Technical Datasheet Fire Extinguisher

You might also like

Download as pdf
Download as pdf
You are on page 1of 3
No..date, performance warrantee minimum 2 years from the date of supply, manufacturers name &inspector stamp shall be punched 7. TECHNICAL SPECIFICATON OF Wind Sock: + Material: Double lined Polyster cloth; + Size: 2ft + Colour: Red and White + Wind sock with stand. Complete set of wind sock with double ball bearing with 6ft MS long pipelrod 8.TECHNICAL SPECIFICATION OF KG DCP FIRE EXTINGUISHER (ISI MARK) With ISI Mark-2171 (Latest) complete with initial charging of CO2 CARTRIDGE (200 gms) with ISI Mark-4947 (Latest) and dry chemical powder with ISI Mark-4308 (Latest) SPECIFICATIONS: a. Size of filler opening (inner dia) not less than 75 mm.Length of inner container not less than 35 cm. b. Cap shall be of gunmetal with chromium plating. ¢. Hose shall be of braided plastic high pressure with one meter length with nozzle of ABS Plastic. d. All other components, design and performance, anticorrosive treatment shall be as per 15:1271 latest. e. Certification that every extinguisher shall be of Radiographic quality welding and fabrication and design of vessel shall be as per IS2825, In addition to markings stipulated in IS:2171 (latest) the following permanent punching at the bottom ring is required. vr Manufacturer's name ve Year of manufacturing pr Manufacturers serial number vr Purchase Order No. and date. wr Inspector Stamp. vr The date of hydraulic rest shall also be marked, Space shall be left for writing the dates of subsequent hydraulic test Dry Chemical Powder filling height shall be marked on the extinguisher. Rs Page 21 of 12 9, TECHNICAL SPECIFICATIONS KG. DCP FIRE EXTINGUISHER (ISI MARK): a. Made of 6 mm thick M.S. Sheet (B.Q. Plate & design of vessel as per IS: 2825) with radiography quality welding. The extinguisher shall be conforming to 18:10658-1983. Extinguisher to be treated with anticorrosive treatment. Non- ferrous parts shall be gunmetal. Design calculation of the extinguisher shall be submitted along with the offer. b. The hose shall be of minimum 05 mm meters length and the bursting pressure shall not less than 50 Kg/Cm2. ¢. Drain plug of not less than 25 mm diameter to be provided on the body d. The nozzle shall be of Trigger Controlled and capable of discharging powder as per ISI Specification. e. Automatically and manually operated Safety Relief Valve to be provided as per IS:10658 (Latest) specification. f. Pressure gauge having minimum 50 mm dia. and range from 0 to 42 Kg/Cm2 to be provided on the body. g. The extinguisher to be mounted on robust trolley having two heavy duty bearing fitted rubberized wheels and strong handles for easy mobility. h. ISI Marked CO2 gas cylinder shall be of 2 Kg. Capacity and shall be approved by Department of Explosives with protector and thermal insulation and to be fitted with ISI marked wheel type Valve. i. Dry Powder with ISI Mark IS:4308 (Latest). The powder shall be packed in plastic rigidex material type bags with heavy duly LD lines duly hermetically sealed. The materials of packing and sealing is to be made in such a way that if the pack is kept inside the water bucket for 24 hours, not a single drop of water will penetrate inside the bag & the characteristics of the powder shall remain unaffected against moisture. j. Painting Two coats primer (red oxide) painting and then fire red painting by spray method, k. As per 15-2825, Dye penetrated test of the fillet weld of all nozzles and attachment No discontinuities in the welding. | As per 1S:2825, Radiography (10%covering50% of “T" Joints)- No discontinuities allowed. m. The extinguisher shall be hydro tested at 30 Kg/cm2 and shall not develop any leaks at this pressure. Page 22 of 12 n, In addition to markings stipulated in IS:10658 (latest) the following permanent punching at the bottom ring is required. ‘Manufacturer's name Year of manufacturing ‘Manufacturers serial number Purchase Order No. and date. Inspector Stamp. The date of hydraulic rest shall also be marked. Space shall be left for writing the dates of subsequent hydraulic test * Dry Chemical Powder filling height shall be marked on the extinguisher. 10) TECHNICAL SPECIFICATION FOR MV SPRINKLER NOZZLES Manufacturer / Make : Vendor to specify Code / Standard : Manufacturer's Standard Model : Auto Operated . Installation : Outside / Inside, Fixed >. Design Pressure : 18 Kg/cm2g . Hydraulic Test Pressure : 21 Kg/cm2g Material of Construction : Forged Brass . K-factor : vendor to specify Spray Angle : vendor to specify 10. Finish : Red powder coated or nickel chrome plated 11, Weight : vendor to specify 12. Required Normal Water : 3.5 Kg/cm2 Pressure 13, Approval : UL Certified O@IOARONS GENERAL NOTES: A). SCOPE * As per BOQ B). Nozzle shall produce 120 degree (As per the K-factor) uniform conical spraypattern covering a circular area of about 3 m diameter when located about 1 m away from the surface to be protected. C). The nozzle shall have ahexagonal or square shape on the outer side tofacilitate screwing of the nozzle to female half coupling welded to the waterring, D). WORKMANSHIP AND FINISH All parts shall be of good workmanship andfinish, Sharp edges on all the parts shall be removed, The water ways shall have smooth finish. E). INSPECTION Final / stage inspection shall be carried out by Consultant /Owner's authorised representative at manufacturer's works, F). MARKING Each nozzle shall be clearly marked with the following: Page 23 of 12

You might also like