PROJECT UBI ETHANOL PLANT PROJECT (SITE DEVELOPMENT & MAIN PROCESS BUILDING) BILL OF QUANTITY

UNIT PRICE (SR) TOTAL


ITEM DESCRIPTION UNIT QNTY.
IN FIGURES IN WORDS AMOUNT (SR)
FIREFIGHTING SYSTEM
Supplying, installing, connecting, testing and commissioning of fire protection
systems and fittings required for the complete assembly as specified and as
shown on drawings, as follows:

Fire hose steel cabinet single door, consisting of 40 mm brass valve, fire hose
1 reel, fire hose 40mm Dia. and 30 m long with all adapters and fittings required Nos. 19
for the complete assembly as specified and as shown on drawings.

2 Portable Dry Powder type ABC Fire Extinguisher 6 KG. Nos. 87

15 mm decorative upright type 68 °C, chrome plated sprinkler heads. K- Nos. 303
3
FACTOR 5.6

15 mm decorative pendent type 68 °C, chrome plated sprinkler heads. K- Nos. 57


4
FACTOR 5.6

5 PIPING AND FITTINGS

Supplying, Installing, Connecting and Testing of seamless grooved black carbon


steel fire pprotecting piping for all schedule 40 above ground pipes including,
pipes, fittings, required grooved couplings and adapters as specified below:-
BASED ON THE SHOP DRAWINGS, CONTRACTOR WILL CALCULATE THESE
QUANTITIES

25mm pipe diameter. LS 1

32mm pipe diameter. LS 1


5.1
40mm pipe diameter. LS 1

1 of 4
5.1

50mm pipe diameter. LS 1

65mm pipe diameter. LS 1

75mm pipe diameter. LS 1

100mm pipe diameter. LS 1

150mm pipe diameter. LS 1

Supplying, Installing, Connecting and Testing of High Density Polyethlyne


5.2 (HDPE) fire pprotecting piping for 150mm pipe diameter shceule 40 Under LS 1
ground pipes including pipes, fittings, required couplings and adapters.

Alarm Check Valve assembly + OS&Y - main alarm check valve completes with
6 alarm gang, pressure gauge, pressure switch, retard chamber and all Nos. 3
accessories as specification 150 mm.

Fire Department Connection 150 mm c/w non-return valve and 4 way / water
7 inlet every one 65 mm as specified and shown on the drawings as well as Nos. 3
supervising Engineer instructions.
8 FIRE PUMP UNIT

a- UL/FM APPROVED horizontal split case electric fire pump unit,


(2,000gpm) @ (10) bar. complete with electric motor, fire pump controller,
base plate, electric connections, pressure gauges, valves and all necessaries
for complete installations as specified and shown on the drawings as well as
supervising Engineer instructions.

b- UL/FM APPROVED horizontal split case DIESEL fire pump unit, set 1
(2,000gpm) @ (10) bar. complete with DIESEL engine, fire pump controller,
base plate, pressure gauges, valves and all necessaries for complete
installations as specified and shown on the drawings as well as supervising
Engineer instructions.

2 of 4
c- Vertical multi-stage centrifugal Jockey fire pump, (50gpm) @ (10.7) bar,
complete with electric motor, jockey pump controller, base plate, electric
connections, pressure gauges, valves and all necessaries for complete
installations as specified and shown on the drawings as well as supervising
Engineer instructions.

Supply and Install Wet Private Fire Hydrant, Size 4" Dia With1 No. 4" NST,
9 Pumper Connection and 2Nos 2.5" House Outlets with (OS&Y) gate valve, Nos. 4
SASO Approved, incompliance with NFPA 24.

Automatic Air Vent, ½", Cast iron body and cover, S/S inner parts and Non- Nos.
10
asbestos gasket. 3

Supply and install Post indicator, NRS/Gate valve 150 # internally and
11 externally epoxy coated, 150mm dia. (6in. dia.) with telescopic valve box for Nos. 4
U/G HDPE.

12 Zone control valve Assembly - 100 mm Nos. 9


Supplying, installing, connecting, testing and commissioning of automatic fire
13 suppression systems clean agent and fittings required for the complete Nos. 5
assembly as specified and as shown on drawings.

Supplying, installing, connecting, testing and commissioning of fire water


14 spray systems and fittings required for the complete assembly as specified and Nos. 1
as shown on drawings at ground floor.

Supplying, installing, connecting, testing and commissioning of wet water


and foam fire protection systems, fittings, foam sprinkler head, foam bladder Nos.
15
tank, foam concentrate pipe, foam solution pipe & foam proportional 1
required for the complete assembly as specified and as shown on drawings.

NON-ASPIRATED PENDENT FOAM WATER SPRINKLER (K-FACTOR = 5.6 / 7.0


15.1
psi) 3/4'' NPT - STANDARD RESPONSE - (121°) HIGH TEMPERATURE RATING Nos. 62

15.2 Foam bladder tank - alcohol resistance foam - 500 Gallon Nos. 1

16 Standpipe system class I, landing valves 65 mm Nos. 8

3 of 4
17 Portable CO2 type ABC Fire Extinguisher 6 KG. Nos. 21

FOAM WATER CABINET-synthetic jacket Hose size 1.5 inch x 30 meter length,
18 2" Foam proportioner or inductor, Foam branch pipe with shut off control Nos. 1
valve. Two canisters of 20 liter 3% foam concentrate, 1.5" Angle Valve.