Through Coating Ultrasonic Thickness Gauge MT180

Product Description:

The MT180 is a multi-mode ultrasonic thickness gauge, capable of measuring the thickness of various
material types with a high degree of accuracy. The multi-mode feature of the gauge allows the user to
toggle between pulse-echo mode for normal thickness measurement, and echo-echo mode which will
eliminate any paint or coating thickness from the reading.

Features:

 Multi-mode: Pulse-Echo mode and Echo-Echo mode.


 Capable of performing measurements on a wide range of material, including metals, plastic,
ceramics, composites, epoxies, glass etc.
 Various probes (transducers) are available for special application requirements.
 One and two-point calibration function.
 Single point mode and Scan mode. Seven measurements readings per second in single point
mode, and sixteen per second in Scan Mode.
 Coupling status indicator showing the coupling status.
 Units: metric or imperial readout is selectable.
 Battery capacity indicator.
 Auto sleep and auto power off function to conserve battery life.
 Optional software to process the memory data on the PC.
Configuration:

 The standard configuration includes the instrument, P5EE 5 MHz probe, 2 AA alkaline
batteries, couplant, manual and carries case.
 Options include the standard 2 MHz, 5 MHz and 7 MHz probes, the 5 MHZ HT high temp
probe, and the download software and cable.

Specifications:
 Range in pulse-echo mode: 0.65~600 mm in steel.
 Range in echo-echo mode: 3~30 mm in steel.
 Sound Velocity Range: 1000~9999 m/s.
 Resolution: 0.1 mm/0.01 mm.
 Accuracy: ± 0.5% of the thickness reading + 0.01 mm depending on material type and
conditions.
 Memory storage of up to 20 files, with up to 99 values per file.
 LCD display.
 Two “AA” size, 1.5 Volt alkaline batteries allowing for up to 100 hours typical operating time.
 Dimensions:150 mm×74 mm×32 mm.
 Weight:245 grams.

Operating Conditions:

 Operating Temperature: -20°C~+ 60°C;


 Storage Temperature:-30°C~+ 70°C
 Relative Humidity ≤90%;
 The surrounding environment should be free of vibration, strong magnetic fields, corrosive
materialsand heavy dust

Transducer Selection:

Freq Diameter
Model Measuring Range Lower limit Description
(MHz) (mm)
Echo-Echo mode:
Trough Coating
P5EE 5 12 (3~30)mm for MT180 Φ20mm×3.0mm
Measurement
(3~60)mm for MT190.
1mm~600.0mm
N05 5 10 Φ20mm×3.0mm Normal Measurement
(In Steel)
For thin pipe wall or
0.65mm~200.0mm
/90° N07 7 6 Φ15mm×2.0mm small curvature pipe wall
(In Steel)
measurement