Expert Series
Quick Card
31
27
28
29
30
26
6
9 1
8 10 12
2 4 5 7 11
13
19 20
3
18 21
15
14
17 23
16
24
22
25
5 End Exam 14
Custom Keys 25 Trackball and Trackball Keys
Multi-function control knobs with 15 Body Marker Key 26 Touch Footer
6
corresponding Touch Footer controls
16 Menu Exit Key 27 Shortcuts
7 PW mode and gain control/X axis*
17 Arrow Key 28 Eject Media
8 M mode and gain control/Y axis*
18 Annotation/Abc Key 29 DVR Menu
9 PD mode and gain control/Z axis*
19 Clear key 30 XL Format
CF mode and gain control/
10 31 Home
Parallel Shift* 20 Measure/Calc key
*3D Control
Voluson Expert Series
Quick Card
4. To End exam, select “End Exam” key (5). Activate Power Doppler or HD-Flow™ in the same way with the
“PD mode” key (9).
Calculation measurements To switch between PD and HD-Flow, use touch panel control.
1. Press the “Measure/Calc” key (20). The calculation package for
the active application (e.g. OB) will appear on the touch panel. PW mode (Pulsed Wave Doppler mode)
2. Select the desired calculation. 1. Press the “PW mode” key (7).
3. The calipers can be set by “Right or Left trackball” key (25). 2. Adjust the PW cursor position and gate size with the
trackball on the 2D image. The “Top trackball” key (25)
4. For patient report, press “Report” key (4). switches between gate position and gate width.
Generic measurements 3. Press the “Left trackball” key (25) to start the spectral Doppler.
1. Press the “Measure/Calc” key twice for generic measurements (20). 4. The “PW mode” key (7) is also the PW spectrum gain control.
2. Select the desired measurement from the touch panel (e.g. generic
dist). Entering and setting of calipers is done with the “Right or Left Note:
trackball” key (25) Endpoints can be adjusted with “Top trackball” To deactivate all modes, press the “2D mode” key (11).
key; calipers are set with “Right or Left trackball” key.
Important note:
3D/4D mode An Electronic Instruction for Use (IfU) is integrated on the
1. Press the “3D or 4D” key (21). Voluson Expert Series system. Press Home (31) to access the IfU.*
2. If choosing 4D, select the desired 4D mode on the top of the Touch Footer
touch panel. Functions found on “Multi-function control knobs” (6) can also
The “Right trackball” key (25) or “Freeze” key (24) will be controlled via the “Touch Footer” (26) with tap or slide action.
begin the acquisition.
* First-time selection of the IfU requires the documentation DVD or USB to be inserted.
Products mentioned in the material may be subject to government regulations and may not
be available in all countries. Shipment and effective sale can only occur after approval from
the regulator. Please check with local GE HealthCare representative for details.