHJLVODWLRQVSHFLILFIRUWKHVXEVWDQFHRU
PL[WXUH
<RXQJSHRSOHXQGHU\HDUVPD\QRWZRUNZLWKWKLVSURGXFW7KHXVHUPXVWEHLQVWUXFWHGEHIRUHXVH
DQGEHIDPLOLDUZLWKWKHFRQWHQWRIWKLV6DIHW\'DWD6KHHW

&KHPLFDOVDIHW\DVVHVVPHQW
1RWDYDLODEOH


27 +(5,1)250$7,21

)XOOWH[WRIKD]DUGDQGULVNSKUDVHVLQVHFWLRQ
5([ WUHPHO\IODPPDEOH
+ ([WUHPHO\IODPPDEOHJDV 



6LQFHFRQVXPHULVZRUNLQJRXWVLGHRIRXUNQRZOHGJHDQGRXUFRQWUROEHDZDUHWKDWLWDOZD\VLV
WKHFRQVXPHUVUHVSRQVLELOLW\WRPDNHWKHQHFHVVDU\VWHSVWRFRPSO\ZLWKDSSOLFDEOHUHJXODWLRQV

$0*UXSSHQ$6-XO\

9
5e. Controller G-214

1 2 3 Alarm (red light) Alarm Battery (red light)

On/off or exit menu

Up, down, left,


right button to scolls
through the menu
6

4 5 6 7 8 Return Enter (accesses the menu, accept)


Mute alarm

USB Data download

Control Panel Description


Push the UP button in order to generate
1. Temperature indicator
a graph.
2. Alarm indivator
3. Alarm-icons
Push the LEFT button in order to return
4. Compressor indication
up to 10 days back.
5. Date indication
6. Hour indication
Push the Esc button in order to exit the
7. Ambient temperature indicator
menu.
8. Battery level
9. USB-Connection

50
Setting icons

Custom Settings
Custom Settings

Advanced Settings
Advanced Settings

Advanced Service Settings

Advanced Service Settings

Status

Status

Change / Reset password


Change / Reset password

51
Custom Settings

Enter password
The menu Custom setting is protected with a password, wich is “0000”
to access the menu.

Under the menu Setpoint the temperature for the unit will
be set.
Setpoint

Under the menu Alarm Settings the below menu will be


avaible.

The menu Alarm delay is the settings of the


time from an alarm will occur on the unit and
until it will be shown on the display.
(Only temperature alarms)

The menu Door open alarm is the settings of


the time from an alarm will occur on the unit
Under the menu and until it will be shown on the display.
Select language you
can select the desired
language. The menu High temp. alarm is the settings of
the highest temperature the device must be in-
side before it comes with an alarm.

The menu Low temp. alarm is the settings of


the lowest temperature the device must be in-
side before it comes with an alarm.

The Probe eprom failure alarm indicate, that


the probe is not working.
Probe eprom failure

The Power failure alarm indicate, that there is


no power to the unit.

The menu Alarm log time interval is the


settings of time for the controller to log data
from the unit.

52
Advanced Settings

Enter password
The menu Advanced Settings is protected with a password wich is “0000”
to access the menu.

The menu Calibration is the settings for offset of the tempe-


rature in the display.

The menu Automatic defrost is the setting of the time where


a defrost automatic will be performed on the unit.

Under the menu Manual defrost the deftrost can be started


immediately.

The menu Hysteresis is the setting of the different from the


setpoint whwere the compressor will start and stop.

The menu Temp. range limits is the settings of the maximum


and minimum temperature the unit can be used for.

Service
Service

The menu Password protection is the setting of the protection


for the unit not to be turn off and is protected with a password.
Password protection

The menu Set date / time is the setting of date and time.

The menu Ambient temp. settings is the adjustment of the


ambient temperature.

53
Service Settings
Under the menu Service, there is information about the unit, which is
Service important for service on the unit.

The menu Compressor hours shows, how many hours


the compressor has run.

The menu Fan hours shows, how many hours the fan
has run.

Under the menu Probe the temperature for the sensor


mounted in the unit is displayed.

Under the menu Probe inside unit the tempe-


rature of the sensor mounted inside the unit is
displayed. There is mounted a sensor as stan-
dard in the unit, but it is possible to mount 3
sensors inside the device. (Controller version)

Under the item Probe Compressor the


temperature of the sensor mounted on the
compressor is displayed.
Probe Compressor (Not all models)

Under the point Probe evaporator the tempe-


rature of the sensor, that is located on the
Probe evaporator condenser, is displayed.

54
Advanced Service Settings
This menu is only used by the service department at the manufacturer.
Advanced Service Settings

Status

The Current alarms shows the alarm, which have been on


the unit with data and time.

The Temp. last 24 hours shows the temperature of the unit


the last 24 hours.

Change / Reset password

Under Change password it is possible to change the


password for Customer Settings, Advanced Settings
and Advanced Service Settings.

Under Reset password it is possible to reset the pass-


word for the Customer Settings, Advanced Settings
and Advanced Service Settings.
Contact the manufactorer to get the password for reset
password.

55
Download Data

Place the USB pen drive in the connection on the display and press the
button right for read data from the unit to the USB pen.
USB connected

The Read data will be shown in the display when the


data is loading to the USB pen drive.

The Transfer complete will be shown on


the display when the loading is finished and
the USB pen can be removed from the display.

Open the 2 files:


data00 and param00
on a computer in Excel or similar.

Upload Data (Only for new settings from the manufactury)


Turn-off the display before start.
Place the USB pen drive in the connection on the display and press the
button left for upload parameters from the USB pen to the unit.
USB connected

The Data upload will be shown in the display when the


data is loading to the unit.

The Transfer complete will be shown on


the display when the loading is finished and
the USB pen can be removed from the display.

56
Alarms on display

Alarm icons

The Door open alarm indicate, that the door is not correct
closed

The High temperature alarm indicate, that the temperature


inside the unit is higher than permitted from setting of the unit.

The Low temperature alarm indicate, that the temperature


inside the unit is lower than permitted from setting of the unit.

The Probe eprom failure alarm indicate, that the probe is


not working.
Probe eprom failure

The Power failure alarm indicate, that there is no power to


the unit.

The Low battery alarm indicate, that the power on the


battery is to low.

57
5f. Default settings

Description Arctiko default Customer


settings settings
Custom Settings (Password) 0000

Set po int
Freezer -80,0

Alarm Settings:

Alarm delay
Freezer 15 min

Door open alarm


Freezer Enable

High temp. alarm


Freezer -70

Low temp. alarm


Freezer -90

Probe/eprom failure
Freezer Enable

Power failure
Freezer Enable

Alarm log time interval


Freezer 1

Description Arctiko default Customer


settings settings
Advanced Settings (Password) 0000

Calibration
Freezer 0,0

Automatic defrost
Freezer 0

Manual defrost
Freezer OK

Hy steresis
Freezer 2,0

Temp. range limits


Freezer Max. - ,0
Freezer Min. - ,0

58
59
DK-6715 Esbjerg N
Denmark
Tel. +45 7020 0328
Fax. +45 7020 0329
info@arctiko.com
www.arctiko.com

50 81 501-03-GB

You might also like