SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
CONDUCTORS, BARE
1. 1
BARE CONDUCTORS TYPE ACAR/ACSR/ACSR-AW/AAAC Applicable Standards: 10-TMSS-01
Website -
http://www.alcoa.com/usa/en/home.as
p
ALFANAR ELECTRICAL SYSTEMS ACAR, ACSR, ACSR/AW and AAAC Type Tests PQ Letter
Saudi Arabia performed for ACSR Based on S&SD letter# 13-02020-01-30504401
Conductor dated July 30, 2013, it is pre-qualified with the
Plant -3Rd Industrial Area, Al Kharaj at:Kinectrics - following: conditions.
Road, Riyadh Saudi Arabia Canada dated 11th
Feb 2013, Report #
Po Box 301 , Riyadh 11411 , North Righ K419415-RC-0001-R CONDITION:
Road Between Exit 5 & 6 Riyadh , 01 The first batch of AAAC, ACSR/AW & ACAR
Saudi Arabia type conductors shall be type tested at an
independent testing laboratory in the presence of
Contact Person - Mr. Ahmed Al Afifi (03) SEC/National Grid SA repreentatives and
Phone - +966-500857946 one approved third party inspector and all cost
Email ID - ahmed.al-afifi@alfanar.com pertaining to tests shall be borne by the
manufacturer.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmd by the manufacturer
through their letter #C-PRQ-2013-02 dated June
17, 2013.
1. 1 Page 1 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
APAR INDUSTRIES LTD. Imdad Support & ACAR, ACSR, ACSR/AW and AAAC Tests Performed for PQ Letter
INDIA technical AAAC Conductor Based on TS&SD Letter # 10-01566-2-03032300
PO Box 56451 Riyadh (Stress Strain, dated 14/06/2010, it is pre-qualified with the
Plant -Nalagarh Plant, Silvassa Plant 11554 Breaking Strength, following conditions:
Phone - 011-4657556 x UTS and
Nalagarh Plant: 222,311 Longitudinal CONDITION:
Khasra No. 467, Hadbast No. 101, Email – Smoothness) at The first batch of ACSR, ACSR/AW & ACAR type
Muuza Beer Plassi Tec. Nalagarh P.O Imd1adtech@gmail.com VEIKI-VNL, conductors shall be type tested at an
Manjhauli (Jagatkhana) District Solan Budapest – Hungary independent testing laboratory in the presence of
(H.P) 174 101 India in Jan., 2014) (03) SEC/National Grid SA repreentatives and
Tel: 0091-01795-200384 Report # 7765/VNL one approved third party inspector and all cost
E-mail: agv@apar.com pertaining to tests shall be borne by the
manufacturer, as confirmed by the manufacturer
through letter # AIL/BRD/PQ/SEC/19, dt: 22nd
SILVASSA Plant: May, 2010.
Survey No. 148/1 Kudacha, Silvassa,
Rakholi Road, Silvassa (U.T.OFD & NH) WARRANTY:
-396230 INDIA Ten (10) years warranty from the date of PAC of
Tel: 0091-260-2630193-194 the turnkey project in case of contract award or
Fax, 0091-260-2630916 date of delivery in case of direct material supply
E-mail: ashwin@apar.com order. This has been confirmed in writing by the
manufacturer; through letter # AIL/BRD/
SEC/PQ/19 dated 22nd May 2010.
1. 1 Page 2 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Bahra Advance Cable Manufacture Co. ACAR, ACSR, ACSR/AW and AAAC Type tests on all PQ Letter
Ltd type of conductors Based on S&SD letters # 15-01562-1-30504401
Saudi Arabia performed (October dated 18th March 2015 & #
03-09, 2015) at 15-04785-1-30504401 dated 18th November,
Po Box 5989 Jeddah 21432 , Saudi Kinectrics 2015, it is pre-qualified with the following
Arabia Laboratory Toronto conditions:
Canada,
Contact Person - Mr. Loai Taha Al-Bar, Report No. WARRANTY:
Sale Manager K-419714-RC-0001- Ten (10) years extended warranty/guarantee in
Phone - +966-2-591-1115 R01 & . respect of defects due to design, manufacture,
Email ID - Loai.albar@bahra-cable.com K-419714-RC-0002- installation & workmanship from the date of the
R01 Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award
Kinectrics Report # and from the date of first delivery in case of
K-419605-RC-0001- direct material supply order .This was confirmed
R00 & in writing by the manufacturer through their letter
K-419605-RC-0002- # (BCC/SEC/LAB/GSM/MZ) dt: December 9, 2015.
R00
Kinectrics Report #
K-419714-RC-0001-
R01 &
K-419714-RC-0002-
R01
1. 1 Page 3 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
JEDDAH CABLE CO. ACAR, ACSR, ACSR/AW and AAAC Type Tests for PQ Letter
Saudi Arabia Conductors type Based on S&SD Letter No. 16-09867-30504401
ACSR, ACSR/AW, dated 7 Dec 2016 , JEDDAH CABLE Co. Jeddah
Po Box 31248 , Jeddah 21497 Jeddah , AAAC, ACAR were -K.S.A is Pre-qualified with following condition.
Saudi Arabia performed in
KINECTRIC WARRANTY:
Contact Person - Mr. Mohammad Said International Inc. Ten (10) years extended warranty from the date
Minkara Laboratory of PAC of the first turnkey project in case of
Phone - +966-126360770 –CANADA , contract award or date of first delivery in case of
Email ID - KINECTRICS Report# direct material supply order.
sayoubi@cables.energya.com , K-419635-RC-0001-
msminkara@cables.energya.com R01,
Website - K-419635-RC-0002-
http://www.cables.energya.com R01,
K-419635-RC-0003-
R01,
K-419635-RC-0004-
R01,
JCC-EP-PQ-0102-14
-34.
MIDAL CABLE , ACAR, ACSR, ACSR/AW and AAAC Type test conducted PQ Letter
Saudi Arabia from 25.08.2015 to Based on S&SD letter # 15-09640-030504401
04.09.2015 at dated November 24, 2015, it is pre-qualified with
Plant -Al Khobar different the following conditions:
laboratories in
P.O. Box 2312 Al Khobar 31952 Saudi Germany Viz SAG, WARRANTY:
Arabia ISP Institues, State Ten (10) years extended warranty from the date
Material testing of PAC of the first turnkey project in case of
Contact Person - Mr.Ammar Al Khuzaei institute ,FGH etc. contract award or date of first delivery in case of
General Manager Marketing & Sales , (Test Report # direct material supply order as
Mr. Mahadi Hussain 2015-049A, confirmed through Letter # Nil dated 19.10.2014.
Phone - +966-13-8988989 2015-049C &
+966-509994288 2015-049D)
Email ID - midalksa@midalcable.com
Hussain@midalcable.com
Website - http://www.midalcale.com
1. 1 Page 4 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
MIDAL CABLE LTD. ACAR, ACSR, ACSR/AW and AAAC Tests performed at:
BAHRAIN Manufacturer’s Lab.
(2014/2013/2010)
Plant -Bahrain Report #:
AAAC/P-1634-C/14/
Midal Cable Ltd. Bahrain Po Box 5939 01
Manama, Bahrain, Bldg. 744 Road 5128 AAAC/P-1196-C/13/
Block 951 Askar Road Bahrain. 08
Manama , Bahrain ACSR/P-890-C/10/0
4
Contact Person - Mr. Ammar Al Khuzaei ACSR/P-1087-C/11/
Phone - +973-17832832 27
Email ID - ammar@midalcable.com ACSR/AW/P-696C/0
Website - http://www.midalcable.com/ 8/29
ACSR/AW/P-814C-A
/09/03
ACAR/P-1000-C/11/
23
RIYADH CABLES ACAR, ACSR, ACSR/AW and AAAC Tests performed at:
Saudi Arabia KSU Laboratory,
Riyadh K.S.A (July
P.O. Box 26862- Riyadh, 11496 Riyadh 2014)
, Saudi Arabia Report #
2014-OHL-2-ACSR/
Contact Person - Dr. Nabiah Al-Saati AW
,Technical Executive Director
Email ID - technical@riyadh-cables.com
Website -
http://www.riyadh-cables.com/
1. 1 Page 5 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Phone - +966-6380080
Email ID - scc@saudicable.com
Website - http://www.saudicable.com
Website - http://www.southwire.com/
STERLITE ACAR, ACSR, ACSR/AW and AAAC Tests performed at: PQ Letter
INDIA Based on TS&SD Letter #
FGH, Germany 10-F001691/01-03032301 dated 19/06/2010, it is
S. No. 99/P, Madhuban Dam Road, (Dec., 2009) pre-qualified with the following condition:
Rakholi Silvassa 396230 - India
Report # H1005, WARRANTY:
Contact Person - Mr. Vivek Ananad H10006, H10007 Ten (10) years extended warranty/guarantee in
Phone - +91-97-6555-3878 and H10008 respect of defects due to design, manufacture,
Email ID - vivek.anand@sterlite.com installation & workmanship from the date of
Website - Provisional Acceptance Certificate (PAC) of the
http://www.sterlitetechnologies.com turnkey project in case of contract award or date
of delivery in case of direct material supply order.
Total = 12
CONDUCTORS, BARE
1. 2
GUY WIRE STRAND, GALVANIZED (GROUNDING) Applicable Standards: 10-TMSS-02
JOSLYN
United States
Website -
http://www.joslynhivoltage.com/
1. 2 Page 6 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
SOUTHWIRE
United States
Website - http://www.southwire.com/
TREFILEUROPE
FRANCE
Website -
http://www.mittalsteel.com/Facilities/Eu
rope/Mittal+Steel+Gandrange/Trefileuro
pe/
Total = 4
CONDUCTORS, BARE
1. 3
OVERHEAD GROUND WIRE (OGW) Applicable Standards: 10-TMSS-03
ALCOA
United States
Website -
http://www.alcoa.com/usa/en/home.as
p
1. 3 Page 7 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
ECN CG SA
SPAIN
Phone - +61-3-5232-4709
Email ID - amjad.aziz@jpowers.co.jp
Website -
http://www.jpowers.co.jp/english/inde
x.html
1. 3 Page 8 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Plant -Bahrain
RIYADH CABLES
Saudi Arabia
SAUDI CABLE
Saudi Arabia
Phone - +966-6380080
Email ID - scc@saudicable.com
Website - http://www.saudicable.com
SOUTHWIRE
United States
Website - http://www.southwire.com/
1. 3 Page 9 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
TREFILEUROPE
FRANCE
Website -
http://www.mittalsteel.com/Facilities/Eu
rope/Mittal+Steel+Gandrange/Trefileuro
pe/
Total = 9
CONDUCTORS, BARE
1. 4
OPTICAL FIBER GROUND WIRE (OPGW) Applicable Standards: 10-TMSS-04
Website - http://www.afltele.com/
AFL TELECOMMUNICATIONS GMBH Type test report for Previously Draka Comteq Germany GmbH & KG.
GERMANY OPGW ASLH-D(S)
BB 96 SMF No WARRANTY:
Monchengladbach , Germany AL4/A20SA Ten (10) years extended warranty/guarantee in
161/21-20,0 respect of defects due to design, manufacture,
Type test report for installation & workmanship from the date of
OPGW type Provisional Acceptance Certificate (PAC) of the
ASLH-D(S)bb first turnkey project in case of contract award or
48SMF (AL4/A20SA date of first delivery in case of direct material
163/20-20,0) supply order.
(Equivalent to Wolf
with 48 Fiber).
BRUGG TELECOM AG
SWITZERLAND
Website - http://www.brugg.com/
1. 4 Page 10 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
CORNING CABLES
United Kingdom
Website -
http://www.corningcablesystems.com/
DRAKA NK
FINLAND
Website - http://www.draka.com/
FUJIKURA
JAPAN
Website - http://www.ffcpg.com.my/
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
1. 4 Page 11 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
JIANGSU ZHONGTIAN TECHNOLOGY OPGW, 70kN 13.3mm, 48 Fibers Tests performed at: PQ Letter
CO.LTD (ZTT) Kinectrics Canada Based on TS&SD Letter # 10-01654-03032301
CHINA (July, 2011) Report dated June 05, 2010 and S&SD Letter
# 12-05204-1-30504401 dated February 04, 2013,
Chinanantong, China K-419311-RC0001-R it is prequalified with the following condition:
00
WARRANTY:
Ten (10) years extended warranty/guarantee in
OPGW, 120kN, 17.3mm, 48 Fibers Tests performed at: respect of defects due to design, manufacture,
Kinectrics Canada installation & workmanship from the date of
(July, 2011) Provisional Acceptance Certificate (PAC) of the
Report # first turnkey project in case of contract award or
K-419311-RC0002-R date of first delivery in case of direct material
00 supply order.
1. 4 Page 12 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
PHILLIPS FITEL
CANADA
Website - http://www.phillipsfitel.com
PIRELLI
ITALY
1. 4 Page 13 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
PRYSMIAN TELECOM Zamil Group Holding co, 6715 120 kN/24 kA 48 core, Tests performed at: PREVIOUSLY "PIRELLI"
SPAIN Commercial Div 6716 70 kN/13 kA 48 core Kinectrics Canada
www.zamilcd.com.sa (May, 2014)
Plant -Vilanova I La Geltru/Spain Phone - Report #
966-0-504-320-776 8609 120 kN/24 kA 96 core, K-419533-RC-0002-
Ctra. C-15,Km, 2-P.I. Masia D’En Notari Email - 8610 70 kN/13 kA 96 core R01
08800 Vilanova I La Geltru ( Spain) khaleds@zamilcd.com.s
a
Contact Person - Mr. Toni Nieto
Phone - +34608749306
Email ID -
Antonio.nieto@prysmiangroup.com
Website -
http://www.prysmiangroup.com
TAIHAN ELECTRIC WIRE COMPANY Taihan Electric Wire OPGW-120kN, 36 Fibers, 17.9mm Tests performed at: PQ Letter
SOUTH KOREA Co.,Ltd. Branch Al-Tube type Kinectrics Canada, Based on TS&SD letter# 09-F00730/03-03032301
P. O. box 300201,Riyadh KERI & Taihan dated 24th August 2009, it is prequalified with the
Plant -Dangjin Factory Dangjin /Republic 11372, Al-Rossais (2011) following condition:
Of Korea Building, 6th Floor Office
No. 613 - Taihan Electric WARRANTY:
180, Simin-Daero, Dongan-Gu, Wire Co.,Ltd. Branch Ten (10) years extended warranty/guarantee in
Anyangsi, Gyeonggi-Do, Korea Korea, Phone - 966) 114190227 respect of defects due to design, manufacture,
Republic Of Email - installation & workmanship from the date of
jsnam@taihan.com Provisional Acceptance Certificate (PAC) of the
Contact Person - Mr. JAI-HO SHIM first turnkey project in case of contract award or
Phone - +82) 2 316 9378 date of first delivery in case of direct material
Email ID - jhshim@taihan.com supply order , as confirmed by the manufacturer
Website - http:// through their letter no.nil, dt: 30/03/2008.
http://www.taihan.com/eng1/customer/
s 015.asp
Total = 13
CONDUCTORS, BARE
1. 5
BARE, COPPER-CLAD STEEL GROUNDING CONDUCTOR AND GROUND ROD Applicable Standards: 10-TMSS-05
1. 5 Page 14 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Nottingham WARRANTY:
Ten (10) years Extended Warranty as confirmed
Contact Person - Mark Rimmington, through Letter No. ANW/NG SA/ SEC / EW/ L01 /
Director 2016 dated 27/10/2016 shall be applicable for all
Phone - +44(0)1159271721 supplies to the Company by A. N. Wallis & Co.
Email ID - info@an-wallis.com Ltd. – UK
Website - www.an-wallis.com
COMSCOPE BIMETALS
United States
Website - http://www.fmsudafix.com/
Website -
http://www.jiwoong.co.kr/main
eng.html
LTV COPPERWELD
United States
Website -
http://www.ltv-copperweld.com/
1. 5 Page 15 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website - http://www.seico.com.sa/
Total = 7
CONDUCTORS, BARE
1. 6
HEAT-RESISTANT ALUMINUM ALLOY BARE CONDUCTORS FOR OVERHEAD LINE Applicable Standards: 10-TMSS-06
1. 6 Page 16 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
J-POWER SYSTEM CORP, Middle East Regional GAP Type & INAVR Type Conductors: Test performed at: PQ Letter
JAPAN Office GTACSR, GZTACSR and Toyoura Works Based on TS&SD letter# 09-00649-1-03032301
Mr. Amjad Abdelaziz ZTACIR/AS, XTACIR/AS (JECTEC) Nov./Dec. dated 28 March 2009 and S&SD letter no.
Plant -JAPAN-Hitachi ,General Manager 2014, Oct. 2009, 15-00017-1-30504401 dated 8th Feb 2015 it is
Amja.aziz@jpower.co.jp Jan. 2013, Mar. pre-qualified for Heat Resistant Conductors
3-13-16 Mita- Minato-Ku, Tokyo 2004, & Sep 2007 subject to the following conditions:
108-0073 , Japan
Report # WARRANTY:
Phone - +61-3-5232-4709 JTR12AY091245, Ten (10) years extended warranty in respect of
Email ID - amjad.aziz@jpowers.co.jp JTR12AY-13092, the defects due to design, manufacturing &
Website - JTR12-AY044167,JT workmanship from the date of the Provisional
http://www.jpowers.co.jp/english/inde R12-AY07980, Acceptance Certificate (PAC) of the first turnkey
x.html JTR12-AY07092, project (in case of contract award) and from the
JTR12-AY12107,JT date of first delivery in case of direct material
R12-AY09913 & supply order shall be provided as confirmed by
JTR12-Ay141633 the manufacturer through their letters #
#JLX80-15-0013 dated 5th Feb 2015 and
Type Tests JLX80-15-0022 dated March 02nd, 2015.
performed from 27th
Nov to 5th Dec 2014
at:
Japan Electric Cable
technology
Center(JECTEC) Lab
Shizuoka, Japan.
Report#
IR-2014-5001-40261
-001
1. 6 Page 17 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Total = 3
CONDUCTOR, INSULATED
2. 1
POWER CABLE, XLPE, CU OR AL, 1-CORE, 69 kV Applicable Standards: 11-TMSS-01
Website - http://www.alcatel.fr/
2. 1 Page 18 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
DEMIRER KABLO
TURKEY
Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=
Website - http://www.draka.com/
Website - http://www.ffcpg.com.my
2. 1 Page 19 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
JEDDAH CABLE CO. XLPE Cable Type tested in 2010 Based on S&SD letter# 16-06823-30504401
Saudi Arabia 1x1200mm² Report # TDT dated August 14, 2016, the manufacturer is
1002-10 prequalified for XLPE Insulated Power Cable as
Po Box 31248 , Jeddah 21497 Jeddah , , 69 kV confirming to SEC specification # 11-TMSS-01,
Saudi Arabia Rev.0, with the following condition:
Contact Person - Mr. Mohammad Said • Ten (10) years extended warranty for XLPE
Minkara Power Cable from the date of PAC of the turnkey
Phone - +966-126360770 project in case of contract award and date of
Email ID - delivery in case of direct material supply order,
sayoubi@cables.energya.com , as confirmed by the manufacturer through letter
msminkara@cables.energya.com #NIL dated August 14, 2016.
Website -
http://www.cables.energya.com
Phone - +61-3-5232-4709
Email ID - amjad.aziz@jpowers.co.jp
Website -
http://www.jpowers.co.jp/english/inde
x.html
Email ID - lang=en
Website - http://www.mkm-?
mediline.de/index.php/edv-und-softwar
e-?
entwicklung/mkm-computer-network-?
ungarn?lang=en?
2. 1 Page 20 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
SAUDI CABLE
Saudi Arabia
Phone - +966-6380080
Email ID - scc@saudicable.com
Website - http://www.saudicable.com
Website - http://
http://www.suedkabel.de/index e.htm
Total = 13
CONDUCTOR, INSULATED
2. 2
POWER CABLE, XLPE INSULATED, COPPER CONDUCTOR, SINGLE CORE, 110 TO 132 kV Applicable Standards: 11-TMSS-02
2. 2 Page 21 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
BRUGG Mass Power contracting 110 kV to 132 kV. Tests performed at: NAM. GIS termination, Transformer Termination,
SWITZERLAND Co. KEMA Outdoor termination, Cross bonding & Straight
Contact Person:Mr. Syed Netherlands Through Joints - XLPE Cables 16 Models of XLPE
5201 Brugg Switzerland,28 Ch5201 Ali Report # TDT cable
Brugg Switzerland, 0506818743 ,Phone - 3148-10 (2011)
0506818743 70851907-TDT-09-6
Contact Person - Mr. Pierre Londorf Email - 9942A
Phone - +41-56-460-3637 s.ali@mass-group.net (2009) & TIC
Email ID - londorf.pierre@brugg.com 1012-14(2014
Website - http://www.brugg.com/
DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN
2. 2 Page 22 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=
DRAKA NK
FINLAND
Website - http://www.draka.com/
FUJIKURA
JAPAN
Website - http://www.ffcpg.com.my/
2. 2 Page 23 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
JEDDAH CABLE CO. 1x1200mm2 All models type Based on TS&SD Letter #10-02784-01-03032301
Saudi Arabia (110kV & 132kV) tested at: dated October 10,2014 and S&SD Letter
KEMA Netherlands #14-04876-01-30504401 dated july 16 2014. It is
Po Box 31248 , Jeddah 21497 Jeddah , 1x2000mm2 (2010, prequalified for 132 kV , 1x2500mm2
Saudi Arabia (115kV & 132kV) 2012, 2013 & 2014) CU/XLPE/CWS/LAT/HDPE Power Cable as
Report # TIC confirming to N ational Grid Specification #
Contact Person - Mr. Mohammad Said 1x2500mm2 132kV 1065-12, TIC 11-TMSS-02 Rev.1 with the following condition
Minkara 1002-13, TDT
Phone - +966-126360770 1001-10, TIC Ten ( 10) years extended wararanty for XLPE
Email ID - 1072-12, TIC Power cable from the date of PAC of the turnkey
sayoubi@cables.energya.com , 1013-14 project in case of contract award or date of
msminkara@cables.energya.com delivery in case of direct material supply order.
Website - This was confirmed in writing by Jeddah cable.
http://www.cables.energya.com Co. through letter #nil dated 26th June 2006.
Phone - +61-3-5232-4709
Email ID - amjad.aziz@jpowers.co.jp
Website -
http://www.jpowers.co.jp/english/inde
x.html
LS PREVIOUSLY LG;
SOUTH KOREA
Website - http://www.lscable.com/
2. 2 Page 24 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
RIYADH CABLES 110 TO 132kV, Tests performed at: Based on S&SD letter # 16-04560-30504401
Saudi Arabia 1x2500mm2 KEMA dated June 12, 2016, the manufacturer is
Netherlands (Jan. prequalified for XLPE cable 132KV,as
P.O. Box 26862- Riyadh, 11496 Riyadh 2014) conforming to National Grid SA specification #
, Saudi Arabia Report # TIC 11-TMSS-02, Rev.01.
1489-13
Contact Person - Dr. Nabiah Al-Saati
,Technical Executive Director Type /Special tests
Email ID - technical@riyadh-cables.com were successfully
Website - conducted along
http://www.riyadh-cables.com/ with following cable
accessories from
Brugg Cables at
KINECTRIC –
Canada. Report No:
K-423363
RC-0000-R0 & SGS
Inspection report #
01.14189 Rev.0 &
KEMA Tests on Joint
Outer Protection
–Extract of Report
TIC
1012-14:
I. Porcelain Insulated
Outdoor Sealing End
from Brugg Cables -
Type # TE 1.170-01
II. SF6 Gas Insulated
Sealing End from
Brugg Cables - Type
#
TF 1.170-12
III. Insulating Joint
from Brugg Cables -
Type # MPAP
1.145-33
2. 2 Page 25 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website - http://
http://www.suedkabel.de/index e.htm
TAIHAN ELECTRIC WIRE COMPANY Taihan Electric Wire Tests performed at:
SOUTH KOREA Co.,Ltd. KEMA
P. O. box 300201,Riyadh Netherlands (Mar
Plant -Dangjin Factory Dangjin /Republic 11372, Al-Rossais 1995, Dec
Of Korea Building, 6th Floor Office 2009 & June 2013)
No. 613 -
180, Simin-Daero, Dongan-Gu, Phone - 966) 114190227
Anyangsi, Gyeonggi-Do, Korea Korea, Email -
Republic Of jsnam@taihan.com
Total = 15
CONDUCTOR, INSULATED
2. 3
POWER CABLE, XLPE INSULATED, COPPER CONDUCTOR, SINGLE CORE, 230 kV Applicable Standards: 11-TMSS-02
2. 3 Page 26 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
BRUGG CONDITION:
SWITZERLAND All type/design and routine/sample tests shall be
conducted at SEC approved independent
Contact Person - Mr. Pierre Londorf laboratory in presence of representative of 3rd
Phone - +41-56-460-3637 party inspection agency & three engineers of
Email ID - londorf.pierre@brugg.com SEC for first contract.
Website - http://www.brugg.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN
DEMIRER KABLO
TURKEY
Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=
FUJIKURA
JAPAN
Website - http://www.ffcpg.com.my/
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
2. 3 Page 27 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Phone - +61-3-5232-4709
Email ID - amjad.aziz@jpowers.co.jp
Website -
http://www.jpowers.co.jp/english/inde
x.html
Website - http://
http://www.suedkabel.de/index e.htm
2. 3 Page 28 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
TAIHAN ELECTRIC WIRE COMPANY Taihan Electric Wire Tests performed at: WARRANTY:
SOUTH KOREA Co.,Ltd. KEMA Ten (10) years extended warranty/guarantee in
P. O. box 300201,Riyadh Netherlands respect of defects due to design, manufacture,
Plant -Dangjin Factory Dangjin /Republic 11372, Al-Rossais installation & workmanship from the date of
Of Korea Building, 6th Floor Office Provisional Acceptance Certificate (PAC) of the
No. 613 - first turnkey project in case of contract award or
180, Simin-Daero, Dongan-Gu, Phone - 966) 114190227 date of first delivery in case of direct material
Anyangsi, Gyeonggi-Do, Korea Korea, Email - supply order.
Republic Of jsnam@taihan.com
Total = 10
CONDUCTOR, INSULATED
2. 4
POWER CABLE, XLPE INSULATED, COPPER CONDUCTOR, SINGLE CORE 380 kV Applicable Standards: 11-TMSS-02
BRUGG CONDITION:
SWITZERLAND All type/design and routine/sample tests shall be
conducted at SEC approved independent
5201 Brugg Switzerland,28 Ch5201 laboratory in presence of representative of 3rd
Brugg Switzerland, party inspection agency & three engineers of
SEC for first contract.
Contact Person - Mr. Pierre Londorf
Phone - +41-56-460-3637 WARRANTY:
Email ID - londorf.pierre@brugg.com Ten (10) years extended warranty/guarantee in
Website - http://www.brugg.com/ respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN
2. 4 Page 29 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=
ILJIN ELECTRIC CO. LTD. 380kV XLPE Cable 1x2500mm² Based on S&SD letter# 16-2299-02-30504401
SOUTH KOREA CU/XLPE/LEAD/HDPE & Accessories dated May 02, 2016, it is prequalified for380kV
[Outdoor XLPE Cable 1x2500mm² CU/XLPE/LEAD/HDPE &
Plant -Hongseong, South Korea Termination-Porcelain Type APS(CE-W) Accessories [Outdoor Termination-Porcelain
420-S, Outdoor Type APS(CE-W) 420-S, Outdoor
905-17, Mannyeon-ro, Hwaseong-si, Termination-Porcelain Type Termination-Porcelain Type APWA(CE-W) 420-S,
Gyeonggi, KOREA APWA(CE-W) 420-S, Dry Dry Type GIS Termination GDEO(CE-W) 420S,
Type GIS Termination GDEO(CE-W) Premold Insulation Joint Type MIDFD(CE-W)
Contact Person - Mr. Jeong Kyung Woo 420S, Premold Insulation 420-S, Premold Straight Joint Type MNDFD(CE-W)
, Mr. Jaeho Kim Joint Type MIDFD(CE-W) 420-S, 420-S] as conforming to National Grid SA Material
Phone - +82-2-707-9161 Premold Straight Joint Type Specification 11-TMSS-02, Rev 01 with the
Contact Person Email ID - MNDFD(CE-W) 420-S] following conditions:
jkwoo@iljin.co.kr , jaeho.kim@iljin.co.kr
Website - http://www.iljinelectric.co.kr • Ten (10) years extended warranty from the
date of PAC of the turnkey project in case of
contract award and date of delivery in case of
direct material supply order, as confirmed by the
manufacturer through letter # ILJHC-160412A
dated 12/04/2016.
Phone - +61-3-5232-4709
Email ID - amjad.aziz@jpowers.co.jp
Website -
http://www.jpowers.co.jp/english/inde
x.html
2. 4 Page 30 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
2. 4 Page 31 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website - http://
http://www.suedkabel.de/index e.htm
TAIHAN ELECTRIC WIRE COMPANY Taihan Electric Wire 1x2500mm2 Tests performed at: PQ Letter
SOUTH KOREA Co.,Ltd. CWS Type, KEMA Based on S&SD letter # 14-08139-01-30504401
P. O. box 300201,Riyadh 380 kV with the following drawing Netherlands (Jan. dated: January 07, 2015, the manufacturer is
Plant -Dangjin Factory Dangjin /Republic 11372, Al-Rossais numbers: 2014 to prequalified to supply 380kV 1x2500mm2 CWS
Of Korea Building, 6th Floor Office May, 2014) Type power cables & accessories:
No. 613 - - Power cable: Report # TIC
180, Simin-Daero, Dongan-Gu, Phone - 966) 114190227 TXCCD-3802500-130501. 3094-14 WARRANTY:
Anyangsi, Gyeonggi-Do, Korea Korea, Email - - Outdoor termination: Ten (10) years extended warranty in respect of
Republic Of jsnam@taihan.com CVC-APS-3804605N-BD (Rev. A). the defects due to design, manufacturing,
- GIS termination fluid filled type: installation and workmanship from the date of the
Contact Person - Mr. JAI-HO SHIM CVC-GWO-380-BD (Rev. Provisional Acceptance Certificate (PAC) of the
Phone - +82) 2 316 9378 A). first turnkey project (in case of contract award)
Email ID - jhshim@taihan.com - GIS termination dry type: or from the date of first delivery in case of direct
Website - http:// CVC-GWBS-380-BD (Rev. A). material supply order shall be provided as
http://www.taihan.com/eng1/customer/ - Cable joint type: CVC-MIP-380-BD confirmed by the manufacturer through their
s 015.asp (Rev. A). letter # Nil dated September 02, 2014.
- Cable joint (A type) with screen
interruption type
CVC-MIP-380-R1-BD (Rev. A).
- Straight joint type CVC-MNP-380-BD
(Rev. A).
- Coffin Box (1 hole) CV-C1-380N-BD
(Rev. A).
- Coffin Box (1 hole) CV-C1-380N-BD
(Rev. A).
2. 4 Page 32 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
VISCAS FUJIKURA
JAPAN
Website - http://
http://www.viscas.com/e contact.html
Total = 11
CONDUCTOR, INSULATED
2. 5
POWER CABLE, LPOF, CU, 1-CORE, CABLE –110 kV TO 132 kV Applicable Standards: 11-TMSS-03
Website - http://www.alcatel.fr/
Website - http://
http://www.transcanadawireandcable.
com
Website - http://
http://www.daetwyler.net/e/index.htm
Website - http://www.ffcpg.com.my/
2. 5 Page 33 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
Phone - +61-3-5232-4709
Email ID - amjad.aziz@jpowers.co.jp
Website -
http://www.jpowers.co.jp/english/inde
x.html
Website - http://
http://www.bruggcables.com/index/ind
ex.cfm?page=home&sprache=de
LS CABLES PREVIOUSLY LG
SOUTH KOREA
Including Joints & Terminations
Plant -Gumi/Korea
2. 5 Page 34 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website -
http://www.nexans.com/eservice/Navi
gate.nxnavigationRef=
-10&CZ=Corporate
Website - http://
http://www.swcc.co.jp/eng/index.htm
TAIHAN ELECTRIC WIRE COMPANY Taihan Electric Wire Rating - 132kV KEMA, Netherlands Including Joints & Terminations
SOUTH KOREA Co.,Ltd. July 2000
P. O. box 300201,Riyadh
Plant -Dangjin Factory Dangjin /Republic 11372, Al-Rossais
Of Korea Building, 6th Floor Office
No. 613 -
180, Simin-Daero, Dongan-Gu, Phone - 966) 114190227
Anyangsi, Gyeonggi-Do, Korea Korea, Email -
Republic Of jsnam@taihan.com
Total = 15
2. 5 Page 35 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
CONDUCTOR, INSULATED
2. 6
POWER CABLE, LPOF, CU, 1-CORE, 230 kV Applicable Standards: 11-TMSS-03
Website - http://www.alcatel.fr/
Website - http://
http://www.transcanadawireandcable.
com
Website - http://www.ffcpg.com.my/
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
Phone - +61-3-5232-4709
Email ID - amjad.aziz@jpowers.co.jp
Website -
http://www.jpowers.co.jp/english/inde
x.html
2. 6 Page 36 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
TAIHAN ELECTRIC WIRE COMPANY Taihan Electric Wire Feb. 2006 Including Joints & Terminations.
SOUTH KOREA Co.,Ltd.
P. O. box 300201,Riyadh CONDITION:
Plant -Dangjin Factory Dangjin /Republic 11372, Al-Rossais All type/design and routine/sample tests shall be
Of Korea Building, 6th Floor Office conducted at SEC approved independent
No. 613 - laboratory in presence of representative of 3rd
180, Simin-Daero, Dongan-Gu, Phone - 966) 114190227 party inspection agency & three engineers of
Anyangsi, Gyeonggi-Do, Korea Korea, Email - SEC for first contract.
Republic Of jsnam@taihan.com
WARRANTY:
Contact Person - Mr. JAI-HO SHIM Ten (10) years extended warranty/guarantee in
Phone - +82) 2 316 9378 respect of defects due to design, manufacture,
Email ID - jhshim@taihan.com installation & workmanship from the date of
Website - http:// Provisional Acceptance Certificate (PAC) of the
http://www.taihan.com/eng1/customer/ first turnkey project in case of contract award or
s 015.asp date of first delivery in case of direct material
supply order.
Total = 9
CONDUCTOR, INSULATED
2. 7
POWER CABLE, LPOF, CU, 1-CORE,380 kV Applicable Standards: 11-TMSS-03
Website - http://www.alcatel.fr/
Website - http://
http://www.transcanadawireandcable.
com
2. 7 Page 37 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website - http://www.ffcpg.com.my/
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
Website - http://www.hitachi-?
cable.co.jp/en/index.html
Phone - +61-3-5232-4709
Email ID - amjad.aziz@jpowers.co.jp
Website -
http://www.jpowers.co.jp/english/inde
x.html
2. 7 Page 38 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
LS CABLES PREVIOUSLY LG
SOUTH KOREA
Including Joints & Terminations.
Plant -Gumi/Korea
WARRANTY:
13 F Ls Tower ,127, Ls-Ro, Ten (10) years extended warranty/guarantee in
Dongan-Gu, Anyang-Si, Gyeonggi-Do, respect of defects due to design, manufacture,
Korea installation & workmanship from the date of PAC
of the First turnkey project in case of contract
Contact Person - Jiyup Baik award or date of the First delivery in case of
Phone - +82-544697602 directmaterial supply order.
Email ID - nayuppie@lscns.com
Website - http://www.lscns.com
Website -
http://www.mitsubishi-cable.co.jp/inde
x e.html
Website - http://
http://www.swcc.co.jp/eng/index.htm
2. 7 Page 39 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
TAIHAN ELECTRIC WIRE COMPANY Taihan Electric Wire Including Joints & Terminations.
SOUTH KOREA Co.,Ltd.
P. O. box 300201,Riyadh CONDITION:
Plant -Dangjin Factory Dangjin /Republic 11372, Al-Rossais All type/design and routine/sample tests shall be
Of Korea Building, 6th Floor Office conducted at SEC approved independent
No. 613 - laboratory in presence of representative of 3rd
180, Simin-Daero, Dongan-Gu, Phone - 966) 114190227 party inspection agency & three engineers of
Anyangsi, Gyeonggi-Do, Korea Korea, Email - SEC for first contract.
Republic Of jsnam@taihan.com
WARRANTY:
Contact Person - Mr. JAI-HO SHIM Ten (10) years extended warranty/guarantee in
Phone - +82) 2 316 9378 respect of defects due to design, manufacture,
Email ID - jhshim@taihan.com installation & workmanship from the date of
Website - http:// Provisional Acceptance Certificate (PAC) of the
http://www.taihan.com/eng1/customer/ first turnkey project in case of contract award or
s 015.asp date of first delivery in case of direct material
supply order.
Total = 16
CONDUCTOR, INSULATED
2. 8
MEDIUM VOLTAGE POWER CABLE -XLPE –13.8 kV Applicable Standards: 11-TMSS-04
2. 8 Page 40 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Bahra Advance Cable Manufacture Co. (XLPE) MV Power Cable with a size MV Power Cable Based on S&SD Letter # 16-07712-1-30504401
Ltd bigger than 630 mm² with a size bigger dated October 04, 2016, it is pre-qualified for
Saudi Arabia than 630 mm² to be Insulated Conductor Cable as conforming to
supplied to National Grid SA Specification # 11-TMSS-04,
Po Box 5989 Jeddah 21432 , Saudi SEC/National Grid Rev.1 with the following conditions:
Arabia SA shall fully type
tested at an •Ten (10) years extended warranty from the date
Contact Person - Mr. Loai Taha Al-Bar, accredited of PAC of the first turnkey project (in case of
Sale Manager laboratory in the contract award) or date of first delivery (in case
Phone - +966-2-591-1115 presence of National of direct material supply order), as confirmed
Email ID - Loai.albar@bahra-cable.com Grid SA through BAHRA CABLES Co. –JEDDAH, KSA
Engineers & third letter # nil dated September 06, 2016.
party inspector.
.
2. 8 Page 41 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website - http://www.ducab.ae
LS PREVIOUSLY LG
SOUTH KOREA Including Joints & Terminations
Website - http://www.lscable.com/
2. 8 Page 42 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website -
http://www.omancables.com/
SAUDI CABLE
Saudi Arabia
Phone - +966-6380080
Email ID - scc@saudicable.com
Website - http://www.saudicable.com
2. 8 Page 43 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
TAIHAN ELECTRIC WIRE COMPANY Taihan Electric Wire KEMA, Netherlands Including Joints & Terminations
SOUTH KOREA Co.,Ltd. (Nov. 2007)
P. O. box 300201,Riyadh
Plant -Dangjin Factory Dangjin /Republic 11372, Al-Rossais
Of Korea Building, 6th Floor Office
No. 613 -
180, Simin-Daero, Dongan-Gu, Phone - 966) 114190227
Anyangsi, Gyeonggi-Do, Korea Korea, Email -
Republic Of jsnam@taihan.com
Total = 10
CONDUCTOR, INSULATED
2. 9
MEDIUM VOLTAGE POWER CABLE - XLPE , 33 & 34.5 kV Applicable Standards: 11-TMSS-04
2. 9 Page 44 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Note:
MV Power Cable beyond cable size of 630 mm2
to be supplied to National Grid SA shall be fully
type tested at an accredited laboratory in the
presence of National Grid SA Engineers & third
party inspector.
Bahra Advance Cable Manufacture Co. (XLPE) MV Power Cable with a size MV Power Cable Based on S&SD Letter # 16-07712-1-30504401
Ltd bigger than 630 mm² with a size bigger dated October 04, 2016, it is pre-qualified for
Saudi Arabia than 630 mm² to be Insulated Conductor Cable as conforming to
supplied to National Grid SA Specification #11-TMSS-04,
Po Box 5989 Jeddah 21432 , Saudi SEC/National Grid Rev.1 with the following conditions:
Arabia SA shall fully type
tested at an •Ten (10) years extended warranty from the date
Contact Person - Mr. Loai Taha Al-Bar, accredited of PAC of the first turnkey project (in case of
Sale Manager laboratory in the contract award) or date of first delivery (in case
Phone - +966-2-591-1115 presence of National of direct material supply order), as confirmed
Email ID - Loai.albar@bahra-cable.com Grid SA Engineers & through BAHRA CABLES Co. –JEDDAH, KSA
third party inspector. letter # nil dated September 06, 2016
2. 9 Page 45 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
DEMIRER KABLO
TURKEY
Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=
Website - http://www.ducab.ae
Website - http://www.ffcpg.com.my
2. 9 Page 46 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Phone - +61-3-5232-4709
Email ID - amjad.aziz@jpowers.co.jp
Website -
http://www.jpowers.co.jp/english/inde
x.html
Website - http://www.lscable.com/
Email ID - lang=en
Website - http://www.mkm-?
mediline.de/index.php/edv-und-softwar
e-?
entwicklung/mkm-computer-network-?
ungarn?lang=en?
2. 9 Page 47 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website -
http://www.omancables.com/
SAUDI CABLE
Saudi Arabia
Phone - +966-6380080
Email ID - scc@saudicable.com
Website - http://www.saudicable.com
Website - http://
http://www.swcc.co.jp/eng/index.htm
2. 9 Page 48 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
TAIHAN ELECTRIC WIRE COMPANY Taihan Electric Wire Tests performed at: Including Joints & Terminations
SOUTH KOREA Co.,Ltd. Branch KEMA,
P. O. box 300201,Riyadh Netherlands
Plant -Dangjin Factory Dangjin /Republic 11372, Al-Rossais (Dec. 1986)
Of Korea Building, 6th Floor Office
No. 613 -
180, Simin-Daero, Dongan-Gu, Phone - 966) 114190227
Anyangsi, Gyeonggi-Do, Korea Korea, Email -
Republic Of jsnam@taihan.com
Total = 16
CONDUCTOR, INSULATED
2. 10
Distributed Temperature Sensing (DTS) System for U/G Power Cable Applicable Standards: 11-TMSS-06
2. 10 Page 49 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Yokogawa Electric Corporation Yokogawa Saudi Arabia DTSX200 and DTSX3000 Yokogawa Electric PQ Letter
JAPAN Company, Saudi Corporation, Japan Based on S&SD letter # 17-02871-5-30504401
Arabia-Dhahran has successfully dated April 19,2017 , Yokogawa Electric
Plant -Japan Ibn Rushd Street, completed type tests Corporation, Japan is pre-qualified for Distributed
Dhahran Techno-Valley - on Distributed Temperature Sensing System (Type: DTSX200
Yokogawa Manufacturing Corporation Dhahran, P.O.Box 3368, Temperature and DTSX3000) as conforming to National Grid
Koufu Factory 155, Takamurocho, Al-Khobar 31952, Sensors (DTS) Type SA specification # 11-TMSS-06, with the
Kofu-City, Yamanashin 400-8558- Kingdom of Saudi Arabia DTSX200 and following conditions:
Japan +966 (13) 331 9600 DTSX3000 in
Hazem.Hassan@sa.yok presence of three WARRANTY:
Kofu ogawa.com SEC/National Grid Ten (10) years extended warranty in respect of
SA Engineers and defects due to design, manufacturing and
Contact Person - Mr. Teichi Matsumoto third party inspector workmanship from the date of PAC of the first
& Mr. Hazem A. Hassan at Independent turnkey project (in case of contract award) or
Phone - +81-55-243-0480 testing laboratory UL from the date of first delivery (in case of direct
Email ID - – Japan on 30 May material supply order), as confirmed, through
Hazem.Hassan@sa.yokogawa.com 2016 & Yokogawa their Letter No. SSD-PDZZ21-G15-25-3 dated
Contact Person Email ID - Electric Corporation 20/01/2016.
Hazem.Hassan@sa.yokogawa.com Laboratory- Japan
Website - WWW.yokogawa.co.jp during 26 to 27 May
2016.
Total = 2
CONDUCTOR, INSULATED
2. 11
DTS System Integration, Assembly and Factory Acceptance Testing (FAT) Applicable Standards:
2. 11 Page 50 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
WARRANTY
Ten (10) years extended warranty in respect of
defects due to design, manufacturing and
workmanship from the date of PAC of the first
turnkey project (in case of contract award) or
from the date of first delivery (in case of direct
material supply order), as confirmed, through
their Letter No. NIL dated 13/10/2016.
Total = 1
CONDUCTOR, INSULATED
2. 12
POWER AND/OR CONTROL CABLES COPPER OR ALUMINUM CONDUCTOR 600/1000V Applicable Standards: 11-TMSS-10
RATING
2. 12 Page 51 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Bahra Advance Cable Manufacture Co. Low Voltage Cables (1X630mm2 & KEMA –Netherland PQ Letter
Ltd 4x300 mm2 CU/XLPE/PVC-FR 1KV) & during 18th to 25th Based on S&SD letter # 15-01562-1-30504401
Saudi Arabia April 2014 & dated March 18 2015 nd S&SD letter #
KINECTRICS-Canada 16-00558-1-30504401 dated February 15 2016,
Po Box 5989 Jeddah 21432 , Saudi during 18th to 24th the manufacturer is prequalified for LV power
Arabia Aug 2014 Report cables with the following condition:
No.TIC 1018-14 for
Contact Person - Mr. Loai Taha Al-Bar, multi-core power WARRANTY:
Sale Manager cable, TIC 1019-14 Ten (10) years extended warranty/guarantee in
Phone - +966-2-591-1115 for single-core respect of defects due to design, manufacture,
Email ID - Loai.albar@bahra-cable.com power cable installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order as confirmed by the manufacturer
through their letter # (BCC/AQ/GSM/MZ dated
August 20,2011) for LV cables and letter # (
1005 / BH / 2016 dated 14/02/2016) for control
cable.
BELDEN
United States
Website - http://www.belden.com/
2. 12 Page 52 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website -
http://www.mesccables.com/
MIDDLE EAST SPECIALIZED CABLE CO. Previously JORDAN NEW CABLE COMPANY-
MESC, JORDAN-
JORDAN AMMAN [The name has been changed based on
S&SD/P&SFD letter # 14-01869-30504401 dated
Jordan March 24, 2014].
2. 12 Page 53 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #nil, dt: 21/08/2010.
SAUDI CABLE
Saudi Arabia
Phone - +966-6380080
Email ID - scc@saudicable.com
Website - http://www.saudicable.com
2. 12 Page 54 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #0580/SO/13, dt: Nov 17, 2013
Total = 12
CONDUCTOR, INSULATED
2. 13
SHIELDED INSTRUMENTATION CABLE Applicable Standards: 11-TMSS-11
2. 13 Page 55 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
ALPHA
United States
Website - http://www.alpha.com/
AT & T
United States
Website - http://www.att.com/
BELDEN
United States
Website - http://www.belden.com/
Website -
http://www.mesccables.com/
2. 13 Page 56 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no.nil, dt: 20th july, 2008.
2. 13 Page 57 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
Total = 6
CONDUCTOR, INSULATED
2. 14
EARTHING AND BONDING CABLE Applicable Standards: 11-TMSS-12
2. 14 Page 58 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Bahra Advance Cable Manufacture Co. i. Coaxial Bonding Cable 600/1000V Type test report PQ Letter
Ltd & 1800/3000V up to 500mm2 #TIC 1019-14 Based on S&SD letter # 17-00912-1-30504401
Saudi Arabia ii. Single Core Bonding Cable conducted in dated February 16, 2017, BAHRA ADVANCE
600/1000V & 1800/3000V up to 500 KEMA-Netherland. CABLE MANUFACTURE Co. Ltd –JEDDAH, KSA is
Po Box 5989 Jeddah 21432 , Saudi mm2 pre-qualified for the proposed Coaxial Bonding
Arabia iii. Earthing Cable 600/1000V & and Earthing Cable as conforming to National
1800/3000V up to 500 mm2 Grid SA specification # 11-TMSS-12 rev.0, with
Contact Person - Mr. Loai Taha Al-Bar, the following conditions:
Sale Manager
Phone - +966-2-591-1115 WARRANTY:
Email ID - Loai.albar@bahra-cable.com Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
of direct material supply order), as confirmed,
through their letter # Nil, dated October 25, 2016
shall be applicable for all proposing Coaxial,
Bonding Earthing Cable to be supplied to
SEC/National Grid SA.
Website - http://www.ffcpg.com.my/
2. 14 Page 59 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Phone - +61-3-5232-4709
Email ID - amjad.aziz@jpowers.co.jp
Website -
http://www.jpowers.co.jp/english/inde
x.html
LS CABLES PREVIOUSLY LG
SOUTH KOREA
Plant -Gumi/Korea
PIRELLI
GERMANY
Berlin , Germany
Website - http://
http://www.pirelli.com/splash/index.htm
l
2. 14 Page 60 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
RIYADH CABLES
Saudi Arabia
SAUDI CABLE
Saudi Arabia
Phone - +966-6380080
Email ID - scc@saudicable.com
Website - http://www.saudicable.com
Total = 9
CONDUCTOR FITTINGS
3. 1
LINE HARDWARE Applicable Standards: 12-TMSS-01
3. 1 Page 61 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
ALCOA
United States
Website -
http://www.alcoa.com/usa/en/home.as
p
CAROBENI
ITALY
3. 1 Page 62 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
DALEKOVOD PROIZVODNJA Innovative Systems Line Hardware up to Tests performed at: PQ Letter
CROATIA (isys) 380 kV Koncar Based on TS&SD fax # 10-01179-03032301
PO Box 60606 Riyadh Croatia, EGU Czech dated April 20, 2010, this manufacturer is
Croatia, Europe, Vukomericka 9, 10410 11555,KSA Republic, pre-qualified for Line Hardware except Spacer
Velika Gorica Zagreb , Croatia/Hrvatska Phone - ZKU, KERI & Bazet Dampers with the following conditions:
+966-11-460-8161 HV
Contact Person - Mr. Davor Maljkovic, Email - kamal@isys.sa Laboratories WARRANTY:
B.Sc. M.E. Ten (10) years extended warranty/guarantee in
Phone - +385 1 62 29 900 respect of defects due to design, manufacture,
Email ID - installation & workmanship from the date of
davor.maljkovic@dalekovod.hr Provisional Acceptance Certificate (PAC) of the
Website - first turnkey project in case of contract award or
http://www.dalekovod-proizvodnja.co date of first delivery in case of direct material
m , http://www.dalekovod.hr supply order.
3. 1 Page 63 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
HUBBELL POWER SYSTEMS, INC. Previously A B CHANCE [The name has been
United States changed based on S&SD/P&SFD letter#
14-010193-30504401 dated January 06, 2015
Plant -Columbia , United States and based on Hubbell Power System Grid Letter
# Nil dated December 18, 2014]
3. 1 Page 64 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
INDUSTRIAS ARRUTI
SPAIN
Website -
http://www.grupoarruti.com/empresa.a
sp
Website - http://www.iselfa.it/
JOSLYN
United States
Website -
http://www.joslynhivoltage.com/
MOSDORFER GMBH
AUSTRIA
3. 1 Page 65 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
NUOVA ELETTROMECCANICA SUD Dopa Co. for Trading and - Line Hardware upto 380kV Some of tests PQ Letter
S.P.A, industry - Spacer Damper type (Twin) with mutually ageed Based on S&SD letter # 15-06603-030504401
ITALY Al Nuzha District Riyadh, drawing # 8.40.N2.888 Rev.05 between National dated August 13, 2015 it is pre-qualified for
Saudi Arabia P.O Box - Spacer Damper type (Quad) with Grid SA & NES were Hardware Fittings, as conforming to National Grid
Zona Industriale - 89052 Campo 87017 Code No. 11462 drawing # 8.40.N4.864 Rev.05 conducted during SA specification12-TMSS-01 with the following
Calabro (Rc) - Italy Mr. Abdullah Alabdullah plant survey visit conditions:
Deputy General Manager from 8th to 11th
Phone - +39 0965.792.111 (6 line) - Email/ June, 2015. NOTE:
Telefax +39 0965.792.222 alabullah@dopacompany Each new design of Line Hardware & Fittings
Email ID - info@nesspa.it .com which has not been tested before, shall be type
Website - http://www.nesspa.it (+966) 11 2694609 , Type tests were tested per latest revision of 12-TMSS-01.
Mobile:(+966) 50 conducted on
4449933 spacer dampers WARRANTY:
(Nut Cracker type) Ten (10) years Extended Warranty from the date
at NES Factory Italy of PAC of the first turnkey project in case of
and Demont contract award or date of first delivery in case of
Laboratory, Italy direct material supply order shall be applicable for
from 24th July to the Line Hardware to be supplied to SEC/National
28th July, 2016 with Grid SA, as confirmed through letter # Rome,
Test Report No. TR dated 14.11.2014.
SPAT 16/024, dt:
July, 2016
Werkstrasse 7
6102 Malters
Schweiz
3. 1 Page 66 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
PREFORMED LINE PRODUCTS (PLP) M/s Al Abdulkarim - AGS Suspension Clamp & Spacer Type tests PQ Letter
United Kingdom Holding Co. Riyadh Damper(Twin/Quad) up to 380 kV performed during Based on S&SD letter # 15-09419-1-30504401
Riyadh KSA - Spacer Dampers type (Quad) with plant survey visit dated November 18, 2015, it is pre-qualified for
East Portway, Andover, Hampshire drawing # SDNCU 8044527V Rev. E from 08th to 11th AGS Suspension Clamp & Spacer Damper
Sp10 3Lh England September 2015 at (Twin/Quad) up to 380KV as conforming to
pip@preformed-gb.com Preformed Line National Grid SA specification # 12-TMSS-01.
Product Lab
Contact Person - Mr. Mohamed Atif and Hampshire, England WARRANTY:
Mr. Stephen (Report Ten (10) years extended warranty from the date
Email ID - alahmama@naizak.com, #TR(GB)No:3060) , of PAC of the first turnkey project in case of
ttaljaard@preformed-gb.com # TR- 3061 Rev.2) & contract award or date of first delivery in case of
alshihzm@akh.com.sa 8730/VNL. direct material supply order.
Website - http://www.preformed.com
Type tests were
conducted on
spacer dampers
(Nut Cracker type)
at PLP (GB) Ltd. ,
ANDOVER UK, from
31 Oct 2016,to 1st
Nov 2016.with test
report No. TR(GB)
No. 3314-E dated
1st Nov 2016 ,TR
(GB) No. 3312-E
dated 31 Oct 2016
and TR(GB) No.
3313-E dated 31 Oct
2016.
3. 1 Page 67 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
SA RA ENERGY, CONSTRUCTION, Line Hardware up to 380kV & Tests performed at: Based on S&SD letter# 14-09052-01-30504401
TRADE AND INDUSTRY CO. INC. Twin Spacer Dampers up to 132kV Veiki-VNL Lab. dated 11th December 2014 ,TS&SD fax #
TURKEY Budapest, Hungary 09-00087-03032301 dated 11/01/2009
(Corona/RIV, Power pre-Qualified for Line Hardware up to 380kV and
Plant -Polatli (Ankara) & Adana Arc & Tensile Twin Space Damper up to 132kV with the
(Aadna), Turkey Strength with following conditions:
4-bundle ACAR &
2-bundle ACSR/AW
Conductors WARRANTY:
(Dec. 2012 & April, Ten (10) years extended warranty/guarantee in
2013) respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order
SICAMEX
FRANCE
Website - http://
http://www.sicame.com/HTML
FR/filiales sicamex.htm
Total = 17
CONDUCTOR FITTINGS
3. 2
COMPRESSION TYPE CONNECTORS FOR OVERHEAD TRANSMISSION LINES Applicable Standards: 12-TMSS-02
3. 2 Page 68 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
ALCOA
United States
Website -
http://www.alcoa.com/usa/en/home.as
p
BURNDY
United States
Website -
http://portal.fciconnect.com/portal/page/
portal/FcicntPublic/BurndyWeldMenu
CAROBENI
ITALY
3. 2 Page 69 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
ELASTIMOLD
United States
Website -
http://www-public.tnb.com/ps/util/index
.cgia=elastimold
HOMAC
United States
Website - http://www.homac.com/
INDUSTRIAS ARRUTI
SPAIN
Website -
http://www.grupoarruti.com/empresa.a
sp
3. 2 Page 70 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website - http://www.iselfa.it/
MOSDORFER
AUSTRIA
3. 2 Page 71 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
NUOVA ELETTROMECCANICA SUD Dopa Co. for Trading and Overhead Line Compression type PQ Letter
S.P.A, industry connectors Based on S&SD letter # 15-06603-030504401
ITALY Al Nuzha District Riyadh, dated August 13, 2015 it is pre-qualified for
Saudi Arabia P.O Box Overhead line compression type Connectors, as
Zona Industriale - 89052 Campo 87017 Code No. 11462 conforming to National Grid SA specifications #
Calabro (Rc) - Italy Mr. Abdullah Alabdullah 12-TMSS-02
Deputy General Manager
Phone - +39 0965.792.111 (6 line) - Email/ Note:
Telefax +39 0965.792.222 alabullah@dopacompany Each new design of Overhead Line Compression
Email ID - info@nesspa.it .com type Connectors which has not been tested,
Website - http://www.nesspa.it (+966) 11 2694609 shall be type tested as
,Mobile:(+966) 50 per latest revision of 12-TMSS-02.
4449933
WARRANTY:
Ten (10) years Extended Warranty from the date
of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order shall be applicable for
the Compression type Connectors, to be supplied
to SEC/National Grid SA as confirmed through
letter # Nil dated 14.11.2014.
Werkstrasse 7
6102 Malters
Schweiz
3. 2 Page 72 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
SICAMEX
FRANCE
Website - http://
http://www.sicame.com/HTML
FR/filiales sicamex.htm
Website - http://www.smci-fc.fr/
Total = 17
3. 2 Page 73 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
CONDUCTOR FITTINGS
3. 3
OBSTRUCTION MARKERS AND WARNING LIGHTS Applicable Standards: 12-TMSS-03
Website -
http://www.bpsarabia.com.sa/
DERVAUX
FRANCE
Website -
http://www.dervaux-distribution.fr/
OBSTA
FRANCE
Website - http://www.obsta.com
P&R TECHNOLOGIES
United States
Website - http://www.pr-tech.com/
Website - http://www.pfisterer.com/
Website - http://www.smci-fc.fr/
Website -
http://www.tanawiremarker.com/
3. 3 Page 74 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Total = 8
CONDUCTOR FITTINGS
3. 4
Splice & Termination Kits for Power Cable up to 132 KV Applicable Standards: 12-TMSS-10
ABB
SWITZERLAND
3. 4 Page 75 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
BRUGG CABLE Sand World Trading 1. Outdoor Termination: Tests performed at:
SWITZERLAND Sayd Ali ,POBox 2971, Model Name : TF1.170-11 KEMA, Netherlands
Dammam 31461, Saudi Size : Up to 2000 mm² (2006/2014)
Website - Arabia Drawing # : S1625-4
http://www.bruggcables.com/index/ind Phone - T +966 13 Rating: 170kV
ex.cfmsprache=en 8462336
Email - 2. GIS Termination (Dry Type):
s.ali@mass-group.net Model Name : TFD1.170-11
Size : Up to 2500 mm²
Drawing # : S1767-4
Rating: 170kV
6. Transformer Termination:
Model Name : TF1.170-12
Size : Up to 2500 mm²
Drawing # : S1928-4
Rating: 170kV
3. 4 Page 76 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Rating: 145kV
8. Transformer Termination:
Model Name : TT1.170-11
Size : Up to 2500 mm²
Rating: 170kV
9. Transformer Termination:
Model Name : TT1.170-12
Size : Up to 2500 mm²
Rating: 170kV
3. 4 Page 77 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN
DAITWEILER
United Kingdom
Website - http://www.duttweiler.de/
DRAKA NK
FINLAND
Website - http://www.draka.com/
3. 4 Page 78 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website - http://www.ffcpg.com.my/
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
Phone - +61-3-5232-4709
Email ID - amjad.aziz@jpowers.co.jp
Website -
http://www.jpowers.co.jp/english/inde
x.html
3. 4 Page 79 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
3. 4 Page 80 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
3. Transformer Termination:
Model Name : SOA 1.145
Rating: 145kV
9. Transformer Termination
(Fluid-Filled):
Model Name : STY1.145
Rating: 145kV
3. 4 Page 81 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
NKT (COLOGNE PLANT)NKT CABLES METS Riyadh 1. Outdoor Termination: Type test witnessed PQ Letter
GROUP Mr. Won Koo Kown Model Name : FEV 170-P during 03rd-7th Based on S&SD letter # 15-05202-01-30504401
GERMANY General Manager Size : Up to 2500 mm² November 2014 & 8 dated
,wkkwon@mets.com.sa Drawing # : 3. 7 5056-04 August,2014 and 14 September 15, 2015, it is pre-qualified as per
Düsseldorfer Strasse 400 Chempark nelson@mets.com.sa Rev: 1 July 2015. KEMA 12-TMSS-10.
51061 Cologne Germany Rating: 170kV Nederland
Test Report WARRANTY:
Phone - +49-0-221-6-760 2. GIS Termination: No1211-15 Ten (10) Extended Warranty/Guarantee for the
Email ID - info@nktcables.com , Model Name : SEV 170 proposed 132 kV cables accessories shall be
saud.khalid@nktcable.com Size : Up to 2500 mm² provided in respect of the defectsdue to design,
Website - http://www.nktcable.com Drawing # : 3. 7 0264-01 manufacturing, installation and workmanship from
Rev: 1 the date of Provisional Acceptance Certificate
Rating: 170kV (PAC) of the project (in case of contract award)
and from the date of delivery for the direct
3. Transformer Termination: material supply order as confirmed through the
Model Name : TEV 170 manufacturer letter # nil dated June 04, 2013.
Size : Up to 2500 mm²
Drawing # : 3. 7 0263-01
Rev: 1
Rating: 170kV
Drawing # : 3. 7 8122-01
Rating: 145kV
3. 4 Page 82 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
4. GIS Termination:
Model Name : ESG 145-V
Size : Up to 2500 mm²
Drawing # : PRO2225
Rev: 5
Rating: 145kV
5. GIS Termination:
Model Name : ESG145-V
Size : Up to 2000 mm²
Drawing # : PRO2236Rev: 6
Rating: 145kV
6. GIS Termination:
Model Name : ESG 170-V
Size : Up to 2000 mm²
Drawing # : PR02227
Rev: 5
Rating: 170kV
7. Transformer Termination:
Model Name : ESU-123-V
Size : Up to 2500 mm²
Rating: 123 kV
3. 4 Page 83 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
8. Transformer Termination:
Model Name : ESU-145-V
Size : Up to 2500 mm²
Rating: 145 kV
3. 4 Page 84 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
3. 4 Page 85 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
3. 4 Page 86 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
PIRELLI
GERMANY
Berlin , Germany
Website - http://
http://www.pirelli.com/splash/index.htm
l
RAYCHEM, GERMANY / TE
CONNECTIVITY
GERMANY
Website - http://www.raychem.com/
3. 4 Page 87 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
3. Outdoor Termination:
Model Name : EHFV123
Rating: 123kV
5. GIS Termination:
Model Name : EHSDV 123/145/170
Size : 1600-2500 mm2
Drawing # : 0.360.06.0a
Rev: 0
Rating: 123kV
6. Outdoor Termination:
Model Name : EHFV 123/145/170
Size : Up to 2500 mm²
Drawing # : 0.36.72.13A
Rev: 2
Rating: 123kV
8. Transformer Termination:
Model Name : EHTV 123/145/170
Size : 185-1400 mm2
Drawing # : 0.360.85.0a
3. 4 Page 88 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Rev: 5
Rating: 123kV
3. 4 Page 89 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
4. GIS Termination:
Model Name : CVC-GWO-110-BD
Size : Up to 2500 mm²
Rev: A
Rating: 123kV
5. GIS Termination:
Model Name : CVC-GWO-132-BD
Rating: 145kV
6. Outdoor Termination:
Model Name : AMP-145
Rating: 145kV
7. Outdoor Termination:
Model Name : CVC-APS-1322000A-BD
Rating: 145kV
8. Outdoor Termination:
Model Name : CVC-APS-1322410A-BD
Size : Up to 2500 mm²
3. 4 Page 90 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Rev: A
Rating: 145kV
3. 4 Page 91 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
3. 4 Page 92 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Rating: 145kV
3. 4 Page 93 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Total = 18
CONDUCTOR FITTINGS
3. 5
Splice & Termination Kits for Power Cable up to 230 KV Applicable Standards: 12-TMSS-10
ABB AG
GERMANY
BRUGG CONDITION:
SWITZERLAND All type/design and routine/sample tests shall be
conducted at SEC approved independent
Contact Person - Mr. Pierre Londorf laboratory in presence of representative of 3rd
Phone - +41-56-460-3637 party inspection agency & three engineers of
Email ID - londorf.pierre@brugg.com SEC for first contract.
Website - http://www.brugg.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
3. 5 Page 94 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN
FUJIKURA
JAPAN
Website - http://www.ffcpg.com.my/
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
Phone - +61-3-5232-4709
Email ID - amjad.aziz@jpowers.co.jp
Website -
http://www.jpowers.co.jp/english/inde
x.html
Berlin , Germany
3. 5 Page 95 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Website - http://
http://www.suedkabel.de/index e.htm
TAIHAN ELECTRIC WIRE COMPANY Taihan Electric Wire 230 kV Tests performed at: WARRANTY:
SOUTH KOREA Co.,Ltd. Branch KEMA Ten (10) years extended warranty/guarantee in
P. O. box 300201,Riyadh Netherlands respect of defects due to design, manufacture,
Plant -Dangjin Factory Dangjin /Republic 11372, Al-Rossais installation & workmanship from the date of
Of Korea Building, 6th Floor Office Provisional Acceptance Certificate (PAC) of the
No. 613 - Taihan Electric first turnkey project in case of contract award or
180, Simin-Daero, Dongan-Gu, Wire Co.,Ltd. Branch date of first delivery in case of direct material
Anyangsi, Gyeonggi-Do, Korea Korea, Phone - 966) 114190227 supply order.
Republic Of Email -
jsnam@taihan.com
Contact Person - Mr. JAI-HO SHIM
Phone - +82) 2 316 9378
Email ID - jhshim@taihan.com
Website - http://
http://www.taihan.com/eng1/customer/
s 015.asp
Total = 10
CONDUCTOR FITTINGS
3. 6
Splice & Termination Kits for Power Cable up to 380 KV Applicable Standards: 12-TMSS-10
3. 6 Page 96 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
BRUGG CONDITION:
SWITZERLAND All type/design and routine/sample tests shall be
conducted at SEC approved independent
5201 Brugg Switzerland,28 Ch5201 laboratory in presence of representative of 3rd
Brugg Switzerland, party inspection agency & three engineers of
SEC for first contract.
Contact Person - Mr. Pierre Londorf
Phone - +41-56-460-3637 WARRANTY:
Email ID - londorf.pierre@brugg.com Ten (10) years warranty in respect of defects
Website - http://www.brugg.com/ extended warranty/guarantee in respect of
defects due to design, manufacture, installation &
workmanship from the date of Provisional
Acceptance Certificate (PAC) of the first turnkey
project in case of contract award or date of first
delivery in case of direct material supply order.
DAINICHI-NIPPON CABLES
(MITSUBISHI)
JAPAN
3. 6 Page 97 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
Phone - +61-3-5232-4709
Email ID - amjad.aziz@jpowers.co.jp
Website -
http://www.jpowers.co.jp/english/inde
x.html
LS CABLES & SYSTEMS LTD. 380 kV cable Tests performed at PREVIOUSLY LG;
SOUTH KOREA 1. Outdoor Termination KEMA
1x2500 mm2, CU/XLPE/LEAD/PE Netherlands (Aug, PQ Letter
Contact Person - Mr. H.S.JO (General a. Model Name: UEMA40Q004, 2014 to Based on S&SD letter # 15-3193-30504401 dated
Manager) Mr. Young Min Seo b. Model Name: UMEMA40Q004 from Dec, 2014) May 03, 2015, the manufacturer is prequalified to
Email ID - symsky@iscns.com PPC insulators (Germany). Test Report Nos. supply the Power Cables & Accessories with the
Website - http://www.lscable.com/ ? 1066-14 & TIC specified designations only:
2. Transformer Termination 1564-14
a. Model Name: WC-114022 with WARRANTY:
Drawing # WC-114022 rev. 00 Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
3. GIS Termination (Dry Type) installation & workmanship from the date of
a. Model Name: UEPG40Q001 with Provisional Acceptance Certificate (PAC) of the
Drawing # UEPG40Q001 rev. 00 first turnkey project in case of contract award or
date of first delivery in case of direct material
4. Cross Bonding Joint supply order.
a. Model Name: UEMK40Q002 with
Drawing # UEMK40Q002 rev. 00
3. 6 Page 98 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
PIRELLI
GERMANY
Berlin , Germany
Website - http://
http://www.pirelli.com/splash/index.htm
l
Website - http://
http://www.suedkabel.de/index e.htm
3. 6 Page 99 of 554
SER. MATERIAL/ MANUFACTURER NAME, NAME OF AUTHORIZED LOCAL TYPE/MODEL AND RATING TYPE TESTS REMARKS/OBSERVATIONS (NGSA
EQUIPMENT PREQUALIFIED PLANT, REPRESENTATIVE DETAILS APPROVAL LETTER,EXTENDED
DESCRIPTION LOCATION,CITY/COUNTRY AND /VENDOR (IF ANY) (DATE,TEST WARRANTY)
COMPLETE ADDRESS P.O.B., STREET ADDRESS, LABORATORY,
#, WEBSITE, TELEPHONE & E-MAIL NAME,TELEPHONE, LOCATION AND
ETC. AND NAME OF AUTHORIZED
TAIHAN ELECTRIC WIRE COMPANY Taihan Electric Wire 380 kV Tests performed at: PQ Letter
SOUTH KOREA Co.,Ltd. Branch 1x2500mm2 KEMA Based on S&SD letter # 14-08139-01-30504401
P. O. box 300201,Riyadh Netherlands (Jan. dt: January 07, 2015, the manufacturer is
Plant -Dangjin Factory Dangjin /Republic 11372, Al-Rossais 1. Outdoor Termination 2014 to prequalified to supply power cables &
Of Korea Building, 6th Floor Office a. Model Name: May, 2014) accessories with the specified designations only:
No. 613 - Taihan Electric CVC-APS-3804605N-BD rev. A Report # TIC
180, Simin-Daero, Dongan-Gu, Wire Co.,Ltd. Branch 3094-14 WARRANTY:
Anyangsi, Gyeonggi-Do, Korea Korea, Phone - 966) 114190227 2. GIS termination (Fluid-Filled ) Ten (10) years extended warranty in respect of
Republic Of Email - a. Model Name: CVC-GWO-380-BD rev. the defects due to design, manufacturing,
jsnam@taihan.com A installation and workmanship from the date of the
Contact Person - Mr. JAI-HO SHIM Provisional Acceptance Certificate (PAC) of the
Phone - +82) 2 316 9378 3. GIS termination (Dry Type) first turnkey project (in case of contract award)
Email ID - jhshim@taihan.com a. Model Name: CVC-GWBS-380-BD or from the date of first delivery in case of direct
Website - http:// rev. A material supply order shall be provided as
http://www.taihan.com/eng1/customer/ confirmed by the manufacturer through their
s 015.asp 4. Transformer Termination letter # Nil dated September 02, 2014.
a. Model Name: CVC-OWO-380-BD
with Drawing # WD-433884 rev. 01
VISCAS FUJIKURA
JAPAN
Website - http://
http://www.viscas.com/e contact.html
Total = 11
CONDUCTOR FITTINGS
3. 7
LINK BOXES FOR GROUNDING OF U/G POWER CABLE Applicable Standards: 12-TMSS-11
AARTCO UP TO 230KV.
Saudi Arabia
Website - http://www.aartco.com.sa/
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
AL SHAHRANI EST.
Saudi Arabia
Website - http://www.alshahranig.com
DEMIRER KABLO
TURKEY
Website - ?http://
http://www.masskablo.com/about us
co?mpany.asp?md=
EM ELEKTRIK MALZERMELERI Gulf Trade Link Est. Type tests were PQ Letter
YUKLENIM SAN.TIC. A.S. PO Box 20362 Riyadh conducted in KEMA Based on S&SD letter # 15-07259-2-30504401 dt:
TURKEY 11455 Netherland in Sept17, 2015, the manufacturer is prequalified to
Mr. Ahmed Qazi presence of supply Link box, Up to 132kV with Stainless Steel
(Itosb)No:25 34959 Tepeören-Tuzla Commercial Manager SEC/National Grid Material as conforming to National Grid SA
Istanbul / Turkey ahmed@gradelink.com SA Engineers during specification # 12-TMSS-11
1st to 5th June
Phone - +90 216 593 37 15 & 2015.This Test was WARRANTY:
19(Pbx),Fax: +90 216 593 37 21 repeated on this link Ten (10) years extended warranty in respect of
Email ID - info@emelec.com.str box during 30th the defects due to design, manufacturing,
June and 1st July installation and workmanship from the date of the
2015 in DNV-GL . Provisional Acceptance Certificate (PAC) of the
Type Test Report project (in case of contract award) and from the
No. 1206-15 VI, date of delivery in case of direct material supply
1207-15 VI, 1208-15 order shall be provided as confirmed by the
VI, 1209-15 VI manufacturer through their extended warranty
letter attached with the letter #EM-011-/031 dated
January 25, 2012.
Website - http://www.ffcpg.com.my/
Phone - +61-3-5232-4709
Email ID - amjad.aziz@jpowers.co.jp
Website -
http://www.jpowers.co.jp/english/inde
x.html
LS CABLES PREVIOUSLY LG
SOUTH KOREA
Plant -Gumi/Korea
PIRELLI
GERMANY
Berlin , Germany
Website - http://
http://www.pirelli.com/splash/index.htm
l
STEINER
GERMANY
Website -
http://www.steiner-binoculars.com/ind
ex.html
Total = 13
INSULATORS
4. 1
INSULATORS, STATION POST TYPE, PORCELAIN, INDOOR/OUTDOOR, 69 KV THROUGH 380 Applicable Standards: 15-TMSS-01
KV
Rating: 380kV
Models: 7.035478, 7.035471
Website - http://www.lappusa.com/
Website - http://www.wsi.com/
Total = 6
INSULATORS
4. 2
INSULATORS, PORCELAIN SUSPENSION TYPE UP TO 380kV Applicable Standards: 15-TMSS-02
NGK INSULATORS LTD Mitsubishi Corporation Porcelain Fog type Disc Insulator Tests performed:
JAPAN 5h Floor tower A4, Models: May 25-June 01,
Granada Business park 132 kV 111KN 2011, March 01-13,
Plant -Aichi Japan, Exit 9 CA-825MW 2007, and March
Phone - CA-825EZ, 20-22, 2007
Contact Person - Mr. H. Nakane & Mr. Y +966-11-511-7516
Ogawa Email: hashim.a.ibrahim@ 132 kV 160KN Report # 110023T,
Email ID - n111ex@ngk.co.jp & mitsubishicorp.com CA-839MX 110024T,
ogawa@ngk.co.jp CA-839EX,
Website - http://www.ngk.com/ 070011T, 070012T,
380 kV 160 KN 120025T,
CA833MZ
CA833EX, 080027T, 080030T,
080031T
380 kV 210 KN
CA845MY 110021T, 110022T,
CA-845 EZ,
380 kV,160 KN
CA-635MZ
CA-635EZ
CA-635EW
380 kV,210 KN
CA640MY, CA640EY
Total = 1
INSULATORS
4. 3
INSULATORS, GLASS, SUSPENSION TYPE TYPE UP TO 380kV Applicable Standards: 15-TMSS-02
VERESCENCE La Graja SL Innovative Systems Toughened Glass (Aero form/Fog) Tests performed at: PQ Letter
SPAIN (isys) 120kN, 160KN, and 210kN EGU & ZKU labs Based on S&SD letter# 13-07206-01-30504401
PO Box 60606 riyadh Models: (Czech republic). dated November 09, 2013, it is pre-qualified for
Sgd La Granja Vidrieria, S. L. Paseo Del 11555 KSA E-120DZ-146 (March 4-15, 2013) Glass insulators with the following condition:
Pocillo S/N 40100 B Granja De San Phone - E-160GDZ-146
Ildefonso (Segovia) Spain Segovia , +966-11-460-8161 E-210GDZ-170 Report # 9886/A/13, WARRANTY:
Spain Email - kamal@isys.sa E-120PPZ-146 9886/B/12, Ten (10) years extended warranty/guarantee in
E-160ZP-156 9886/D/13, and respect of defects due to design, manufacture,
Contact Person - Mr. Elias Py Rodriguez E-210PZ-170 13/044 installation & workmanship from the date of
Phone - +(+34) 917707516 Provisional Acceptance Certificate (PAC) of the
Email ID - insulators@sgdgroup. corn first turnkey project in case of contract award or
Website - date of first delivery in case of direct material
http://www.sgdinsulators.com supply order, as confirmed by the manufacturer
thru letter #nil, dt: Nov 08, 2012.
Total = 2
INSULATORS
4. 4
INSULATORS, PORCELAIN HORIZONTAL LINE POST TYPE Applicable Standards: 15-TMSS-03
Total = 3
INSULATORS
4. 5
INSULATORS, PORCELAIN, LONG ROD TYPE UP TO 380 kV Applicable Standards: 15-TMSS-04
Type tests
performed in EGU
Test Report #
10129/A/14 dated
July, 2014
132kV. 160 kN
Insulatorss were
type tested in Lapp
lab. With test report
nos.21/10, 40/13
132kV, 120 KN
CA45501A
CA45503A
CA45514A
CA45516A
CA45502A
CA45504A
CA45515A
CA45517A
Zapel SA Innovative Systems 132kV Long Rod Porcelain Insulators Type test performed PQ Letter:
Poland (ISys) 160KN at KEMA Laboratory Based on S&SD letter # 17-04625-01-030504401
P.O.Box 60606, Riyadh Dwg. # 032Z-15 & 033Z-15 Prague dated June 07,2017, Zapel SA Poland is
Plant -Poland 11555 120KN Report# 5024-17 & pre-qualified for 132kV Long Rod Porcelain
Dwg. # 158Z-15 & 159Z-15 5025-17 dated Insulators as conforming to National Grid SA
Zapel SA Techniczna 1 36-40, local Contact Person: 10-03-17 specification # 15-TMSS-04, with the following
Boguchwala, Poland Mr. Kamal Al Muhanna Drawing # 032Z-15 conditions:
Mobil# +966 -505491067 & 033Z-15
Contact Person - Mr. Wojciech Sztaba +966 (11) 4608160, WARRANTY:
Phone - +48178720100 +966 (11) 4608161 Type test performed • Ten (10) years extended warranty from the
Email ID - zapel@zapel.com.pl kamal@isys.sa at EGU HV date of PAC of the first turnkey project (in case
Contact Person Email ID - laboratory Praha of contract award) or date of first delivery (in
Wojciech.Sztaba@zapel.com.pl dated 10.03.2017 case of direct material supply order), as
Website - confirmed, through their Letter No. NIL dated
http://www.zapel.com.pl/en/products/i Report #10573/A/17 30/05/2016 shall be applicable for the equipment
nsulators/ Report #10573/B/17 to be supplied to SEC/National Grid SA.
Report #10573/C/17
Report #10573/D/17
Report #10576/A/17
Report #10576/B/17
Drawing #
032Z-15
033Z-15
159Z-15
158Z-15
032Z-15
033Z-15
Total = 5
INSULATORS
4. 6
INSULATORS, COMPOSITE, HORIZONTAL LINE POST, SUSPENSION AND TENSION TYPE (UP Applicable Standards: 15-TMSS-05
TO 230 KV)
E.B. REBOSIO S.R.L MOLDED DESIGN Prequalified for MOLDED TYPE DESIGN insulators
ITALY up to 132 kV
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
FCI (FURUKAWA COMPOSITE LSR DESIGN Prequalified for LSR TYPE DESIGN insulators
INSULATORS LTD)
HUNGARY
Budapest , Hungary
Website - http://www.fcifurukawa.hu
LAPP INSULATORS GMBH MODULAR DESIGN Type tests Prequalified for MODULAR TYPE DESIGN
GERMANY 115 kV 120/160 kN conducted at LAPP insulators
Germany lab
Plant -Bahnhofstrasse 5, 95632 Model:
Wunsiedel Germany 14K3349 & 50 Test Report No.
28/13 & 29/13
Contact Person - Mr. i.A. Thomas 230 kV
Zembsch 120/160 kN
Phone - +49 (0) 92 32 / 50 15 5
Email ID - Model:
tzembsch@lappinsulators.com 7.09538 & 39
Website -
http://www.lappinsulators.com
MACLEAN POWER SYSTEM MODULAR DESIGN Prequalified for MODULAR TYPE DESIGN
United States insulators
NGK LOCKE INC. Mitsubishi Corporation MOLDED DESIGN Tests performed: Prequalified for MOLDED TYPE DESIGN insulators
United States 5h Floor tower A4, 111 kN,160 kN (2011 & 2012)
Granada Business park Report # 120014T
Virginia Beach, Va, Usa Exit 9
Phone -
Contact Person - Mr. H. Enomoto +966-11-511-7516
Email ID - enomoto@ngk-polymer.com Email -
Website - http://www.ngk-locke.com/ hashim.a.ibrahim@mitsu
bishicorp.com
PFISTERER SEFAG AG MOLDED DESIGN Tests performed: Prequalified for MOLDED TYPE DESIGN insulators
SWITZERLAND (2013)
120 kN/160 kN (110 kV) PQ Letter
Plant -Malters, Switzerland Based on TS&SD letter# 10-02374-03032301
Drawing #: dated August 18, 2010It is pre-qualified for
Werkstrasse 7, 6102 Malters, 138206-393A Composite Suspension & Tension insulators up to
Switzerland 138206-667A 380 kV, Composite Line Post insulators up to 132
kV with the following conditions:
Email ID - info.uk@pfisterer.com
Website - http://www.sefag.ch WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order
XIANGYANG GUOWANG COMPOSITE Molded Design Prequalifed for MOLDED TYPE DESIGN insulators
INSULATORS CO. up to 132 kV only.
CHINA
WARRANTY:
Plant -Xiangyang city, China. Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
No.10, Dengman Road, High & New installation & workmanship from the date of
Tech Park, Industry District, Xiangyang, Provisional Acceptance Certificate (PAC) of the
Hubei 441057, P.R China first turnkey project in case of contract award or
date of first delivery in case of direct material
Contact Person - Mr. Wang Xin supply order shall be given for the proposed 132
Phone - Tel: 0086-710-3262531,Fax: kV composite insulators
0086-710-3250621
The warranty/ guarantee shall be applicable from
first project and shall cover all the cost of
materials and labor as per warranty / guarantee
of materials and subsequently reduced yearly in
case of future project award. This was agreed
through the manufacturer letter # GCR-06-02
dated 2015-07-08.
Note:
Previously “XIANGFAN GUOWANG”, the name
has been changed to “Xiangyang Guowang
Composite Insulators Co. Ltd.” based on the
manufacturer letter # RI/PQ/
XYGW/TT132/2015/008 dt: August 09, 2015 and
the supporting documents approved by the
concerned authorities in China.
Total = 7
INSULATORS
4. 7
INSULATORS, COMPOSITE, HORIZONTAL LINE POST, SUSPENSION AND TENSION TYPE (UP Applicable Standards: 15-TMSS-05
TO 380 KV)
LAPP INSULATORS GMBH MODULAR DESIGN Prequalified for modular type design insulators
GERMANY Rating: Tests Performed: CONDITION:
160 kN-380 kV Type tests Any new type of Insulators (other than the types
Plant -Bahnhofstrasse 5, 95632 conducted at LAPP already tested) offered by Lapp, Germany shall
Wunsiedel Germany Model – Germany lab, EGU & be Type Tested in presence of three (3) SEC
Rodurflex CS160SB30/79 ZKU Engineers and one (1) Approved Independent
Contact Person - Mr. i.A. Thomas (195/163)4900 Agency Inspector.
Zembsch 7.095670.80.01.00/ Lapp Germany Test
Phone - +49 (0) 92 32 / 50 15 5 7.095670.80.22.00 Report No. 29/13, dt: WARRANTY:
Email ID - 09/04/2013 Ten (10) years extended warranty/guarantee in
tzembsch@lappinsulators.com respect of defects due to design, manufacture,
Website - EGU Test Report installation & workmanship from the date of
http://www.lappinsulators.com No.9898/A/13 from Provisional Acceptance Certificate (PAC) of the
03/04/2013 to first turnkey project in case of contract award or
08/04/2013. date of first delivery in case of direct material
supply order
ZKU Test Report No.
13-059, dated:
05/04/2013
MACLEAN POWER SYSTEM Yousif Al Hobays Office MODULAR DESIGN Type tests Prequalified for MODULAR TYPE DESIGN
United States for Trading Service conducted at EGU, insulators
PO Box 301134 Riyadh Model: ZKU,Klokar &
Plant -7801 Park Place Road 11372 Saudi Arabia Cat./Drawing S678192 VG03 KFUPM WARRANTY:
Email:yhobayb@gmail.co Ten (10) years extended warranty/guarantee in
York, South Carolina m EGU Test Report respect of defects due to design, manufacture,
29745, USA No.9447/08 dt: installation & workmanship from the date of
18/11/2008. Provisional Acceptance Certificate (PAC) of the
Contact Person - Mr. Ms. Anabel first turnkey project in case of contract award or
Gdriozola EGU Test Report date of first delivery in case of direct material
Contact Person Email ID - No.9449/08 dt: supply order, as confirmed by the manufacturer
addriozola@macleanfogg.com 16-17/12/2008 through their letter no.RI/MCLN/SEC/AS, dt: 5th
Website - http:// April, 2007.
http://www.macleanpower.com/ ZKU Test Report No.
08-109, dt:
21/10/2008)
NGK LOCKE INC. Mitsubishi Corporation MOLDED DESIGN Tests performed: Prequlified for MOLDED TYPE DESIGN insulators
United States 5h Floor tower A4, July 01-05, 2008,
Granada Business park 380 kV,178 kN July 25-27, 2011 PQ Letter
Virginia Beach, Va, Usa Exit 9 and April 20-27, Based on TS&SD letter #
Phone - 402-SL1370-SK-95 2005 10-F02356/02-03032301 dated 22/11/2010, it is
Contact Person - Mr. H. Enomoto +966-11-511-7516 pre-qualified for 380 kV Composite Insulators:
Email ID - enomoto@ngk-polymer.com Email:hashim.a.ibrahim@ 380 kV,222 kN Report #
Website - http://www.ngk-locke.com/ mitsubishicorp.com Models: 080022T (For 380 WARRANTY:
kV, 178 kN Ten (10) years extended warranty/guarantee in
50B-SL1370-SK-95 Insulators) respect of defects due to design, manufacture,
50B-SL1370-SK-59 110036T & 050028T installation & workmanship from the date of PAC
502-SL1770-SK-95 (For 380kV, 222kN of the turnkey project in case of contract award
502-SE1570-SK-15 Insulators) or date of delivery in case of direct material
230 kV,160 kN supply order.
36B-SS1140-SK-08 120014T,
230 kV,111 kN PO3031T,
251-SL970-3J-09 030058T,
TN-NCI-98143
132 kV, 160 kN TN-NCI-2000009 R1
36B-SS620-SK-0A
132 kV 111 kN
25A-SL540-SJ-0A
115 kV,160 kN
36B-SL510-SK-0A
115 kV,111 kN
25A-SL440-SJ-0A
PFISTERER SEFAG AG Tests performed Prequlified for MOLDED TYPE DESIGN insulators
SWITZERLAND
MOLDED DESIGN PQ Letter
Plant -Malters, Switzerland Based on TS&SD letter# 10-02374-03032301
160 kN-380 kV dated August 18, 2010It is pre-qualified for
Werkstrasse 7, 6102 Malters, Composite Suspension & Tension insulators up to
Switzerland Drawing #: 380 kV, Composite Line Post insulators up to 132
138206-588BC kV with the following conditions:
Email ID - info.uk@pfisterer.com
Website - http://www.sefag.ch 160kN (380kV) WARRANTY:
Ten (10) years extended warranty/guarantee in
Drawing #: respect of defects due to design, manufacture,
138206-588BC installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
Total = 4
INSULATORS
4. 8
RTV SILICON RUBBER INSULATOR COATING Applicable Standards: 15-TMSS-07
Total = 2
AL BABTAIN POWER&TELECOM CO
Saudi Arabia
AL ZAMIL STEEL
Saudi Arabia
WARRANTY
Ten (10) years Extended Guarantee / Warranty
from the date of PAC of first Project (in case of
contract award) or from the date of delivery for
the direct material supply order,as confirmed
through their Letter # Nil dated 04/01/2015.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
through their letter no. AS/2009/0704/001, dt: 7th
April, 2009..
AL-SALAM INSDUTRIES AND TRADING Only one trial 110/132kV transmission line project
EST./ADVANCE TECHNOLOGIES. only (short line)
Saudi Arabia
Email ID - aic@aicsteel.com.
Website - http://www.aicsteel.com/
ENERGYA STEEL SOLUTION (HESHAM latticed steel Based on S&SD letter # 15-10909-02-30504401
HELAL EL SEWEDY & PARTNERS FOR structures up to 380 kV dated February 10, 2016 , TS&SD letter#
STEEL INDUSTRIES CO.) 09-2179/07-03032301 dated November 11, 2009,
Saudi Arabia approval of Executive Directive for TS&SD letter#
09-02179/06-03032301 dated November 11,
Rabigh – Yanbu High Way Exit 927 2009 & based on S&SD letter#
Industrial Zone Aramco Road 13-01978/01-30504401 dated June 10, 2013, it is
pre-qualified for
Contact Person - Mr. Ahmed Khan , Mr.
Rayan A. Taj - Substation Steel Structures up to 380 kV
Phone - +966-5609678655 Tel: +966
500150706 ,Fax: +966 500576159 - Transmission Towers for projects up to 380
Email ID - info@energyasteel.com kV(Except design)
Contact Person Email ID -
ahmed.khan@energyaksa.com, and
Rayan.Taj@energyasteel.com - Communication Towers for Transmission
,Rayan.Taj@energyaKSA.com Sector
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order
This was confirmed, through their Letter # nil
dated October 14, 2014.
GEYARD FOR COMMERCE AND Prequalified for Substation Steel Structures only
IMPORT CO.
Saudi Arabia
HIDADA
Saudi Arabia
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
Chennai , India
Website -
http://www.larsentoubro.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order.
Total = 16
AL BABTAIN POWER&TELECOM CO
Saudi Arabia
HIDADA
Saudi Arabia
PETIT JEAN
FRANCE
Website - http://www.petitjean.fr/uk/ec
gm.php
SUMMIT MANUFACTURING
United States
Pa , United States
Website - http://www.summitmc.com/
TECHNOPALI
ITALY
Website - http://www.technopali.co.uk
VALMONT
United States
Website - http://www.valmont.com/
Total = 7
Website -
http://www.amiantit.com/en/default.php
Total = 2
3M
United States
Website - http://solutions.3m.com/en
US/
AB WIRE
SWEDEN
Website - http://www.moorlink.com/
ABAHSAIN-COPE
Saudi Arabia
Website -
http://www.abahsain.net/Abcope.htm
AL-AMAL CO. Type / Model: FOR LADDERS & Type Tests FOR LADDERS & ACCESSORIES
Saudi Arabia ACCESSORIES conducted in King
Saud University on WARRANTY:
Riyadh, Saudi Arabia 14th July, 2008 Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order as confirmed by the manufacturer
vide their letter no. IMD-CR-955, dt: October 29th,
2007.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by Al-Ashouri
Industries through letter # 2010/4-03/0003 dated
01/08/2010.
AL-MISBAH HOUSE FOR STEEL Type / Model: Metallic Cable Tray PQ Letter
WORKS Systems Based on TS&SD letter 09-00509/1-03032301
Saudi Arabia dated 16th. March 2009 for Metallic Cable Tray
Rating: Systems.
Riyadh , Saudi Arabia
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
Email ID - aic@aicsteel.com.
Website - http://www.aicsteel.com/
EFCOR
United States
WARRANTY:
Eight (8) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order as confirmed by the manufacturer
through their letter no.nil, dt: 2nd Aug, 2008.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #nil, dt: 2nd Dec, 2012.
HIDADA
Saudi Arabia
Website - http://www.hidada.com.sa/
Website -
http://mecss.com.sa/contact.html
O-Z GEDNEY
United States
Website - http://www.o-zgedney.com/
Website - http://www.seico.com.sa/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #NIL, DT: 15th Jan, 2013.
TOLARTOIS
FRANCE
Website -
http://www.tole-perforee.com
WESCOSA
Saudi Arabia
Website - http://www.wescosa.com/
Total = 17
ABB ( T& D)
United States
Website - http://www.abb.us/
ALPHA NIDAU
SWITZERLAND
CONDITION:
All type/special and routine tests for Disconnect
Switches 420kV, 4000A (S3CD, S3CDT &
S3CD2T) only and Standalone Grounding
Switches (STB) 420kV, 63kA only shall be
conducted at in an Independent testing laboratory
on one switch before supplied to SEC system in
the presence of three (3) SEC/National Grid SA
engineers & one (1) National Grid SA approved
independent inspection agency Inspector, all the
related costs for witnessing the tests will be
borne by the manufacturer. This was confirmed
by Alstom Grid S. p .A, ITALY through their letter
# 323/11/C/RP.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #136/11/CO/RP.
AREVA
FRANCE
Plant -France
Website - http://www.areva.com/
EFACEC
PORTUGAL
Website -
http://www.efacec.pt/presentationLay
er/efacec home 00.aspx
Website - http://www.hapam.nl/
MG/EGIC
FRANCE
S&C
United States
Website - http://www.sandc.com/
SDCEM
FRANCE
Website - http://www.sdcem.com/
SIEMENS
GERMANY
Website - http://
http://www.siemens.de/Pages/EntryPa
geRedirect.aspx
Website -
http://www.southernstates.com/
Total = 12
SUBSTATION PANELS
9. 1
RELAY & CONTROL PANEL Applicable Standards: 31-TMSS-01
ABB S.R.O (RFF) ABB Automation Co. Ltd. Type tested in PQ Lettter
CZECH REPUBLIC PO Box.414 Riyadh Independent Lab Based on S&SD letter# 15-09012-1-30504401
11383 EZU Parague, Czech dated November 05, 2015, it is pre-qualified for
Stetkova 1638/18,140 00 Praha 4Czech republic/EVPU Nova Relay & Control Panels as conforming to National
Republic-Trutnov Dubnica, Slovakia on Grid SA specification # 31-TMSS-01, with the
5th to 15th may following condition:
Contact Person - Mr. Essam 2015
Bashraheel & Mr Aref Al-Arrak Report#08.220.985. WARRANTY
Email ID - Ten (10) year Extended Warranty as confirmed
Essam.bashraheel@sa.abb.com through
&Aref.alarrak@sa.abb.com their Letter No. 14-05231-01-30504401 dated
November 10,
2014 shall be applicable for all supplies by ABB
s.r.o (RFF), Trutnov-Czech Republic.
ABB SWITZERLAND LTD ABB Automation Co. Ltd. Type tested in PQ Lettter
SWITZERLAND PO Box.414 Riyadh Independent Lab Based on S&SD letter# 15-09013-1-30504401
11383 EZU Parague, Czech dated November 05, 2015, it is pre-qualified for
Contact Person - Mr. Essam Republic /EVPU Relay & Control Panels, as conforming to National
Bashraheel & Mr Aref Al-Arrak Nova Dubnica, Grid SA specification # 31-TMSS-01 with the
Email ID - Aref.alarrak@sa.abb.com, Slovakia on 5th to following condition:
Essam.bashraheel@sa.abb.com 15th may 2015
WARRANTY
Report#08.220.986. Ten (10) years Extended Warranty as confirmed
through
their Letter #14-05230-01-30504401 NIL dated
4th November 2014 shall be applicable for all
supplies made by ABB Switzerland Ltd -
Switzerland.
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
ACRASTYLE
United Kingdom
Website - http://www.acrastyle.co.uk/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #NIL, DT: 03/10/2013.
AREVA
United Kingdom
Website - http://www.areva.com/
Website -
http://www.kerrcruickshank.com/
Ingenious Network FZC Power Flow Contracting NGSA-RCP-16001-B / Up to 132KV Ingenious Network PQ Letter
United Arab Emirates Siteen Street, Al-Malaz, FZC- Sharjah, UAE Based on S&SD letter # 17-00160-1-30504401
Dsitrict P.O Box 325917, successfully dated January 19, 2017, Ingenious Network FZC-
Plant -Saif Free Zone, Sharjah, UAE Riyadh-11371, KSA completed type Sharjah, UAE is pre-qualified for Relay & Control
+966 11 4734876 Panels up to 132kV as conforming to National
Q3-047 Sharjah Airport International Rami.azzam@powerflo Grid SA specification # 31-TMSS-01, with the
Free Zone (SAIF Zone) Al Dhaid Road, w-sa.com following conditions:
P.O Box 120110, Sharjah, United Arab
Emirates WARRANTY:
Ten (10) years extended warranty from the date
Sharjah of PAC of the first project (in case of contract
award) or date of first delivery (in case of direct
Contact Person - Mr. Tabish M. Ismail, material supply order), as confirmed, through
Sales & Marketing their Letter No. PQN-SEC-15001-RCP-6A dated
Phone - +971 6 5579471 June 6,2015 shall be applicable for all Relay &
Email ID - Control Panels to be supplied to SEC/National Grid
ahmed.bader@ingenious-network.com SA.
Contact Person Email ID -
tabish.i@ingenious-network.com
Website -
www.ingenious-network.com
KONCAR ELEKTRICNI UREDAJI D.D Nesma Telecom& Rating - upto 380 kv PQ Lettter
CROATIA Technology Co. Ltd. Based on S&SD letter# 14-1456-03-30504401
Jeddah Asfan Road dated April 15, 2014, it is pre-qualified for Relay &
Plant -Zagreb/Croatia - Hrvatska inside azzam compound Control Panel up to 380 kV as conforming to
Tel:012-2727637,Phone - National Grid SA specification # 31-TMSS-01,
Končar-Električni Uređaji D.D. Prisoje 0500000582 with the following condition:
29A, 21232, Dicmo, Hr Email - WARRANTY
nesmaelectric@nesma.c Ten (10) years extended warranty/guarantee in
Contact Person - Mr. Ljubomir Zubčić, om respect of defects due to design, manufacture,
Phone - +385 21 778 512; +385 91 374 installation & workmanship from the date of
2009 Provisional Acceptance Certificate (PAC) of the
Email ID - Email first turnkey project in case of contract award or
:ljubomir.zubcic@koncareu.hr date of first delivery in case of direct material
Website - Web: supply order.
http://www.koncareu.hr
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #META/12/AM, dt: Mar 23, 2011.
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter no.nil, dt: 18th July, 2008.
REYROLLE LTD.
United Kingdom
Website -
http://www.reyrolle-protection.com/
Grenoble France
TIEPCO
Saudi Arabia
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by the manufacturer
thru letter #nil, dt: 16th june, 2010.
Total = 27
SUBSTATION PANELS
9. 2
AUXILIARY AC/DC PANELS Applicable Standards: 31-TMSS-02
Website -
http://www.atco.com.sa/en/manufactu
ring east west factory.asp
Website - http://www.hawaepbf.com
META SWITCHGEAR COMPANY Rating: The tests have been Previously MEMF-ETA Switchgear Manufacturing
Saudi Arabia ACDB 230/400 Vac, upto 3200 A, 75 conducted at CPRI, Company, Riyadh, Saudi Arabia [The name has
kA, 1 sec. India, witnessed by been changed based on S&SD letter #
P. O. Box 61891, Riyadh 11575, Saudi UL & SGS Engineers 14-02218-01-30504401 dated March 23, 2014].
Arabia,Near 2Nd New Industrial, 2Nd DCDB 800 A, 25 kA, 1sec. and certificates and
Phase Riyadh 11575, Saudi Arabia test reports are PQ Letter:
(Branch Of Memf Electrical Industries issued by UL. SGS S&SD letter # 14-02218-01-30504401 dated
Co.) inspection report March 23, 2014 & TS&SD letter
CHN/VCS/014/2014 #11-F03210/01-03032301 dated 29/11/2011
dated 24/01/2014 pre-qualified for AC&DC Panels.
for ACDB & DCDB
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by MEMF-ETA
Switchgear Manufacturing Company through
letter # META/11/13/AM, dated 21st Feb, 2011.
Website - http://www.alojaimi.com/Our
Companies/Introduction - Mohammed
Al-Oja/introduction - mohammed
al-oja.html
MUSAID SWITCHGEAR,
Saudi Arabia
REMAL
Saudi Arabia
Website - http://www.remal.com/
SIEMENS
Saudi Arabia
Plant -Jeddah
Website - http://www.siemens.com.sa
CONDITION:
All type, special, routine and sample tests as per
SEC specifications/standards shall be carried out
on the first batch of each type of Auxiliary
AC&DC Panels to be supplied to SEC in case of
securing an order in the presence of three (3)
SEC engineers & one (1) approved independent
inspection agency Inspector in an independent
testing laboratory. All the related costs for
witnessing the tests will be borne by the
manufacturer. This was confirmed by
WESCOSA-Dammam through letter # Nil dated
18/05/2010.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of first delivery in case of direct material
supply order, as confirmed by
WESCOSA-Dammam through letter # Nil dated
30/08/2010.
Total = 13
SUBSTATION PANELS
9. 3
TERMINAL BLOCKS Applicable Standards: 31-TMSS-06
ABB ENTRELEC
FRANCE
Website -
http://www.abb.com/cawp/seitp202/c1
256c290031524bc1256a2900291e39.a
spx
Cabur PQ Letter:
ITALY • Based on S&SD letter # 17-0071-030504401
dated January 09,2017, Cabur, Altare- Italy is
Plant -Altare- Italy pre-qualified for Terminal Blocks as conforming to
National Grid SA specification # 31-TMSS-06,
Contact Person - JAL International, Mr. with the following conditions:
Muhammad Sajjad Manzoor
Contact Person Email ID - WARRANTY:
sajjad.manzoor@jalinternational.com.sa • Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first project (in case of contract award) and from
the date of first delivery in case of direct material
supply order shall be provided as confirmed by
the manufacturer through their letter No. NIL
dated 18/12/2015.
PHOENIX
GERMANY
Website -
http://www.phoenixcontact.com/termin
al-blocks/26840.htm
WEIDMULLER
GERMANY
Website - http://www.weidmuller.com/
Total = 8
SWITCHGEAR
10. 1
METAL – ENCLOSED AIR INSULATED SWITCHGEAR 11 KV THROUGH 34.5 KV Applicable Standards: 32-TMSS-01
ABB ( T& D)
United States
Website - http://www.abb.us/
Incomer (CT upper & lower side of CB): Circuit breaker up to 24kV, 4000A, 40kA from
(1000x2200/2595x1400/1780mm), ABB-SACE-Italy (ITABB).
Bus Section
(1000x2200/2595x1400mm) &,
Bus riser (800x2200/2595x1400mm):
3003 @ 40°C, 60Hz, 25kA (3s)/65kAp.
1600A SWGR:
1600A Incomer
(800x2200/2595x1400mm) ; Bus
Section (800x2200/2595x1400mm, Bus
Riser (650x2200/2595x1400mm:
1607A @ 40°C, 60Hz, 25kA(3s)/65kAp
CIRCUIT BREAKERS:
Incomer, Bus Section: VD4 17.31-25
(vacuum interrupter VG6), ABB Italy
(embedded pole)
FORCED COOLED
Rating:
13.8kV, 3600/4000A @ 40°C, 60Hz,
TYPE/MODEL:
UniGear ZS1 13.8kV SWGR with CT
upper & lower side of CB.
Incomer (1000×2595x1780mm),
VCB-VD4 1731-25,Vacuum
Interrupter-VG6
OLD VERSION:
Rating: 13.8kV
Plant -Germany
Website -
http://www.alibaba.com/member/smilja
nmusic/contactinfo.html
CIRCUIT BREAKERS:
3150A Incomer & Bus Section:
LVB-17M-40D/30-1E2H (vacuum
interrupter LV10403).
1250A Outgoing Feeder:
LVB-17M-25D/12-1E2H (vacuum
Interrupter LV10252).
Capacitor Bank:
LVB-17M-25D/12-1E2H (Vacuum
Interrupter LV12503), 630A, Class C2
TYPE/MODEL: NES-H
FORCED COOLED
Rating:
Incomer (1000×2793x1880mm),
VCB-LVB-17M-40D/301E2H,
Interrupter-10403
Website - http://www.areva.com/
EFACEC ENERGIA MAQUINAS E Bandariyah International 33kV SWGR: Type tests pending for 13.8 kv and 33 kV
EQUIPAMENTOS ELECTRICOS, S.A Co. Ltd, Type / Model: QBN7 switchgear
PORTUGAL CONTACT PERSON:Raid
Shabsough or Rejith Rating: 36KV SWGR, Natural cooling.
Plant -Porto/Portugal Rami , 3rd Floor Building
3 Mutlaq complex, P.O. 13.8kV SWGR:
Parque Empresarial Da Arroteia 4296, Al Khobar-31952,
(Poente), Apartado 1018 4468-952 S. KSA Type / Model: NORMACEL
Mameda De Infesta- Portugal Phone: 966-555010864
& Phone: Rating: 13.8kV Natural cooling.
Contact Person - Mr. Antonio Sarsfield 966-553712308
Phone - +3512 968496257, rshabsough@bandariya
Email ID - santossilva@efacec.com, h.com Or
ams@efacec.comSantos Silva rrami@bandariyah.com
Website -
http://www.efacec.pt/presentationLay
er/efacec home 00.aspx
CIRCUIT BREAKERS:
Incomer, Bus Section: VD4 17.31-25
(vacuum interrupter VG6), ABB Italy
(embedded pole)
EARTHING SWITCH:
UMR, ELEKTROBUDOWA SA, Poland
OLD VERSION:
Type / Model: F400G
CIRCUIT BREAKER
SF1 & SF2
13.8kV SWGR:
Rating:
13.8kV, 2500A @ 55°C, 60Hz,
CIRCUIT BREAKERS:
2500 (3150A) Incomer, Bus Section:
LF3 -3150@ 40°C, 60Hz) Interrupter
SF6
FORCED COOLED
Rating:
13.8kV, 3600A @ 40°C, 60Hz,
25kA(3s)/65kAp, IP4X, FORCED
COOLED, CT lower side of CB.
HITACHI LTD 33kV SWGR: Originally JAPAN AE POWER SYSTEM CORP and
JAPAN subsequent change affected as per HITACHI
Type/Model: letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated
Rating: 18-12-2012.
Akihabara Daibiru Building, 18-13,
Soto-Kanda 1-Chome, Chiyoda-Ku, 13.8kV
Tokyo, 101-8608, Japan
Type/Model:
Contact Person - Mr. Masaharu Tsumori
Phone - +81-3-4564-4741
Email ID -
masaharu.tsumori.gx@hitachi.com
Website - http://www.hitachi.com
KONCAR ELECTRICAL EQUIPMENT 33kV SWGR CONDITION: Type tests required for 13.8 kv & 33
(KONCAR), SPLIT Type / Model: BVK-s-38 kv Switchgear
CROATIA
Rating: 33kV,
Plant -Split/Croatia – Hrvatska
CIRCUIT BREAKER:
Koncar Elektricni Uredaji D.D Prisoje
29A, 21232 Dicmo Hr CT & VT:
Rating:
CIRCUIT BREAKER
LSIS METS Middle East Solution Power V17 & CB type LVB17 Type test were PQ Letter:
KOREA, Republic of Technical Services 13.8 kV successfully S&SD letter# 15-03781-2-30504401 dated June
Contact Person:Mr. conducted in KERI 04, 2015,for for MV Switchgear Type “ Solution
Plant -Republic Of Cheongju, Korea Abdul Majeed Atiyyah Incomer, Bus Section and Bus Riser Korea during 16th Power V17” & CB type “ LVB17” rated for 13.8
Vice President & Mr. ratings June to 17th July kV.
Ls Tower, 127 Ls-Ro Dongan-Gu Won Koo Kwon General (W-950xD-2000xH-2620 mm); 3000A 2014 in Presence of
Anyang-Si Syeonnggi-Do 431-848 Manager , P.O. Box: @ 40°C, 60Hz, 25kAp Approved IIA WARRANTY:
Korea 4323 Riyadh - 11491 (3s) / 65kAp, natural cooled. Inspector. Ten (10) years extended warranty/guarantee will
Kingdom of Saudi Type Test Report be applicable for all 13.8 kV Medium Voltage
Contact Person - Mr Je Woo Lee Power Arabia. Outgoing feeder & Capacitor feeder #2014TC00634 Switchgear type Solution Power V17 to be
Grid Business Group & Tel: +966 1 (630 A / 1250A) - supplied to SEC/National Grid SA as confirmed
Mr.Kui-Joong,Yun General Manager PQ 2424923,Fax: +966 1 (W-750xD-2000xH-2620 mm); 1250A through LSIS Letter #013/LSIS-PQ/2015 dated
Dept Powr Grid Business Group 2424924 @ 40°C, 60 Hz, 25kA 26th May 2015.
Phone - +82-2-2034-4541 , wkkwon@mets.com.sa , (3s) / 65kAp, natural cooled.
82-2-2034-4918 aatiyyah@mets.com.sa • Circuit Breaker:
Email ID - jwleea@lsis.com Incomer & Bus section: LSIS, Korea –
,kjoongy@lsis.com Type
(LVB-17M-40D/30-1E2H, Interrupter:
LV10403, Opr. Mech:
Motor-spring, LVB Pro-MEC)
Outgoing feeder: LSIS, Korea-Type
(LVB-17M-25D/12-1E2H,
Interrupter: LV10252, Opr. Mech:
Motor-spring, LVB Pro-MEC)
Capacitor feeder: LSIS, Korea-Type
(LVB-17M-25D/12-1E2H-DB,
Interrupter: LV12503, Opr. Mech:
Motor-spring, LVB Pro-MEC), Capacitor
Bank back to back
switching current-630A.
• Earthing switch Type SEH/MH31SM &
SEH/MH31M.
• CT: ABB, Czech (CT located in upper
& lower side of CB for
I/C, O/G, B/S).
• VT: ABB, Czech
S&C
United States
Website - http://www.sandc.com/
SIEMENS
United States
Website -
http://www.usa.siemens.com/entry/en/
SIEMENS Siemens Ltd. 13.8 kV AIS: Type/Model: NXAIR, Type Tests PQ letter:
TURKEY P.O. Box 4621, Jeddah 3600A conducted at IPH Based on S&SD letter # 17-04571-02-30504401
21412, K.SA. CESI-Berlin and dated June 22, 2017, SIEMENS -Turkey is
Plant -Turkey 02 661 8972 For Incomer: KEMA & PEHLA pre-qualified for 13.8KV Switchgear Type NXAIR
Aslam.jameel@siemens. 13.8kV, 3008A, @40 °C, 60Hz, as conforming to latest National Grid SA
Gebze Organize Sanayi Bolgesi, 1000. com 25kA(3s)/65kAp, AFLR with Natural specification # 32-TMSS-01, with the following
Cd. No. 1004, 41480-Gebze, Kocaeli, cooling, Dimensions (2500H X 1000W X conditions:
Turkey 2250D), CT Upper & Lower of CB
13.8kV, 3600A @40 °C, 60Hz, 25kA Warranty :
Gebze, Kocaeli (3s)/65kAp, AFLR with Forced cooling • Ten (10) years extended warranty/guarantee in
(4-fans), Dimensions (2500H X 1000W respect of defects due to design, manufacture,
Contact Person - Mr. Ediz Gizlier X 2250D), CT Upper & Lower of CB installation & workmanship from the date of
Phone - +90 (262) 676 2000 Circuit Breaker: 3AE1666-7, 13.8kV, Provisional Acceptance Certificate (PAC) of the
Email ID - ediz.gizlier@siemens.com 3150A, @40 °C, 60Hz , 25kA first turnkey project in case of contract award or
Contact Person Email ID - (3s)/65kAp, Vacuum Interrupter: date of delivery in case of direct material supply
ediz.gizlier@siemens.com VS17040, Opr. Mechanism: SION order, as confirmed in writing by the
Website - www.siemens.com.tr 3AE1666 manufacturer through their letter #
Earthing Switch: Siemens, Turkey, AEL-E/PQ/NXAIR/02/2013 dated July 25, 2014.
Type: 174-3138.3
CT & VT: ALCE, Turkey/Pfiffner, Turkey
For Bus Section:13.8kV, 3008A, @40
°C, 60Hz, 25kA(3s)/65kAp, AFLR with
Natural cooling, Dimensions (2500H X
1000W X 2250D), CT Upper & Lower
of CB
13.8kV, 3600A @40 °C, 60Hz, 25kA
(3s)/65kAp, AFLR with Forced cooling
(4-fans), Dimensions (2500H X 1000W
X 2250D), CT Upper & Lower of CB
Circuit Breaker: 3AE1666-7, 13.8kV,
3150A, @40 °C, 60Hz , 25kA
(3s)/65kAp, Vacuum Interrupter:
VS17040, Opr. Mechanism: SION
3AE1666
CT & VT: ALCE, Turkey/Pfiffner, Turkey
For Bus Riser:
13.8kV, 3008A, @40 °C, 60Hz,
25kA(3s)/65kAp, AFLR with Natural
cooling, Dimensions (2300H X 1000W X
1750D)
13.8kV, 3600A @40 °C, 60Hz, 25kA
(3s)/65kAp, AFLR with Natural
Website -
http://www.toshiba.co.jp/index j3.htm
VA TECH
FRANCE
Plant -France
Website - http://www.vatech-hydro.at
WESCOSA
Saudi Arabia
Website - http://www.wescosa.com/
Total = 21
SWITCHGEAR
10. 2
SF6 GAS INSULATED SWITCHGEAR 110kV to 132kV Applicable Standards: 32-TMSS-02
ABB
SWITZERLAND Type / Model:
OLD VERSION:
Type/ Model: ELK-04
FUJI ELECTRIC CO. 145kV GIS Originally JAPAN AE POWER SYSTEM CORP and
JAPAN subsequent change affected as per HITACHI
OLD VERSION letter # XAE-VR-121213, dated 13-12-2012 and
Type/ Model: SDA5 (SDA514), 145kV FUJI letter # AT-LTR-121115-1, dated
18-12-2012.
CB type: BAK5, Hydraulic mechanism.
CB Capability:
Inductive load switching: NO
Capacitor bank back to back Switching:
NO
GE GRID GMBH GIS Type test completed Based on S&SD letter# 13-4433-01-30504401,
SWITZERLAND 145kV GIS type F35 with dated 16 January 2013, it is pre-qualified for
rated current, 3150A @40°C, 60Hz, 145kV GIS type F35 with rated current, 3150A
Plant -. @40°C, 60Hz, against specification #
CB type- F35-CB4 / Opr. 32-TMSS-02, Rev.1 with the following condition:
Oberentfelden Switzerland Mech: FK3-2 (spring charged),
CB Capability for: 1. Eight (8) years extended warranty from the
Inductive load switching: YES date of PAC of the first turnkey project (in case
of contract award) or from the date of first
Capacitor bank back to back Switching: delivery of direct material supply order. This was
YES confirmed through manufacturer lletter ref:
Q1F35_210409 dated 21 April 2009.
Line & Busbar DS-F35-DES-4/
Opr. Mech: ME1-3, Old Version:
145kV GIS type B65 with CB type B65-
MES-F35-DES-4/ Opr. Mech: ME1-3, Previously " Areva T &D AG,
SWITZERLAND-Oberentfelden ", the name has
HES-F35-EFZ/Opr. Mech:MF-3 (spring been changed to ALSTOM Grid AG,
charged), Oberentfelden, Switzerland, based on ALSTOM
Grid Letter # Nil dated July 11, 2012.
CT-F35-CT4, Previously " ALSTOM Grid AG Switzerland,
Oberentfelden ", the name has been changed to "
OLD GE Grid Switzerland GmbH,Oberentfelden ".
based on GE Grid letter # Nil dated June 01, 2016.
145kV GIS type B65
DS type B65-DS
ES type B65-ES
HITACHI LTD 145kV GIS Originally JAPAN AE POWER SYSTEM CORP and
JAPAN NEW VERSION: subsequent change affected as per HITACHI
Type/ Model: CFTA letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated
Rating: 145kV, 18-12-2012.
Akihabara Daibiru Building, 18-13,
Soto-Kanda 1-Chome, Chiyoda-Ku, CB type: CFPT-120-40L, FAR3 Motor NEW VERSION:
Tokyo, 101-8608, Japan spring mechanism PQ Letter:
MD # 011/63000/KB/169, dated 18-08-1422 (H),
Contact Person - Mr. Masaharu Tsumori CB Capability: pre-qualified GIS type CFTA.
Phone - +81-3-4564-4741 Inductive load switching: NO
Email ID - Capacitor bank back to back Switching:
masaharu.tsumori.gx@hitachi.com NO
Website - http://www.hitachi.com
DS type: CFL-120
ES type: CFL-120
OLD VERSION
Type/ Model: CFT
Rating: 145kV
DS type: SFL-EA
Hitachi Power Systems Indonesia Walid Jufalli Corporation GIS: CFTA-145, 145kV, 3150A @40 145kV GIS Type PQ letter:
(HPSI) (WJCO) ºC, 60HZ, 40kA (1s)/104kAp. CFTA with CB, Based on S&SD letter # 17-03689-03-30504401
Indonesia P.O Box#1380, Jeddah DS/ES & cable dated May 18, 2017, it is pre-qualified for 145kV
21493, Kingdom of Saudi Circuit Breaker: compartment has GIS Type CFTA with CB CFPTB-40LB, FAR3 as
Plant -Indonesia Arabia. CFPTB-120-40LB-FAR3, 145kV, 3150A successfully conforming to National Grid SA with specification
Mr. Yuichi Wakabayashi, @40 ºC, 60HZ, 40kA (1s)/104kAp with completed the type # 32-TMSS-02 with the following conditions:
EJIP Industrial Park Plot 8E, Cikarang +966 (12) 2637600 & spring charge operating mechanism tests in laboratories;
Selatan, Bekasi, 17750 Indonesia +966 500338276 type: “FA”. KERI – Korea during WARRANTY:
yuichi.wakabayashi@hit 25 July to 10 August •Ten (10) years extended Guarantee/warranty
Contact Person - Mr. Hendrawan, achi-td.com Busbar DS: CFL-EEA, 145kV, 3150A 2016 & Hitachi from the date of PAC of the project (in case of
Phone - Phone: +62-21-8970350, @40 ºC, 60HZ, 40kA (1s)/104kAp with Laboratory- Japan contract award) or date of delivery (in case of
Mobile: +62 815 11536388 operating mechanism type “CA”. during 14 November direct material supply order), as confirmed to
Email ID - to 17 December SEC/National Grid SA, through their Letter No #
hendrawan@hitachipowersystems.co.i Line DS: CFL-EEA, 145kV, 3150A @40 2016 HPSI-BD/02/VIII/2014 R3 dated March 22, 2017.
d& ºC, 60HZ, 40kA (1s)/104kAp with
yoshikazu.hirotani@hitachipowersyste operating mechanism type “CA”.
ms.co.id
Contact Person Email ID - Mr. MS: CFL-EEA, 145kV, 60HZ, 40kA
Hendrawan, (1s)/104kAp with operating mechanism
Website - type “CA”.
http://www.hitachi.com/products/powe
r/TandD/location/index.html HSES: CFGM-FA, 145kV, 60HZ, 40kA
(1s)/104kAp with operating mechanism
type “MSG” Spring charged.
Hyundai Electric & Energy Systems Co. 145kV GIS NEW VERSION
Ltd NEW VERSION PQ Letter:
SOUTH KOREA Type/ Model: 145SP-1 TS&SD # 04-0692-030320, dated 15-03-2004,
pre-qualified GIS type 145SP-1
Plant -Ulsan Rating: 145KV, 2500A @40°C,
60Hz,40kA (3s)/ 104kAp
1000, Bangeojinsunhwan-doro, Previously Hyundai Heavy Industries Co. Ltd [The
Dong-gu, Ulsan, South Korea, CB type: 145SP-K1, Motor spring name has been changed based on P&SFD letter
mechanism #17-04234/01-030504401 dated May 24, 2017].
Ulsan
CB Capability:
Contact Person - Mr. D. H. Choi , Mr. Inductive load switching: YES
Jinweon Lee Capacitor bank back to back Switching:
Phone - +966-11-4644696, +82 31 NO
8006 6836
Contact Person Email ID - BDS type: 145SP-3PS1
danny.choi@hyundai-electric.com ,
leejw@hyundai-electric.com LDS type: 145SP-3PS2
Website -
http://www.hyundai-elec.com MES type: 145-3PS2
OLD VERSION:
Type/ Model: 145SP
Rating: 145kV
CB Capability:
Inductive load switching: NO
Capacitor bank back to back Switching:
NO
DS type: 145SP-DS
ILJIN ELECTRIC CO. LTD. GIS Type test completed Based on S&SD letter# 16-2020-01-030504401
SOUTH KOREA dated 31.03.2016 it is pre-qualified for 145kV GIS
145kV GIS type IJS1440-60, type IJS1440-60, 40kA(3s), 3150A as conforming
Plant -Hongseong, South Korea 40kA(3s), 3150A to National Grid SA specification # 32-TMSS-02,
with the following conditions:
905-17, Mannyeon-ro, Hwaseong-si, CB type IJC1440-60, Opr. Mech: • Ten (10) years Extended Guarantee / Warranty
Gyeonggi, KOREA IJCM1440-60 (Motor Spring) from the date of PAC of first Project (in case of
contract award) or from the date of delivery for
Contact Person - Mr. Jeong Kyung Woo • CB Capability for: the direct material supply order. This was
, Mr. Jaeho Kim Induced current switching: YES confirmed by the manufacturer through their
Phone - +82-2-707-9161 Capacitor Bank back to back switching: Letter # ILJHK20160217W dated 17.02.2016
Contact Person Email ID - YES
jkwoo@iljin.co.kr , jaeho.kim@iljin.co.kr
Website - http://www.iljinelectric.co.kr Busbar DS type:IJBDE1440-60
(Opr. Mech: IJBDEM1440-60)
KONCAR HIGH VOLTAGE 145kV GIS GIS & ADAPTORS ONLY TO DTA.
SWITCHGEAR INC, Type/ Model: K8D.6
CROATIA PQ Letter: As per existing
Rating: 132kV
Plant -Zagreb/Croatia-Hrvatska
CB Capability:
Borongajska Cesta 81C 10000 Zagreb Inductive load switching: NO
Capacitor bank back to back Switching:
Contact Person - Mr. Toni Delić NO
Phone - +385 (0)99 2475 663, +385
(0)1 235 4606
Email ID - toni.delic@koncar-eva.hr
Website - http://www.koncareu.hr
CT: JK
MITSUBISHI ELECTRIC CORPORATION 145kV GIS ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN NEW VERSION DURING APRIL 2005.
Type/Model: 100GMKD
Plant -T&D Systems Center, Amagasaki
City, Japan Rating 145kV, 60Hz,40kA (xs)/ 104kAp
OLD VERSION:
Type/Model: 120GMKM
Rating: 145kV
OLD VERSION:
Type/ Model: 100GMKD
Rating:145kV,
DS type: 120GLD
• Old version:
145kV GIS type HEXABOLIC-TH7
CB type
DTH7 Hydraulic mechanism
ES type ST TH7.
DS type 8DN8
ES type 8DN8.
NEW VERSION
Type/Model: 8DN8-II
Rating: 145kV
CB Capability:
Inductive load switching: NO
Capacitor bank back to back Switching:
NO
Rating: 145kV
CB Capability:
Inductive load switching: NO
Capacitor bank back to back Switching:
NO
DS type: 8DN8
ES type: 8DN8
TOSHIBA CORPORATION, T&D 145kV GIS Type Tested at ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN Toshiba lab during DURING APRIL 2005.
NEW VERSION 25th March to 12th 2005.
Website - April 204 & 18th to
http://www.toshiba.co.jp/index j3.htm GIS Type 20th Aug 2014 and NEW VERSION
G3A-b with CB type GSPK-145FPW / repeated internal arc
Opr. Mechanism tests in KEMA PQ Lettter
GSPK-145FW (spring charged); Netherland during Based on S&SD letter # 15-09018-2-30504401
CB Capability for: 8th to 10th April dated November 10, 2015, it is pre-qualified for
Inductive current switching: YES 2015 & 10th to 12th 145kV GIS Type
Capacitor bank back to back switching: June 2015. G3A-b, as conforming to National Grid SA
YES Report Nos. specification # 32-TMSS-02,
2238-15,30-07,29-0
Busbar DS type DAM-145W2 / 7,27-07, WARRANTY
Opr. Mech: DAM; Line DS type Ten (10) years Extended Guarantee / Warranty
DBM-145W2 / Opr. Mech. DBM; from the date of PAC of first Project (in case of
MES type EBM-145W2 / Opr. Mech. contract award) or from the date of first delivery
EBM; for the direct material supply order. This was
HES type confirmed, through their Letter No. TSB/TDS/AK/
EAP-145W2 / Opr. Mech. EAP (Spring 120930/2100A dated 01/04/2013.
charged)
OLD VERSION
Type/ Model:
Rating: 145kV
CB type: GSPK-145AP
CB Capability:
Inductive load switching: NO
Capacitor bank back to back Switching:
NO
Total = 16
SWITCHGEAR
10. 3
SF6 GAS INSULATED SWITCHGEAR 230 KV Applicable Standards: 32-TMSS-02
CB Capability:
Inductive load switching: xx
Capacitor bank back to back Switching:
No
CT Type: ELK-CN14/300
(1HC0071250M0040)
OLD VERSION
Type/ Model: ELK-1
Rating: 245kV
CB Type: ELK SP2-1.
FUJI ELECTRIC CO. 245kV GIS Originally JAPAN AE POWER SYSTEM CORP and
JAPAN subsequent change affected as per HITACHI
Type/Model: letter # XAE-VR-121213, dated 13-12-2012 and
FUJI letter # AT-LTR-121115-1, dated
CB: 18-12-2012.
CB Capability:
Inductive load switching: xx
Capacitor bank back to back Switching:
xx
HITACHI LTD 245kV GIS Originally JAPAN AE POWER SYSTEM CORP and
JAPAN subsequent change affected as per HITACHI
Type / Model: MFPT MFPTB-300-63L letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated
Rating: 245kV 18-12-2012.
Akihabara Daibiru Building, 18-13,
Soto-Kanda 1-Chome, Chiyoda-Ku, CB type: MFPTB-300-63LA,
Tokyo, 101-8608, Japan HAR/MFTB-300-563L
MITSUBISHI ELECTRIC CORPORATION 245kV GIS ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Type / Model: 200GPS
Plant -T&D Systems Center, Amagasaki
City, Japan Rating: 245kV
Website -
http://www.toshiba.co.jp/index j3.htm
Total = 8
SWITCHGEAR
10. 4
SF6 GAS INSULATED SWITCHGEAR & HYBRID SF6 GAS INSULATED SWITCHGEAR, 380 KV Applicable Standards: 32-TMSS-02
MES: ELK-TK3/420,
Operating Mechanism-ELK-BAC
CT : ELK-CN3
ALSTOM GRID SAS GIS Type test completed Previously "AREVA T&D– FRANCE-(AIX-LES
FRANCE BAINS) ", the name has been changed to
420kV GIS type T155 ALSTOM Grid SAS-France based on ALSTOM
Plant -Aix-Les Bains, France Grid-France letter # Nil, dated December 07, 2012
CB type T155, FB2T (Hydraulic
Alstom Grid Sas, 1, Rue Paul Doumer Mech.)
73100 Aix-Les-Bains (France) SUSPENDED for all SEC/National Grid SA ongoing
and forthcoming projects based on VP,
Contact Person - Mr. Zinedine RABAH, Engineering letter # 17-04473-1-30504401 dated
GIS Sales Specialist +971 (0) 56 682 July 23, 2017.
5971, ALSTOM GRID SAS, 37th Floor,
U Bora Tower, Al Abraj Street
Business Bay P.O. Box 48957, Dubai
(U.A.E.)
Phone - +33(0) 4 79 88 79 80 + 971 4
4299 651
HITACHI LTD 420kV GIS Originally JAPAN AE POWER SYSTEM CORP and
JAPAN subsequent change affected as per HITACHI
Type/ Model: IFT letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated
Rating: 420kV, 3150A @40°C, 60Hz 18-12-2012.
Akihabara Daibiru Building, 18-13,
Soto-Kanda 1-Chome, Chiyoda-Ku, CB: Double break
Tokyo, 101-8608, Japan
CB Capability:
Contact Person - Mr. Masaharu Tsumori Inductive load switching:xx
Phone - +81-3-4564-4741 Capacitor bank back to back
Email ID - Switching:xx
masaharu.tsumori.gx@hitachi.com
Website - http://www.hitachi.com
HYOSUNG (HICO) 420kV GIS type HSG 426A, 63kA, CB Based on TS&SD letter #
SOUTH KOREA (Single Break) type HCHY 426A with 10-F-02299/02-03032301 dated 25/10/2010, it is
Hydraulic Mechanism, Busbar DS type pre-qualified for 420kV GIS with the following
Plant -Republic of Changwon, Korea HDMO 426A, Line DS type HDMO conditions:
426B,ES type HEMO 426A&H-ES type
Eric Rhie, 450, Gongdeok-Dong, HEMS 426A • Ten (10) years extended warranty for the
Mapo-Gu, Seoul , Korea HYBRID GIS: proposed 420kV GIS type HSG 426A from the
Tel:82-707-6180 420kV GIS type HSG 426A with its date of PAC of the turnkey project in case of
components, up to current rating contract award or date of delivery in case of
Contact Person - Mr. Eric Rhie Sale 3150A, 55 °C, 60Hz direct material supply order. This was confirmed
Manager & Mr. Joey W. J Kyung in writing by Hyosung Corp (Korea) through letter
Marketing Manager #HS-420GIS- 100830-1 dated 30th August 2010.
Email ID - inseock@hyosung.com
Contact Person Email ID - HYBRID GIS:Based on S&SD letter #
inseock@hyosung.com , 16-02585-02-30504401 dated April
tsing@hyosung.com 10, 2016, pre-qualified Hyosung, Korea 420kV
Website - GIS type HSG 426A with following conditions:
http://www.hyosung.co.kr/eng/index.js • Ten (10) years extended warranty from the
p?, www.hyosung.com date of PAC of the turnkey project in case of
contract award and date of delivery in case of
direct material supply order. This is applicable
from first project and subsequently reduced
yearly in case of future project. This was
confirmed by the manufacturer through letter #
HG-NG-HGIS-160221-420 dated February 21,
2016
MITSUBISHI ELECTRIC CORPORATION 420kV GIS ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Type/ Model: 400-GPS
Plant -T&D Systems Center, Amagasaki
City, Japan Rating: 420kV, 4000A @40°C, 60Hz,
63kA(1s)/164kAp
Mitsubishi Electric Corporation, Tdsc,
Marketing Department, 8-1-1 CB:
Tsukaguchi-Honmachi, Amagasaki City,
Hyogo, 661-8661, Japan CB Capability:
Inductive load switching: xx
Contact Person - Mr. Isamu Arimura Capacitor bank back to back Switching:
Phone - +81-6-6497-8289 xx
Email ID -
Arimura.Isamu@da.MitsubishiElectric.C
o.jp
Website -
http://global.mitsubishielectric.com/
Rating: 420kV
CB Capability:
Inductive load switching: xx
Capacitor bank back to back Switching:
xx
DS: 8QD1
OLD VERSION:
Type/ Model: GID CB type GSR
400R2B/GSRK, DOUBLE BREAK,
Hydraulic mechanism
Rating: 420kV
Total = 11
SWITCHGEAR
10. 5
SF6 GAS INSULATED SWITCHGEAR & HYBRID SF6 GAS INSULATED SWITCHGEAR, 550 KV Applicable Standards: 32-TMSS-02
GIS
Line DS:
ELK-TV3/550(1HC0071250M0100),
Operating
Mechanism-DH(1HC0071250M0100)
MES:
ELK-EM3/550(1HC0071250M0100),
Operating
Mechanism-DH(1HC0071250M0100)
HES:
ELK-EB3/550(1HC0071250M0100),
Operating
Mechanism-DB(1HC0071250M0100)
Cable compartment:
ELK-HK3/550(1HC0071250M0100)
CONDITION:
As per 550kV GIS type 8DQ1
WARRANTY:
As per 550kV GIS type 8DQ1
Total = 3
SWITCHGEAR
10. 6
METAL CLAD GAS INSULATED MEDIUM VOLTAGE SWITCHGEAR (11KV,13.8KV.33KV OR Applicable Standards: 32-TMSS-03
34.5KV)
SIEMENS 33kV GIS PQ Letter:
GERMANY S&SD letter # 15-0186-01-30504401, dated
Type/ Model: 8DA10 January 22, 2015 and TS&SD Letter #
Berlin, Germany 10-02461-02-03032301, dated August 31, 2010,
IC SG EA MF Rating: 36kV, 2500A @40°C, 60Hz, the manufacturer is prequalified for 36kV GAS
Wernerwerkdamm 5, 25kA(3s)/65kAp Insulated Medium Voltage SWGR Type 8DA10.
13629, Berlin, Germany
CB: 3AH49 with vacuum interrupter CONDITION:
Phone - +49 (911) 433 8321 type VSG 40040, rated current up to
Website - 2500A, 40°C, 60Hz WARRANTY:
www.siemens.com/ingenuityforlife Seven (7) years extended warranty/guarantee in
CB: 3AH49 with vacuum interrupter respect of defects due to design, manufacture,
type VS 30040 (40kA), rated current installation & workmanship from the date of
up to 2375A 40°C, 60Hz Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
CB: 3AH49 with vacuum interrupter date of delivery in case of direct material supply
type VS 30040 (40kA), rated current order, as confirmed by Siemens trough letter #
up to 2375A 40°C, 60Hz 8DA10_PQR_R1 dated 24/08/2010
CB Capability:
Capacitor bank back to back Switching:
400A with CB type 3AH49, interrupter
VSG40040
Total = 1
SWITCHGEAR
10. 7
SF6 Non-Extensible Ring Main Unit, 11 KV through 34.5 KV Applicable Standards: 32-TMSS-07
Saudi Arabia
Plant -France
Website - http://www.areva.com/
Website -
http://www.driescher.de/home/index.ht
m
Website -
http://www.schneider-electric.fr/
Website -
http://w1.siemens.com/entry/cc/en/
Website -
http://www.lucyswitchgear.com/T
Total = 9
SWITCHGEAR
10. 8
LOAD BREAK SWITCHES UPTO 34.5kV Applicable Standards:
Saudi Arabia
AREVA
FRANCE
FRITZ DRIESCHER
GERMANY
HITACHI
JAPAN
SIEMENS
GERMANY
Berlin, Germany
IC SG EA MF
Wernerwerkdamm 5,
13629, Berlin, Germany
Total = 7
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
AREVA
FRANCE
Plant -France
Website - http://www.areva.com/
HUBBELL POWER SYSTEMS, INC. Previously OHIO BRASS [The name has been
United States changed based on S&SD/P&SFD letter#
14-07802-30504401 dated October 22, 2014 and
Plant -Columbia , United States based on Hubbell Power System Grid Letter # Nil
dated October 06, 2014]
Website - http://www.jaeps.com/eng/
SIEMENS ,GERMANY
GERMANY
Germany
Website -
http://www.siemens.de/Pages/EntryPa
geRedirect.aspx
TE ENERGY / TYCO ELECTRONIC MDAE4-120 Class 4 up to 132 kV Type tested in CESI PQ Lettter
United Kingdom Lab Italy in the Based on S&SD letter # 15-09503-01-030504401,
presence of TE Witham Uk is prequalified for Surge Arrester
Plant -Witham Uk (Plant) SEC/National Grid type MDAE4-120 Class 4 up to 132 kV.
SA engineers &
Bowthorpe Emp Stevenson Road SGS Inspector on WARRANTY:
Brighton East Sussex Bn2 0Df 7th to 19th April Ten (10) years Guarantee / warranty for the in
20414 .Seal Leak respect of defects due to design, manufacture,
Contact Person - Mr. Oday M. Hindi Test on conducted installation & workmanship from the date of
Transmission Support Manager,Mr. in TYCO Electronics Provisional Acceptance Certificate (PAC) of the
Graeme Currie, Product Manager test Laboratory first turnkey project in case of contract award or
Phone - +44-0-1273-692591 (Whitam, UK) in the date of delivery in case of direct material supply
Email ID - Oday.hindi@te.com, presence of SGS order, as confirmed by the manufacturer thru
Graeme.currie@te.com Inspector and CESI letter #nil, dt: Sep 14, 2011.
representative on
15th to 16th Sep
2015.
Report, General
report No.
TE-MDAE4-120
Website -
http://www.toshiba.co.jp/index j3.htm
TRIDELTA MEIDENSHA GMBH Previously " TRIDELTA ", the name has been
GERMANY changed to TRIDELTA Meidensha GmbH -
Germany, based on TRIDELTA Meidensha GmbH
Website - http://www.tridelta.de/ Letter #Nil dated August 10, 2016.
Total = 14
CIRCUIT BREAKERS
12. 1
CIRCUIT BREAKER, SF6, DEAD TANK, 69 KV Applicable Standards: 37-TMSS-01
ABB ( T& D)
United States
Website - http://www.abb.us/
Website - http://www.areva.com/
Georgia
Website - http://
http://www.geindustrial.com/products/
static/circuitbreakers/manufacturing.ht
m
Website -
http://www.toshiba.co.jp/index j3.htm
Total = 8
CIRCUIT BREAKERS
12. 2
CIRCUIT BREAKER, SF6, DEAD TANK, ,110 - 132 KV Applicable Standards: 37-TMSS-01
ABB
SWITZERLAND
ABB ( T& D)
United States
Website - http://www.abb.us/
AREVA T&D INC. Type / Model: DT1-145FK SUSPENDED for all SEC/National Grid SA ongoing
United States and forthcoming projects based on VP,
Rating: 132kV, 2000A, 40kA Engineering letter # 13-01705-30504401 dated
Charleroi, United States March 23, 2013.
PQ Letter:
TS&SD letter # 10-02708-02-03032301 dated
25/10/2010, it is pre-qualified for 145kV Dead
Tank Circuit Breaker type DT1-145FK, 40KA,
2000A.
CONDITION:
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter as confirmed by the manufacturer thru
letter #nil, dt: 6th Mar, 2009.
Georgia
Website - http://
http://www.geindustrial.com/products/
static/circuitbreakers/manufacturing.ht
m
MITSUBISHI ELECTRIC CORPORATION Type / Model: 120-SFMT-40E ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Rating: 145kV, 40kA 2000A
Plant -T&D Systems Center, Amagasaki
City, Japan
Website -
http://www.toshiba.co.jp/index j3.htm
Total = 10
CIRCUIT BREAKERS
12. 3
CIRCUIT BREAKER, SF6, DEAD TANK, 230 KV Applicable Standards: 37-TMSS-01
Website - http://www.abb.us/
AREVA Type / Model: DT1-245 F3 SUSPENDED for all SEC/National Grid SA ongoing
United States and forthcoming projects based on VP,
Rating: 230kV, 2500A, 60Hz Engineering letter # 13-01705-30504401 dated
Plant -Charleroi , United States March 23, 2013.
CONDITION:
Di-electric test, riv test, continuous current
temperature rise test @ 2500 A, 60Hz is to be
carried out in the first batch in the presence of 3
SEC engineers and 1 IIA inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
Georgia
Website - http://
http://www.geindustrial.com/products/
static/circuitbreakers/manufacturing.ht
m
MITSUBISHI ELECTRIC CORPORATION Type / Model: 200-SFMT-40E ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Rating: 245 kV, 40kA, 3150 A
Plant -T&D Systems Center, Amagasaki
City, Japan
Website -
http://www.toshiba.co.jp/index j3.htm
Total = 7
CIRCUIT BREAKERS
12. 4
CIRCUIT BREAKER, SF6, LIVE TANK, 69 KV Applicable Standards: 37-TMSS-02
ABB
SWITZERLAND
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
AREVA
SWITZERLAND
Website - http://www.areva.com/
AREVA
FRANCE
Website - http://www.areva.com/
SIEMENS, GERMANY
GERMANY
Total = 5
CIRCUIT BREAKERS
12. 5
CIRCUIT BREAKER, SF6, LIVE TANK, 110 - 132 KV Applicable Standards: 37-TMSS-02
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
AREVA
FRANCE
Website - http://www.areva.com/
AREVA
GERMANY
Website - http://www.areva.com/
SIEMENS, GERMANY
GERMANY
Total = 4
CIRCUIT BREAKERS
12. 6
CIRCUIT BREAKER, SF6, LIVE TANK, 230 KV Applicable Standards: 37-TMSS-02
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
AREVA
FRANCE
Website - http://www.areva.com/
SIEMENS, GERMANY
GERMANY
Total = 3
HAEFELY-TRENCH ELECTRIC
CANADA
Website -
http://www.electricityforum.com/produ
cts/htg.htm
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
Total = 2
ABB HV TECHNOLOGIES
SWITZERLAND
Total = 1
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter # PSN/SCA/08022016/ 2016, dt:
06/11/2016.
AREVA
FRANCE
Plant -France
Website - http://www.areva.com/
EFACEC SISTEMAS DE ELCTRONICA, Bandariyah International Type/Model - CLP500 Institue Electro PQ Lettter
S.A Co. Ltd Tecnico Portugues Based on TS&SD letter# 09-01819-03032301
PORTUGAL 3rd Fllor, Building 3 Portugal, Labecm dated 23rd June 2009, it is prequalified for for
Mutlaq Office comple Al Laboratoriao De. RTU type CLP500 as confirming to SEC
Plant -Maia/Portugal Khobar KSA compatibbilidate specification # 38-TMSS-03, rev.0 with the
Phone - 0553712308 electromagnet ica. following condition:
Rua Eng Frederico Ulrich, Ap 3078 Email - Test Date - jan 2010,
,4471-907 Maia Portugal Maia , Portugal rrami@bandariyah.com July 2010 WARRANTY
Test Report No. - Ten (10) years extended warranty/guarantee in
Contact Person - Mr. Rui Manuel Vieira E-2009-1004.02 , respect of defects due to design, manufacture,
Phone - +35-193-9333-4874 09-12-119-022a installation & workmanship from the date of
Email ID - rvieira@efacec.com Provisional Acceptance Certificate (PAC) of the
Website - http://www.efacec.com first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
FOXBORO
AUSTRALIA
Website - http://www.foxboro.com/
Website - http://www.harris.com/view
pressrelease.aspact=lookup&pr id=318
Website - http://www.harris.com/
LSIS , PQ Lettter
SOUTH KOREA Based on TS&SD letter# 08-00492/1--03032301
dated 24th March, 2008, it is prequalified for for
Ls Tower, 127, Ls-Ro, Dongan-Gu, RTU, SOE and associated transducers with the
Anyang-Si, Gyeonggi-Do, following condition
SAT
AUSTRIA
Website -
http://w1.siemens.com/entry/cc/en/
VA TECH
AUSTRIA
Total = 14
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter # PSN/SCA/08022016/ 2016, dt:
06/11/2016.
Website - http://www.harris.com/view
pressrelease.aspact=lookup&pr id=318
LSIS , WARRANTY
SOUTH KOREA Seven (7) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Ls Tower, 127, Ls-Ro, Dongan-Gu, installation & workmanship from the date of
Anyang-Si, Gyeonggi-Do, Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
Contact Person - Mr. Je-woo, Lee date of delivery in case of direct material supply
Assistant Manager order.
Phone - +82-2-2034-4541
Email ID - jwleea@lsis.com
Website - http://www.lsis.com
Website - http://www.ronan.com/
Total = 7
Website - http://www.abb.fi/
United States
Website -
http://www.ametekpower.com/
Website - http://www.ffcpg.com.my/
Phone - +61-3-5232-4709
Email ID - amjad.aziz@jpowers.co.jp
Website -
http://www.jpowers.co.jp/english/inde
x.html
LS PREVIOUSLY LG
SOUTH KOREA
Website - http://www.lscable.com/
NEXANS
SWITZERLAND
PAN ALARM
United States
PIRELLI
GERMANY
Berlin , Germany
Website - http://
http://www.pirelli.com/splash/index.htm
l
RONAN ENGINEERING
United Kingdom
Website - http://www.ronan.com/
United Kingdom
Website -
http://www.rtkinstruments.com
SIEMENS
GERMANY
STEINER
JAPAN
Website -
http://www.steiner-binoculars.com/ind
ex.html
Total = 12
DIGSILENT GMBH
GERMANY
Website - http://www.digsilent.de/
Contact Person - Mr. Ramaswami • Ten (10) years extended warranty in respect of
Bharath defects due to design , manufacturing, installation
Phone - +204-477-0591 , and workmanship from the date of PAC of the
Email ID - email Info@erlphase.com first turnkey project (in case of contract award)
Website - http://www.erlphase.com or from the date of first delivery of direct material
supply order as confirmed by the manufacturer
through their letter # Nil dated February 19, 2014.
Website -
http://www.powertechnology.com/
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt:May 18, 2010.
Total = 4
ABB S.R.O (RFF) ABB Automation CO. Ltd. UHF Sensor Type WB3 (1HC0034454) PQ Letter:
CZECH REPUBLIC Saudi Arabia rated for 300/420 kV Based on S&SD letter # 17-03926-2-30504401
PO Box # 414: dated August 03, 2017, ABB S.R.O LBU Brno
Stetkova 1638/18,140 00 Praha 4Czech Riyadh-11383 Factory – Czech Republic is pre-qualified for
Republic-Trutnov +966 (11) 2653030, Partial Discharge Sensor (UHF Sensor) type WB3
+966504401696 (1HC0034454) rated for 300/420 kV as
Contact Person - Mr. Essam essam.bashraheel@sa.a conforming to National Grid SA specification #
Bashraheel & Mr Aref Al-Arrak bb.com 38-TMSS-07 Rev.0 with the following conditions:
Email ID -
Essam.bashraheel@sa.abb.com WARRANTY:
&Aref.alarrak@sa.abb.com •Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter #
PGHV-17-04-26/GIS-1 dated June 16, 2017.
APM TECHNOLOGIES INC Al-Abdulkarim Holding Type / Model: (PDMS) APM5000 & Test completed PQ Letter:
SOUTH KOREA Company, KSA APM2000 (Portable) S&SD letter # 14-08866-2-30504401 dated
CONTACT PERSON: with UHF sensor December 11, 2014, it is pre-qualified for Partial
Plant -Seoul, Korea Republic Of Omar M. Rovillos, Discharge Monitoring System (PDMS).
Marketing Manager (EP)
Mercedes-Benz Building 5F, 225-5, Phone: +966(3) 8277777 WARRANTY:
Nonhyeon-Dong, Gangnam-Gu, Seoul (ext: 252),Mobile: +966 Ten (10) years extended warranty/guarantee in
135-829, Korea 504 respect of defects due to design, manufacture,
E-mail: installation & workmanship from the date of
Contact Person - Mr. JAY PARK omar@aktesa.com Provisional Acceptance Certificate (PAC) of the
Phone - + 82 2 545 6286,Mobile: +82 10 first turnkey project in case of contract award or
5157 1255 date of delivery in case of direct material supply
Email ID - jaypark@apmtech.co.kr order, as confirmed by the manufacturer thru
jaypark@psdholdings.com letter #nil, dt: May 12, 2014.
Website - http://www.apmtech,co,kr
HYOSUNG (HICO) PD Monitoring System ,Type: GM-3000 Type tested in the PQ letter
SOUTH KOREA UHF Internal sensor presence of Based on S&SD letter # 15-09060-02-30504401
type HiCMS-GM-IS, external Sensors SEC/National Grid dated December 09, 2015, it is pre-qualified for
Plant -Republic of Changwon, Korea type HiCMS-GEP-S-2, SA Engineers and PDM & Sensors with the following conditions:
UHF Noise sensor third party inspector
Eric Rhie, 450, Gongdeok-Dong, Type HiCMS-GNP-S-2 at KERI –Kora Lab WARRANTY:
Mapo-Gu, Seoul , Korea during 05-12 Aug Ten (10) years Extended Guarantee / Warranty
Tel:82-707-6180 2015. from the date of PAC of first Project (in case of
contract award) or from the date of delivery for
Contact Person - Mr. Eric Rhie Sale the direct material supply order. This is applicable
Manager & Mr. Joey W. J Kyung from first project and subsequently reduced
Marketing Manager yearly in case of future project. This was
Email ID - inseock@hyosung.com confirmed, through their Letter No.
Contact Person Email ID - HS-PQ-150511-PDM-001 dated 17/07/2015.
inseock@hyosung.com ,
tsing@hyosung.com
Website -
http://www.hyosung.co.kr/eng/index.js
p?, www.hyosung.com
Hyundai Electric & Energy Systems Co. PDMS Type test completed Based on S&SD letter # 16-05296-2-30504401
Ltd Type HiPDS-G (HiDAS) dated July 28,2016, it is prequalified for On-Line
SOUTH KOREA Partial Discharge Monitoring System (PDMS) and
Internal Sensor Internal Sensor as conforming to National Grid SA
Plant -Ulsan Type HiUC-P140 Material Specification 38-TMSS-07 with the
following condition:
1000, Bangeojinsunhwan-doro,
Dong-gu, Ulsan, South Korea, •Ten (10) years extended warranty from the date
of PAC of the turnkey project in case of contract
Ulsan award and date of delivery in case of direct
material supply order, as confirmed by the
Contact Person - Mr. D. H. Choi , Mr. manufacturer through letter # S370-1504-LSH3
Jinweon Lee dated 31-07-2015.
Phone - +966-11-4644696, +82 31
8006 6836
Contact Person Email ID - Previously Hyundai Heavy Industries Co. Ltd [The
danny.choi@hyundai-electric.com , name has been changed based on P&SFD letter
leejw@hyundai-electric.com #17-04234/01-030504401 dated May 24, 2017].
Website -
http://www.hyundai-elec.com
POWER DIAGNOSTIX SYSTEMS GMBH PDM Type test completed Based on S&SD letter # 16-05170/01-30504401
GERMANY dated June 23, 2016, it is prequalified for Partial
Type PDMAR 120S, PDMAR56S, Discharge Monitoring System without UHF
Plant -. PDMCR Sensors as conforming to National Grid SA
Material Specification 38-TMSS-07 with the
Vaalser Strasse 250, D-52064 following condition:
Aachen Germany
•Ten (10) years extended warranty from the date
Contact Person - Mr. Markus Soller of PAC of the turnkey project in case of contract
Contact Person Email ID - award and date of delivery in case of direct
support@pdix.com soller@pdix.com material supply order, as confirmed by the
Website - WWW.pdix.com manufacturer through letter # Nil dated
31-03-2014.
Total = 6
ABB HV TECHNOLOGIES
SWITZERLAND
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
ELECTROTECNICA ARTECHE HNOS. Type / Model: Capacitive Voltage Test Report # 2010 PQ Letter:
S.L./ E.A.H.S.L Transformer 10 3D 0571 S&SD Letter 12-03192-02-30504001 dated
SPAIN DDB-170 February 19, 2012, pre-qualified for CVT
Capacitor Voltage Transformer up to 132 kV.
Plant -Mungia, Spain Rating:
132kV, CCVT WARRANTY:
Electrotecnica Arteche Hnos. S.L./ Ten (10) years extended warranty/guarantee in
E.A.H.S.L/ Mungia/ Spain/ Derio Bidea respect of defects due to design, manufacture,
Nº28 48100/ installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Contact Person - Mr. Roberto Antuñano first turnkey project in case of contract award or
Phone - +946011200 date of delivery in case of direct material supply
Email ID - ra@arteche.es order, as confirmed by the manufacturer thru
Website - http://www.arteche.es letter #nil, dt: jan 11, 2010.
GE
United States
Website - http://www.ge.com/
HAEFELY-TRENCH ELECTRIC
CANADA
Website -
http://www.electricityforum.com/produ
cts/htg.htm
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
Website -
http://www.passoni-villa.com
CONDITION:
All type, routine & special tests including the load
test shall be carried out on the first batch to be
supplied to SEC in securing an order in an
independent testing laboratory in the presence of
three (3) SEC engineers & one (1) approved
independent inspection agency Inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
Website - http://www.ritzusa.com/
Website - http://www.trench.at/Trench
Austria GmbH/News/Das neue
Familienmitglied - Trench Italia/
-8255-38-2-en-com-/cms.html
Total = 12
METERS
14. 1
METERING DEVICES (KILOWATT HOUR METER ENERGY METER) Applicable Standards: 40-TMSS-02
ADVANCE ELECTRONICS CO., LTD. Type (ADDAD-4) Based on the approval of Executive Director
Saudi Arabia through TS&SD Letter # 08-1105-03032301 dated
20/10/2008, this Manufacturer is pre-qualified for
Riyadh , Saudi Arabia Energy Meters Type (ADDAD-4).
ELSTER , ITS A3RAQ meters with configuration kEMA, Elster PREVIOUSLY ABB (T &D)
United States Riyadh KSA ZD3D44F00LD-16, ZD3E44F00LD-16, Engineering report
Phone - ZD3D46000LD-16. Test Date - Aug Based on S&SD Letter 12-00932-1-30504401
Plant -Raleigh, Nc,USA +966-56-666-2660 2011, Feb 2005 dated March 25, 2012, it is pre-qualified for
Email - A1860RALC meters with configuration Test Report No. - A3RAQ, A1860RALC and A1860RAL meters as
Elster Gmbh Otto-Hahn-Strasse 25 zia.shaban@its.sa ZE3KM4CF5LK-EL. 71240276-TIC confirming to SEC Specification # 40-TMSS-02,
D-68623 Lampertheim, Germany 6996-11, Rev.0 with the following condition:
Raleigh, Nc , United States A1860RAL meters with configuration PAKR-8ZNRH
ZE3KM4CF0LH-EL. Free Supply of Meter Type A3RAQ: Five (5)
Contact Person - Mr. Ali Mouslmani Revenue Meters Type A3RAQ shall be supplied
Email ID - ali.mouslmani@elster.com free of cost to SEC as confirmed through ELSTER
Website - http://www.elster.com/ letter # L1-ST12-001 dated January 21, 2012.
WARRANTY
Five (5) extended warranty/guarantee in respect
of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: 12-01-2012.
GEC MEASUREMENT
United Kingdom
Website -
http://www.gecinstruments.com/
LANDIS + GYR AG-ZUG Saudi Masar High Tech Type/Model - [(E650 (ZXD) & E850 ZXQ Test Report No. - Based on S&SD Letter 14-04075-30504401 dated
SWITZERLAND Marketing Co. Rating - Cl 0.2s Active Cl 0.5 Reactive Yes April 2014 July 01, 2014, it is pre-qualified for Revenue
Industrial City, Phase 3, Meters Type E650 (ZXD) & E850 (ZXQ)
Landis+Gyr Ag Zug/Switzerland Jeddah CR No conforming to National Grid SA specifications #
Theilerstr. 1 63O1 Zug,Switzerland. 4030118442, 40-TMSS-03, Rev.1 and 40-TMSS-02 Rev.0 with
Zug , Switzerland Phone - 0096612608 the following conditions:
0581
Contact Person - Mr. Akhlak WARRANTY
Husain,Area Manager. Ten (10) years extended warranty/guarantee in
Phone - +971 558854159 respect of defects due to design, manufacture,
Email ID - AkhIak.husain@landisgyr.com installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 30, 2014.
SIEMENS
GERMANY
WARRANTY
Five (05) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by TYCO Electronic UK
through their letter # INT-SEC-06 dated January
03, 2008 and its Amendment dated Nov 21, 2011.
Total = 8
METERS
14. 2
METERING DEVICES (AMMETER, VOLTMETER, MW, MVAR) Applicable Standards: 40-TMSS-02
AREVA
FRANCE
Plant -France
Website - http://www.areva.com/
CELSA, ITALY
ITALY
Italy
Website - http://www.celsa.com/
CEWE
SWEDEN
Website - http://www.cewe.com/
WARRANTY
ENTES (Turkey) has agreed to give SEC a
Guarantee/ Warranty on the proposed digital
meters for a period of two (02) years and eight
(08) years (for maintenance) for total of ten (10)
years from the date of PAC of the turnkey project
in case of contract award or date of delivery in
case of direct material supply order.
SCHNEIDER ELECTRIC Schneider Electric Type/Model - ION 6200 DIGITAL POWER METERS TYPE ION 6200 (0.5%
CANADA Contact Rating - upto 600V 0-5 amps 0.5 ACCURACY CLASS);
Person:Senthilkumar Kp accuracy class
Plant -Victoria, Canada senthilkumar.kp@schnei WARRANTY
der-electric.com ( and ) Ten (10) years extended warranty/guarantee in
2195 Keating Cross Road Saanichton ahm respect of defects due to design, manufacture,
British Columbia Canada V8M 2A5 installation & workmanship from the date of
Canada Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
Email ID - date of delivery in case of direct material supply
hares.habre@schneider-electric.com order.
Website -
http://www.schneider-electric.ca/
http://www/en/html/frontpage.htm
WARRANTY
Five (05) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by TYCO Electronic UK
through their letter #INT-SEC-06 dated January
03, 2008 and its Amendment dated Nov 21, 2011.
Total = 7
METERS
14. 3
AUTOMATIC METER READING (AMR) SYSTEM INTEGRATOR, AUTOMATIC METER READING Applicable Standards: 40-TMSS-03 (Rev.0)
(AMR) SYSTEM
WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery in case
of direct material supply order as confirmed
through Ideal Technical Solutions (ITS), KSA,
Riyadh letter # W1-NG01-J13-001 dated January
08, 2013 and L1-ST12-020 dated December 03,
2012.
Total = 2
METERS
14. 4
ADVANCED METERING INFRASTRUCTURE (AMI) SYSTEM INTEGRATOR, ADVANCED Applicable Standards: 40-TMSS-03 (Rev.01)
METERING INFRASTRUCTURE (AMI)
WARRANTY
Ten (10) years extended warranty in respect of
the defects due to design, manufacturing,
installation and workmanship from the date of the
Provisional Acceptance Certificate (PAC) of the
first turnkey project (in case of contract award)
and from the date of first delivery in case of
direct material supply order shall be provided as
confirmed by the manufacturer through their
letter # AES-AMI-PQA-2014/001 dated July 09,
2014.
WARRANTY
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or date of first delivery in case
of direct material supply order as confirmed
through Ideal Technical Solutions (ITS), KSA,
Riyadh letter #W1-NG01-J14-001 dated January
01,2014 and Letter#L1-NG01-J14-001 dated
December 03, 2013.
CONDITION
System Demo: Live Demo of the AMI System will
be conducted in presence of SEC/National Grid
SA Engineers on the first system to be
manufactured in SEP factory already confirmed
through Ideal Technical Solutions (ITS), KSA,
Riyadh letter #L1-NG01-J14-002, dated January
06,2014.
Riyadh WARRANTY
• Ten (10) years extended warranty in respect of
Contact Person - Mr. Bruno Stocchi the defects due to design, manufacturing,
Contact Person Email ID - installation and workmanship from the date of the
majed@sep.com.sa, Provisional Acceptance Certificate (PAC) of the
bruno@sep.com.sa first turnkey project (in case of contract award)
and from the date of first delivery in case of
direct material supply order shall be provided as
confirmed by the manufacturer through their
letter No. SEP/AMI/2015/06 dated September
15,2015.
Total = 4
METERS
14. 5
REVENUE METER Applicable Standards: 40-TMSS-03
ADVANCE ELECTRONICS CO., LTD. Energy Meters Type (ADDAD-4) Based on approval of Executive Directive for
Saudi Arabia TS&SD Letter # 08-1105-03032301 dated
20/10/2008, it is pre-qualified for Energy Meters
Riyadh , Saudi Arabia Type (ADDAD-4) as confirming to SEC
Specification # 40-TMSS-03, Rev.0
WARRANTY
Five (5) years extended warranty from the date
of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order as confirmed through
ELSTER letter # NIL dated 12-01-2012.
LANDIS + GYR AG-ZUG Revenue Meters Type E650 (ZXD) & PQ Letter
SWITZERLAND E850 (ZXQ) Based on S&SD Letter 14-04075-30504401 dated
July 01, 2014, it is pre-qualified for Revenue
Landis+Gyr Ag Zug/Switzerland Meters Type E650 (ZXD) & E850 (ZXQ)
Theilerstr. 1 63O1 Zug,Switzerland. conforming to National Grid SA specifications #
Zug , Switzerland 40-TMSS-03, and 40-TMSS-02 with the following
conditions:
Contact Person - Mr. Akhlak
Husain,Area Manager. WARRANTY
Phone - +971 558854159 Ten (10) years extended warranty from the date
Email ID - AkhIak.husain@landisgyr.com of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order. This was confirmed
by the manufacturer through their letter # Nil,
dated January 30, 2014.
Total = 5
METERS
14. 6
POWER QUALITY METER Applicable Standards: 40-TMSS-03
ELECTRO INDUSTRIES / GAUGETECH Power Quality Meters type NEXUS Yes PQ Letter
United States 1500 Based on S&SD Letter 13-00862/03-030504401
dated April 20, 2013, Electro Industries/
New York United States GaugeTech, New York, USA is pre-qualified for
Power Quality Meters type NEXUS 1500 as
conforming to National Grid SA specification #
40-TMSS-03, Rev.0, with the following
conditions:
CONDITION:
Product Support: Continuous supply and product
support of Power Quality Meters type NEXUS
1500 to all SEC/ National Grid SA approved AMR
Manufacturers for a minimum period of ten (10)
years shall be ensured as confirmed through
their letter # Nil dated January 01, 2012.
WARRANTY:
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) or from the date of first delivery
of direct material supply order as confirmed by
Electro Industries /Gauge Tech -New York, USA
through their letter # L1-NG01-J13-004 dated
January 29, 2013.
Total = 2
PROTECTIVE RELAYS
15. 1
TRANSMISSION LINE PROTECTIVE RELAYS 380/132/115/110kV Applicable Standards: 41-TMSS-01
Built in Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
4CT+4VT+12BI’s+12BO’s
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS
Ordering code:
RED670*1.2-B32X00-B10B11B21C24P
01-B1X-CB-KB-B-B6X0-D1A-CA-XE
Built in Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
Hardware:
4CT+4VT+12BI’s+12BO’s
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS
Relay Type:
RED 670
Ordering code:
RED670*1.2-B32X00-B10B11B21C24P
01-B1X-CB-KB-B-B6B6-D1A-BA-XE
Built in Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS
Relay Type:
RED 670
Ordering code:
RED670*1.2-B32X00-B10B11B21C24P
01-B1X-CB-KB-B-B6B6-D1A-CA-XE
Built in Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS
Built In Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
4CT+4VT+12BI’s+12BO’s
8CT+4VT+16BI’s+16BO’s
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS
Ordering Code:
P54631NK7M0710M
Built In Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
Hardware:
4CT+4VT+12BI’s+12BO’s
8CT+4VT+16BI’s+16BO’s
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS
Built in Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
4CT+4VT+12BI’S+12BO’S
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS
Ordering code:
L90-K03-HKH-F8L-H6L-L6U-W73(*)
Built in Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
4CT+4VT+12BI’S+12BO’S
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS
Ordering code:
L90-K05-HKH-F8L-H6L-L8N-N6D-S67-
U67-W7K(*)
Built in Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS
Relay Type:
L90
Ordering code:
L90-K05-HKH-F8L-H6L-L8N-N6D-S67-
U67-W73(*) (*)
CH2 to be attenuated to fit SDH
Built in Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS
SCHNEIDER ELECTRIC Schneider Electric EPS Type/Model - 8 Models of MICOM Test Date - April Old Comments:
United Kingdom Ltd P546 2014 PQ Letter
PO Box 89249 Riyadh Rating - 380/132/115/110 kV Based on S&SD letter # 14-040883-2-30504401
Plant -United Kingdom-Stone 11682 Saudi Arabia Ordering Code: P54631NA7M0D08M dated June 12, 2014, M/s Schneider Electric from
Phone - Built in Functions: 87L, Under current United Kingdom – stone is prequalified for MiCOM
Schneider Electric Energy Ltd Unit 9 +966-11-291-28-77 x 37,Inrush Blocking, Under / over P546 as per the following conditions:
Opal Way Stone Business Park Stone 360 Frequency 81,open conductor
St15 0Ss United Kingdom Stone , United Email - protection, Second harmonic detection, CONDITION:
Kingdom padma.raja@schneider- 21P&G, 67DEF, 79 (1 CB or 2 CB) Type tests shall be carried out on the MiCOM
electric.com controlled + 25, SEF, 50/51PH&GR / P546 relays as per new IEC 61850-10 (2012-12)
Contact Person - Mr. Paul Kerr SEF/46, 67P/ 67N ,49 Thermal edition 2 in the approved Independent Testing
Phone - +44 7917 534038 Overload, 27/59/59N, 50BF, 74 DC laboratory witnessing by three (3) National Grid
Email ID - supply supervision, 74 Trip circuit SA engineers and one (1) approved Independent
paul.kerr@schneider-electric.com supervision, CT Supervision, 60 VT Agency Inspector (IIA). All costs of witnessing
Website - Supervision, DFR/SOE / Fault Locator the tests shall be borne by the manufacturer as
http://www.schneider-electric.com Hardware: 8xCT(Ph) + 5xVT, 32 Digital per their confirmation through letter # Nil dated
Inputs, 24Digital Outputs, Protection October 23, 2013.
data interface-1 850,
Protection data interface-2 850, WARRANTY:
IEC61850, 2 x Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
port(PRP) installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
Ordering Code: P54631NL7M0D08M first turnkey project in case of contract award or
Built in Functions: 87L, Under current date of delivery in case of direct material supply
37,Inrush Blocking, Under / over order.
Frequency 81,open conductor
protection, Second harmonic detection, PQ Letter
21P&G, 67DEF, 79 (1 CB or 2 CB) Based on S&SD letter # 14-040883-2-30504401
controlled + 25, SEF, 50/51PH&GR / dated June 12, 2014, M/s Schneider Electric from
SEF/46, 67P/ 67N ,49 Thermal United Kingdom – stone is prequalified for MiCOM
Overload, 27/59/59N, 50BF, 74 DC P543 as per the following conditions:
supply supervision, 74 Trip circuit
supervision, CT Supervision, 60 VT CONDITION:
Supervision, DFR/SOE / Fault Locator Type tests shall be carried out on the MiCOM
Hardware: 8xCT(Ph) + 5xVT, 32 Digital P543 relays as per new IEC 61850-10 (2012-12)
Inputs, 24Digital Outputs, Protection edition 2 in the approved Independent Testing
data interface-1 1300, Protection data laboratory witnessing by three (3) National Grid
interface-2 850, IEC61850, 2 x SA engineers and one (1) approved Independent
port(PRP) Agency Inspector (IIA). All costs of witnessing
the tests shall be borne by the manufacturer as
Ordering Code: P54631NR7M0D08M per their confirmation through letter # Nil dated
SEF/46, 67P/ 67N ,49 Thermal United Kingdom – stone is prequalified for MiCOM
Overload, 27/59/59N, 50BF, 74 DC P841 as per the following conditions:
supply supervision, 74 Trip circuit
supervision, CT Supervision, 60 VT CONDITION:
Supervision, DFR/SOE / Fault Locator Type tests shall be carried out on the MiCOM
Hardware: 4CT+4VT+ 12BI's+12BO's, P841 relays as per new IEC 61850-10 (2012-12)
CH-1 1550nm, CH-2 850nm, IEC61850, edition 2 in the approved Independent Testing
2 x port(PRP) laboratory witnessing by three (3) National Grid
SA engineers and one (1) approved Independent
Agency Inspector (IIA). All costs of witnessing
Models of MICOM : P142 the tests shall be borne by the manufacturer as
Ordering Code: P14231NC7M0468J per their confirmation through letter # Nil dated
Built in Functions: 87L High Impedance, October 23, 2013.
95 CT bus wire supervision,
50/51PH&GR / SEF/46, 67P/ 67N , WARRANTY:
SEF,49 Thermal Overload, 27/59/59N, Ten (10) years extended warranty/guarantee in
50BF, 74 DC supply supervision, 74 respect of defects due to design, manufacture,
Trip circuit supervision, CT installation & workmanship from the date of
Supervision, 60 VT Supervision, Provisional Acceptance Certificate (PAC) of the
DFR/SOE / Fault Locator first turnkey project in case of contract award or
Hardware: 5xCT(Ph) + 3xVT, 16 Digital date of delivery in case of direct material supply
Inputs, 7Digital Outputs, IEC61850, 2 x order.
port(PRP)
Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS
Ordering code:
0411L1X6X1C7CEXH5C424XX
Built in Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
27/59/59N
50BF
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
8CT+4VT+16BI’S+16BO’S
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS
Hardware:
4CT+4VT+12BI’S+12BO’S
CH-1 1300nm, CH-2 850nm
IEC 61850,2-PORTS
Ordering code:
7SD5221-5CB99-9HK0+L0S+M0J+N7A
Built in Function:
87L(Dual Combined Slope)
21P&G(5 Zones,Quad+Mho+Bi)
67DEF with comm. Schem
79(2CBs OR 1CB controlled)+25
50/51PH&GR/SEF/46
67P/67N
49 Thermal overload
27/59/59N
50BF
74DC supply supervision
74 trip relay Coil Supervision
CT Supervision
60 VT Supervision
DFR/SOE /F locator
Hardware:
4CT+4VT+12BI’S+12BO’S
CH-1 1550nm, CH-2 850nm
IEC 61850,2-PORTS
(NEW TYPE):
Type 7SL87
Ordering code:
7SL87-P1C69289
Built-in functions:
87L Dual Combined Slop
21P&G
67DEF with Comm. Scheme
79+25
50/51PH&GR/SEF/46
67P/67N
49
27/59/59N
50BF
Inrush Blocking
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision
60VT
DFR/SOE/F locator
1/3 POLE
Hardware:
4 CT
4 VT
23 BI
22 BO
Protection Interface 1:1550nm (100km)
Type 7SL86
Ordering code:
7SL86-P1C42556
Built-in functions :
87L Dual Combined Slop
21P&G
67DEF with Comm. Scheme
79+25
50/51PH&GR/SEF/46
67P/67N
49
27/59/59N
50BF
Inrush Blocking
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision
60VT
DFR/SOE/F locator
Hardware:
4 CT
4 VT
23 BI
22 BO
Protection Interface 1:1300nm (60km)
Protection Interface 2:820nm (1.5km)
IEC61850 -PRP x 2 FO ports
Type 7SL86
Ordering code:
7SL86-P1C40594
Hardware:
4 CT
4 VT
23 BI
22 BO
Protection Interface 1:1550nm (100km)
Protection Interface 2:820nm (1.5km)
IEC61850 -PRP x 2 FO ports
Total = 6
PROTECTIVE RELAYS
15. 2
POWER TRANSFORMER PROTECTION RELAYS Applicable Standards: 41-TMSS-01
Built in Function:
87L (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
87/50 Instan Diff
50/51PH&GR all windings.
67P/67N(All windings)
27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
74 Lockout coil supervision
CT Super (All windings)
60
DFR/SOE
Hardware:
2-WINDING:
14xCT(Ph)+4xCT(Gnd)
3-WINDING:
16xcontact inputs
8xcontact outputs
IEC 61850 2-ports
Ordering code:
RET670*1.2-B40X00-A01A02D04E01P
01-B1X-C-B-KB-B-B3B3-D1A-XE
Built in Function:
87L (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
67P/67N(All windings)
27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
74 Lockout coil supervision
CT Super (All windings)
60
DFR/SOE
Hardware:
3-WINDING:
14xCT(Ph)+4xCT(Gnd)
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports
Hardware:
2-WINDING:
9xCT (Ph) + 4xCT (Gnd)
3-WINDING:
16xcontact inputs
8xcontact outputs
IEC 61850 2-ports
Ordering code:
P64532NA6M0040K
Built in Functions:
87L (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
87/50 Instantaneous Diff
50/51PH&GR all windings
67P/67N(All windings)
27/59/25
81 U/O
50 BF
49T
24
74 DC Supply Supervision.
74 Lockout coil supervision
CT Super (All windings)
60
DFR/SOE
Hardware:
3-WINDING:
15xCT(Ph)+3xCT(Gnd)
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports
GE MULTILIN
CANADA T 60
Ordering code:
Markham , Canada T60-K22-HKH-F8F-H6L-M8N-PXX-U8N-
WXX
Built in Function:
87L (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
87/50 Instan Diff
50/51PH&GR all windings.
67P/67N(All windings)
27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
74 Lockout coil supervision
CT Super (All windings)
60
DFR/SOE
Hardware:
2-WINDING:
15xCT(Ph)+5xCT(Gnd)
8xcontact inputs
4xcontact outputs
3-WINDING:
IEC 61850 2-ports
Ordering code:
T60-K22-HKH-F8F-H6L-M8N-P6T-U8N-
WXX
Built in Function:
87L (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
87/50 Instan Diff
27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
74 Lockout coil supervision
CT Super (All windings)
60
DFR/SOE
Hardware:
3-WINDING:
15xCT(Ph)+5xCT(Gnd)
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports
SCHNEIDER ELECTRIC Schneider Electric EPS Type/Model - 9 Models of MICOM P643 Old Comments:
United Kingdom Ltd + MiCOM P849 Test Date - April PQ Letter
PO Box 89249 Riyadh Rating - 380/132/115/110 kV 2014 Based on S&SD letter # 14-040883-2-30504401
Plant -United Kingdom-Stone 11682 Saudi Arabia Ordering Code: P64332QA6M0B08M + dated June 12, 2014, M/s Schneider Electric from
Phone - P84930NA6M0A08K United Kingdom – stone is prequalified for MiCOM
Schneider Electric Energy Ltd Unit 9 +966-11-291-28-77 x Built in Functions: 87T ( Dual Combined P643 + MiCOM P849 as per the following
Opal Way Stone Business Park Stone 360 Slope), 87REF (low Impedance), 87REF conditions:
St15 0Ss United Kingdom Stone , United Email - (High Impedance), 87/50 Instantaneous
Kingdom padma.raja@schneider- Diff, 50/51PH&GR All Windings, CONDITION:
electric.com 67P/67N (All Windings), 27/59/25, Type tests shall be carried out on the MiCOM
Contact Person - Mr. Paul Kerr 81U/O, 50BF, 49T, 24, 74 DC supply P643 + MiCOM P849 relays as per new IEC
Phone - +44 7917 534038 supervision, 74 Trip circuit supervision, 61850-10 (2012-12) edition 2 in the approved
Email ID - CT Super. (All Windings), 60 VT Independent Testing laboratory witnessing by
paul.kerr@schneider-electric.com Supervision, DFR/SOE, three (3) National Grid SA engineers and one (1)
Website - Hardware: 15xCT(Ph) + 3xCT(Gnd) + approved Independent Agency Inspector (IIA). All
http://www.schneider-electric.com 4xVT, 32+16 Digital Inputs, 16+16 costs of witnessing the tests shall be borne by
Digital Outputs, IEC61850, 2 x port the manufacturer as per their confirmation
(PRP) through letter # Nil dated October 23, 2013.
supervision, 74 Trip circuit supervision, approved Independent Agency Inspector (IIA). All
CT Super. (All Windings), 60 VT costs of witnessing the tests shall be borne by
Supervision, DFR/SOE, the manufacturer as per their confirmation
Hardware: 9xCT(Ph) + 3xCT(Gnd) + through letter # Nil dated October 23, 2013.
4xVT, 32+12
WARRANTY:
Digital Inputs, 16+12 Digital Outputs, Ten (10) years extended warranty/guarantee in
IEC61850, 2 x port (PRP) respect of defects due to design, manufacture,
installation & workmanship from the date of
MiCOM P142 + P849 Provisional Acceptance Certificate (PAC) of the
Ordering Code: P14231NC7M0468J + first turnkey project in case of contract award or
P84930NE6M0A08K date of delivery in case of direct material supply
Built in Functions: 87 High Impedance order.
Diff Protection, SEF, 50/51+50N/51N /
46, 49 Thermal Overload, 27/59/59N,
Breaker Failure (50BF) 74DC DC PQ Letter
SUPPLY SUPERVISION, CT Based on S&SD letter # 14-040883-2-30504401
Supervision, 67P/67N, Under / Over dated June 12, 2014, M/s Schneider Electric from
Frequency 81, Under current 37, 60VT United Kingdom – stone is prequalified for MiCOM
Supervision, DFR/SOE/F Locator 142 + MiCOM P849 as per the following
Hardware: 5xCT(Ph) + 3xVT 16+64 conditions:
Digital Inputs, 7+16 Digital Outputs,
IEC61850, 2 x port (PRP) CONDITION:
Type tests shall be carried out on the MiCOM 142
Ordering Code: P14231NC7M0468J + MiCOM P849 relays as per new IEC 61850-10
Built in Functions: 87 High Impedance (2012-12) edition 2 in the approved Independent
Diff Protection, SEF, 50/51+50N/51N / Testing laboratory witnessing by three (3)
46, 49 Thermal Overload, 27/59/59N, National Grid SA engineers and one (1) approved
Breaker Failure (50BF) 74DC DC Independent Agency Inspector (IIA). All costs of
SUPPLY SUPERVISION, CT witnessing the tests shall be borne by the
Supervision, 67P/67N, Under / Over manufacturer as per their confirmation through
Frequency 81, Under current 37, 60VT letter # Nil dated October 23, 2013.
Supervision, DFR
/SOE/F Locator WARRANTY:
Ten (10) years extended warranty/guarantee in
Hardware: 5xCT(Ph) + 3xVT , 16 Digital respect of defects due to design, manufacture,
Inputs, 7 Digital Outputs IEC61850, 2 x installation & workmanship from the date of
port (PRP) Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
Hardware:
2-WINDING:
8xcontact inputs
4xcontact outputs
3-WINDING:
15xCT(Ph)+3xCT(Gnd)
Hardware:
2-WINDING:
9xCT(Ph)+4xCT(Gnd)
3-WINDING:
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports
Ordering code:
7UT6351-5EB92-1BC1+L0S
Built in Function:
87L (dual combined slope)
87 REF (low impedance)
87 REF (High impedance)
27/59/25
81 U/O
50 BF
49T
24
74 DC supply supervision.
CT Super (All windings)
60
DFR/SOE
Hardware:
3-WINDING:
12xCT(Ph)+4xCT(Gnd)
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports
(NEW TYPE):
Type 7UT85
Ordering code:
7UT85-P1F29980
Built-in functions:
87T Dual combined slop
87REF low Impedance
87REF High Impedance
87/50 Instantaneous Diff
50/51PH&GR All Windings
67/67N All Windings
27/59/25
81U/O
50BF
49T
24
Inrush Blocking
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision
60VT
DFR/SOE
Hardware:
9 PH CT + 3 GND CT
4 VT
21 BI
28 BO
IEC61850 -PRP x 2 FO ports
Ordering code:
8IDVD4F22Z904VKL
Built in Function:
87L (dual combined slope)
87 REF (low impedance)
87/50 Instan Diff
50/51PH&GR all windings.
67N/67N(All windings)
50 BF
49T
74 DC supply supervision.
Hardware:
3-WINDING:
12xCT(Ph)+2xCT(Gnd)
16xcontact inputs
8xcontact outputs
IEC 61850 2 ports
Total = 7
PROTECTIVE RELAYS
15. 3
Double BUS-BAR Single CB 132/115/110 kV Relays Applicable Standards: 41-TMSS-01
ABB-Ludvika REB500 CU
SWEDEN Ordering code:
REB500-CU03-V76-S30-P0-B0-CA3-C
Plant -Sweden B3
Hardware:
CU: 8BI’s+8BO’s
24 PU connected to CU
IEC 61850, 2-PORTS
Ordering code:
REB500-CU03-V76-S50-P0-B0-CA3-C
B3
Built in Function:
87BB: Biased Current Differential high
speed BBP with built in check zone
CT Supervision
Intertrip facility
Selective Zone tripping and blocking
HMI
DFR/SOE
Hardware:
CU: 8BI’s+8BO’s
48 PU connected to CU
IEC 61850, 2-PORTS
:
REB500 PU
Ordering code:
REB500-BU03-C2-A40-P0-F1-BB2-IO0-
R0-OC0-BFP1-E
FP1-PD0-DR0-L0-T0+1MRB150073R00
52
Built in Function:
50BF: stage1
50BF: stage2
End fault protection with Interntrip or
Dead Zone
HMI
DFR/SOE
Hardware:
PU: 4CT+16BI’S+12BO’S
Hardware:
CU: 8BI’S+8BO’S
24 PU connected to CU
IEC 61850, 2-PORTS
MICOM P740
Ordering code:
P74331NA6M0510K
Built in Function:
50BF: stage1
CT Supervision
50/51 : Phase Over current Protection
50N/51N : Earth Fault
Intertrip facility
End fault protection with interntrip or
Dead Zone
HMI
DFR/SOE
Hardware:
PU: 4CT+16BI’s+12BO’S
IEC 61850, 2-PORTS
SIEMENS 7SS52x CU
GERMANY Ordering code:
7SS5220-4AB92-1CA0+L0R
Nonnendammallee 104, 13629 Berlin
Germany Built in Function:
87BB: Biased Current Differential high
Contact Person - Mr. Andre Holldorf speed BBP with built in check zone
Phone - +49-(30)-386-57542 50BF: stage1
Email ID - andre.holldorf@siemens.com 50BF: stage2
CT Supervision
50/51 : Phase Over current Protection
50N/51N : Earth Fault
Intertrip facility
End fault protection with interntrip or
Dead Zone
Selective Zone tripping and blocking
HMI
DFR/SOE
Hardware:
CU: 8BI’s+8BO’s
24 PU connected to CU
IEC 61850, 2-PORTS
Ordering code:
7SS5220-4AB92-1FA0+L0R
Built in Function:
87BB: Biased Current Differential high
speed BBP with built in check zone
50BF: stage1
50BF: stage2
CT Supervision
50/51 : Phase Over current Protection
50N/51N : Earth Fault
Intertrip facility
End fault protection with interntrip or
Dead Zone
Selective Zone tripping and blocking
HMI
DFR/SOE
Hardware:
CU: 8BI’s+8BO’s
48 PU connected to CU
IEC 61850, 2-PORTS
7SS52x PU
Ordering code:
7SS5231-5CA01-1AA1
*BO=6 with double contact
Built in Function:
87BB: Biased Current Differential high
speed BBP with built in check zone
50BF: stage1
50BF: stage2
CT Supervision
50/51 : Phase Over current Protection
50N/51N : Earth Fault
Intertrip facility
End fault protection with interntrip or
Dead Zone
Selective Zone tripping and blocking
HMI
DFR/SOE
Hardware:
PU: 4CT+16BI’s+12BO’S
Total = 3
PROTECTIVE RELAYS
15. 4
33kV Plain OH Feeder + UG + Incomer Relays Applicable Standards: 41-TMSS-01
ABB-Ludvika
SWEDEN REL 670
Ordering code:
Plant -Sweden REL670*1.2-A31X00-H07P01-B1X-AX-
KB-B-B6X0-D1A-XX-XE
Ludvika, Sweden
Built in Function:
Contact Person - Mr. Magnus Control & MIMIC
Johansson 21 P&GD
Phone - +46 240 783228 50N/51 P&G
Email ID - 67P/67N
magnus.s.johansson@se.abb.com 49 Thermal Overload
Website - http://www.abb.se/ Phase unbalance 46
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE
Hardware:
16 BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC
SEL SEL421
United States Ordering code:
04214611XC2X43224XXXX
Website -
http://www.selindustrial.com/ Built in Function:
Control & MIMIC
21 P&GD
50N/51 P&G
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE
Hardware:
15BI+23 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC
Hardware:
16 BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC
(NEW TYPE):
Type 7SL86
Ordering code:
7SL86- P1C69261
Built-in functions:
87L Dual Combined Slop
21P&G
67DEF with Comm. Scheme
79+25
50/51PH&GR/SEF/46
67P/67N
49
27/59/59N
50BF
Inrush Blocking
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision
60VT
DFR/SOE/F locator
Hardware:
3 PH CT+ 1 SENSITIVE GND CT
4 VT
23 BI
22BO
Protection Interface 1:1300nm (24km)
Protection Interface 2:1300nm (24km)
IEC61850 -PRP x 2 FO ports
Total = 4
PROTECTIVE RELAYS
15. 5
13.8kV Plain OH Feeder + UG + Incomer Relays Applicable Standards: 41-TMSS-01
- REF620
Ordering code:
NBFNAANNEA1XF
GE MULTILIN F650
SPAIN Ordering code:
F650-NFD-F2G1-HI-6E
Built in Function:
Control & MIMIC
50N/51 P&GD
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE
Hardware:
16BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC
Hardware:
16 BI+ 07 BO
3CT(Ph) + 1CT(GD)+3VT
IEC 61850, 2-Optical Ports PRP
Built in Function:
Control & MIMIC
50N/51 P&GD
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE
Hardware:
14BI+6 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC
SEL SEL-451
United States Ordering code:
04515611XC2X4H244XXXX
Website -
http://www.selindustrial.com/ Built in Function:
Control & MIMIC
50N/51 P&GD
67P/67N
49 Thermal Overload
Phase Unbalance 46
Undercurrent 37
27/59
Auto reclosure 79
50BF
Trip circuit Supervision 74TC
Inrush Blocking
Under/Over frequency 81
CT Supervision
60 (VT Fuse Supervision)
DFR/SOE
Hardware:
16BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC
Hardware:
15BI+07 BO
3CT(Ph)+1CT(GD)+3VT
IEC 61850,2-PORTs FIBER OPTIC
(NEW TYPE);
Type 7SL86
Ordering code:
7SL86- P1C69261
Built-in functions:
87L Dual Combined Slop
21P&G
67DEF with Comm. Scheme
79+25
50/51PH&GR/SEF/46
67P/67N
49
27/59/59N
50BF
Inrush Blocking
Supervision & Monitoring Functions:
74DC Supervision
74TC
74 Lockout Supervision
CT supervision
60VT
DFR/SOE/F locator
Hardware:
3 PH CT+ 1 SENSITIVE GND CT
4 VT
23 BI
22BO
Protection Interface 1:1300nm (24km)
Protection Interface 2:1300nm (24km)
IEC61850 -PRP x 2 FO ports
Total = 6
PROTECTIVE RELAYS
15. 6
13.8kV and 33kV Capacitor Bank Relays Applicable Standards: 41-TMSS-01
ABB-Ludvika REC670
SWEDEN Ordering code:
1MRK 002 814-AC
Plant -Sweden
Built in Function:
Ludvika, Sweden 27P
50/51 P&G
Contact Person - Mr. Magnus Undercurrent
Johansson 50 2
Phone - +46 240 783228 59B&59N
Email ID - 59 2
magnus.s.johansson@se.abb.com Harmonic Overload
Website - http://www.abb.se/ 60P&N
87V phase&neutral
67 P&G
67 2
60 VT Supervision
DFR/SOE
Hardware:
6CT+6VT+16BI’s+24BO’s
IEC 61850,2-PORTS
GE MULTILIN C70
CANADA Ordering code:
C70-K03-HKH-F8N-H6D-M8V-P67-U6D-
Markham , Canada W67
Built in Function:
27P
50/51 P&G
Undercurrent
50 2
59B&59N
59 2
Harmonic Overload
60P&N
87V phase&neutral
67 P&G
67 2
60 VT Supervision
DFR/SOE
Hardware:
6CT+6VT+16BI’s+20BO’s
IEC 61850,2-PORTS
Hardware:
6CT+6VT+15BI’s+23BO’s
IEC 61850,2-PORTS
Total = 3
PROTECTIVE RELAYS
15. 7
Tripping and Lockout Relay Applicable Standards: 41-TMSS-01
ALSTOM MVAJ
United Kingdom Ordering code:
MVAJ101RA0802A
United Kingdom
Standard Specification :
Self Reset
High Burden
Flag indication, hand reset
Upto 10 contracts (in any
configuration)(8 NO & 2 NC)
Standard Hand Reset Flag Available
Operating Time in ms. (10ms)
Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)
Ordering code:
MVAJ105RA0802A
Standard Specification :
Hand & Electrical Reset
High Burden
Flag indication, hand reset
Upto 10 contracts (in any
configuration)(8 NO & 2 NC)
Standard Hand Reset Flag Available
Operating Time in ms. (10ms)
Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)
Note-Withdrawable from Case
ELECTRO-SWITCH LOR/HR
United States Ordering code:
LOR/HR-7810F
Website -
http://www.electroswitch.com/ Standard Specification :
Hand & Electrical Reset
High Burden
Flag indication, hand reset
Upto 10 contracts (in any
configuration)(8 NO & 2 NC)
Standard Hand Reset Flag Available
Operating Time in ms. (10ms)
Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)
Ordering code:
LOR/SR-7868FD
Standard Specification :
Self Reset
High Burden
Flag indication, hand reset
Upto 10 contracts (in any
configuration)(8 NO & 2 NC)
Standard Hand Reset Flag Available
Operating Time in ms. (10ms)
Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)
RELAY MONITORING SYSTEM (RMS) Relays group of High Speed Tripping Relay , Type test witnessed PQ Letter
AUSTRALIA Companies Type: 6RJ21 by three Based on S&SD letter # 15-02815-2-030504401
P.O. Box 101709 , Ordering Code: 6RJ21-10-D-8M2B SEC/National Grid dated 30 June 2015, the manufacturer is
6 Anzed Court Mulgrave 3170 Riyadh 11665 Kingdom High Burden Tripping Relay , SA Engineers during prequalified for: High Speed Tripping Relay, Type:
Melbourne Victoria Australia Po Box of Saudi Arabia Type: 6RJ25 25th May-3rd June 6RJ21
1166 Huntingdale Tel: 00 9661 Ordering Code: 6RJ25-10-D-8M2B 2015.
4727902/4724320/47324 Test were As conforming to National Grid SA specification #
Contact Person - Mr. Alphonse 61 - Fax: 00 966 Conducted in RMS 41-TMSS-01,
Fernandez Export Manager E-Mail: Lab and Report No. Rev.0 with the following condition:
Phone - +61-3-8544-1200 thuraibi@erelaysgroup.c 19301901001 (TUV)
Email ID - rms@rmspl.com.au , om, rbakshi@erelays SEC Report#Nil WARRANTY:
Alphonse.fernandez@rmspl.com.au Dated 14-10-2014 Ten (10) years extended warranty from the date
Website - http://www.rmspl.com.au of PAC of the first turnkey project in case of
contract award and subsequently reduced
yearly (in case of future project award). and
from the date of first delivery in case of direct
material supply order. This was confirmed in
writing by the manufacturer, as confirmed by the
manufacturer thru letter #nil dt: Nov 07, 2013.
SIEMENS TR241
GERMANY Ordering code:
TR241-7PG1524-1JC60-1AF0
Berlin, Germany
IC SG EA MF Standard Specification :
Wernerwerkdamm 5, Hand & Electrical Reset
13629, Berlin, Germany High Burden
Flag indication, hand reset
Phone - +49 (911) 433 8321 Upto 10 contracts (in any
Website - configuration)(8 NO & 2 NC)
www.siemens.com/ingenuityforlife Standard Hand Reset Flag Available
Operating Time in ms. (10ms)
Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
of 5A,300V,DC 80w Resistive,40w
Inductive (L/R=0.04sec)
Note-Withdrawable from Case
TR212
Ordering code:
TR212-7PG1521-2JC60-1AF0
Standard Specification :
Self Reset
High Burden
Flag indication, hand reset
Upto 10 contracts (in any
configuration)(8 NO & 2 NC)
Standard Hand Reset Flag Available
Operating Time in ms. (10ms)
Contact Ratings:
(Make & Carry (3 sec))AC/DC:
7500VA/W with Max of 30A,300V
(Make & Carry (continuous))AC/DC:
1250VA/W with
Max of 5A,300V
(Break) AC/DC: 1250VA/W with MAX
Total = 5
PROTECTIVE RELAYS
15. 8
Short Cable - all voltage levels Applicable Standards: 41-TMSS-01
ABB-Ludvika RED670
SWEDEN Ordering code:
RED670*1.2-B32X00-C24P02-B1X-C-B-
Plant -Sweden KB-B-B6X0-D1AX-AAXXXX
-XE
Ludvika, Sweden Built in Function:
Basied diff. Protection
Contact Person - Mr. Magnus Breaker Failure (50BF)
Johansson DC Supply Supervision
Phone - +46 240 783228 50/51+50N/51N
Email ID - Current Circuit Supervision
magnus.s.johansson@se.abb.com Hardware:
Website - http://www.abb.se/ Analog Inputs (6CT+6VT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 850nm, CH-2 850nm (up to 3km)
IEC 61850 -2 Ports
Relay Type:
RED670
Ordering code:
RED670*1.2-B32X00-C24P02-B1X-C-B-
KB-B-B6X0-D1AX-BBXXXX
-XE
Built in Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (6CT+6VT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 1310nm, CH-2 1310nm (up to
80km)
IEC 61850 -2 Ports
Hardware:
Analog Inputs (5CT+4VT)
Binary Inputs – 16 Inputs
Binary Outputs 14
CH-1 820nm, CH-2 820nm (up to 1km)
IEC 61850 -2 Ports
Ordering code:
P54331NC7M0610M
Built in Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (5CT+4VT)
Binary Inputs – 16 Inputs
Binary Outputs 14
CH-1 1300nm, CH-2 1300nm (up to
50km)
IEC 61850 -2 Ports
GE L90
CANADA Ordering code:
L90-K03-HKH-F8L-H6G-L6T-N67-S67-
W77
Built in Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (3CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 820nm, CH-2 820nm (up to 1km)
IEC 61850 -2 Ports
Ordering code:
L90-K03-HKH-F8L-H6G-L6T-N67-S67-
W2B
Built in Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (3CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 1300nm, CH-2 1300nm (up to
24km)
IEC 61850 -2 Ports
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
SEL SEL411L
United States Ordering code:
0411L1X6X1C7CCXH5C424XX (2KM)
Website - Built in Function:
http://www.selindustrial.com/ Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (6CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 820nm, CH-2 820nm (up to 1km)
IEC 61850 -2 Ports
Ordering code:
0411L1X6X1C7DDXH5C424XX (24KM)
Built in Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (6CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 1300nm, CH-2 1300nm (up to
24km)
IEC 61850 -2 Ports
SIEMENS 7SD52
GERMANY Ordering code:
7SD5221-5CB99-9CJ0+L0S+M0A+N0A
Berlin, Germany
IC SG EA MF Built in Function:
Wernerwerkdamm 5, Basied diff. Protection
13629, Berlin, Germany Breaker Failure (50BF)
DC Supply Supervision
Phone - +49 (911) 433 8321 50/51+50N/51N
Website - Current Circuit Supervision
www.siemens.com/ingenuityforlife
Hardware:
Analog Inputs (3CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 820nm, CH-2 820nm (up to 1.5km)
IEC 61850 -2 Ports
Ordering code:
7SD5221-5CB99-9CJ0+L0S+M0G+N0G
Built in Function:
Basied diff. Protection
Breaker Failure (50BF)
DC Supply Supervision
50/51+50N/51N
Current Circuit Supervision
Hardware:
Analog Inputs (3CT)
Binary Inputs – 16 Inputs
Binary Outputs 24
CH-1 1300nm, CH-2 1300nm (up to
24km)
IEC 61850 -2 Ports
Total = 6
PROTECTIVE RELAYS
15. 9
High Impedance BBP for all levels Applicable Standards: 41-TMSS-01
ABB
SWEDEN REC670
Ordering code:
REC670*1.2-A30X00-A02C31P02-B1-A
A-KB-B-B6X0-D1A-XXX-XE
Built in Function:
87 3-Phase High Z Differential
(based on Voltage)
50/51N
Internal CT Bus Wire Supervision
(based on voltage )
74TC Trip circuit Supervision
External Stabilizing
Resistor
External Metrosil
External CT Shorting
Hardware:
6I+6U
24BO
16BI
IEC 61850,2-Optical Ports (PRP)
REB650
Ordering code:
1MRK006520-AD
Built in Function:
87 3-Phase High Z Differential
(based on Voltage)
50/51N
Internal CT Bus Wire Supervision
(based on voltage )
74TC Trip circuit Supervision
External Stabilizing Resistor
External Metrosil
External CT Shorting
Hardware:
6I+4U
27BO
18BI
IEC 61850,2-Optical Ports (PRP)
Hardware:
3 CT Inputs
2 Output Contacts
Ordering code:
MCAG14SSD**** *A
Built in Function:
87 3-Phase High Z Differential
(Current Base)
External CT Bus Wire Supervision
External Stabilizing Resistor
External Metrosil
External CT Shorting
Hardware:
1 CT Phase Inputs
2 Output Contacts
MFAC
Ordering code:
MFACI4S1B*0001A
Built in Function:
87 3-Phase High Z Differential.
(Based on Voltage)
External CT Bus Wire Supervision
Internal Stabilizing Resistor
External Metrosil
External CT Shorting
Hardware:
1 elements / phases voltage based
4 Output Contacts
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
SIEMENS 7SJ64
GERMANY Ordering code:
7SJ6411-5EB92-1FE0+L0S
Plant -Berlin. Germany
Built in Function:
Freyeslebenstr 1 91058 Erlangen 87 3-Phase High Z Differential
(based on current)50/51N
Contact Person - Mr. Yaser Salih Internal CT Bus Wire Supervision
Phone - +49-9131725216 (based on current )
Email ID - yaser.salih@siemens.com 74TC Trip circuit Supervision
Website - http:// External Stabilizing Resistor
http://www.siemens.de/Pages/EntryPa External Metrosil
ge Redirect.aspx External CT Shorting
Hardware:
4 CT Inputs
13BO
15BI
IEC 61850, 2-Optical Ports (PRP)
Total = 4
PROTECTIVE RELAYS
15. 10
Auxiliary Relays Applicable Standards: 41-TMSS-01
ALSTOM MVTP31
United Kingdom Ordering code:
MVTP31V1CB0751E
United Kingdom
Built in Function:
CT Supervision
Hardware:
SIEMENS AR 901
GERMANY Ordering code:
7PG1110-7AE10-0AF0
Plant -Berlin. Germany
Built in Function:
Freyeslebenstr 1 91058 Erlangen CT Shorting
Total = 4
PROTECTIVE RELAYS
15. 11
Bus Coupler and Bus Section 110 kV to 380 KV Applicable Standards: 41-TMSS-01
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
Total = 1
PROTECTIVE RELAYS
15. 12
Line 380kV CBF Applicable Standards: 41-TMSS-01
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
Total = 2
PROTECTIVE RELAYS
15. 13
380 KV LINE REACTOR Applicable Standards: 41-TMSS-01
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
Total = 1
PROTECTIVE RELAYS
15. 14
132-115-110 KV REACTOR BANK AND CAPACITOR BANK Applicable Standards: 41-TMSS-01
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
Total = 1
PROTECTIVE RELAYS
15. 15
13.8 KV CONSUMER FEEDER Applicable Standards: 41-TMSS-01
Hardware:
3 PH CT+ 1 SENSITIVE GND CT
4 VT
23 BI
22 BO
Protection Interface 1:1300nm (24km)
Protection Interface 2:1300nm (24km)
IEC61850 -PRP x 2 FO ports
Total = 2
PROTECTIVE RELAYS
15. 16
Inter Trip Send/Receive 380/132/115/110kV Applicable Standards: 41-TMSS-01
Total = 1
PROTECTIVE RELAYS
15. 17
Bay Controller Unit Applicable Standards:
(New Type)
Type 6MD85
Ordering code:
6MD85-P1G33886
Built-in functions:
CONTROL & MIMIC
SYNCH Check
Metering
Interlocking
Supervision & Monitoring Functions:
CT supervision
74TC
74DC Supervision
74 Lockout Supervision
60VT
DFR/SOE
Hardware:
4 CT Measurements
4 VT
59 BI
09 BO
IEC61850 -PRP x 2 FO ports
Total = 1
AMETEK (ROCHESTER)
United States
United States
Website -
http://www.ametekpower.com
DIgSILENT Al Haider For Trading & PFM 300 Type tests were Letter
GERMANY Contracting conducted in Based on S&SD letter # 16-10016-030504401
P.O. Box 18. Ras DigSILENT test lab dated December 25, 2016, DIgSILENT,
Plant -Gomaringen Germany Tanura, 31941,m KSA and S-Team Gomaringen Germany is pre-qualified for Digital
+966 3 667 0552 / 667 Electronic test lab Fault Recorder type PFM 300 as conforming to
Heinrich-Hertz-Strabe 9 3700 / 667 1660 during 21st to 23rd National Grid SA specification # 41-TMSS-02
72810 Gomaringen alhaiderpersonnel@yaho September 2016 Rev.0, with the following condition:
o.com /
Contact Person - Dr. Martin Schmieg, salahf4@yahoo.com warranty
Managing Director •Ten (10) years extended warranty from the date
Contact Person Email ID - of PAC of the first turnkey project (in case of
m.schmieg@digsilent.de contract award) and date of first delivery (in
Website - http://www.digsilent.de case of direct material supply order), as
confirmed, through their Letter No. Nill dated 12
August 2014 shall be applicable for all supplies to
the Company by DIgSILENT, Gomaringen
Germany
ERL PHASE POWER TECHNOLOGIES Diyar Al Mobtekroon Int. TESLA 4000 Based on S&SD letter # 15-01879/02-030504401
LTD Co.\PO Box 89109 dated April 28, 2015, the manufacturer is
CANADA Riyadh 11682 KSA prequalified to supply Fault Recorder with the
Eng. Ali Al Ameel following conditions:
74 Scurfield Blvd, Winnipeg, Mb a.alameel@diyarksa.com
Canada R3Y 1G4 info@diyarksa.com - Ten (10) years extended for the Fault recorder
from the date of PAC of the turnkey project in
Contact Person - Mr. Ramaswami case of contract award or date of delivery in
Bharath case of direct material supply order. as
Phone - +204-477-0591 , confirmed through the manufacturer letter # Nil
Email ID - email Info@erlphase.com dated 18.10.2013.
Website - http://www.erlphase.com
QUALITROL HATHAWAY
NORTHERN IRELAND
Total = 4
CAPACITOR
17. 1
SHUNT CAPACITOR BANK, 13.8KV THROUGH 380KV Applicable Standards: 43-TMSS-01
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
GRID SOLUTIONS OY LTD. Previously " Nokian Capacitors Ltd. –Finland", the
FINLAND name has been changed to Areva T&D Ltd.
–Finland based on TS&SD/ESD Letter #
Tampere , Finland 10-00145-03032301 dated January 16, 2010 and
P.O.Box 4, Kaapelikatu 3 fl-33331 Areva T&D Ltd.-Finland Letter # Nil dated January
Vehmaistenkatu 5 fl-33730 04, 2010, then the name has been changed again
to ALSTOM Grid Ltd. –Finland based on Dept Mgr,
Phone - +358 3 388311 S&SD E-mail dated February 26, 2012 and
Email ID - firstname.surname@ge.com ALSTOM Grid Ltd. letter # RN-2012-02-18 dated
Website - www.gegridsolutions.com February 18, 2012.
SAMWAH CAPACITOR CO. LTD Type / Model: Shunt Capacitor Banks PQ Letter:
KOREA, Republic of TS&SD Letter # 11-02016/01-03032301 dated
Rating: 13.8kV to 36kV Only 06/07/2011, it is pre-qualified for Substation Type
13.8kV to 36kV Only Shunt Capacitor Banks.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no.nil, dt: 12/03/2010..
Total = 7
Website - http://www.bae-berlin.de/
C&D
United States
Website - http://www.cdtechno.com/
CEAC
FRANCE
Website -
http://www.ecac-ceac.org/index.phpc
ontent=lstsmember&idMenu=1&idSMen
u=10
EXIDE
United States
Website - http://www.exide.com/
FIAMM
ITALY
Website -
http://www.fiamm.com/index.aspx
GOULD (GNB)
United States
Website - http://www.goulds.com/
HOPPECKE Cell
GERMANY 24 OPzS
Website - http://www.hoppecke.com/.
TOVARNA AKUMULATORSKIH
BATERIJ
SLOVENIA
Website - http://www.tab.si/
Website - http://tungstonepower.com/
Website - http://www.varta.com/
YUASA
JAPAN
Website -
http://www.yuasabatteries.com/
Total = 12
AEG POWER SOLUTIONS SAS Originally was SAFT Power System SAS-France
FRANCE
BENNING
FRANCE
Website -
http://www.benning.fr/Anglais/nfrance
.htm
BORRI S.P.A Sela for Power Type/Model - RTB.e The type test have PQ Letter:
ITALY Automation & Safety been conducted on S&SD Letter # 14-03226-01-030504401 dated
System Input 400 Vac 125 Vdc, 300 A June 4, 2014, pre-qualified for Battery Charger
Plant -Bibbiena(Arezzo) Italy Contact Person:Mr. Emad Output 125 Vdc battery charger at (125VDC, Type RTB.e).
Abu Samha, PO Box CETACE
Bossir S.P,A Via 8 Marzo. 2-52010 - 53146, Riyadh 11583 Laboratories, 50018 WARRANTY:
Soci-Bibbiena, Italy Phone - Scandicci (FI) – Italy Ten (10) years extended warranty/guarantee in
+966-509-23-5676 from 18/03/2014 to respect of defects due to design, manufacture,
Contact Person - Mr.Paolo como Email - power 19/03/2014. Test installation & workmanship from the date of
Phone - +39-0575-5351 ryd@selanet.com Report No. Provisional Acceptance Certificate (PAC) of the
Email ID - info@borri.it TRP _064_14, Date: first turnkey project in case of contract award or
19/03/2014. date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through letter # Nil, dated May 23,
2011.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by Braga Moro- Italy through
their letter # SEC Prequalification dated April 13,
2011.
C&D
United States
Website - http://www.cdtechno.com/
Website -
http://www.emisa.es/web/index.asp?
lang=ing
ERSKINE
United Kingdom
Website -
http://www.erskine-systems.co.uk/
EXIDE
United States
Website - http://www.exide.com/
Website - http://www.gutor.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter #Nil dated June
17, 2011.
LEVER S.R.L. 125Vdc-400A Battery Charger type Based on S&SD letter# 16-03205-02-30504401
ITALY SME 125/400/SEC dated May 08, 2016, it is prequalified for
125Vdc-400A Battery Charger type
Plant -. SME 125/400/SEC as conforming to National Grid
SA Material Specification 46-TMSS-02 with the
Viale del Lavoro , 17-37024 Arbizzano following conditions:
(VR), Italy
•Ten (10) years extended warranty from the date
Contact Person - Mr. Llamettin of PAC of first Project in case of contract award
Canimoglu ,Sales Manager or from the date of delivery for the direct material
Email ID - pedcoltd@pedco.com.sa supply order and shall be subsequently reduced
Contact Person Email ID - yearly in case of future project, as confirmed by
i.canimoglu@pedco.com.sa the manufacturer through letter#
GG/nm/28042016 dated 28-04-2016.
VERTIV Industrial System S.A.S Project Execution Previously "AEES ", the name has been changed
FRANCE Development Co. Ltd to Emerson Network Power Industrial Systems -
(PEDCO) France based on Emerson Network Power
Plant -Previously AEES & Emerson 011 4648970, 2312462, Industrial Systems letter # nil dated 12/04/2013.
Network Power Industrial System 4169319 Then, the name has been changed again to
S.A.S Mr. Ilamettin Canimoglu, VERTIV Industrial Systems S.A.S based on
pedco@pedco.com.sa VERTIV Industrial Systems S.A.S letter # nil dated
Lyon , France 29/06/2017.
Lyon
Website - www.VertivCo.com
Total = 15
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by Braga Moro- Italy through
their letter # SEC
Preq. dated April 13, 2011.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
Website - http://www.gutor.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter #Nil dated June
17, 2011.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer
Statron AG through their letter # bm dated August
13, 2012.
Total = 6
AEG POWER SOLUTIONS SAS Originally was SAFT Power System SAS-France
FRANCE
C&D
United States
Website - http://www.cdtechno.com/
Website -
http://www.chloridepower.com
FIAMM
ITALY
Website -
http://www.fiamm.com/index.aspx
GNB
United States
HAWKER LTD
United Kingdom
Website - http://www.hawker.co.uk
HOPPECKE Cell
GERMANY 260SP.HC2730
Website - http://www.hoppecke.com/.
SAB
GERMANY
Website - http://www.sab.com/
SEC
United States
Website - http://www.sec.gov/
VARTA
GERMANY
Website - http://www.varta.com/
YUASA EXIDE
United States
Website -
http://www.yuasabatteries.com/
Total = 11
AEG POWER SOLUTIONS SAS originally was SAFT Power System SAS-France
FRANCE
BENNING D220G48/BWru-TDG
FRANCE
Website -
http://www.benning.fr/Anglais/nfrance
.htm
BRAGA MORO Itea International Ltd Type / Model: BATTERY CHARGER, Prequalified for BATTERY CHARGER, 48 VDC
ITALY 2nd Floor Office No. (For Telecom Applications) (For Telecom Applications).
4036 , Al Bustan Centre
Plant -Milan , Italy Near Kingdom tower Rating: 48V DC
Olaya Riyadh
Via Canzo 4 20068 Peschiera Phone - +966504367244
Borromeo, Milano, Milan ,Italy Email -
mhmagzoub@iteaint.com
Email ID - giorgio.moro@bragamoro.com
Website - http://www.bragamoro.com/
COM 10 INTERNATIONAL PTY. LTD. Type / Model: SWITCH MODE SWITCH MODE RECTIFIERS / BATTERY
AUSTRALIA RECTIFIERS / BATTERY CHARGERS CHARGERS ONLY FOR TELECOM APPLICATION.
ONLY FOR TELECOM APPLICATION.
Alpha , Australia
Website - http://www.force10.com.au/
Website -
http://www.emisa.es/web/index.asp?
lang=ing
CONDITION:
All type, design, special & routine tests as per
SEC specifications/standards shall be carried out
on the first batch to be supplied to SEC in
securing an order in the manufacturer's
laboratory in the presence of three (3) SEC
engineers & one (1) approved independent
inspection agency Inspector as confirmed by the
manufacturer through their letter no. nil, dt:
05/02/2009.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no. nil, dt: 05/02/2009..
Website - http://www.exide.com/
Website -
http://www.harmerandsimmons.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer
Statron AG through their letter # bm dated August
13, 2012.
T.D.I Type / Model: SWITCH MODE SWITCH MODE RECTIFIERS ONLY FOR TELECOM
United States RECTIFIERS ONLY FOR TELECOM APPLICATIONS
APPLICATIONS
Website - http://www.tdipower.com/
VERTIV Industrial System S.A.S Project Execution Previously "Emerson Network Power Industrial
FRANCE Development Co. Ltd Systems", the name has been changed again to
(PEDCO) VERTIV Industrial Systems S.A.S based on
Plant -Previously AEES & Emerson 011 4648970, 2312462, VERTIV Industrial Systems S.A.S letter # nil dated
Network Power Industrial System 4169319 29/06/2017.
S.A.S Mr. Ilamettin Canimoglu,
pedco@pedco.com.sa
Lyon , France
Lyon
Website - www.VertivCo.com
Total = 11
ALCAD
SWEDEN
EMISA
SPAIN
Website -
http://www.emisa.es/web/index.asp
lang=ing
EXIDE
United States
Website - http://www.exide.com/
Website - http://www.friwo.de/
WARRANTY:
Seven (07) years extended warranty/guarantee
in respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter no.nil, dt: 9th June, 2008..
GNB
United States
SAFT AB •Type: SBLE up to 1660AH (updated) Cell Type SBLE have Based on S&SD letter # 15-05875-30504401
SWEDEN •Type: SBM up to 1390AH been tested for dated September 17, 2015, the prequalification of
•Type: SBH up to 920AH 1660 AH max. at the manufacturer is updated for NICKEL
Plant -Oskarshamn/ Sweden SAFT AB on Feb. CADMIUM (NiCd) BATTERY .
20, 2015. Report No. Previously " SAFT-NIFE, Sweden", the name has
Saft Ab, Jungnergatan,P.O. Box 709, REP 0927 been changed to SAFT AB, Sweden, based on
Se-572 28 Oskarshamn Sweden SAFT AB Letter #Nil dated January 25, 2016.
Website - http://www.varta.com/
VERTIV Industrial System S.A.S Project Execution Previously "CHOLORIDE ", the name has been
FRANCE Development Co. Ltd changed to Emerson Network Power Industrial
(PEDCO) Systems - France based on Emerson Network
Plant -Previously AEES & Emerson 011 4648970, 2312462, Power Industrial Systems letter # nill dated
Network Power Industrial System 4169319 12/04/2013.
S.A.S Mr. Ilamettin Canimoglu, Then, the name has been changed again to
pedco@pedco.com.sa VERTIV Industrial Systems S.A.S based on
Lyon , France VERTIV Industrial Systems S.A.S letter # nill
dated 29/06/2017.
Lyon
Website - www.VertivCo.com
Total = 9
BRAGA MORO Itea International Ltd Type / Model: The type test PQ Letter:
ITALY 2nd Floor Office No. MDCCT conducted for Prequalified for DC-DC Converters, 48 Volts
4036 , Al Bustan Centre MDCCT BM 48V, 30 based on S&SD Letter 15-11268-01-30504401
Plant -Milan , Italy Near Kingdom Tower A, 1+1 at Tecnolab dated January 13, 2016.
Olaya Riyadh in Verbania, Italy
Via Canzo 4 20068 Peschiera Phone - +966504367244 Rating: 48 Vdc Output from March 24 – 28, WARRANTY:
Borromeo, Milano, Milan ,Italy Email - 2014. Ten (10) years Extended Guarantee / Warranty
mhmagzoub@iteaint.com from the
Email ID - giorgio.moro@bragamoro.com date of PAC of first Project (in case of contract
Website - http://www.bragamoro.com/ award) or from
the date of delivery for the direct material supply
order. This was confirmed, through their Letter #
SEC Preq. dated April 13, 2011.
Total = 1
BELDEN / HIRSCHMANN AUTOMATION MAR 1030 / AFS 675 Series All the type tests PQ Letter
AND CONTROL GMBH MAR 1040 / AFS677 / AFR677 Series were conducted in Based on S&SD Letter # 16-07249/02-30504401
GERMANY RSP 35 / AFS 665 / RSP 30 Series Phoenix test lab and dated 28th Nov 2016, it is pre-qualified
RSR 30 / AFS655 Series Hirschmann test lab
Plant -Plant Stuttgart, 72654, during 14th April WARRANTY:
Neckartenzlingen, Germany 2016 to 06th July Ten (10) years warranty shall be applicable for
2016. the models of Ethernet Switches and Routers to
Contact Person - Joy Banerji , Vertical be supplied to SEC/National Grid SA as confirmed
Account Manager - O&G and Power , through Letter #Nil dated 20.03.2015.. This has
Belden been confirmed in writing by the manufacturer;
Contact Person Email ID - through letter # AIL/BRD/ SEC/PQ/19 dated 22nd
joy.banerji@Belden.com May 2010
Website -
http://www.beldensolutions.com/
SCHWEITZER ENGINEERING Ahmad Alanezi - Ethernet Switches type SEL 2730M PQ Letter:
LABORATORIES, INC (SEL) Business Development
United States Manager & Saad Bin Based on S&SD letter # 17-04021/02-30504401
Nawaz - Sales Account dated May 28, 2017, SCHWEITZER ENGINEERING
SCHWEITZER ENGINEERING Manager LABORATORIES, INC (SEL), USA is pre-qualified
LABORATORIES, INC 2350 NE Hopkins +996556866625 for Ethernet Switches type SEL 2730M as
Court, Pullman, WA 99163 - USA ahmad_alanezi@selinc.c conforming to National Grid SA specification #
om 47-TMSS-01 with the following conditions:
Pullman Saad_Bin_nawaz@selin
c.com CONDITION:
Phone - +1.509.332.1890
Email ID - info@selinc.com First batch shall be type tested in Independent
Website - www.selinc.com Laboratory in presence of (3) SEC engineers &
(1) independent inspector. All the cost pertaining
to type test shall be borne by SCHWEITZER
ENGINEERING LABORATORIES, INC (SEL) – USA
as confirmed by the manufacturer through their
letter # LSELSA/17-020 dated May 2, 2017.
WARRANTY:
SIEMENS CANADA LIMITED RSG 2100, RSG2488 RX1500 for SAS Type test were PQ Lettter:
CANADA witnessed during Based on S&SD letter# 15-07416-030504401
19th to 26th dated October 28, 2015, it is pre-qualified for
I Ia Sc Ci Rc 300 Applewood Crescent Novmebr 2014.Test RUGGEDCOM Ethernet Switches and Routers
Concord On, L4K 5C7 Laboratories Ultra type RSG 2100, RSG 2488, RX 1500 for SAS as
Tech Oakville conforming to National Grid SA specification #
Contact Person - Mr. Mudassar Ahmed Canada and CRiQ 47-TMSS-01, with the following conditions:
Regional Sales Manager Montreal Canada
Phone - +905-856-5288 Letter Report No. WARRANTY:
Email ID - 3629159WT-03& 04 Ten (10) years Extended Warranty shall be
Mudasar.ahmed@siemens.com applicable for the RUGGEDCOM Ethernet
Website - http://www.siemens.ca Switches and Routers type RSG 2100, RSG
2488, RX 1500 for SAS, to be supplied
toSEC/National Grid SA as confirmed through
Letter # Nil dated 26.08.2014.
Total = 3
SIEMENS CANADA LIMITED RSG2100 RX1500 for metering System. Type test were PQ Lettter:
CANADA witnessed during Based on S&SD letter# 15-07416-030504401
19th to 26th dated October 28, 2015, it is pre-qualified for
I Ia Sc Ci Rc 300 Applewood Crescent Novmebr 2014.Test RUGGEDCOM Ethernet Switches and Routers
Concord On, L4K 5C7 Laboratories Ultra type RSG 2100, RX 1500 for Metering System as
Tech Oakville conforming to National Grid SA specification #
Contact Person - Mr. Mudassar Ahmed Canada and CRiQ 47-TMSS-02, with the following conditions:
Regional Sales Manager Montreal Canada
Phone - +905-856-5288 Letter Report No. WARRANTY:
Email ID - 3629159WT-03& 04 Ten (10) years Extended Warranty shall be
Mudasar.ahmed@siemens.com applicable for the RUGGEDCOM Ethernet
Website - http://www.siemens.ca Switches and Routers type RSG 2100, RX 1500
for Metering System, to be supplied to
SEC/National Grid SA as confirmed through Letter
# Nil dated 26.08.2014.
Total = 1
Website -
http://www.masskablo.com/about us
company.asp?md=7
LS CABLES Previously LG
SOUTH KOREA
Plant -Gumi/Korea
Website -
http://www.mesccables.com/
RIYADH CABLES
Saudi Arabia
SAUDI CABLE
Saudi Arabia
Phone - +966-6380080
Email ID - scc@saudicable.com
Website - http://www.saudicable.com
STEINER
GERMANY
Website -
http://www.steiner-binoculars.com/ind
ex.html
TAIHAN ELECTRIC WIRE COMPANY Taihan Electric Wire Rating - 500 V Test Date - Aug KTC Korea testing Certification
SOUTH KOREA Co.,Ltd. Branch 2011
P. O. box 300201,Riyadh
Plant -Dangjin Factory Dangjin /Republic 11372, Al-Rossais
Of Korea Building, 6th Floor Office
No. 613 -
180, Simin-Daero, Dongan-Gu, Phone - 0500108547
Anyangsi, Gyeonggi-Do, Korea Korea, Email -
Republic Of jsnam@taihan.com
Total = 11
Website - http://www.afltele.com/
ALCATEL
SWEDEN
Website - http://www.alcatel.se/
B.V.TWENTSCHE KABELFABRIEK
NETHERLANDS
Website - http://www.tkf.nl/
BICC
United Kingdom
Website -
http://www.generalcable.com/General
Cable/
BRUGG TELECOM AG
SWITZERLAND
Website - http://www.brugg.com/
CORNING CABLES
United Kingdom
Website -
http://www.corningcablesystems.com/
DRAKA NK
FINLAND
Website - http://www.draka.com/
FUJIKURA LTD.
JAPAN
FURUKAWA
JAPAN
Website -
http://www.furukawa.co.jp/english/ind
ex.htm
HITACHI
JAPAN
LS PREVIOUSLY LG
SOUTH KOREA
Website - http://www.lscable.com/
Website - http://www.mefcf.com/
Website -
http://www.mesccables.com/
Website - http://www.nkf.nl/
CONDITION:
The first batch of each type of Non Metallic Fiber
Optic Cable to be supplied to SEC shall be type
tested per relevant International and SEC
Specifications in presence of three (3) SEC
Engineers and one (1) SEC approved IIA
Inspector and all cost pertaining to the test shall
be borne by the Manufacturer as confirmed
through Letter# Nil dated September 12, 2009.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no.EU.SEC.PQ.01, dt: 17th June, 2009..
PIRELLI
ITALY
PRYSMIAN TELECOM Zamil Group Holding co, Model: Test Performed at PREVIOUSLY "PIRELLI"
SPAIN Commerical Div Kinectrics Canada in
6728, 48 Cores , May, 2014
Plant -Vilanova I La Geltru/Spain Report#
K-419533-RC-0003-
Ctra. C-15,Km, 2-P.I. Masia D’En Notari R01
08800 Vilanova I La Geltru ( Spain)
RIYADH CABLES
Saudi Arabia
SIEMENS
GERMANY
SUMITOMO
JAPAN
Yokohama
Website - http://www.sei.co.jp/
Total = 23
SIEMENS PQ Lettter
Saudi Arabia Based on S&SD letter # 14-08957-02-30504401
dated 17 December 2014, the manufacturer is
Plant -Jeddah prequalified for Integration (Assembly) and
Testing of Communication Equipment from Original
Website - http://www.siemens.com.sa Equipment Manufacturer (OEM) type tested and
approved by National Grid SA as conforming to
National Grid SA specification # 48-TMSS-06,
Rev.0 with the following condition:
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #Fe/08/14 dated October 10, 2012.
Total = 3
ABB ABB Automation CO. Ltd. FOX515 Access Multiplexer KEMA Inspection Based on TADD letter# 09-0576-030225 dated
SWITZERLAND Saudi Arabia Report reference June 10, 2009, SCADA letter# SOCW/ DIV/97 and
PO Box # 414: No. 1119-17 Telecommunication Dep. letter#
Contact Person - Mr. Klaus Lohse Riyadh-11383 09-136-03040001. ABB, Switzerland is
Phone - +41 58 588 33 50 +966 (11) 2653030, FOX615 Access Multiplexer (With pre-qualified for FOX515 Access Multiplexer.
Email ID - Klaus.lohse@ch.abb.com +966504401696 OPIC1 Card)
Website - http://www.abb.ch/ essam.bashraheel@sa.a
bb.com Based on S&SD letter # 17-04894-01-30504401
dated July 18, 2017, ABB, Switzerland is
pre-qualified for FOX615 Access Multiplexer
(With OPIC1 Card) as conforming to National Grid
SA specification # 48-TMSS-06, with the
following conditions:
WARRANTY:
•Ten (10) years extended warranty/Guarantee
from the date of PAC as confirmed; through their
Letter No. 16-05762-01-030504401 dated
27/07/2016 shall be applicable for the equipment
to be supplied to SEC/National Grid SA.
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
ALCATEL
FRANCE
Website - http://www.alcatel.fr/
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #Nil dated June 18, 2014.
FUJITSU
JAPAN
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt:mar 15, 2013.
Japan-Tokyo
NORTEL
CANADA
Website - http://www.nortel.com/
PHILIPS
HOLLAND
Website -
http://www.philips.nl/index.page
TELETTRA
FRANCE
Total = 12
Turgi , France
Website - http://www.abb.fr/
LICOM
United States
Website - http://www.licom.net/
PRISM
CANADA
SIEMENS
GERMANY
Total = 4
Total = 1
Total = 2
ALCATEL-LUCENT PQ Lettter
CHINA Based on S&SD letter # 14-07395-30504401,
dated 23/10/2014, the test facility of Alcatel
Shanghai China Lucent in (Bydgoszcz, Poland) is allowed to
conduct Factory Routine test and Integration
testing of communication equipment
manufactured in Alcatel-Lucent Factory in
Shanghai China confirming to National Grid SA
requirements.
CONDITION
Based on TS&SD letter #10-03519/03-03032301
dated 17/04/2011, it is pre-qualified for Fiber
Optic Communication Terminal type
Optenix1660SM with the following conditions:
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter # ALU/172/SI/2010 dated 12/12/2010.
CONDITION
Type, Special, sample & routine tests shall be
conducted on the first batch of 1511MAX Series
to be supplied to SEC, in the presence of three
(3) SEC Engineers & one (1) SEC approved
independent inspection agency Inspector in an
independent testing laboratory. All the related
costs for witnessing the tests will be borne by
the manufacturer. This was confirmed by Alcatel
Lucent (ASB) Shanghai China through response
letter # ALU/25/SI/2011 dated 30/01/2011 and
letter # Nil dated 27/04/2011.
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: 30/01/2011.
manufacturer.
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter # 70917174/MRK/SEC dated19/02/2008G.
Total = 3
ABB AUTOMATION CO. LTD. Integration (assembly) & testing Original Equipment PQ Lettter
Saudi Arabia Facilities regarding communication manufacturers Based on S&SD letter # 15-01367-01-30504401
equipments (OEM) as type dated 8th March-2015, the manufacturer is
Plant -2Nd Industrial Area,Riyadh, tested. prequalified for the ‘Integration (Assembly) &
Testing of Communication Equipment from Original
Po Box 325841 Riyadh,11371 KSA Equipment Manufacturer (OEM) type tested &
approved by SEC/National Grid SA’ as
Contact Person - Mr. Essam conforming to National Grid SA specification #
Bashraheel, Group Vice President 48-TMSS-09, Rev.0 with the following condition:
Phone - Tel:+966-011-476-2644
Fax:+966-011-476-9622 CONDITION
Email ID - Only for Integration (Assembly) & Testing of
Essam.bashraheel@sa.abb.com Communication Equipment from Original
Equipment Manufacturer (OEM) type tested &
approved by SEC/National Grid SA.
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter # PSN/TLE/0517/09/ 2014, dt: 15/09/2014.
ALSTOM GRID AUTOMATION UNIT Integration & testing Facilities regarding Original Equipment PQ Lettter
COGELEX communication & SCADA equipment manufacturers(OEM Based on S&SD letter # 15-00240-02-30504401
Saudi Arabia ) as type tested. dated March 03 2015, the manufacturer is
prequalified for Integration (assembly) & Testing
Plant -Jeddah , Saudi Arabia of Communication & SCADA equipment as
conforming to National Grid SA specification #
PO Box 8535 Jeddah 21492 Saudi 48-TMSS-09, Rev.0 with the following conditions:
Arabia
CONDITION
Contact Person - Mr.Firas Salman ,Unit Only for integration (assembly) & testing of
Commercial Director –NMs communication & SCADA equipment from original
Phone - +966-02-6518610 ,6513476 equipment manufacturer (OEM) type tested and
Contact Person Email ID - approved by SEC/National Grid SA.
firas.salman@alstom.com
Website - http://www.Alstom.com WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter # RN-2013-12-3 NMS/1 dated December 03,
2013.
Total = 2
WARRANTY:
Seven (7) years extended warranty from the
date of PAC of the turnkey project in case of
contract award or date of delivery in case of
direct material supply order. This was confirmed
by Amwaj Telecom MFG. Co. letter dated
09/06/2010.
ERICSON
SWEDEN
Website - http://www.ericson.com/
INDUSTRIAS ARRUTI
SPAIN
Website -
http://www.grupoarruti.com/empresa.a
sp
JIANGSU ZHONGTIAN TECHNOLOGY OPGW Joint Box, Type ST up to 192 Tests performed at: PQ Letter
CO.LTD (ZTT) splices China Based on S&SD Letter # 17-02628-01-30504401
CHINA Telecommunication dated May 09, 2017it is prequalified with the
Technology Labs following condition:
Chinanantong, China (January 09-13,
2017) WARRANTY:
Report # B17X70084 Ten (10) years extended warranty from the date
of PAC of the first turnkey in case of contract
award or date of first delivery in case of direct
material supply order as confirmed through ZTT
letter # ZTT-G-2016-06-10-01 dated 10/6/2016.
NOKIA
FINLAND
Website - http://www.nokia.com/
WARRANTY:
Five (5) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #Nil, dt: June 10, 2013.
TELECT PQ Lettter
Poland Based on TS&SD letter# 09-01095-03032301
dated 18th. April 2009 for the following
Wroclaw , Poland accessories:
- Management Rack E-9000 series
- Distribution & Termination Unit LCX.
- Wall mounted unit LanLinxs.
Total = 8
ALCATEL
FRANCE
Website - http://www.alcatel.fr/
ALCATEL NV
FRANCE
AT & T
United States
Website - http://www.att.com/
ERICSON
SWEDEN
Website - http://www.ericson.com/
MITEL CORP.
CANADA
Website - http://www.mitel.com/
NORTEL
CANADA
Website - http://www.nortel.com/
NORTHERN TELECOM
CANADA
Website -
http://www.northerntelecom.com/
PHILIPS
HOLLAND
Website -
http://www.philips.nl/index.page
RAYCHEM
United States
United States-Ca
SIEMENS
GERMANY
Total = 10
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
AREVA
FRANCE
DIMAT PQ Lettter
SPAIN Based on TS&SD Letters# 09-01439-2-03032301
dated 7th July 2009 & 10-00845-1-03032301
dated April 04, 2010. It is pre- qualified for
Tele-protection Equipment type TPU-1 with the
following conditions:
WARRANTY
Five (05) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
Ljubljana WARRANTY
•Ten (10) years extended warranty in respect of
the defects due to manufacturing and
workmanship, from the date of PAC of the first
turnkey project (in case of contract award) or
date of first delivery (in case of direct material
supply order), as confirmed through their Letter
No. DTE349/14-KIP dated September 05,2014
shall be applicable.
SIEMENS
GERMANY
Berlin, Germany
IC SG EA MF
Wernerwerkdamm 5,
13629, Berlin, Germany
Total = 5
IPG PHOTONICS Al Salam Industrial & OSTP-DWDM Type Tests were PQ Lettter
United States Trdg Est Erbium Amplifier rack Mount(EAR) and conducted in VDE Based on S&SD letter # 15-05564-2-30504401
Head Office,PO Raman Amplifier Rack Mount(RAR) Germany in dated July 05, 2015, it is pre-qualified for supply,
50 Old Webster Road Oxford Ma01540 Box:17176 presence of three installation and configuration of Optical Service
T 508 373 1100 F 508.373.1101 Jeddah-21484 Saudi SEC/National Grid Transport Platform (OSTP-DWDM), Erbium
Arabia SA Engineers during Amplifier rack Mount (EAR) and Raman Amplifier
Contact Person - Mr. Mark Cannata Tel: +966 12 608 1028 8th to 19th Rack Mount (RAR) manufactured by IPG
Director & Marketing &Mr. Yasser Fax: +966 12 608 1035 December Photonics, Oxford, Massachusetts, USA plant as
Adnan Skik yasserad@electroi.com 2014.Three Failed conforming to National Grid SA specification #
Website - test (EMC Emission 48-TMSS-08 with following condition:
http://www.ipgphotonics.com of
Enclosure,Dielectric/I WARRANTY
nsulation Resistance Ten (10) years Extended Warranty as confirmed
and Mechanical through
Operation tests) IPG Letter # NIL dated 2nd April 2014 shall be
were repeated applicable for all supplies made to the Company
during 13th to 17th by IPG Photonics Oxford, Massachusetts, USA.
April 2015.Test Lab
RMS and Type Test
Report # MI-1220-4
dated 09-05-2011
IPG PHOTONICS Al Salam Industrial & OSTP-DWDM Type Tests were PQ Lettter
ITALY Trdg Est Erbium Amplifier rack Mount(EAR) and conducted in VDE Based on S&SD letter # 15-05564-3-30504401
Head Office,PO Raman Amplifier Rack Mount(RAR) Germany in dated July 05, 2015, it is pre-qualified for supply,
50 Old Webster Road Oxford Ma01540 Box:17176 presence of three installation and configuration of Optical Service
T 508 373 1100 F 508.373.1101 Jeddah-21484 Saudi SEC/National Grid Transport Platform (OSTP-DWDM), Erbium
Arabia SA Engineers during Amplifier rack Mount (EAR) and Raman Amplifier
Contact Person - Mr. Mark Cannata Tel: +966 12 608 1028 8th to 19th Rack Mount (RAR) manufactured by IPG
Director & Marketing &Mr. Yasser Fax: +966 12 608 1035 December Photonics, Milan Italy conforming to National Grid
Adnan Skik yasserad@electroi.com 2014.Three Failed SA specification # 48-TMSS-08 with following
Website - test (EMC Emission condition:
http://www.ipgphotonics.com of
Enclosure,Dielectric/I WARRANTY
nsulation Resistance Ten (10) years Extended Warranty as confirmed
and Mechanical through
Operation tests) IPG Letter # NIL dated 2nd April 2014 shall be
were repeated applicable for allSupplies made to the Company
during 13th to 17th by IPG Photonics Milan Italy.
April 2015. Type
Test
Report#MI-1220-4
dated 09-05-2011
Total = 2
ABB ( T& D)
United States
Website - http://www.abb.us/
ABB EJF
CZECH REPUBLIC
Website -
http://www.abb.com/substation-autom
ation
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 11, 2010.
ELEQ B.V. Hamid Nazar Malik Up to 380 kV Type Test were PQ Lettter
GERMANY Contracting Co. Ltd ( Split core and continuous Ring type witnessed Based on S&SD letter# 15-10406-01-30504401,
HNCC) CTs successfully by dated
Zweigniederlassung Deutschland , Contact Person:Mr. umer SEC/ National Grid December 10, 2015. the manufacturer is
Karl-Ferdinand-Braun-Strabe 150170 Shaikh, P.O.Box 132631 SA engineers during prequalified for Split Core and Continuous Ring
Kerpen Germany Jeddah 21382,Kingdom 20th to 24th October type CTs up to 380kV as conforming to National
of Saudi 2015 in IPH Germany Grid SA 50-TMSS-01 Rev.0 with the following
Contact Person - Dr. Andreas Roos, Arabia,http://hnccsa.com Type Test Report, condition
General Manager / SGS Germany
Phone - +49-0-2273-988-70 Tel : 00966 2 ref#3534308-10 WARRANTY:
Email ID - Andreas.roos@eleq.com 6752400,Tel : 00966 2 Ten (10) years Extended Warranty shall be
Website - http://www.eleq.com 6758838, Mobil applicable for Split Core and Continuous Ring
Email : type CTs up to 380kV to be supplied to
info@hnccsa.com,sales SEC/National Grid SA as confirmed through Letter
@hnccsa.com # Nil dated 05.08.2015.
GE
United States
Website - http://www.ge.com/
Website - http://www.kuhlman.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no.MEMF/YS/LET/08/180, dt: 21st Sep,
2008...
Website - http://www.pfiffner.com/
SIEMENS
United States
Website -
http://www.usa.siemens.com/entry/en/
Total = 12
ABB ( T& D)
United States
Website - http://www.abb.us/
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
Website - http://
http://www.alstom.com/home/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
TYPE TEST SHALL BE DONE AT AN INTL.
TESTING LAB IN PRESENCE OF 3RD PARTY
INSPECTOR
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
AREVA
United Kingdom
Website - http://www.areva.com/
E. PFIFFNER
SWITZERLAND
Website -
http://www.pmw.ch/default.htm
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: Jan 11, 2010.
WARRANTY
Ten (10) years Extended Warranty shall be
applicable for Split Core and Continuous Ring
type CTs up to 380kV to be supplied to
SEC/National Grid SA as confirmed through Letter
# Nil dated 05.08.2015.
GE
United States
Website - http://www.ge.com/
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
Website - http://www.pfiffner.com/
Website - http://www.sadtem.com/
SIEMENS
United States
Website -
http://www.usa.siemens.com/entry/en/
Website - http://www.trench.at/Trench
Austria GmbH/News/Das neue
Familienmitglied - Trench Italia/
-8255-38-2-en-com-/cms.html
Total = 19
ABB ( T& D)
United States
Website - http://www.abb.us/
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
Website - http://
http://www.alstom.com/home/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All Type, Special, Routine tests per SEC
Standards shal be performed on the first batch,
at anaccredited testing laboratory in the
presence of 03 SEC/National Grid SA engineers
and one approved third party inspector and the
cost of which shall be borne by the
manufacturer.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
AREVA
United Kingdom
Website - http://www.areva.com/
ELECTROTECNICA ARTECHE HNOS. Type / Model: Current transformer Tests done in LCOE PQ Letter:
S.L./ E.A.H.S.L Laboratoty (Spain) Based on S&SD letter # 16-010639-030504401
SPAIN •Type CA-170 in presence of dated February 16,2017, Electrotecnica Arteche,
Rating: 110 kV SEC/National Grid Spain-Mungia is pre-qualified for 110 kV CTS as
Plant -Mungia, Spain SA Engineers from conforming to National Grid SA specification #
11th to 19th July, 50-TMSS-01, with the following condition:
Electrotecnica Arteche Hnos. S.L./ 2016).
E.A.H.S.L/ Mungia/ Spain/ Derio Bidea •Ten (10) years extended warranty from the date
Nº28 48100/ of PAC of the first turnkey project (in case of
contract award) or date of first delivery (in case
Contact Person - Mr. Roberto Antuñano of direct material supply order), as confirmed
Phone - +946011200 through Electrotecnica Arteche letter # NIL dated
Email ID - ra@arteche.es January 11, 2010 G.
Website - http://www.arteche.es
WARRANTY
Ten (10) years Extended Warranty shall be
applicable for Split Core and Continuous Ring
type CTs up to 380kV to be supplied to
SEC/National Grid SA as confirmed through Letter
# Nil dated 05.08.2015.
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
Website - http://www.kuhlman.com/
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
Website - http://www.pfiffner.com/
Website - http://www.sadtem.com/
TRENCH ITALIA Type / Model: OIL TYPE PREVIOUSLY AS VA TECH (NOUVA MAGRINI
ITALY GALILEO);
Website - http://www.trench.at/Trench
Austria GmbH/News/Das neue
Familienmitglied - Trench Italia/
-8255-38-2-en-com-/cms.html
Total = 16
ABB ( T& D)
United States
Website - http://www.abb.us/
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
Website - http://
http://www.alstom.com/home/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
AREVA
United Kingdom
Website - http://www.areva.com/
WARRANTY
Ten (10) years Extended Warranty shall be
applicable for Split Core / Ring type CTs up to
380kV to be supplied to SEC/National Grid SA as
confirmed through Letter# Nil dated 05.08.2015.
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
Website - http://www.kuhlman.com/
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
Website - http://www.pfiffner.com/
Website - http://www.sadtem.com/
TRENCH ITALIA Type / Model: OIL TYPE PREVIOUSLY AS VA TECH (NOUVA MAGRINI
ITALY GALILEO);
Website - http://www.trench.at/Trench
Austria GmbH/News/Das neue
Familienmitglied - Trench Italia/
-8255-38-2-en-com-/cms.html
Total = 14
ABB ( T& D)
United States
Website - http://www.abb.us/
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
Website - http://
http://www.alstom.com/home/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
AREVA
United Kingdom
Website - http://www.areva.com/
WARRANTY:
Ten (10) years Extended Warranty shall be
applicable for Split Core / Ring type CTs up to
380kV to be supplied to SEC/National Grid SA as
confirmed through Letter # Nil dated 05.08.2015.
- Previously KWK Messwandler
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
Website - http://www.kuhlman.com/
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector, as
confirmed by the manufacturer through their
letter no.CH-5042 Hirchthal, dt: 17th May, 2009..
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter no.CH-5042 Hirchthal, dt: 17th May,
2009...
Website - http://www.sadtem.com/
Website - http://www.trench.at/Trench
Austria GmbH/News/Das neue
Familienmitglied - Trench Italia/
-8255-38-2-en-com-/cms.html
Total = 14
ABB ( T& D)
United States
Website - http://www.abb.us/
ABB EJF
CZECH REPUBLIC
Website -
http://www.abb.com/substation-autom
ation
Website - http://
http://www.alstom.com/home/
AREVA
United Kingdom
Website - http://www.areva.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 11, 2010.
GE
United States
Website - http://www.ge.com/
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: oct 24, 2011.
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
PFIFFNER, HIRSCHTHAL
SWITZERLAND
Website - http://www.pfiffner.com/
SIEMENS
GERMANY
Website - http://
http://www.siemens.de/Pages/EntryPa
geRedirect.aspx
Total = 14
ABB ( T& D)
United States
Website - http://www.abb.us/
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
Website - http://
http://www.alstom.com/home/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
AREVA
United Kingdom
Website - http://www.areva.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 11, 2010.
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
PFIFFNER, HIRSCHTHAL
SWITZERLAND
Website - http://www.pfiffner.com/
Total = 11
ABB ( T& D)
United States
Website - http://www.abb.us/
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
Website - http://
http://www.alstom.com/home/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order..
AREVA
United Kingdom
Website - http://www.areva.com/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 11, 2010.
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #P/900-25112010, dt: 22 mar, 2011.
Total = 11
ABB ( T& D)
United States
Website - http://www.abb.us/
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
Website - http://
http://www.alstom.com/home/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
AREVA
United Kingdom
Website - http://www.areva.com/
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
MESWANDLER
GERMANY
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
CONDITION:
All type, special, routine and sample tests as per
SEC specifications/ standards shall be carried
out on the first unit of Inductive Voltage
Transformers to be supplied to SEC in case of
securing an order in the presence of three (3)
SEC Engineers & one (1) approved independent
inspection agency Inspector in an independent
testing laboratory or at the manufacturer’s testing
laboratory. All the related costs for witnessing
the tests will be borne by the manufacturer. This
was confirmed by PFIFFNER Instrument
Transformers Ltd through letter #
P/900-17052011 dated 17 May 2011.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #P/900-25112010, dt: 22 mar, 2011.
Total = 10
ABB ( T& D)
United States
Website - http://www.abb.us/
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
Website - http://
http://www.alstom.com/home/
ALSTOM GRID, WAYNESBORO Previously RITZ- United States [The name has
United States been changed based on S&SD/P&SFD letter #
13-06262-30504401 dated December 02, 2013].
Plant -Waynesboro , United States
CONDITION:
All type, design, special & routine tests as per
SEC Specifications/standards shall be carried out
on the first batch to be supplied to SEC/National
Grid in the presence of three (3) SEC/National
Grid SA Engineers & one (1) approved
independent inspection agency Inspector.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
AREVA
United Kingdom
Website - http://www.areva.com/
HAEFELY-TRENCH ELECTRIC
SWITZERLAND
Website -
http://www.electricityforum.com/produ
cts/htg.htm
NISSIN
JAPAN
Website - http://www.nissin.co.jp/e/
Total = 8
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed through Saudi Federal
Transformers L.L.C., Riyadh letter #
SFTL/TES/545/2012 dated May 05, 2012.
Website -
http://www.sauditransformers.com/
Website - http://www.wescosa.com/
Total = 8
TRANSFORMER, SPECIALTY
23. 1
GROUNDING TRANSFORMER, 13.8KV, 33KV OR 34.5KV Applicable Standards: 52-TMSS-01
ABB
United States
Website - http://www.abb.us
ABB ( T& D)
ITALY
Website - http://www.abb.it/
ABB SECHERON,
SWITZERLAND
Geneva , Switzerland
Website - http://www.abb.ch/
CG POWER SYSTEMS
BELGIUM
Website - http://www.pauwels.com/
Website - http://www.cglonline.com/
HYOSUNG (HICO)
SOUTH KOREA
1000, Bangeojinsunhwan-doro,
Dong-gu, Ulsan, South Korea,
Ulsan
Total = 8
TRANSFORMER, SPECIALTY
23. 2
AIR CORE NEUTRAL GROUNDING REACTOR FOR 11 KV THROUGH 132 KV SYSTEM Applicable Standards: 52-TMSS-02
Total = 1
POWER TRANSFORMERS
24. 1
Power Transformer rated up to 100 MVA Applicable Standards: 53-TMSS-01
ABB ( T& D)
United States
Website - http://www.abb.us/
ABB BILBAO Type / Model: Power Transformer Based on TS&SD letter# 09-F01546/03-03032301
SPAIN dated 19th. Aug 2009, it is pre-qualified for
Rating: 132kV, 100MVA Power Transformer up to 132kV, 100MVA as
Plant -Bilbao, SPAIN confirming to SEC specification # 53-TMSS-01,
rev.0
with the following conditions:
ABB ELEKTRIK SANAYI A.S. ABB Saudi Arabia, Type / Model: ZTR CONDITION:
[PREVIOUSLY ABB ESAS] Al-Khobar Pre-Qualification & Participation for current &
TURKEY CONTACT PERSON: Rating: 132kV, 100MVA future SEC's Projects subjected to the mutual
Rasim Duran agreement between SEC & ABB dated 09 March
Plant Phone: 0554446258 2009
-Turkey-Istanbul/Kartaladdress:Esentep rasim.duran@sa.abb.co
e Mahallesi, Milangaz Cad m
Website - http://www.abb.fi/
AREVA
GERMANY
Website - http://www.areva.com/
CG ELECTRIC SYSTEMS ZRT. Type / Model: Power Transformers Based on TS&SD Letter 11-01981-1-03032301
(PREVIOUSLY GANZ TRANSELEKTRO dated July 11, 2011, it is pre-qualified for Power
ELECTRIC CO., LTD.) Rating: 132kV, 100MVA Transformers rated up to 132kV/100MVA as
HUNGARY conforming to SEC Specification #53-TMSS-01,
Rev.0, with the following condition:
Budapest , Hungary • Ten (10) years extended warranty from the
date of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order. This was confirmed
in writing by the manufacturer through their letter
# Nil dated June 15, 2010.
CG POWER SYSTEMS
BELGIUM
Website - http://www.pauwels.com/
Website - http://www.cglonline.com/
DAIHEN CORPORATION 400 MVA & Up to 230 kV Prequalified for power transformer up to 400
JAPAN MVA & Up to 230 kV
Osaka , Japan
Website -
http://www.daihen.co.jp/indexe.htm
EFACEC ENERGIA MAQUINAS E 132kV, 100MVA Pre-qualified for Power Transformers rated up to
EQUIPAMENTOS ELECTRICOS, S.A 132kV, 100MVA
PORTUGAL
Plant -Porto/Portugal
GETRA POWER S.P.A Type / Model: Power Transformer Based on S&SD Letter # 14-04523-01-03504401
ITALY dated 7th July 2014, it is pre-qualified for Power
Rating: 132kV , 100MVA Transformer up to 100MVA, 132kV as confirming
Plant -Plant Location : Marcianise (Ce) , to National Grid SA specification # 53-TMSS-01,
Italy Rev.01 with the following conditions:
• All Type, Special & Routine tests as per National
Grid SA Specifications/Standards shall be carried
out on the first unit to be supplied to National Grid
SA in an Approved Independent
Testing Laboratory and/or in the manufacturer’s
Testing Laboratory in the presence of three (03)
National Grid SA Engineers & one (01) Approved
Independent Inspection Agency (IIA) Inspector.
All the costs of which shall be borne by the
manufacturer. This was confirmed in writing by
the
manufacturer through their letter #
GPJLT/SECNG/SSD/009, dated 8th June 2014.
• WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter # GPJLT/SECNG/SSD/0010 dated 8th
June 2014.
HAWKER SIDDELEY
United Kingdom
Website -
http://www.hssaustralia.com/
HYOSUNG (HICO)
SOUTH KOREA
1000, Bangeojinsunhwan-doro,
Dong-gu, Ulsan, South Korea,
Ulsan
HYUNDAI HEAVY INDUSTRIES CO. Type / Model: for Power Transformers Based on TS&SD letter # 11-00438-03-03032301
Bulgaria dated 15/05/2011, it is prequalified for Power
Rating: 132kV, 100MVA Transformers up to 132kV, 100MVA as
Plant -Sofia, Bulgaria confirming to SEC specification # 53-TMSS-01,
Rev.0 with the following conditions:
• All type, special, routine and sample tests as
per SEC specifications/standards for Power
Transformers up to 132kV, 100MVA shall be
carried out in case of contract award or SEC
direct purchase order at SEC approved
independent laboratory or at manufacturer’s
testing laboratory in presence of three (3) SEC
Engineers and one (1) SEC approved
independent inspection agency. All the related
costs for witnessing of the tests will be borne by
the manufacturer. This was confirmed by
HHI–Bulgaria through letter # D-0353 dated
20/08/2010.
• Ten (10) years extended warranty from the
date of PAC of the turnkey project in case of
contract award or date of delivery in case of
direct material supply order. This was confirmed
by HHI–Bulgaria through letter # D-0355 dated
20/08/2010.
ILJIN ELECTRIC CO. LTD. Type / Model: for Power Transformers PQ Letter:
SOUTH KOREA Based on S&SD Letter # 12-03077-30504401
Rating: 230kV, 166.7MVA dated
Plant -Hongseong, South Korea September 15, 2012 and S&SD letter
#15-02407-02-30504401 dated June 23, 2015.
905-17, Mannyeon-ro, Hwaseong-si, ILJIN ELECTRIC Co. Ltd – Hongseong city, Korea
Gyeonggi, KOREA is prequalified for Power Transformers up to 230
kV, 166.7 MVA as conforming to
Contact Person - Mr. Jeong Kyung Woo SEC/National Grid SA Specification # 53-TMSS-01
, Mr. Jaeho Kim with the following conditions:
Phone - +82-2-707-9161
Contact Person Email ID - CONDITION:
jkwoo@iljin.co.kr , jaeho.kim@iljin.co.kr All Type, Routine and Special tests as per
Website - http://www.iljinelectric.co.kr SEC/National Grid
SA Specifications shall be conducted on the
proposed Power Transformers in the
Manufacturer's Testing Laboratory in the
presence of three (3) SEC/National Grid SA
Engineers & one (1) SEC/National Grid SA
approved Independent Inspection Agency (IIA)
Inspector. All costs of which shall be borne by
the manufacturer. This was confirmed in writing
by the manufacturer through their letter #
IL2014-11-05-01 dated November 5, 2014.
WARRANTY:
Ten (10) years extended Warranty for the
proposed Power Transformers in respect of the
defects due to design, manufacturing, installation
and workmanship from the date of the Provisional
Acceptance Certificate (PAC) of the project (in
case of contract award) and from the date of
delivery for the direct material supply order as
confirmed through the manufacturer letter # Nil
dated November 5, 2014
KONCAR D&ST INC. Type / Model: Power Transformer Pre-qualified for Power Transformers rated up to
CROATIA 132kV, 67MVA
Rating: 132kV, 67MVA
Plant -Zagreb/ Based on S&SD Letter # 14-03217-1-30504401
Croatia-Hrvatskaaddress: dated May 18, 2014, it is pre-qualified for Power
Transformer up to 67MVA, 132kV as confirming
Koncar Distribution & Special to National Grid SA specification # 53-TMSS-01,
Transformers D&St, J. Mokrovica 8; Rev.01 with the following conditions:
P.P. 100; Hr-10090 Zagreb, Croatia • All Type, Special & Routine tests as per National
Grid SA Specifications shall be carried out on the
Contact Person - Mr. Kopjar Boris first unit to be supplied to National Grid SA in the
Phone - +385 1 3783 728 Mob: + 385 Approved Independent Testing Laboratory or in
99 2110 846 the manufacturer’s Testing Laboratory in
Email ID - Boris.kopjar@koncar-dst.hr presence of three (03) National Grid SA
Website - http://www.koncar-dst.hr/ Engineers & one (01) Approved Independent
Inspection Agency (IIA) Inspector. All the costs
of which shall be borne by the manufacturer.
This was confirmed in writing by the
manufacturer through their letter # Nil, dated May
04, 2014.
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project (in case
of contract award) and from the date of first
delivery in case of direct material supply order as
confirmed by the manufacturer through their
letter # Nil dated May 04, 2014.
KONCAR POWER TRANSFORMERS Type / Model: Power Transformer Based on S&SD Letter # 14-08041-01-03504401
LTD dated 13/02/2014 & 14-08041-02-03504401
CROATIA Rating: up to 132kV, 100MVA dated 25/03/2014, it is pre-qualified for Power
Transformer up to 100MVA, 132kV as confirming
Plant -Josipa Mokrovica 6 to National Grid SA specification # 53-TMSS-01,
Rev.01 with the following conditions:
10 090 Zagreb, Coratia • All Type, Special & Routine tests as per National
Grid SA Specifications/Standards shall be carried
Contact Person - Mr. Ivan Milcic, GM out on the first unit to be supplied to National Grid
Phone - +385 1 3795 555 SA in the Approved Independent Testing
Laboratory or in the manufacturer’s Testing
Laboratory in presence of three (03) National
Grid SA Engineers & one (01) Approved
Independent Inspection Agency (IIA) Inspector.
All the costs of which shall be borne by the
manufacturer. This was confirmed in writing by
the manufacturer through their letter # Nil, dated
01-04-2014.
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project (in case
of contract award) or from the date of first
delivery in case of direct material supply order,
as confirmed by the manufacturer through their
letter # 2014/02, dated 01-04-2014 dated April
06, 2014
LIAONING - EFACEC ELECTRICAL Rating: SUSPENDED for all SEC/National Grid SA ongoing
EQUIPMENT CO., LTD (LEEEC) Up to 100MVA and forthcoming projects based on VP,
CHINA Engineering letter #13-07937-30504401 dated
December 24, 2013.
Liaoning Province , China
The old remark before suspension was:
Based on S&SD Letter 12-01675-30504401 dated
May 20, 2012. It is prequalified for Power
Transformers rated up to 100 MVA as
conforming to SEC Specification# 53-TMSS-01
with the following condition:
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order. This was confirmed
in writing by Liaoning - Efacec Electrical
Equipment Co., Ltd (LEEEC) through their letter #
Nil dated April 18, 2012.
Website - http://www.nissin.co.jp/e/
PJSC ZAPOROZHTRANSFORMATOR Type / Model: Power Transformers Based on S&SD letter# 13-07568-30504401
(ZTR) dated December 31, 2013, it is pre-qualified for
Ukraine Rating: 132kV, 100MVA Power Transformers rated up to 100MVA, 132
kV as conforming to National Grid SA
Plant -Zaporizhia , Ukraine specification # 53-TMSS-01, Rev.01, with the
following conditions:
• All Type, Special & Routine tests as per latest
National Grid SA Specifications/Standards & IEC
requirements together (with Thermal & Dynamic
short-circuit calculations per IEC 60076-5) shall
be carried out on the next unit to be supplied to
SEC/ National Grid SA in an Accredited Testing
Laboratory in the presence of three (3) National
Grid SA Engineers & one (1) National Grid SA
approved Independent Inspection Agency (IIA)
Inspector. All costs of which shall be borne by
the manufacturer. This was confirmed in writing
by the manufacturer through their letter
1/115-2261 dated August 15, 2011.
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project in case of
contract award or date of first delivery in case of
direct material supply order. This was confirmed
in writing by the manufacturer through their letter
# 1/115-2266 dated August 15, 2011.
SAUDI POWER TRANSFORMERS Type / Model: Power Transformers Type Test Certificate PQ Lettter:
COMPANY (SPTC) #B6003867 dated 24 Based on S&SD Letter # 15-04608-03-30504401
Saudi Arabia 100 MVA, 132 kV February 2017 dated August 18, 2015, It is prequalified for
Power Transformers up to 132 kV, 100 MVA,
Plant -Dammam-Saudi Arabia
CONDITION:
Po Box 6140 Dammam 32232, Building
No. 4292 Unit No. 19 , Saudi Arabia WARRANTY:
Mr. Hosam Al Shaikh, CEO Ten (10) years extended Warranty for the
Phone: +966 13 814 4622 ext 111 proposed Power Transformers rated up to 132
Fax. +966 13 814 4627 kV, 100 MVA in respect of the defects due to
Mobile: +966 50 680 3900 design, manufacturing, installation and
workmanship from the date of the Provisional
Mr. Bahaa Abduieh, Sales & Marketing Acceptance Certificate (PAC) of the project (in
Manager case of contract award) and from the date of
Phone: + +966 13 814 4622 ext 133 delivery for the direct material supply order as
Fax. +966 13 814 4627 confirmed through the manufacturer letter# CEO
Mobile: +966 50 0082841 /2015 /008 dt:Aug 8, 2015.
Email ID - ceo@sptc.com.sa,
sales@sptc.com.sa
SC ELECTROPUTERE SA Type / Model: Power Transformer ON HOLD for the procurement of Power
Romania Transformer for all ongoing and forthcoming
Rating: 132kV, 100MVA projects of company including the Eight (8) spare
Plant -Craiova, Romania transformers against purchase order #
4500217223 as per S&SD fax#
16-05458-30504401 dated 23/06/2016.
SCHNEIDER ENERJI ENDUSTRISI SAN Type / Model: Power Transformers Pre-qualified for Power Transformers rated up to
VE TIC A.S 132kV, 67MVA
TURKEY Rating: 132kV, 67 MVA Based on S&SD letter# 14-02364-1-30504401
dated April 01, 2014, it is pre-qualified for Power
Plant -Cayirova-Kocaeli-Turkey Transformers up to 67 MVA and, 132 kV
conforming to National Grid SA specification
Tosb Organize Sanayi Bölgesi 1.Cadde 53-TMSS-01, Rev. 01, with the following
No:6 Çayırova Kocaeli conditions:
• All Type, Special & Routine tests as per National
Contact Person - Mr. Orhan Unal Sales Grid SA Specifications/Standards shall be carried
Manager out on the first unit to be supplied to National Grid
Email ID - SA in the manufacturer Testing
orhan.unal@schneider-electric.com Laboratory in the presence of three (03) National
Grid SA Engineers & one (01) National Grid SA
approved Independent Inspection Agency (IIA)
Inspector. All costs of which shall be borne by
the manufacturer. This was confirmed in writing
by the manufacturer through their letter #
MKT_132KV Trafo_005, dated June 18, 2013.
• Schneider Electric Transformer Factory -
Cayirova, Istanbul, Turkey has confirmed that
“improvement needs implementation will be
complied during the FAT for the first transformer
order” confirmed through letter # MKT_132KV
Trafo_010 dated February 12, 2014.
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project (in case
of contract award) or from the date of first
delivery in case of direct material supply order as
confirmed by the manufacturer through their
letter # MKT_132KV Trafo_007-1 dated March
19, 2014.
- Previously "AREVA-Turkey", the name has
been changed to Schneider Electric-Turkey
based on Schneider Electric letter #
MKT-18.01.11 dated 18/01/2010 and AREVA T&D
letter # BF/BL25.11.2010.
SCHORCH Type / Model: Power Transformers Prequalified Power Transformer up to 33KV &
GERMANY Rating: 33KV & 34.5 KV , 30MVA 34.5 KV PRIMARY, 30MVA
Website - http://www.schorch.de/
SIEMENS AG (DRESDEN) Type / Model: Power Transformer Prequalified Power Transformer up to 230kV
GERMANY PRIMARY, 200MVA
Rating: up to 230kV, 200MVA
Website - http://www.simense.com based on TS&SD letter# 09-01501-03032301
dated 25th May 2009 , Siemens AG from
Germany-Dresden for Power Transformer up to
230kV, 200MVA as confirming to SEC
specification # 53 TMSS-01, rev.0 & 53-TMSS-02,
rev.0 with the following conditions:
SIEMENS AG (NURNBERG)
GERMANY
Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx
Weiz , Austria
Website - http://www.vatechetg.at/
Website - http://www.tamini.com/
Website -
http://www.toshiba.co.jp/index j3.htm
Melbourne , Australia
Total = 39
POWER TRANSFORMERS
24. 2
Power Transformer rated above 100 MVA Applicable Standards: 53-TMSS-01
ABB ( T& D)
United States
Website - http://www.abb.us/
ABB CORDOBA ABB Saudi Arabia, Type / Model: Power Transformer Prequalified for power transformer up to 500
SPAIN Al-Khobar MVA
CONTACT Rating: up to 380kV, 500MVA
Plant -Cordoba, Spain PERSON:Rasim Duran Based on TS&SD letter#
Phone - 0554446258 09-F011657/03-03032301 dated August 16,
Escritor Conde Zamorea, S/N ,14004 Email - 2009. It is pre-qualified for Power Transformer up
Cordoba (Spain) rasim.duran@sa.abb.co to 380kV, 500MVA as confirming to SEC
m specification # 53-TMSS-02, rev.0 with the
Contact Person - Mr. Evan Smith following conditions:
Phone - +34608749306 • All type, design, special (exclude Short-Circuit
Email ID - evan.smith@es.abb.com Test) & routine tests as per SEC
Website - Specifications/Standards together with Thermal &
http://new.abb.com/products/transform Dynamic short-circuit calculations per IEC
ers 60076-5 shall be carried out on the first unit to be
supplied to SEC in an accredited Independent
Testing Laboratory or in the manufacturer's
testing laboratory in the presence of three (3)
SEC Engineers & one (1) SEC approved
Independent Inspection Agency (IIA) Inspector.
All costs of which shall be borne by the
manufacturer. This was confirmed in writing by
the manufacturer through their letter #
PPTR-002.2 dated February 14, 2009 and the
submitted "Confirmation Letter" # Nil dated
November 18, 2008. [this condition has been
modified based on S&SD letter#
12-0395-01-30504001 dated February 12, 2012]
ABB ELEKTRIK SANAYI A.S. ABB Saudi Arabia, Type / Model: Power Transformer Prequalified for power transformer up to 250 MV
[PREVIOUSLY ABB ESAS] Al-Khobar only
TURKEY CONTACT Rating: 380kV, 250MVA
PERSON:Rasim Duran Based on S&SD letter# 14-02898/03-030504401
Plant Phone - 0554446258 dated June 17, 2014, it is pre-qualified for Power
-Turkey-Istanbul/Kartaladdress:Esentep Email - Transformer up to 380kV, 250MVA as confirming
e Mahallesi, Milangaz Cad rasim.duran@sa.abb.co to National Grid SA specification # 53-TMSS-02,
m Rev.01 with the following conditions:
Esentepe Mahallesi, Milangaz Cad No.
52 Kartal 34870, Istanbul -Turkey • All Type, Routine and Special testes as per NG
Specifications/Standards and IEC requirement
Contact Person - Mr. Sezgin Perdahci together with Thermal & Dynamic short-circuit
Phone - +90-533-666-8067 calculations per IEC 60076-5 shall be carried out
Email ID - E-mail : on the First unit to be supplied to SEC/NG of
sezgin.perdahci@tr.abb.com Power Transformers in the Manufacturer's
Website - http://www.abb.com Testing
Laboratory in the presence of three (3) SEC/NG
Engineers & one (1) SEC/ NG approved
Independent Inspection Agency (IIA) Inspector.
All costs of which shall be borne by the
manufacturer. This was confirmed in writing by
the manufacturer through their letter # Nill dated
February 04, 2013 .
• Ten (10) years extended warranty from the
date of PAC of the first turnkey project (in case
of contract award) and from the date of first
delivery in case of direct material supply order as
confirmed by the manufacturer through their
letter #Nill dated May 24, 2013.
AREVA
GERMANY
Website - http://www.areva.com/
WARRANTY:
Ten (10) years extended warranty from the date
of PAC of the first turnkey project (in case of
contract award) and date of first delivery (in
case of direct material supply order), as
confirmed, through their Letter No.
BEST-100316-SEC-01 dated 10 March 2016.
CG POWER SYSTEMS
BELGIUM
Website - http://www.pauwels.com/
DAIHEN CORPORATION 230 kV up to 400 MVA Prequalified for power transformer up to 400
JAPAN MVA & Up to 230 kV
Osaka , Japan
Website -
http://www.daihen.co.jp/indexe.htm
WARRANTY:
Six (6) years extended Warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
Old Remark
Previously AREVA T&D-Turkey [The name has
been changed based on S&SD/P&SFD letter #
12-01064-30504401 dated March 14, 2012].
HAWKER SIDDELEY
United Kingdom
Website -
http://www.hssaustralia.com/
HYOSUNG (HICO) Type / Model: Power Transformer Prequalified for power transformer up to 500
SOUTH KOREA MVA
Rating: 380kV, 500MVA
Plant -Republic of Changwon, Korea Based on TS&SD fax#09-F01255/02-03032301
dated 25th. July 2009, it is pre-qualified for
Eric Rhie, 450, Gongdeok-Dong, Power Transformer up to 380kV, 500MVA as
Mapo-Gu, Seoul , Korea confirming to SEC specification # 53-TMSS-02,
Tel:82-707-6180 rev.0
with the following conditions:
Contact Person - Mr. Eric Rhie Sale
Manager & Mr. Joey W. J Kyung • All type, design, special & routine tests as per
Marketing Manager SEC specifications/standards shall be carried out
Email ID - inseock@hyosung.com on the first batch to be supplied to SEC in
Contact Person Email ID - securing an order in the presence of three
inseock@hyosung.com , (3) SEC engineers & one (1) approved
tsing@hyosung.com independent inspection agency Inspector.
Website - • Seven (7) years warranty from the date of PAC
http://www.hyosung.co.kr/eng/index.js of the turnkey project in case of contract award
p?, www.hyosung.com or date of delivery in case of direct material
supply order.
1000, Bangeojinsunhwan-doro,
Dong-gu, Ulsan, South Korea,
Ulsan
WARRANTY:
Ten (10) years extended Warranty for the
proposed Power Transformers in respect of the
defects due to design, manufacturing, installation
and workmanship from the date of the Provisional
Acceptance Certificate (PAC) of the project (in
case of contract award) and from the date of
delivery for the direct material supply order as
confirmed through manufacturer letter # Nil dated
November 5, 2014.
KONCAR POWER TRANSFORMERS, Siemens Ltd.- Saudi up to 380kV & 500MVA Based on S&SD letter # 17-03229-05-30504401
Croatia (A joint Venture of Siemens and Arabia dated May 17, 2017, Koncar Power
Koncar) Siemens Ltd., 02nd floor, Transformers Ltd, Croatia (A joint Venture of
CROATIA Juffali Tower , P.O Siemens and Koncar) is pre-qualified for Power
Box#719, Al-Khobar Transformer rated up to 380kV & 500MVA as
Josipa Mokrovica 12, 10090 Zagreb 31952, Kingdom of Saudi conforming to National Grid SA specification #
Arabia 53-TMSS-01, with the following conditions:
Contact Person - Mr. Nidzar +966 (13) 865 9680
Turcinhodzic Kaisar.langoo@siemens. •Ten (10) years extended warranty from the date
Phone - +38513794075 com of PAC of the project (in case of contract award)
Email ID - Kpt.hr@siemens.com or date of delivery (in case of direct material
Contact Person Email ID - supply order), as confirmed, through their Letter
Nidzar.turcinhodzic@siemens.com No. NIL dated June 6, 2016 shall be applicable for
Website - http://www.koncar-dst.hr/ all Power Transformers rated up to 380kV &
500MVA to be supplied to SEC/National Grid SA.
MITSUBISHI ELECTRIC CORPORATION Type/Model - Shell type ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
SIEMENS AG (DRESDEN) Type / Model: Power Transformer Prequalified for Power Transformer up to 230kV,
GERMANY 200MVA
Rating: up to 230kV, 200MVA
Website - http://www.simense.com based on TS&SD letter# 09-01501-03032301
dated 25th May 2009 , Siemens AG from
Germany-Dresden for Power Transformer up to
230kV, 200MVA as confirming to SEC
specification # 53-TMSS-01, rev.0 &
53-TMSS-02, rev.0 with the following conditions:
• All type, special & routine tests for each voltage
class as per SEC specifications/standards shall
be carried out on the first batch to be supplied to
SEC in securing an order in the presence
of three (3) SEC engineers & one (1) approved
independent inspection agency Inspector.
• Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award
or date of delivery in case of direct material
supply order.
SIEMENS AG (NURNBERG)
GERMANY
Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx
Weiz , Austria
Website - http://www.vatechetg.at/
Website -
http://www.toshiba.co.jp/index j3.htm
Total = 21
WARRANTY:
Five (05) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by the manufacturer through
their letter no.SSG/SEC/11, DT: 20TH April, 2007
Website - http://www.chemtrade.com
NYNAS
SWEDEN
Website -
http://www.nynas.com/default.aspx?
epslanguage=EN
SAVITA
INDIA
Website - http://www.savita.com/
SHELL Type / Model: Previously Shell (France), The location has been
GERMANY The acceptable mineral oil type is Shell changed to Hamburg, Germany Based on the
Diala Type S2-ZU-I. manufacturer email dated 19/08/2013.
Hamburg , Germany
Website - http://www.shell.com/
Total = 6
RESISTOR
26. 1
NEUTRAL GROUNDING RESISTOR, 11 KV THROUGH 34.5 KV Applicable Standards: 57-TMSS-01
CRESSAL RESISTOR
United Kingdom
Website - http://www.cressall.com/
FURSE
United Kingdom
Website -
http://www.furse.com/home.htm
M.S.RESISTANCES WARRANTY:
FRANCE Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
Website - installation & workmanship from the date of
http://www.msresistances.com Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
METAL DEPLOYE
FRANCE
Website -
http://www.metaldeploye.com
NATIONAL
INDIA
Total = 5
REACTOR
27. 1
OIL IMMERSED REACTORS, (33 KV TO 69 KV ) Applicable Standards: 58-TMSS-01
Website - http://www.areva.com/
CONDITION:
All Type, Special & Routine tests as per latest
National Grid SA Specifications & IEC
requirements [excluding Short circuit test ] shall
be carried out on the first unit to be supplied to
SEC/National Grid SA in the manufacturer
Laboratory in the presence of three (3) National
Grid SA Engineers & one (1) National Grid SA
approved Independent Inspection Agency (IIA)
Inspector. All costs of which shall be borne by
the manufacturer. This was confirmed in writing
by the manufacturer through their letter #Nil dated
November 10, 2012.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter #Nil dated 25 November 2014.
Hyundai Electric & Energy Systems Co. Type / Model: Shunt Reactor PQ Letter:
Ltd TS&SD Letters # 10-02438-02-03032301 dated
SOUTH KOREA August 31,2010 and 13-05782-1-30504401,
December 11, 2013, pre-qualified for Shunt
Plant -Ulsan Reactor as conforming to National Grid SA
specification # 58-TMSS-01, Rev.0 with the
1000, Bangeojinsunhwan-doro, following condition.
Dong-gu, Ulsan, South Korea,
CONDITION:
Ulsan
WARRANTY:
Contact Person - Mr. D. H. Choi , Mr. Ten (10) years extended warranty/guarantee in
Jinweon Lee respect of defects due to design, manufacture,
Phone - +966-11-4644696, +82 31 installation & workmanship from the date of
8006 6836 Provisional Acceptance Certificate (PAC) of the
Contact Person Email ID - first turnkey project in case of contract award or
danny.choi@hyundai-electric.com , date of delivery in case of direct material supply
leejw@hyundai-electric.com order and subsequently reduced yearly in case
Website - of future project award. This was confirmed by
http://www.hyundai-elec.com HHI –Korea through letter #S370 -1008-0182
dated 18/08/2010.
MITSUBISHI ELECTRIC CORPORATION Type / Model: ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter #1/115-3552
dated December 14, 2011.
SIEMENS AG (NURNBERG)
GERMANY
Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx
Weiz , Austria
Website - http://www.vatechetg.at/
Website -
http://www.toshiba.co.jp/index j3.htm
Total = 14
REACTOR
27. 2
OIL IMMERSED REACTORS, (110 KV TO 132 KV ) Applicable Standards: 58-TMSS-01
ABB ( T& D)
United States
Website - http://www.abb.us/
Website - http://www.areva.com/
CONDITION:
All Type, Special & Routine tests as per latest
National Grid SA Standards & IEC requirements
[excluding Short circuit test ] shall be carried out
on the first unit to be supplied to SEC/National
Grid SA in the manufacturer Laboratory in the
presence of three (3) National Grid SA Engineers
& one (1) National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer
through their letter # Nil, dated November 10,
2012.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter #Nil dated 25
November 2014.
HITACHI LTD Rating - upto 380 kv Class Test Report No. - Originally JAPAN AE POWER SYSTEM CORP and
JAPAN will be submitted subsequent change affected as per HITACHI
after CN letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated
18-12-2012.
Akihabara Daibiru Building, 18-13,
Soto-Kanda 1-Chome, Chiyoda-Ku,
Tokyo, 101-8608, Japan
Hyundai Electric & Energy Systems Co. Type / Model: Shunt Reactor PQ Letter:
Ltd TS&SD Letters # 10-02438-02-03032301 dated
SOUTH KOREA Rating: 132kV August 31,2010 and 13-05782-1-30504401,
December 11, 2013, pre-qualified for Shunt
Plant -Ulsan Reactor.
MITSUBISHI ELECTRIC CORPORATION Type / Model: ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Rating: 132kV
Plant -T&D Systems Center, Amagasaki
City, Japan
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed in writing by the
manufacturer through their letter # 1/115-3552
dated December 14, 2011.
SIEMENS AG (NURNBERG)
GERMANY
Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx
Weiz , Austria
Website - http://www.vatechetg.at/
Website -
http://www.toshiba.co.jp/index j3.htm
Total = 14
REACTOR
27. 3
OIL IMMERSED REACTORS, (230 KV) Applicable Standards: 58-TMSS-01
ABB ( T& D)
United States
Website - http://www.abb.us/
Website - http://www.areva.com/
HITACHI LTD Rating - upto 380 kv Class Test Report No. - Originally JAPAN AE POWER SYSTEM CORP and
JAPAN will be submitted subsequent change affected as per HITACHI
after CN letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan FUJI letter # AT-LTR-121115-1, dated
18-12-2012.
Akihabara Daibiru Building, 18-13,
Soto-Kanda 1-Chome, Chiyoda-Ku,
Tokyo, 101-8608, Japan
Hyundai Electric & Energy Systems Co. Type / Model: Shunt Reactor PQ Letter:
Ltd TS&SD Letters # 10-02438-02-03032301 dated
SOUTH KOREA Rating: 230kV August 31,2010 and 13-05782-1-30504401,
December 11, 2013, pre-qualified for Shunt
Plant -Ulsan Reactor.
MITSUBISHI ELECTRIC CORPORATION Type / Model: ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN DURING APRIL 2005.
Rating: 230kV
Plant -T&D Systems Center, Amagasaki
City, Japan
SIEMENS AG (NURNBERG)
GERMANY
Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx
Weiz , Austria
Website - http://www.vatechetg.at/
Website -
http://www.toshiba.co.jp/index j3.htm
Total = 12
REACTOR
27. 4
OIL IMMERSED REACTORS, (380 KV ) Applicable Standards: 58-TMSS-01
Website - http://www.abb.us/
FUJI ELECTRIC CO. Type / Model: Oil Immersed Shunt Originally JAPAN AE POWER SYSTEM CORP and
JAPAN Reactors subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
Rating: FUJI letter # AT-LTR-121115-1, dated
18-12-2012.
GRID SOLUTIONS ENERJI ENDUSTRISI Type / Model: Oil Immersed Shunt Previously ALSTOM GRID, GEBZE
ANONIM SIRKETI Reactors
TURKEY PQ Letter:
Rating: 380 kV S&SD letter# 13-04034-2-30504401 dated
September 12, 2013, pre-qualified for 380 kV Oil
Immersed Shunt Reactors.
CONDITION:
All type/special, routine tests for 380 kV Oil
Immersed Shunt Reactors on one unit of each
rating supplied to SEC shall be conducted at
Manufacturer's Testing Laboratory in presence
of three (3) SEC/National Grid SA engineers &
one (1) SEC approved independent inspection
agency Inspector, all the related costs for
witnessing the tests will be borne by the
manufacturer. This was confirmed by Alstom
Grid, Turkey through their letter # Nil, dated July
22, 2013.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order as confirmed by Alstom Grid, Turkey
through their letter # Nil, dated July 22, 2013.
HITACHI LTD Type / Model: Oil Immersed Shunt Originally JAPAN AE POWER SYSTEM CORP and
JAPAN Reactors subsequent change affected as per HITACHI
letter # XAE-VR-121213, dated 13-12-2012 and
Plant -Tokyo, Japan Rating: FUJI letter # AT-LTR-121115-1, dated
18-12-2012.
Akihabara Daibiru Building, 18-13,
Soto-Kanda 1-Chome, Chiyoda-Ku,
Tokyo, 101-8608, Japan
HYOSUNG (HICO) Type / Model: Oil Immersed Shunt Type, Routine PQ Letter:
SOUTH KOREA Reactors &Special tests shall S&SD letter # 14-10289-02-30504401 dated 18
be conducted January 2015, the manufacturer is prequalified
Plant -Republic of Changwon, Korea Rating: 380kV for Oil Immersed Reactor up to 380 KV.
Hyundai Electric & Energy Systems Co. Type / Model: Oil Immersed Shunt PQ Letter:
Ltd Reactors TS&SD Letters # 10-02438-02-03032301 dated
SOUTH KOREA August 31,2010 and 13-05782-1-30504401,
Rating: 380kV December 11, 2013, pre-qualified for Shunt
Plant -Ulsan Reactor.
MITSUBISHI ELECTRIC CORPORATION Type / Model: Oil Immersed Shunt ORIGINALLY TMT&D CORP. & DISSOLVED
JAPAN Reactors DURING APRIL 2005.
SIEMENS AG (NURNBERG)
GERMANY
Website -
http://www.energy.siemens.com/cms/
us/US
Products/Portfolio/Transformers/Pages/
TransformerandLTCRenewalPartSolutio
ns.aspx
Weiz , Austria
Website - http://www.vatechetg.at/
Website -
http://www.toshiba.co.jp/index j3.htm
Total = 12
REACTOR
27. 5
AIR CORE SERIES REACTOR, 13.8KV THROUGH 380KV (230 KV AIR CORE Applicable Standards: 52-TMSS-02, 58-TMSS-02
NOKIAN – GRID SOLUTIONS OY LTD. Type / Model: Air core series reactor PQ Letter:
FINLAND S&SD letter # 14-03642-01-30504401 dated June
Rating; 145kV 11, 2014, NOKIAN – ALSTOM Grid oy Ltd.
Tampere , Finland Tampere-Finland is pre-qualified for Air Core
P.O.Box 4, Kaapelikatu 3 fl-33331 Series Reactors up to145 kV.
Vehmaistenkatu 5 fl-33730
WARRANTY:
Phone - +358 3 388311 Ten (10) years extended warranty/guarantee in
Email ID - firstname.surname@ge.com respect of defects due to design, manufacture,
Website - www.gegridsolutions.com installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer through
their letter # Nil, dated 20th June 2012.
POWER ECONOMY MIDDLE EAST CO. Type / Model: Air core Reactor. PQ Letter:
United Arab Emirates Based on TS&SD letter #07-F691-03032300
Rating: Limited to 34.5kV only dated May 21, 2007, it is pre-qualified for Air
Plant -Abu Dhabi , United Arab Emirates Core Reactors Limited to 34.5kV only
Website - WARRANTY:
http://www.powereconomy.net/ Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed through the manufacturer
letter # O-694-KSA-SEC, dated 20th Nov,2006.
WARRANTY:
Seven (7) years Extended Warranty shall be
applicable for the Air Core Series Reactors to be
supplied to SEC by TRENCH CANADA as
confirmed through their letter # NIL dated April 28,
2010.
Total = 4
CELLMEC
BAHRAIN
Website - http://www.cellmec.com/
Total = 1
ABB
SWITZERLAND
Total = 2
Website -
http://www.atlanticwood.com/
COLFAX CREOSOTING CO
United States
KOPPERS INDUSTRIES
United States
Pa , United States
Website - http://www.koppers.com/
STALLWORTH TIMBER
United States
Website -
http://www.stella-jones.com/welcome
eng.htm
Website -
http://www.taylorlumberinc.com/
Total = 7
Website -
http://www.atlanticwood.com/
COLFAX CREOSOTING CO
United States
KOPPERS INDUSTRIES
United States
Pa , United States
Website - http://www.koppers.com/
STALLWORTH TIMBER
United States
Website -
http://www.stella-jones.com/welcome
eng.htm
Website -
http://www.taylorlumberinc.com/
Total = 7
ABB ( T& D)
United States
Website - http://www.abb.us/
UNIBUS
United States
WESCOSA
Saudi Arabia
Website - http://www.wescosa.com/
Total = 3
SWITCHES
32. 1
LV AUTO-TRANSFER SWITCH Applicable Standards:
ALSTOM
FRANCE
Website -
http://www.alstom.com/home/
ASCO
United Arab Emirates
Website - http://www.asco.co.ae
WESTINGHOUSE
United States
Website -
http://www.westinghouse.com
Total = 3
SWITCHES
32. 2
PAD MOUNTED SF6/OIL SWITCH, 34.5 KV Applicable Standards:
FRITZ DRIESHER KG
GERMANY
Website -
http://www.driescher.de/home/index.ht
m
Total = 1
SWITCHES
32. 3
CIRCUIT SWITCHER, 69 –230 KV Applicable Standards:
S&C
United States
Website - http://www.sandc.com/
S&C
CANADA
SIEMENS
GERMANY
Berlin, Germany
IC SG EA MF
Wernerwerkdamm 5,
13629, Berlin, Germany
Total = 3
TRANSDUCERS
33. 1
FREQUENCY TRANSDUCERS Applicable Standards:
ALSTOM
United States
Website -
http://www.alstom.com/home
ISKRA MIS Adnan Sabban Type/Model - Saprk Energy DZ9 ACCEPTANCE SUBJECTED TO SUCCESSFUL
SLOVENIA Est Office #6 1st Floor Al PRODUCT EVALUATION / ACCEPTANCE BY SEC
Hamad II Center Al Zahra CONCERNED END USER DEPARTMENT FOR
Kranj , Slovenia District EACH PURCHASE ORDER / PROJECT DURING
050-55-989-84 ,Phone - TENDER/BIDDING STAGE.
050-55-989-84
zakaria@ase-ksa.com
Total = 2
TRANSDUCERS
33. 2
TAP POSITION TRANSDUCERS Applicable Standards:
AREVA
United Kingdom
Website - http://www.areva.com/
Total = 1
TRANSDUCERS
33. 3
TRANSDUCERS Applicable Standards:
CEWE INSTRUMENTS AB
SWEDEN
Website -
http://www.ceweinstrument.se/
ENERDIS
FRANCE
Website -
http://www.chauvin-arnoux.com/
LSIS , WARRANTY
SOUTH KOREA Seven (07) years extended warranty/guarantee
in respect of defects due to design, manufacture,
Ls Tower, 127, Ls-Ro, Dongan-Gu, installation & workmanship from the date of
Anyang-Si, Gyeonggi-Do, Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
Contact Person - Mr. Je-woo, Lee date of delivery in case of direct material supply
Assistant Manager order.
Phone - +82-2-2034-4541
Email ID - jwleea@lsis.com
Website - http://www.lsis.com
TILLQUIST
SWEDEN
Website - http://www.tillquist.com/
WARRANTY
Five (05) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order. This was confirmed by TYCO Electronic,
UK through their letter # INT-SEC-06 dated
Jamuary 03, 2008 and its amendment dated
November 21, 2011
Total = 5
TRANSDUCERS
33. 4
WATTHOURS/VARHOURS TRANSDUCERS Applicable Standards:
ISKRA MIS Adnan Sabban Type/Model - Sparklight , ADM 16 ACCEPTANCE SUBJECTED TO SUCCESSFUL
SLOVENIA Est Office #6 1st Floor Al PRODUCT EVALUATION / ACCEPTANCE BY SEC
Hamad II Center Al Zahra CONCERNED END USER DEPARTMENT FOR
Kranj , Slovenia District EACH PURCHASE ORDER / PROJECT DURING
Phone - 050-55-989-84 TENDER/BIDDING STAGE.
Email -
zakaria@ase-ksa.com
MITSUBISHI ELECTRIC
JAPAN
Website -
http://global.mitsubishielectric.com/
SCIENTIFIC COLUMBUS
United States
Website -
http://www.scientificcolumbus.com/
Total = 3
TRANSDUCERS
33. 5
VOLTAGE TRANSDUCERS Applicable Standards:
Montreal , Canada
Website - http://www.abb.ca/
AREVA
United Kingdom
Website - http://www.areva.com/
TRANSDATA
United States
Website -
http://www.transdatainc.com/index.ht
m
Total = 4
TRANSDUCERS
33. 6
WATTS/VARS TRANSDUCERS Applicable Standards:
Montreal , Canada
Website - http://www.abb.ca/
AREVA
United Kingdom
Website - http://www.areva.com/
TRANSDATA
United States
Website -
http://www.transdatainc.com/index.ht
m
Total = 4
ABB AUTOMATION CO. LTD. ,SAUDI ABB Automation Co. Ltd Old remarks:
ARABIA Riyadh PQ Lettter
Saudi Arabia Phone - 0504417681 Based on S&SD letter# 14-00953-1-30504401
Email - dated February 27, 2014, ABB Automation Co.
Plant -2Nd Industrial Area,Riyadh, Aref.alarrak@sa.abb.co Ltd., Riyadh is pre-qualified for integration and
m testing of SAS systems for substations rated up
Po Box 325841 Riyadh,11371 KSA to 230kV against specification # TES-P-107.01,
Rev.00 with the following conditions:
Contact Person - Mr. Aref Alarrak
Phone - +966-504417681 CONDITION
Email ID - Aref.alarrak@sa.abb.com Type test shall be conducted in independent
testing laboratory for the SAS System as per
National Grid SA Specifications/Standards,
IEC61850 Edition2, and latest amendments of IEC
in an accredited laboratory in presence of three
(03) SEC/National Grid SA engineers and one
(01) National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer by
ABB-Riyadh through their letter #
PSN/SAS/0709/08/2013 dated July 09, 2013.
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
CONDITION
Type test shall be conducted in independent
testing laboratory for the SAS System as per
National Grid SA Specifications/Standards,
IEC61850 Edition2, and latest amendments of IEC
in an accredited laboratory in presence of three
(03) SEC/National Grid SA engineers and one
(01) National Grid SA approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer by
ALSTOM Grid AG –France, U.K through their
letter SAS/TSSD/2014/WR1201-1 dated January
12, 2014.
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order.
30 DO + 8 AI}
( 8 Analog Current Inputs selectable 4-20 mA, 0-1
mA, 0-5 mA, 0-10 mA, 0-20 mA )
SAS Equipment:
CONDITION
Type Tests: The manufacturer has confirmed to
perform the required type tests in Independent
Testing laboratories- KEMA as per SEC/National
Grid SA requirements, IEC 61850 Edition 2
standards in the presence of three (3)
SEC/National Grid SA Engineers and one (1)
Independent Inspector through reference letter #
SEL/SAS/08/2013.
WARRANTY
The manufacturer has agreed to give guarantee/
warranty to SEC/National Grid SA for the
proposed Substation Automation System (SAS)
from SEL U.S.A with Integration & Testing facility
at SEP –Riyadh K.S.A in respect of the defects
due to design, manufacturing, installation and
workmanship for a period of ten (10) years , This
was confirmed in writing by the manufacturer
through their letter ref: nil dated February 18,
2013.
WARRANTY:
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of PAC
of the first turnkey project (in case of contract
award) or from the date of first delivery in case
of direct material supply order as confirmed from
SIEMENS -Germany & for Integration & Testing
facility at SIEMENS –Jeddah K.S.A the
Siemens-Germany & Siemens –Jeddah K.S.A
through their letter # Nil dated November 12,
2012.
Manufacturers.
SPRECHER AUTOMATION GMBH ALFANAR ELECTRICAL up to 380KV Based on the S & SD fax #
AUSTRIA SYSTEMS Saudi Arabia 16-08451-02-30504401 dated 16/11/2016
Plant -3Rd Industrial Sprecher Automation GmbH –Austria with
Plant -Franckstrabe 51,4018 Linz, Zell Area, Al Integration and FAT at Al-Fanar Electrical System
am See & Vienna in Austria Kharaj Road, Riyadh –Riyadh K.S.A for Substation Automation
Saudi Arabia System- SAS up to 380KV is prequalified against
Contact Person - Mr. Peter Wach –Area Po Box 301 , Riyadh TES-P-107.01, Rev.00, with the following
Sales Manager 11411 , North conditions:
Contact Person Email ID - Righ Road Between Exit
peter.wach@sprecher-automation.com 5&6 1. Type Tests: The manufacturer has confirmed
Riyadh , Saudi Arabia to perform the required type tests in SEC/National
Contact Person - Mr. Grid SA approved Independent Testing laboratory
Samer Y. Mokdad , as per SEC/National Grid SA requirements , IEC
Executive Manager. 61850 Edition 2 standards in the presence of
Email: three (3) SEC/National Grid SA Engineers and
samer.mokdad@alfanar. one (1) Independent Inspector through reference
com letter dated 24/10/2016 , ref#
ashraf.mohamed@alfan AES-SAS-PQA-2016/008.
ar.com
Phone - 2. Guarantee/Warranty: The manufacturer (Both
+966-540339574 Sprecher & Al-Fanar) has agreed to give
guarantee/ warranty to SEC/National Grid SA for
the proposed Substation Automation System
(SAS) from SPRECHER Automation GmbH
-Austria with Integration and FAT at AL-FANAR
ELECTRICAL SYSTEM –Riyadh K.S.A in respect
of the defects due to design, manufacturing,
installation and workmanship for a period of ten
(10) years , This was confirmed in writing by the
manufacturer through their letter for SAS.
Edition.
Total = 7
NEST OY/NAPS
FINLAND
Total = 1
ATOFINA CHEMICALS
United States
Website - http://www.atofina.com
Website -
http://www.dielectrictechnologies.com/
index.html
Website - http://
http://www.furukawa.co.jp/english/ind
ex.
INDOPOL
FRANCE
Lavera , France
Website - http://www.indopol.com/
SIEMENS
GERMANY
Total = 5
DC POWER SYSTEMS
37. 1
DC POWER SYSTEMS Applicable Standards:
EXIDE CORP.
United States
Pa , United States
Website - http://www.exide.com/
Website -
http://www.harmerandsimmons.com/
Website -
http://www.powersupplysystems.com/
index2.htm
Total = 4
Turgi , France
Website - http://www.abb.fr/
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
AREVA
FRANCE
Website - http://www.ge.com/
NERA
NORWAY
SIEMENS
GERMANY
Berlin, Germany
IC SG EA MF
Wernerwerkdamm 5,
13629, Berlin, Germany
Total = 6
POSITRON INDUSTRIES
CANADA
Montreal,Canada
Total = 1
VF INTERFACE EQPT.
40. 1
VF INTERFACE EQPT. Applicable Standards:
Turgi , Switzerland
Website - http://www.abb.ch/
TELLABS INC.
United States
Website - http://www.tellabs.com/
Total = 2
ELECTRONIA
Saudi Arabia
Website - http://www.electronia.com/
GE/ERICSON
United States
GLENAYRE
CANADA
Bc , Canada
Website - http://www.glenayre.com
KENWOOD
United States
Website -
http://www.kenwoodusa.com/
MOTOROLA
United States
Website -
http://www.motorola.com/us/products.j
sp
NEC
United States
Website - http://www.nec.com/
NOKIA
FINLAND
Website - http://www.nokia.com/
PHILIPS
United Kingdom
Website -
http://www.philips.co.uk/index.page
Total = 8
TEST EQUIPMENT
42. 1
TEST EQUIPMENT Applicable Standards:
ACTERNA
United States
Website - http://www.acterna.com/
Tokyo , Japan
Website - http://www.ando.nl/
Website - http://www.hp.com/
IFR
United States
PHILIPS
United Kingdom
Website -
http://www.philips.co.uk/index.page
Website -
http://www2.rohde-schwarz.com/
TREND
SPAIN
Website -
http://es.trendmicro.com/es/home/
Total = 8
TEST EQUIPMENT
42. 2
TEST EQUIPMENT (FIBER OPTIC RELATED) Applicable Standards: 48-TMSS-14
ANRITSU CORPORATION
JAPAN
Tokyo , Japan
Website - http://www.anritsu.com/
Total = 1
TEST EQUIPMENT
42. 3
TEST EQUIPMENT (RADIO RELATED) Applicable Standards:
BIRD
United States
Website -
http://www.bird-electronic.com/
MARCONI
United Kingdom
Website -
http://mecss.com.sa/contact.html
Total = 2
TEST EQUIPMENT
42. 4
TEST EQUIPMENT (RADIO/PAGING RELATED) Applicable Standards:
NEC
United States
Website - http://www.nec.com/
Total = 1
TEST EQUIPMENT
42. 5
RADIO/PAGING EQUIPMENT (ACCESSORIES) Applicable Standards:
ALLEN
United States
ANDREW
United States
Il , United States
Website - http://www.andrew.com/
CELWAVE
United States
Website - http://www.celwave.com/
DECIBEL
United States
FLEXWELL
United States
JAYBEAM
United Kingdom
Website -
http://www.jaybeamwireless.com/inde
x.php
Website - http://uk.rs-online.com/web/
Total = 8
UHF RADIO
43. 1
UHF RADIO Applicable Standards:
ALCATEL
FRANCE
Website - http://www.alcatel.fr/
ASCOM
United Kingdom
Website -
http://www.ascom.co.uk/uk-en
SIMOCO
United Kingdom
Website -
http://www.simoco.com/index.php
Total = 3
ABB-Ludvika
SWEDEN
Plant -Sweden
Ludvika, Sweden
NOKIA
FINLAND
Website - http://www.nokia.com/
NORTEL
CANADA
Website - http://www.nortel.com/
Total = 3
Website -
http://www.atd-cardox.com/atd-cardo
x-vertretungen.htm
Website -
http://www.chemetron.com/utcfs/Temp
lates/Pages/Template-46/1,8060,pageId
=1192&siteId=374,00.html
FIKE
United States
Website - http://www.fike.com/
HYGOOD
United States
Website -
http://www.hygood.co.uk/default.asp
JANUS FIRE SYSTEMS Mr. John Parker CO2 UL Listed The manufacturer is added based on
United States + 9733888644 Low pressure & High Pressure confirmation by Industrial Security Sector
john.parker@amerex-fire Systems /Industrial Security Performance Department
1102 Rupccih Drive .com Manager as per email message of
Millennium Park January,16,2017”.
Crown point ,IN 46307
“ Janus Fire Systems, USA, has agreed to give
Telephone :219.663.1600 Guarantee/ Warranty to SEC/ National Grid SA
Fax : 219.663.4562 vide letter # Nil, dated April 07, 2017, for the
proposed Fire Fighting System-High Pressure
Contact Person - Barry Cornel Carbon Dioxide (CO2) in respect of the defects
Email ID - due to design and manufacturing for a period of
bcornell@janusfiresystems.com ten (10) years from the date of the Provisional
Acceptance Certificate (PAC) of the project (in
case of contract award) or from date of delivery
for the direct material supply order. The
guarantee/ warrant shall be applicable for the
first project and shall subsequently be reduced
yearly in case of future project award
Website - http://www.kiddeus.com/
NAFFCO NAFFCO UL listed Co2 extinguisheres ,model UL listed The manufacturer is added based on
United Arab Emirates PO BOX 67716 RIYADH 451,456,466, C -50-SE ,and C-100-SE. LPCB approved UL confirmation by Industrial Security Sector
11517 UL listed Dry Chemical Extinguishers listed Fire /Industrial Security Performance Department
NAFFCO, P.O Box :17014, Dubai, TEL : 0112824444 Wheeled type. Extinguishers ,and Manager as per email message of
United Arab Emirates. 'Sathiskumar@naffco.co LPCB Mobile Fire Extingishres. LPCB/BSI approved January,16,2017”, and April 24, 2017
m'; Fire Extinguishers
Tel :- # 97148066666 'ksa.est1@naffco.com'
Fax: # 971 48816229
Dubai
Total = 7
GRINNEL
United States
Website - http://www.grinnell.com/
Website -
http://www.reliablesprinkler.com/
SPRAYSAFE
United States
Website -
http://www.centralspraysafe.com/cgi-
bin/webscripts/nph-home.pl
Website -
http://www.vikingrange.com/consumer
/index.jsp
WATTS
United States
Website - http://www.watts.com/
Total = 5
Fike Corporation NAFFCO Fike UL /FM approved FM 200 UL Listed FM The manufacturer is added based on
United Arab Emirates PO BOX 67716 RIYADH Using Fike impulse Valve with burst approved confirmation by Industrial Security
11517 disc Sec-or/Industrial Security Performance
Plant -Dubai Gulf Star Security & Department Manager per email mess-age of
Safety Jan-uary,16,2017”, and April 24, 2017.
Sheikh Zayed Road P.O Box 125917 Head office ,2nd floor ,Al
kaaf Al Akhdr Bldb,
Steen street , Jeddah
Al-Sarh Al-Methali
Trading
6th street ,off 95th
street. 2nd industrial City
Dammam
TEL : 0112824444
FIRETRACE Guarantee Business FM200 System: UL & ULC listed The manufacturer is added based on
United States Contracting Est Models,01-001372,01-001407, confirmation by Industrial Security Sector
KSA – P.O Box 26018 01-001487,01001587,01-001712,01-00 /Industrial Security Performance Department
USA L L C EX15893 Riyadh 1897,01-002537 all @360 psig (25 bar) Manager as per email message of
SUITE 2 0114919669 January,16,2017”.
8435 N 90TH ST
SCOTTSDALE, AZ 85258 USA
Middle East, North Africa & Caspian
GREAT LAKES
United States
JANUS FIRE SYSTEMS Mr. John Parker, FM200 System: UL Listed The manufacturer is added based on
United States Ph: + 9733888644 Sv, Mv and Lv Series. confirmation by Industrial Security Sector
john.parker@amerex-fire /Industrial Security Performance Department
1102 Rupccih Drive .com Manager as per email message of
Millennium Park January,16,2017”.
Crown point ,IN 46307 “Janus Fire Systems, USA, has agreed to give
Guarantee/ Warranty to SEC/National Grid SA
Telephone :219.663.1600 vide letter # Nil, dated April 07, 2017, for the
Fax : 219.663.4562 proposed Fire Fighting Systems -FM- 200
(HFC-227ea Heptalour-propane CF3CHFCF3) in
Contact Person - Barry Cornel respect of the defects due to design and
Email ID - manufacturing for a period of ten (10) years from
bcornell@janusfiresystems.com the date of the Provisional Acceptance Certificate
(PAC) of the project (in case of contract award)
or from date of delivery for the direct material
supply order. The guara-tee/warrant shall be
applicable for the first project and shall
subsequ-ntly be reduced yearly in case of future
project award.
SIEMENS BUILDING TECHNOLOGIES – Siemens Ltd. Sinorix 227 (360 PSI) Fire Extinguishing UL Listed The manufacturer is added based on
FIRE SAFETY Business Gate, P.O. Box System. confirmation by Industrial Security Sector
United States 9510, 11423 Riyadh, •The gas is identified as:UL scope of fil /Industrial Security Performance Department
Saudi Arabia EX6288, SHANGHAI Waysmos Fine Manager as per email message of
SIEMENS INDUSTRY INC EX4724 Chemical Co Ltd (DBA Waysmos USA, January,16,2017”.
8 Fernwood Rd Tel +966 (11) 277 8208, Product tradename MH227),388 Liangle
Fax +966 (11) 277 8497, Rd, Laogang Town Pudong New
Florham Park, NJ 07932-1906 USA Mobile +966 (54) 335 District 201322 Shanghai, CHINA
0691, +966 (54) 346
3238
ashfaq.abdul-jabbar@si
emens.com
SIEX Engineering Field Est. 1) SIEX –HC 227 (25 & 24 bar). UL Listed FM The manufacturer is added based on
SPAIN Phone : 02-6579028 2) SIEX –HC227 S- Flow (32.34.50.& approved. confirmation by Industrial Security Sector
Fax : 026579028 55 bar) /Industrial Security Performance Department
2001 SL Agil Alattas Manager as per email message of
POL INDUSTRIAL VILLAONQUEJAR info@ef.com.sa January,16,2017
C/MERINDAD DE MONTIJA NO 6
09001 BURGOS,SPAIN
Viking GmbH & Co. KG Advanced Elements for FM200 System: UL/FM/VdS The manufacturer is added based on
GERMANY Fire Protection Systems Model VSN200 @ 25, 42& 50 bars UL/FM/VdS confirmation by Industrial Security Sector
Tel: 0114722799 /Industrial Security Performance Department
INDUSTRIESTRASSE 10/12 Manager as per email message of
23480 BAD OLDESLOE, GERMANY January,16,2017
Total = 8
Website - https://
http://www.ansul.com/en/home.asp
Website -
http://www.chemetron.com/utcfs/Temp
lates/Pages/Template-46/1,8060,pageId
=1192&siteId=374,00.html
FENWAL
United States
FIGGIE
United States
FIKE
United States
Website - http://www.fike.com/
FIREATER
United States
HYGOOD
United States
Website -
http://www.hygood.co.uk/default.asp
KIDDE
United States
Website - http://www.kiddeus.com/
MINIMAX PQ Lettter
GERMANY Based on S&SD Letter 12-02704-02-30504001
dated February 19, 2012. It is pre-qualified for
Bad Oldesloe , Germany Fire Protective Signaling Panel as conforming to
SEC Specification # 90-TMSS-01 Rev.0
CONDITION
All Type, Routine and Special testes shall be
carried out on the first batch of Fire Protective
Signaling Panel in an Independent Testing
Laboratory in the presence of three (3) SEC
Engineers & one (1) SEC approved Independent
Inspection Agency (IIA) Inspector. All costs of
which shall be borne by the manufacturer. This
was confirmed in writing by the manufacturer
through their letter # Nil dated January 11, 2011.
WARRANTY
Ten (10) years extended warranty/guarantee in
respect of defects due to design, manufacture,
installation & workmanship from the date of
Provisional Acceptance Certificate (PAC) of the
first turnkey project in case of contract award or
date of delivery in case of direct material supply
order, as confirmed by the manufacturer thru
letter #nil, dt: jan 11, 2011.
Total = 10
FIRETRACE Guarantee Business Novec1230 System: UL & ULC listed The manufacturer is added based on
United States Contracting Est Models : 01-001352, confirmation by Industrial Security Sector
KSA – 01-001366,01-001399, /Industrial Security Performance Department
USA L L C EX15893 P.O Box 26018 01-001440,01-001490, Manager as per email message of
SUITE 2 Riyadh 01-001564,01-001705,01- January,16,2017”.
0114919669 0011827 all @34 bar
8435 N 90TH ST
SCOTTSDALE, AZ 85258 USA
Middle East, North Africa & Caspian
JANUS FIRE SYSTEMS Mr. John Parker Novec1230 System: UL Listed “The manufacturer is added based on
United States Ph: + 9733888644 Sv, Mv and Lv Series confirmation by Industrial Security Sector
E Mail: /Industrial Security Performance Department
1102 Rupccih Drive john.parker@amerex-fire Manager as per email message of
Millennium Park .com January,16,2017”.
Crown point ,IN 46307 Janus Fire Systems, USA, has agreed to give
Guarantee/Warranty to SEC/National Grid SA vide
Telephone :219.663.1600 letter # Nil, dated April 07, 2017, for the proposed
Fax : 219.663.4562 Fire Fighting Systems-Novec 1230 Fluid
(F-K-1-12 Dodecafluoru-2-methylpentan-3-one
Contact Person - Barry Cornel CF2CF2C(O)CF(CF3)2) in respect of the defects
Email ID - due to design and manufacturing for a period of
bcornell@janusfiresystems.com ten (10) years from the date of the Provisional
Acceptance Certificate (PAC) of the project (in
case of contract award) or from date of delivery
for the direct material supply order. The
guarantee/warrant shall be applicable for the first
project and shall subsequently be reduced yearly
in case of future project award.
SFFECO 3M Novec 1230 Fire protection UL Listed FM The manufacturer is added based on
Saudi Arabia Extinguishing system units having approved. confirmation by Industrial Security Sector
nominal ging capacitiec of Multiple Listing with /Industrial Security Performance Department
2ND INDUSTRIAL AREA 38,65,,130,2277,and 895 lb @ 25 bar. SEVO Manager as per email message of
AL-KHARJ RD Design & installation per Sevo VDS January,16,2017”.
PO BOX 58469 software Novec –Calculationprogram.
RIYADH, 11515 SAUDI ARABIA
Viking GmbH & Co. KG Advanced Elements for Novec1230 System: UL/FM/VdS The manufacturer is added based on
GERMANY Fire Protection Systems Model VSN1230 @25, 42 &50 bars. UL/FM/VdS confirmation by Industrial Security Sector
Tel: 0114722799 /Industrial Security Performance Department
INDUSTRIESTRASSE 10/12 Manager as per email message of
23480 BAD OLDESLOE, GERMANY January,16,2017”.
Total = 4
AUTOCALL (GRINNEL)
United States
Hochiki America Corporation Engineering Field Est. Addresable (Fire net seies ) & UL Listed FM The manufacturer is added based on
United States Agil Alattas Conventional (HCA seies)Fire Alarm & approved. confirmation by Industrial Security Sector
Phone : 02-6579028 Detection Systems :- /Industrial Security Performance Department
7051 Village Drive, Suite 100 Buena Fax : 026579028 • Fire Control Panels. Manager as per email message of
Park, CA 90621-2268 info@ef.com.sa • Gas Extinguishing Control Panels. January,16,2017”.
• Fire Detection & Alarm Devices.
Phone - Phone : 714/522-2246
Email ID -
technicalsupport@hochiki.com
Website - WWW.Hochiki.com
MIRETONE
United States
SHIELD FIRE SAFETY & SECURITY LTD NAFFCO Extinguishing Control panel mpdel A-Xt. UL Listed FM The manufacturer is added based on
United Kingdom PO BOX 67716 RIYADH Poto –Electric smoke detector model S approved. confirmation by Industrial Security Sector
11517 C2011 /Ind-ustrial Sec-urity Perform-ance Depart-ment
SHIELD FIRE SAFETY & SECURITY LTD TEL : 0112824444 Heat Detector S-C2013 Standard Mana-ger as per email mess-age of
S25191 Eng Selva. mounting base S-c2001Abort switich Jan-uary,16,2017”
REDBURN HOUSE S111R AB
2A TONBRIDGE ROAD Fire Alarm Bell FB-1000C6
ROMFORD, ESSEX RM3 8QE UNITED
KINGDOM
Website -
http://www.simplexgrinnell.com/
THORN
United Kingdom
Website -
http://www.thornlighting.co.uk/gb/en/in
dex.htm
Total = 9
Website - http://www.aurora.com/
FAIRBANK MORSE
United States LOCAL AGENT –SAUDI PUMP >=500GPM
Website -
http://www.fairbanksmorse.com/
FLOWAY
United States
Website -
http://www.weiroilandgas.com/weirw
eb/oilandgas/home.nsf
ITT
United States
Website - http://www.itt.com/
Website -
http://www.peerlesspump.com/
PETTERSON
United States
Website -
http://www.ie.pattersonpumps.com/
REDDY BUFFALOU
United States
Website - http://www.rbpump.com/
Website -
http://www.worthington-biochem.com/
Plant -.
Total = 9
SFFECO
Saudi Arabia
Total = 2
Website - https://
http://www.ansul.com/en/home.asp
Website - http://www.kiddeus.com/
Website -
http://www.sentry-equip.com/display/r
outer.aspx
Total = 3
Website - https://
http://www.ansul.com/en/home.asp
Website -
http://www.sentry-equip.com/display/r
outer.aspx
Total = 2
Website -
http://www.sentry-equip.com/display/r
outer.aspx
Total = 1
ANGUS
United Kingdom
Website -
http://www.angusfire.co.uk/utcfs/Tem
plates/Pages/Template-46/0,8060,pageI
d%3D1260%26siteId%3D404,00.html
Website - http://www.chemguard.com/
HILTI INTERNATIONAL, Hilti construction Hilti Saudi Arabia P.O FIRESTOP PRODUCTS; UL Listed FM The manufacturer is added based on
chemicals ,Div.of Hilti Inc. box 286701 Firestop Sealants, firestop Foams, approved. confirmation by Industrial Security Sector
United States Riyadh11323 Firestop collars & Wraps ,Firestop /Industrial Security Performance Department
T: 0114608974 Mortars & Boards, Firestop cast in Manager as per email message of
5400 122nd East Ave Fax: 0114606255 Devices ,Firestop Blocks ,Plugs January,16,2017”.
Tusla ,OK 74146 Mobile : 0504657548 ,Cushions. Fire Protection Coatings &
abusheikha@ hilti.com Fire stop Transit Systems.
WWW.hilti.sa
Website -
http://www.kidde-fire.com/utcfs/Templ
ates/Pages/Template-50/0,8061,pageId
%3D3513%26siteId%3D465,00.html
Total = 4
HVAC Units
47. 1
HVAC Units Applicable Standards: 73-TMSS-01
PETRA
JORDAN
TRANE
Saudi Arabia
Total = 7
Total = 4
Total = 2
Saudi Arabia
SIEMENS
GERMANY
Berlin, Germany
IC SG EA MF
Wernerwerkdamm 5,
13629, Berlin, Germany
WESCOSA
Saudi Arabia
Website - http://www.wescosa.com/
Total = 3
Geneva, Switzerland
CG POWER SYSTEMS
BELGIUM
Website - http://www.pauwels.com/
Total = 2
ABB ( T& D)
United States
Website - http://www.abb.us/