SIMATIC ndc119\ 05/14/2024 12:58:50 AM

SIMATIC 300(1)\CPU 315-2 DP\...\FC10 - <offline>

FC10 - <offline>
""
Name: MP1 Family: ASSIGN
Author: Version: 0.0
Block version: 2
Time stamp Code: 08/06/2007 03:05:14 PM
Interface: 06/15/1998 04:16:00 PM
Lengths (block/logic/data): 00390 00280 00012

Name Data Type Address Comment


IN 0.0
OUT 0.0
IN_OUT 0.0
TEMP 0.0
RETURN 0.0
RET_VAL 0.0

Block: FC10

SAEEDSHAKIBI

Network: 1

M18.3
"ASSEGMENT Q10.0
I5.2 PROGRAM "BLOWER
"MP1 ON" SHODEH" MP1 ON"

Network: 2

I8.5 M10.0
I5.2 T1 "MP1 "MP1&BLOWE
"MP1 ON" S_ODT BLOWER OK" R OK"
S Q

S5T#1S500M
S TV BI
I5.2
"MP1 ON" BCD
R

Page 1 of 3
SIMATIC ndc119\ 05/14/2024 12:58:50 AM
SIMATIC 300(1)\CPU 315-2 DP\...\FC10 - <offline>

Network: 3

M17.1 M10.0 Q2.0


"DRILLING I5.2 I2.0 "MP1&BLOWE "PC15
2 CLOCK" "MP1 ON" "SC1 ON" R OK" M19.2 M13.0 SCR1(2)"

M17.2 I5.3
"DRILLING "MP1 TH
3 CLOCK" M12.0 MICRO SW" MOVE
EN ENO
M17.4 MW840
"DRILLING5 "MW840" IN OUT MW1708
CLOCK"
M12.0 MOVE
EN ENO
M18.0
"TRIPCLOCK I5.3 0 IN OUT MW1708
10 M" "MP1 TH
MICRO SW"

M18.1
"TRIP
CLOCK11 M"

Network: 4

M17.0 M10.0 Q2.3


"DRILLING I5.2 I2.1 "MP1&BLOWE "PC16
1 CLOCK" "MP1 ON" "SCR2 ON" R OK" M19.2 M13.0 SCR2"

M17.3 I5.3
"DRILLING "MP1 TH
4 CLOCK" M12.0 MICRO SW" MOVE
EN ENO
M17.7 MW840
"TRIP "MW840" IN OUT MW1710
CLOCK9 M"
M12.0 MOVE
EN ENO
I5.3 0 IN OUT MW1710
"MP1 TH
MICRO SW"

Page 2 of 3
SIMATIC ndc119\ 05/14/2024 12:58:50 AM
SIMATIC 300(1)\CPU 315-2 DP\...\FC10 - <offline>

Network: 5

I8.5
I5.2 T2 "MP1
"MP1 ON" S_ODT BLOWER OK" M13.0
S Q

S5T#4S TV BI
I5.2
"MP1 ON" BCD
R

Network: 6

FC20
"FC20"
EN ENO

MW4
"MW4" IN0

2000 IN1

L#10000 IN2

L#0 IN3

PIW256
"PIW256
MP1" IN4

MW840
"MW840" IO5

Page 3 of 3