Version No: 03 Department: Power Plant SMP No: 2201/INST/WI-08 Revision No: 01 Revision Date:
a) To align the transceiver, look through the alignment sight on the side of the transceiver housing.
Make sure the reflector is closed on the reflector side.
b) Then by adjusting the nuts on the stack flange of the transceiver side as shown in the previous
figure, move the transceiver in the horizontal and vertical directions until the reflector image is
centered in the “bulls eye” of the alignment sight.
c) Please note that as the transceiver is moved horizontally, the image in the alignment site will move
vertically.
Version No: 03 Department: Power Plant SMP No: 2201/INST/WI-08 Revision No: 01 Revision Date:
On longer-range systems the image in the alignment sight may not appear very bright. It may be
helpful to cup your hands around the eye piece of the alignment site to block the ambient light
when aligning the transceiver.
d) The adjustment nuts should compress the spring washers to the point that the transceiver (or
reflector) is stable. The spring washers should not be completely compressed, then there would be
no room for further adjust the alignment.
7.13. Ensure proper covering of the Trans-receiver unit, reflector unit and the control unit.
Revised By : Rakesh Ranjan Das
Prepared by : Amarendra Sahoo Date of Issue : 10.05.2015
Checked By : P.K. Singh
Date of preparation : 08.04.2008 Date of review : 23.05.2021
Approved By: Susheem Kumar Behera
VEDANTA LIMITED, LANJIGARH
Integrated Management System
SMP description: SMP For Opacity Meter
Version No: 03 Department: Power Plant SMP No: 2201/INST/WI-08 Revision No: 01 Revision Date:
DURING CALIBRATION
Version No: 03 Department: Power Plant SMP No: 2201/INST/WI-08 Revision No: 01 Revision Date:
7.23. After the LED current is set, the monitor will determine the amplification of the comparison normal light
beam. The lower line of the display will be active and segment three will show the amplification factor.
This should be in between 10 to 50.
7.24. After the basic set-up is complete, a calibration cycle will run (the yellow LED will go out). To prevent
any further changes to the monitor set-up, put switch S5 to the back (the red LED will extinguish). On
switch S4 put S4/6 in the ON position. If S4/6 on the S4 switch was already returned to the ON
position before the basic set-up is completed, any previously recorded filter audit (linearity) data was
preserved.
7.25. Once the calibration cycle has been completed (the yellow LED will not be lit), disconnect the transceiver
and controller (power off) and replace the cover with the six screws.
7.26. Carryout the steps 7.9 to 7.11.
7.27. Fix the calibration tag.
7.28. Return the PTW.
8. QUALITY:
8.1. All the parameters, activities are maintained within prescribed limit. (Accuracy: ±1.0 % FSD)
8.2. Any deviation from the norm is recorded and corrective action is taken accordingly.
Version No: 03 Department: Power Plant SMP No: 2201/INST/WI-08 Revision No: 01 Revision Date:
9. ENVIRONMENT:
Not applicable
10. ENERGY:
Not applicable
11. OHSAS:
11.1. Ensure PPE, Helmet, adequate lighting near the work place.
11.2. Ensure healthiness & safety of the entire activities with respect electrical system
11.3. Ensure deployment of a group of people (2 or more) while carrying out job in an isolated or deserted
place or in night shift.