REPUBLIC OF THE PHILIPPINES

DEPARTMENT OF ENGINEERING
LOT 1889 - B
OFFICE OF THE BUILDING OFFICIAL
OROQUIETA CITY, MISAMIS OCCIDENTAL
LINE BEARING DISTANCE
1-2 N 77° 20' E 19.70 MTS. APPROVED BY:
2-3 S 15° 31' E 26.14 MTS.
3-4 S 15° 31' E 3.00 MTS.
4-5 S 77° 06' W 16.03 MTS. FERNAN V. MARCHIAL

5-6 N 22° 32' W 3.00 MTS. City Engineer DATE


RECOMMENDING APPROVAL:
S 15° 31' E

P.S.
46.66m.
S 15° 31' E
3 3.00m. 4
26.14m.
17.52m. 2 S 15° 31' E
S 15° 31' E

LEGAL EASEMENT 3.00m WIDE

16.03m.
CHERYL B. QUIDET

PINES RIVER
Engineer IV

A = 520 sq. m.
DATE

LOT 1189 - B
19.70m.
19.70m.

S 77° 06' W
21.97m.

A = 371 sq. m.
LOT 1189 - A
LINE & GRADE

S 77° 20' W
N 77° 20' E
-D

N 79° 16' E
LOT 1188, CAD. 310
RROW N 22° 32' W
DPWH 6 5
3.00m.
OW 26.61m.
DPWH RR N22° 32
'W
LOT
OW A D
DPWH
RR R O
1 .
48.12m
. 'W
RR OW 18.51m N 22° 32
DPWH DATE

P.S.
'W
N22° 32
0-D
52, CAD. 31
LOT 12
51,
LOT 12 - D
CAD. 31
0 ARCHITECTURAL
PERSPECTIVE
AL ROAD
NOT TO SCALE C/L OF
NATION

LOT PLAN
SCALE 1: 500M
DATE

STRUCTURAL
PROPOSED TWO-STOREY
W/ ROOF DECK
RESIDENTIAL BUILDING
8° 26' 43" N
123° 48' 31" E

DATE

ELECTRICAL
S 15° 31' E
P.S.

46.66m.
S 15° 31' E

E
FENC
3.00m.
26.14m.
17.52m. S 15° 31' E W
S 15° 31' E YELLO

.
CONC
HOUSE RIVER
LEGAL EASEMENT 3.00m WIDE
RESIDENTIAL BUILDING W/

16.03m.

PINES
TE
L GA
BLUE STEE
TWO STOREY

PINES RIVER
ROOFDECK

HOUSE
E
POPOSED

. FENC
CONC
A = 520 sq. m.
19.70m.
19.70m.

DATE
LOT 1189 - B

ITE
THIS S
S 77° 06' W
21.97m.

MIZ
A = 371 sq. m.

TO OZA
LOT 1189 - A

SANITARY
S 77° 20' W
N 77° 20' E
-D

ER -
N 79° 16' E

ROP Y
ITY P RIVER
LOT 1188, CAD. 310

CIT PINES
5.573m.
OW N 22° 32' W TO C UIETA
6.489m. DPWH RR R OQ
O
3.00m.
26.61m. E
DPWH
RROW 'W BRIDG
N22° 32 PINES
A D
LOT + 247
RR OW R O K1737
DPWH .
48.12m
. 'W
RROW 18.51m N 22° 32
DPWH
P.S.

'W
N22° 32
D
DATE
0-
52, CAD. 31
LOT 12

BUREAU OF FIRE PROTECTION


,
LOT 1251 D
0-
CAD. 31

AL ROAD
NATION
C/L OF

SITE DEVELOPMENT PLAN LOCATION MAP PLAN


SCALE 1: 500M NOT TO SCALE
DATE
SEAL: PROFESSIONAL: PRC NO. PROJECT NAME AND LOCATION: APPROVED AS TO PLAN AND LOCATION: SHEET CONTENTS SHEET NO.
PTR NO.
PROPOSED TWO - STOREY PERSPECTIVE
PLACED ISSUED RESIDENTIAL BUILDING ALGUER P. KHO LOT PLAN 1
ARCHITECT DATE ISSUED WITH ROOF DECK OWNER SITE DEVELOPMENT PLAN 13
ADDRESS: T. I. N. LOCATION: PINES, OROQUIETA CITY ADDRESS: P-6 PINES, OROQUIETA CITY, MISAMIS OCCIDENTAL LOCATION PLAN
1 2 3
3.375m. 4.125m.

3.250m. 4.100m.
W5 W1

1.500m.

(4.1m x 3.0m)
BEDROOM 3

3.000m.
D3
W2

4.750m.

UP
1 2 3 1 2 3
D2
2.500m. 3.500m. 1.500m. W6 7.500m.

4.200m.

1.450m.
W5 W4 1.400m.
W3
A A 100mm THK. Parapet 100mm THK. Parapet
D2
1.500m.

Wall, H= 1200mm Wall, H= 1200mm


B

DOWN
D2

2.500m.
KITCHEN
D3 W5

3.250m.
4.600m.
D2
4.750m.

4.750m.
BEDROOM 2 D3

100mm THK. Parapet


UP

STORAGE ROOM
(3.30m. x 3.50m.) W1

Wall, H= 1200mm
(4.85m x 4.58m) (3.25m x 2.65m)
W1

4.750m.

3.500m.
W6 DINING AREA

2.175m.
4.200m.

W1 D2

1.350m.
W2

9.500m.
1.900m.
FIRE EXIT
TERRACE
B B
C D2
W2
3.100m.

LIVING AREA 1.250m. 2.650m.


D2

Wall, H= 1200mm
100mm THK. Parapet
BEDROOM 1 W7
(4.05m x 3.40m) W1
(3.30m. x 3.50m.)
4.750m.

4.750m.

4.750m.
3.300m. 4.050m.

Wall, H= 1200mm
100mm THK. Parapet
3.500m.

W1 D1

W2
1.500m.

PORCH SECONDFLOOR PLAN FIRE EXIT


(1.50m x 4.125m)
SCALE 1: 100M 100mm THK. Parapet 100mm THK. Parapet
Wall, H= 1200mm Wall, H= 1200mm
C C
W2
4.425m.
3.300m. 1.825m. 2.300m. 3.375m. 4.125m.

GROUNDFLOOR PLAN ROOFDECK PLAN


SCALE 1: 100M SCALE 1: 100M

SEAL: PROFESSIONAL: PRC NO. PROJECT NAME AND LOCATION: APPROVED AS TO PLAN AND LOCATION: SHEET CONTENTS SHEET NO.
PTR NO.
CONSTRUCTION OF TWO - STOREY GROUND FLOOR PLAN
PLACED ISSUED RESIDENTIAL BUILDING ALGUER P. KHO 2
ARCHITECT WITH ROOF DECK
SECOND FLOOR PLAN
DATE ISSUED OWNER 13
ROOF DECK PLAN
ADDRESS: T. I. N. LOCATION: PINES, OROQUIETA CITY ADDRESS: P-6 PINES, OROQUIETA CITY, MISAMIS OCCIDENTAL
3.000m. 6.750m.
CONC.FLAT ROOF APEX
0.075m.

200mm x 50mm CONC. STRIP

PARAPET WALL PAINT FINISH 2.700m.

SLAB EXTENSION 1.200m.


ROOF DECK LINE
BEAM SOFFIT 0.400m.

100mm THK. CHB W/ PAINT FINISH

3.500m.

BRICK WALL
2ND FLOOR LINE
BEAM SOFFIT SLAB EXTENSION 0.400m.

100mm THK. CHB W/ PAINT FINISH


CONC. CANOPY
4.000m.

FINISH FLOOR LINE

1.000m.
NATURAL GRADE LINE
FRONT ELEVATION RIGHT SIDE ELEVATION
SCALE 1: 100M SCALE 1: 100M
CONC.FLAT ROOF APEX
0.075m.

2.700m.

200mm x 50mm CONC. STRIP


1.200m.
ROOF DECK LINE
BEAM SOFFIT 0.400m.

100mm THK. CHB W/ PAINT FINISH

3.500m.

2ND FLOOR LINE


BEAM SOFFIT 0.400m.

100mm THK. CHB W/ PAINT FINISH


CONC. CANOPY
4.000m.

FINISH FLOOR LINE

1.000m.
NATURAL GRADE LINE
REA ELEVATION LEFT SIDE ELEVATION
SCALE 1: 100M SCALE 1: 100M

SEAL: PROFESSIONAL: PRC NO. PROJECT NAME AND LOCATION: APPROVED AS TO PLAN AND LOCATION: SHEET CONTENTS SHEET NO.
PTR NO.
PROPOSED TWO - STOREY
PLACED ISSUED RESIDENTIAL BUILDING ALGUER P. KHO 3
ELEVATIONS
ARCHITECT DATE ISSUED WITH ROOF DECK OWNER 13
ADDRESS: T. I. N. LOCATION: PINES, OROQUIETA CITY ADDRESS: P-6 PINES, OROQUIETA CITY, MISAMIS OCCIDENTAL
FULL WELD
5
8" x 100mm EXPANSION BOLT
25cm x 25cm x 38" STEEL
PLATE 25cm x 25cm x 38"STEEL
PLATE

UP
3 2 1 1.00m.
4 0.30m.
5 0.80m. 0.60m.
FULL WELD
6
2.70m. 7
8 2- 4" x 6" STEEL STRINGER 0.20m.
9 50mm WOOD THREAD
10
3
11 8" STEEL PLATE
1
12 4" HEX BOLT
13 0.9m.

2.40m.

2.10m.

2.10m.
TO 2ND FLR. STAINLESS STEEL HARD RAILS
14 15 16 17 18 19

3.50m.

SEE STAIR
DETAILS OF STAIR
DETAIL F. F. L.
SCALE 1: 150M

D1 D2 D3

4.00m. SOLID PANEL DOOR SOLID PANEL DOOR PVC DOOR


W/ 2" x 5" DOOR JAMB W/ 2" x 5" DOOR JAMB (3 SETS)
1 2 3
(1 UNIT) (7 UNITS)
A

F.F.L.
C-CHANNEL
A
TRANSVERSAL CEILING 1.50m. 1.2 m .8 m
1.00m. JOIST SPACED @ METAL FURRING
N.G.L. 600mm O.C. B.W. SUSPENSION HANGER
ANCHORED TO SLAB AND
LIGHTING LIGHTING
BEAMS FIXTURES
S1 FIXTURES
1.50m.

1.50m.

1.5 m
BOTTOM OF SLAB
0.600m. BOTTOM OF BEAM

0.40m.

2.2 m
PVC CEILING PANEL
FLAT CEILING
DINING AND LIVING AREA
KITCHEN PORCH
2.00m. B 3.40m. FROM F.F.L. 3.40m. FROM F.F.L.

DOUBLE METAL FURRING


LONGITUDINAL CROSS SECTION (LONGITUDINAL) CEILING JOIST
SECTION A - A

.9 m

.9 m
SPACED @ 400mm O.C. B.W.
SCALE 1: 150M SCALE 1: 200M
F. F. L.

.19 m
C
W1 W2 W3

SLIDE TYPE WINDOW SLIDE TYPE WINDOW FIXED TYPE WINDOW


2.70m. A
W/ 6mm THK. GLASS PANEL W/ 6mm THK. GLASS PANEL W/ 6mm THK. GLASS PANEL
IN ANALOK FRAME IN ANALOK FRAME IN ALUMINUM FRAME
CEILING PLAN (6 SETS) (5 SETS) (1 SET)

SCALE 1: 200M
.6 m
.8 m .6 m .5 m

.3 m
3.50m.

.3 m
.5 m

1.2 m
2.1 m
2ND FLR. LINE

1.85 m
1.65 m
0.60m.
CEILING LINE

.9 m
4.00m. MODULAR CABINET
F. F. L.
2" x 6" WOODEN STRIP 0.30m.
4.0m.

4.0m.
W4 W5 W6 W7

0.750m.
3.40m.

3.40m.
F.F.L.

1.00m.
0.80m.

N.G.L. AWNINGTYPE WINDOW AWNINGTYPE WINDOW AWNINGTYPE WINDOW AWNINGTYPE WINDOW


0000
W/ 6mm THK. GLASS PANEL W/ 6mm THK. GLASS PANEL W/ 6mm THK. GLASS PANEL W/ 6mm THK. GLASS PANEL
IN ANALOK FRAME IN ANALOK FRAME IN ANALOK FRAME IN ANALOK FRAME
0.850m.

0.850m.
1.50m.
(1 SET) (3 SETS) (2 SETS) (1 SET)
F. F. L.
0.40m. 0.60m. 0.40m. 0.40m. 0.40m. 0.35m. 0.40m. 0.40m. 0.60m. 0.30m.
2.00m. 0.60m.

SCHEDULE OF DOORS AND WINDOWS


TRANSVERSE CROSS SECTION
KITCHEN BLOW - UP DETAIL
SCALE 1: 150M
SCALE 1: 100M

SEAL: PROFESSIONAL: PRC NO. PROJECT NAME AND LOCATION: APPROVED AS TO PLAN AND LOCATION: SHEET CONTENTS SHEET NO.
PTR NO. CROSS SECTIONS
PROPOSED TWO - STOREY SCHEDULE OF DOORS
PLACED ISSUED RESIDENTIAL BUILDING ALGUER P. KHO AND WINDOWS 4
ARCHITECT DATE ISSUED WITH ROOF DECK OWNER DETAILS OF STAIR
CEILING PLAN 13
ADDRESS: T. I. N. LOCATION: PINES, OROQUIETA CITY ADDRESS: P-6 PINES, OROQUIETA CITY, MISAMIS OCCIDENTAL KITCHEN BLOW - UP DETAIL
ARCHITECTURAL NOTES :
FLOORING : WALL : DOORS & ACCESSORIES ... continuation (DOORS & ACCESSORIES) : CEILING :
Tiles , other flooring materials shall be approved by · Doors & its accessories such as hinges, Use 4.5mm thk. Fiber Cement Board for
Owner& installed by Contractor. · CHB wall exterior use 6" while knobs, door stopper, door · Apply 2 coats Sanding Sealer (Paint ceiling w/ Metal furring as ceiling support;
All consumable materials such as cement, tile adhesive, interior use 4" until floor to floor closer & among others shall be supplied Brush) supplied & installed by Contractor.
tile grout & other materials shall be shouldered by the height. & installed by Contractor. · Use Oil wood stain for color (Waste Fiber Cement Board painting: use Marine
Contractor. · Moulding,toilet cubicle walls, · All paints for doors & door jambs shall be Cotton) Epoxy as joint sealer & top w/ pre-mixed
Grout for all wet areas like bedroom t & b, public toilets baseboard & other decorative items done by the Contractor · Apply 1 coat Sanding Sealer (Paint ·
jointing compound 2-coats Flat Latex as
& other areas shall be provided with grout sealer. shall be approved by Owner · Door jambs (delivered assembled) shall Brush) ·
final paint applied using roller.
Sample of tiles, grout & other floor finishes shall be be supplied & installed by Contractor. · Apply 2nd coat Oil wood stain ·
& installed by Contractor. 2' x 2' Acoustic board 1"x 1 21" as main Tee
submitted to the Owner for approval. · Hardwares for installing jambs such as 4 coats Sanding Sealer (Paint Brush) ·

· Glass wall shall be approved by Owner nails & bolts shall be provided by the · & 1"x 1" as Cross-Tee
All joints between flooring, either the same or different · Apply 3rd coat Oil wood stain
supplied & installed by the Contractor Contractor. Exposed areas w/ paint apply concrete
types of materials shall be straight & true without cracks · 1 coat Sanding Sealer (Paint Brush) ·

· All wooden doors, door and window neutralizer, use (Plain Roller), leave the
or chips. · Top coat Dead flat lacquer (Automotive ·
· Acoustic wall use STC-rating 45 jambs shall be shop made, kiln dried & surface overnight to cure. Wash surface
Upon completion, clean all tiles surfaces before spray) ·
·

· Dry wall partitions use 4.5 mm thk. treated. using clean water.Patch all temperature
turn-over. · Supplied & applied by Contractor ·

· Elevation of doors & door jambs should cracks, corner joints using (Plain Roller) .1
EPOXY FLOORING: fiber cement board on metal stud ·
·

be approved by the Owner. coat Acrytex Primer (Plain Roller).1 coat


Inspect all surfaces to be painted for defects & should be frames. AUTOMOTIVE PAINT: - Metal ·

· All glass windows, window accessories & Flat latex (Plain Roller) . 2 coats Top Coat
corrected before starting work. · All airconditioning unit covers use 4" · Inspect all surfaces to be painted for
consumables shall be installed & any choice of color (Plain Roller) to be
Allow at least 2 weeks curing time before any application. thk. CHB. defects & should be corrected before ·

supplied by Contractor. starting work. approved by Owner,


Cleaning & washing of concrete surface before applying ·

any paint. · Sample of finishing shall be submitted to · Apply 1 coat Epoxy Primer (Plain Roller) Exposed areas w/o paint concrete shall be
· Details for Landscaping, water features, the Owner's for approval.
Apply seal for Primer (Plain Roller), dry for 4 hours prior · Apply 2 coats Automotive Paint as top ·
smooth plastered finish. Metal w/ corrosion
swimming pool,dumbwaiters & the like shall be coat any choice of color (Spray) to be ·
any application. apply w/ rust converter 1 -coat Primer
Patching to even out surface. furnished by the Contractor VARNISH PAINT: approved by Owner. 1-coat QDE,applied in roller.
Apply 2nd coat seal, dry for 4 hours prior any application
and approved by the Owner · Inspect and prepare all surfaces to be · Supplied & applied by Contractor Cornice & decorative item shall be
(Plain Roller) painted for defects & should be corrected approved by Owner & installed by
·
2 coats Powerfloor as top coat (Plain Roller), color to be before starting work. Contractor.
approved by Owner. · Apply woodfiller to seal all cracks, nail · Color & Texture sample shall be submitted

holes and other defects. · to the Owner for approval.

EXTERIOR PAINTING: INTERIOR PAINTING: VARNISH PAINT: (...Cont. INTERIOR PAINTING)


· Inspect all surface to be painted for defects & should be corrected LATEX SYSTEM · Inspect and prepare all surfaces to be painted for defects & should be
before starting work. · Inspect all surface to be painted for defects & should be corrected before corrected before starting work.
· Allow at least (2) two weeks curing time before any application. starting work. · Apply woodfiller to seal all cracks, nail holes and other defects.
· Cleaning and washing of concrete surface before applying any paint. · Allow at least 2 weeks curing time before any application. · Apply 2 coats Sanding Sealer (Paint Brush)
· 1 coat Powermix Primer (Plain Roller) · Cleaning & washing of concrete surface before applying any paint. · Use Oil wood stain for color (Waste Cotton)
· 2 coats w/ Cement Power mix (Plain Roller). · Apply concrete neutralizer, use (Plain Roller), leave the surface overnight · Apply 1 coat Sanding Sealer (Paint Brush)
· 1 coat Flat Latex (Plain Roller) to cure. · Apply 2nd coat Oil wood stain
· 2 coats wallguard top coat any choice color (Plain Roller) to be · Wash surface using clean water. · 4 coats Sanding Sealer (Paint Brush)
approved by Owner · Patch all temperature crack, corner joints, opening using (Plain Roller) · Apply 3rd coat Oil wood stain
· 1 coat Acrytex Primer (PlainRoller) · 1 coat Sanding Sealer (Paint Brush)
ALUMINUM CLADDING: · For patching use Acrytex cast until wall relatively plain and smooth. · Top coat Dead Flat lacquer (Automotive spray)
· Use 4 mm thk. PVDF aluminum panel w/ aluminum framing shop · 1 coat Flat Latex (Plain Roller) · Supplied & applied by Contractor
drawing should be submitted for Owner's approval. · 2 coats Top Coat any choice of color (Plain Roller) to be approved by AUTOMOTIVE PAINT : Wood Cabinet
· Cladding works shall be approved by the Owner & Owner. · Inspect and prepare all surfaces to be painted for defects & should be
installed by Contractor. · Supplied & applied
: by Contractor. corrected before starting work.
· Apply 1 coat automotive primer surfacer (spray)
FIXED GLASS AND WINDOWS: WALL WATER PROOFING · Apply full patch 1 coat Body filler to seal
· Shop drawing should be submitted prior to actual execution to be · Cleaning and washing of concrete surface · Apply 1 coat automotive primer surfacer (spray)
· before applying
Supplied & any paint.
applied by Contractor · Apply full patch using automotive lacquer putty.
approved by the Owner. · 1 coat Primer (Plain Roller)
ROOFING & GUTTER: · 2 coats Power mix (Plain Roller) · Apply 2 coats automotive primer surfacer (spray)
· Prior to installation of Roof Framing must be well-painted with Red · Apply 3 coats automotive lacquer for top coat any choice of color to be
Oxide. approved by Owner.
· Roofing sheet should be .6mm thk. and insulated with 10mm thk. · Seal the top coat surface with 1 coat top coat clear.
double sided aluminum P.E. Foam Insulation Supplied & applied by Contractor
· All accessories like tekscrew, blind rivets and others must be treated
with Water Proofing.

SEAL: PROFESSIONAL: PRC NO. PROJECT NAME AND LOCATION: APPROVED AS TO PLAN AND LOCATION: SHEET CONTENTS SHEET NO.
PTR NO.
CONSTRUCTION OF TWO - STOREY
PLACED ISSUED RESIDENTIAL BUILDING ALGUER P. KHO ARCHITECTURAL NOTES 5
ARCHITECT DATE ISSUED WITH ROOF DECK OWNER 13
ADDRESS: T. I. N. LOCATION: PINES, OROQUIETA CITY ADDRESS: P-6 PINES, OROQUIETA CITY, MISAMIS OCCIDENTAL
1 2 3 1 1a 2 3 1 1a 2 3
3.375m. 4.125m.
1.126m. 2.249m. 4.125m. 1.475m. 1.900m. 4.125m.

F1/C1 F1/C1 F1/C1 C3 C3 C3 C3 C4 C3 C3


A A A
FTB FTB SFB SFB RB RB RB

1.575m.
3.825m.

2.575m.
3.075m.

RB

RB
A1
WF SFB
4.750m.

SFB
FTB
FTB

FTB

RB

RB
4.750m.
125mm THK. CONC.SLAB A2 125mm THK. CONC.SLAB

SFB
3.175m.
100mm THK. SLAB ON FILL (SEE SLAB DETAILS) C4 RB C4 RB (SEE SLAB DETAILS)
w/ 10mm Ø BARS @ 300mm
B.W. & REST @ 0.10m

2.175m.
COMPACTED GRAVEL
ELEV = +1.0m

RB

RB
F2/C2 C3 C3 C3 C3 C3 C3

F1/C1
F1/C1

B B B

1.225m.

1.225m.
FTB FTB SFB C4 RB

B1 B1
WF SFB RB
4.750m.

SFB

SFB

SFB
FTB
FTB

FTB

RB

RB

RB
4.750m.

3.525m.

3.525m.
WF

FTB FTB C3 SFB C3 SFB C3 C3 RB C3 RB C3


C C C
F1/C1 F1/C1 F1/C1

FOUNDATION PLAN SECONDFLOOR BEAM PLAN ROOF BEAM PLAN


SCALE 1: 100M SCALE 1: 100M SCALE 1: 100M

10MM.Ø HOR. REINF. BARS SPACED


@ EVERY 3 LAYERS OF CHB

SCHEDULE OF COLUMN SCHEDULE OF FOOTINGS


COLUMN MARK LATERAL TIES DIMENSIONS (mm) THICKNESS DEPTH
MARK REBARS (Ø , mm) 4" THK. CHB W/ 10MM.Ø VERT. REINF.
0.30m
Length(L) Width(W) (T , mm) (D , mm) BARS SPACED @ 0.60 M.O.C.
5 @ 50mm, 8 @ 100mm,
C1 0.30m 7 @ 150 mm, F1 2000 2000 400 1900 12 - 20mm Ø BOTHWAYS
REST @ 200 mm
F2 2000 2000 400 1900 12 - 20mm Ø BOTHWAYS
FINISH FLOOR LINE 8 - 20mm Ø VERT. BARS
N.G.L.
1.00m.

0.35m SCHEDULE OF BEAMS 10mm Ø STRAIGHT BARS


FOOTING TIE BEAM
0.25m 0.25m
NATURAL GROUND LEVEL 5 @ 50mm, 8 @ 100mm,
AT SUPPORTS AT MID-SPAN SPACED AS SHOWN
2- 20mm Ø TOP BARS 10mm Ø STIRRUPS,
C2 0.35m 7 @ 150 mm, 6 - 20mm Ø TOP BARS 3 @ 50mm, 4 @ 100mm, 0.450m.
REST @ 200 mm FTB 0.400m 0.400m
5 @ 150mm,
REST @ 200mm OWN CENTER

2- 20mm Ø BOT. BARS 6 - 20mm Ø BOT BARS


0.150m. 50mm COMPACTED GRAVEL
8 - 25mm Ø VERT. BARS
BACKFILL BACKFILL 0.30m 0.25m 0.25m
D L AT SUPPORTS AT MID-SPAN 0.300m. 3- 10MM.Ø
2- 20mm Ø TOP BARS 10mm Ø STIRRUPS,
5 @ 50mm, 8 @ 100mm, 6 - 20mm Ø TOP BARS 3 @ 50mm, 4 @ 100mm, STRAIGHT BARS
C3 0.30m 7 @ 150 mm, SFB 0.400m 0.400m
5 @ 150mm,
REST @ 200mm OWN CENTER
ELEVATION
REST @ 200 mm
2- 20mm Ø BOT. BARS 6 - 20mm Ø BOT BARS 10MM.Ø TIES
T

8 - 16mm Ø VERT. BARS


SPACED @ 0.30m
0.25m 0.25m. 0.25m.
100mm THK. GRAVEL FILL
O.C.
W 3 @ 50mm, 4 @ 100mm, 2- 20mm Ø TOP BARS
10mm Ø STIRRUPS,
3 @ 50mm, 4 @ 100mm,
C4 0.25m 5 @ 150 mm, RB 6 - 20mm Ø TOP BARS
5 @ 150mm,

TYP. COLUMN & FOOTING DETAIL


REST @ 200 mm
0.40m. 0.40m. REST @ 200mm OWN CENTER
PLAN
2- 20mm Ø BOT. BARS 6 - 20mm Ø BOT BARS
4- 16mm Ø VERT. BARS
SCALE 1: 50M WALL FOOTING DETAIL
SCALE 1 : 25M
SEAL: PROFESSIONAL: PRC NO. 0149850 PROJECT NAME AND LOCATION: APPROVED AS TO PLAN AND LOCATION: SHEET CONTENTS SHEET NO.
PTR NO. 0208619 FOUNDATION PLAN
CONSTRUCTION OF TWO - STOREY SECOND FLOOR BEAM PLAN
HAROLD E. EBILANE PLACED ISSUED OROQUIETA CITY RESIDENTIAL BUILDING ALGUER P. KHO ROOF BEAM PLAN 6
CIVIL ENGINEER DATE ISSUED JULY 04, 2022 WITH ROOF DECK OWNER TYP. COLUMN & FOOTING DETAIL
SCHEDULE OF COLUMN, FOOTING & BEAM
13
ADDRESS: T. I. N. 336 - 920 - 766 LOCATION: PINES, OROQUIETA CITY ADDRESS: P-6 PINES, OROQUIETA CITY, MISAMIS OCCIDENTAL WALL FOOTING DETAIL
L
L/4 + 12Ø L/4 + 12Ø
TOP LINE OF THE BEAM

SEE BEAM SCHEDULE

50
10mm Ø STIRRUPS, 3 @ 50mm, 4 @ 100mm,
5 @ 150mm, REST @ 200mm ON CENTER
L/5 - 12Ø L/5 - 12Ø

TYPICAL BEAM DETAIL


NOT TO SCALE

12mm Ø BEND BAR(B) SPACED @ 150mm


SECTION 12mm Ø CUT BAR SPACED @ 250mm
10mm TEMP. BAR SPACED @ 300mm
SLAB SCHEDULE (ONE WAY)
L 12mm BOT. BAR SPACED @ 150mm
12mm TOP BAR SPACED @ 250mm
ALONG SHORT DIRECTION ALONG LONG DIRECTION
SLAB THICKNESS
REBAR BAR BAR DIMENSIONS (mm) REBAR BAR BAR DIMENSIONS (mm)
L/4 L/2 L/4 MARK (mm)
(mm Ø) TYPE a b c (mm Ø) TYPE a b c
TOP VIEW
A TEMP. BAR L - -
LONGITUDINAL L - -
S-2 125 10 B BEND BAR L/3 - 35 100 L/3 - 70 10 A BAR

C CUT BAR L/3 - -

10mm Ø BEND BAR (B) SPACED @ 150mm


10mm Ø CUT BAR (C) SPACED @ 250mm
SECTION 10mm Ø TEMP. BAR (A) SPACED @ 250mm
L

L/4 L/4
TYPICAL DETAIL OF SLAB (S-2)
NOT TO SCALE
TYPICAL DETAIL OF SLAB (S-2) TOP VIEW
NOT TO SCALE

SLAB SCHEDULE (TWO WAY) BAR TYPES


a
ALONG SHORT DIRECTION ALONG LONG DIRECTION TYPE A
SLAB THICKNESS
REBAR BAR BAR DIMENSIONS (mm) REBAR BAR BAR DIMENSIONS (mm)
MARK (mm) b a b
(mm Ø) TYPE a b c (mm Ø) TYPE a b c TYPE B

A TEMP. BAR L - - A TEMP. BAR L - -


S-1 125 12 B BEND BAR L/3 - 35 100 L/3 - 70 10 B BEND BAR L/3 - 35 100 L/3 - 70
C CUT BAR L/3 - - C CUT BAR L/3 - -

SEAL: PROFESSIONAL: PRC NO. 0149850 PROJECT NAME AND LOCATION: APPROVED AS TO PLAN AND LOCATION: SHEET CONTENTS SHEET NO.
PTR NO. 0208619
CONSTRUCTION OF TWO - STOREY TYPICAL BEAM DETAIL
HAROLD E. EBILANE PLACED ISSUED OROQUIETA CITY RESIDENTIAL BUILDING ALGUER P. KHO TYPICAL DETAIL OF SLAB (S-1) 7
CIVIL ENGINEER DATE ISSUED JULY 04, 2022 WITH ROOF DECK OWNER TYPICAL DETAIL OF SLAB (S-2)
SCHEDULE OF SLAB
13
ADDRESS: T. I. N. 336 - 920 - 766 LOCATION: PINES, OROQUIETA CITY ADDRESS: P-6 PINES, OROQUIETA CITY, MISAMIS OCCIDENTAL
DESIGN CRITERIA: GENERAL NOTES AND SPECIFICATIONS :
A. LIVE LOAD
ROOF - - - - - 1.00 kPa 1. IN THE INTERPRETATION OF THESE DRAWINGS, INDICATED DIMENSIONS SHALL GOVERN, DISTANCES OR SIZES SHALL NOT BE SCALED FOR
CONSTRUCTION PURPOSES.
B. DEAD LOAD 2. UNLESS OTHERWISE INDICATED, ALL DIMENSIONS ARE IN MILLIMETERS.
CONRETE - - - - 23.54 kN/cu.m 3. ALL REINFORCED CONCRETE WORKS SHALL BE DONE IN ACCORDANCE WITH THE ACI - 318-95 BUILDING CODE, AS SO FAR AS THEY DO NOT
STEEL - - - - 76.93 K/cu.m CONFLICT WITH THE LOCAL BUILDING CODE REQUIREMENTS.
150mm Thick CHB - - - - 2.73 kPa
4. ALL WORKS SHALL CONFORM TO THE PROVISIONS OF THE NATIONAL STRUCTURAL CODE OF THE PHILIPPINES (NSCP) 2015 EDITION.
100mm Thick CHB - - - - 2.10 kPa

C. ALLOWABLE DESIGN STRESSES FOUNDATION :


1. FOUNDATION DESIGN WAS BASED ON AN ALLOWABLE SOIL BEARING CAPACITY OF 95.76 KPa .
1. CONCRETE (Compressive Strength28days)
2. PROVIDE TEMPORARY REMOVAL OF WATER FROM ANY SOURCE DURING CONSTRUCTION. DEWATERING SHALL BE CAREFULLY & PROPERLY
f'c - - - 20.70 MPa PERFORMED TO AVOID DISTURBING THE FOUNDATION & SLAB BEARING SURFACE .
fc - - - 9.36 MPa 3. THE CONTRACTOR SHALL DESIGNED, INSTALL AND MONITOR ALL EXCAVATION RETENTION SYSTEMS AS REQUIRED FOR THE PROTECTION OF THE
ADJACENT PROPERTY AND PROVIDE ALL MEASURES AND PRECAUTIONS NECESSARY TO MINIMIZE SETTLEMENT AND PREVENT DAMAGE TO
2. REINFORCING STEEL BARS ADJACENT EXISTING OR NEW CONSTRUCTION .
a.16mmØ & Greater (Intermediate Grade 40 Deformed Bars) 4. INVESTIGATE ALL FACILITIES UNDERNEATH THE GROUND SUCH AS WATER PIPE LINE, ELECTRICAL POWER LINE, DRAINAGE SYSTEM AND ALL
fy - - - 275.00 Mpa
OTHER STRUCTURES EMBEDDED UNDER THE SOIL .
fs - - - 138.00 Mpa
5. FILLING MATERIALS SHALL COMPACTED 95% RELATIVE COMPACTION IN ACCORDANCE WITH ASTM 0698 . FILL SHOULD BE PLACED IN LIFTS
b. 12mmØ & Smaller (Intermediate Grade 40 Deformed Bars)
fy - - - 230.00 Mpa NOT EXCEEDED 200mm PER LAYER .
fs - - - 124.00 Mpa

3. STRUCTURAL STEEL ASTM A36 STRUCTURAL STEEL :


For Trusses, Bracings & Struts 1. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 WITH MINIMUM STRENGTH fy = 248.00 MPa .
fy - - - 248.00 Mpa (36,000 psi)
2. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM WITH THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) CODE OF PRACTICE.
4. LIGHT GAUGE CHANNEL PURLINS
3. THE CONTRACTOR SHALL FURNISH CONNECTORS, CLIP ANGLES, PLATES, BRACINGS ETC. REQUIRED FOR THE COMPLETION OF THE WORK EVEN
fy - - - 124.00 Mpa (18,000 psi)
5. MASONRY UNIT - C.H.B. IF SUCH ITEMS WAS NOT SHOWN ON THE PLANS.
fm' = 2.40 4. IN ACTUAL FABRICATION OF STEEL COLUMNS AND TRUSSES, MEMBERS MEETING AT A POINT THEIR GRAVITY AXIS INTERSECTS AS NEARLY AS
D. WIND LOAD PRACTICABLE AT A COMMON POINT.
P = CeCqQsI 5. THE CONTRACTOR SHALL PROVIDE TEMPORARY ERECTION BRACINGS AND SHORINGS & MAKE ACTUAL MEASUREMENTS IN THE FIELD PRIOR TO
WHERE : FABRICATRIONS/INSTALLATIONS OF TRUSSES AND COLUMNS.
Ce = 0.63 6. WELDING PROCESS AWS E60xx ELECTRODES. MINIMUM TENSILE STRENGTH OF Fu=415 MPa.
Cq = 0.30 INWARD
7. ALL HIGH TENSION BOLTS SHALL CONFORM TO ASTM A325; NUTS SHALL CONFORM ASTM A563; WASHERS ASTM F436; ANCHOR BOLTS ASTM A307.
0.70 OUTWARD
WIND VELOCITY = 175 KPH
IMPORTANCE FACTOR,
I = 1.00
REINFORCING STEEL :
1. MINIMUM GRADE 40 (275 MPa) DEFORMED BARS.
2. ALL REINFORCING BARS SHALL BE SUPPORTED IN CONFORMANCE WITH THE MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED
CONCRETE STRUCTURE ( ACI 315 LATEST EDITION ) .
E. SEISMIC LOAD
3. FOR WELDABLE STEEL / DEFORMED BARS ( BAR CODE , RED COLOR ) WELD SHALL CONFORM TO THE PROVISION OF THE STRUCTURAL
ZIC
V= W WELDING CODE REINFORCING STEEL, AWS D 1.4 .
Rw
4. A FULL WELDED SPLICE SHALL HAVE BARS BUTTED AND WELDED TO DEVELOP IN TENSION AT LEAST 125% OF THE SPECIFIED YIELD STRENGTH
LET :
fy OF THE BAR .
1.25S
C= < 2.75 5. ALL BARS SHALL BE CLEAN AND RUST FREE PRIOR TO CONCRETE POURING .
T 3/4
WHERE :
T = C t (hn ) 3/4
R w = 12
CONCRETE :
W = TOTAL DEAD WEIGHT OF THE BUILDING 1. COMPRESSIVE STRENGTH OF CONCRETE SHALL BE 20.70 MPa ( MINIMUM ) .
2. AGGREGATE SIZE TO BE USE FOR BEAMS, COLUMNS, SLABS, SHALL BE 20mm Ø . FOR FOOTINGS AND SLAB ON GRADE SHALL BE 25mmØ .
3. CEMENT USED IN THE WORK SHALL BE " PORTLAND CEMENT " .
4. WATER USED IN MIXING CONCRETE SHALL BE CLEAN AND FREE FROM INJURIOUS AMOUNTS OF OILS , ACIDS, ALKALIS, SALTS, ORGANIC
F. FOUNDATION
MATERIALS OR OTHER SUBSTANCES DELETERIOUS TO CONCRETE OR REINFORCEMENT .
ASSUMED MINIMUM SOIL BEARING CAPACITY IS EQUAL
5. ALL CONCRETES SHALL BE MIXED UNTIL THERE IS A UNIFORM DISTRIBUTION OF MATERIALS AND SHALL BE DISCHARGED COMPLETELY
TO 95.76 kPa. (2,000 PSF)
BEFORE THE MIXER IS RECHARGED .
6. FORMS SHALL BE SUBSTANTIAL AND SUFFICIENTLY TIGHT TO PREVENT LEAKAGE OF MORTAR AND OR CONCRETE .
NOTE :
7. FORMS SHALL BE PROPERLY BRACED OR TIED TOGETHER TO MAINTAIN THE FINAL POSITION AND SHAPE OF THE STRUCTURE .
1. IN CASE THE ACTUAL SOIL PRESSURE CAPACITY IS FOUND
LESS THAN THE ASSUMED VALUE OF 95.76 kPA, NOTIFY THE
DIRECTOR, BUREAU of DESIGN FOR PROPER REVISION OF CONSTRUCTION JOINT:
FOOTINGS. 1. CONSTRUCTION JOINT NOT INDICATED ON THE PLANS SHALL BE MADE SO AS TO LEAST IMPAIR THE STRENGTH OF THE STRUCTURE AND SHALL BE
SUBJECT TO THE APPROVAL OF THE ENGINEER EXCEPT SLAB ON GRADE.
2. NO FOOTING SHALL REST ON FILL 2. UNLESS SHOWN OTHERWISE, SLAB ON GRADE SHALL HAVE CONTROL JOINTS SPACED AT 6000mm MAXIMUM CENTER TO CENTER.
3. BEAMS CONSTRUCTION JOINTS SHALL BE LOCATED WITH IN THE MIDDLE THIRD OF THE SPA. IT WAS PROVIDED WITH 3 EXTRA STIRRUPS
@ 75mm O.C. ON EACH SIDE OF THE JOINT .

SEAL: PROFESSIONAL: PRC NO. 0149850 PROJECT NAME AND LOCATION: APPROVED AS TO PLAN AND LOCATION: SHEET CONTENTS SHEET NO.
PTR NO. 0208619
CONSTRUCTION OF TWO - STOREY
PLACED ISSUED OROQUIETA CITY ALGUER P. KHO DESIGN CRITERIA
HAROLD E. EBILANE RESIDENTIAL BUILDING
GENERAL NOTES AND
8
CIVIL ENGINEER DATE ISSUED JULY 04, 2022 WITH ROOF DECK OWNER
SPECIFICATION 13
ADDRESS: T. I. N. 336 - 920 - 766 LOCATION: PINES, OROQUIETA CITY ADDRESS: P-6 PINES, OROQUIETA CITY, MISAMIS OCCIDENTAL
SEPTIC VAULT
75mm Ø PIPE VTR 75mm Ø PVCSS 75mm Ø PIPE VTR 75mm Ø PVCSS
MH MH MH
WATERLINE WATERLINE
100mm Ø PVCSS

75mm Ø PIPE VTR


SH F FD SH
100mm Ø PVCSS FD LAV DS DS
75mm Ø PVCWS F 2.080m. 1.990m.
CB CB 100mm Ø DOWNSPOUT WC
RISER
RISER BEDROOM WC
SH
F
FD LAV LAV
WC KS
KITCHEN

KS
TO WATER
SOURCE
DINING

STOCKROOM

BEDROOM
LIVING

PORCH

BEDROOM

SECONDFLOOR SANITARY AND WATERLINE PLAN


PORCH ROOFDECK SANITARY AND WATERLINE PLAN
SCALE 1: 100M
SCALE 1: 100M

GROUNDFLOOR SANITARY AND WATERLINE PLAN


SCALE 1: 100M

REINFORCED CONC. MANHOLE


3.50m. 0.50m. WITH STEEL MOUNTED HANDLE
MANHOLE MANHOLE MANHOLE

0.150m. 0.150m.
0.15m. 1.20m. 0.10m. 1.20m. 0.10m. 1.20m. 0.15m. 0.30m AIR SPACE
10 mm Ø REBARS
SPACED @ 200 mm BOTHWAYS
INLET
INLET
OUTLET

0.50m. 0.50m. 150 mm THK. CHB

2.00m.
100 mm THK. CHB
1.50m.

VERTICAL BARS 12mm Ø


SPACED @ 600mm O.C.
MANHOLE MANHOLE MANHOLE
DIGESTIVE
CHAMBER
LEACHING LEACHING
CHAMBER CHAMBER
HORIZONTAL BARS 10mm Ø
SPACED @ EVERY 3-LAYERS

0.150m. 0.150m.
10 mm Ø REBARS
SPACED @ 200 mm BOTHWAYS
SEPTIC VAULT DETAIL
SCALE 1: 40M

SEAL: PROFESSIONAL: PRC NO. 0012623 PROJECT NAME AND LOCATION: APPROVED AS TO PLAN AND LOCATION: SHEET CONTENTS SHEET NO.
PTR NO. 0195714
CONSTRUCTION OF TWO - STOREY GROUND FLOOR SANITARY AND WATERLINE PLAN
JUSTIN JAN M. DIGAL PLACED ISSUED OROQUIETA CITY RESIDENTIAL BUILDING ALGUER P. KHO SECOND FLOOR SANITARY AND WATERLINE PLAN 9
ROOF DECK SANITARY AND WATERLINE PLAN
MASTER PLUMBER DATE ISSUED MARCH 24, 2022 WITH ROOF DECK OWNER ISOMETRIC PLAN
SEPTIC VAULT DETAIL
13
ADDRESS: T. I. N. 727 - 842 - 908 LOCATION: PINES, OROQUIETA CITY ADDRESS: P-6 PINES, OROQUIETA CITY, MISAMIS OCCIDENTAL
SH VTR
75
mm
Ø
PIP
E VT
R

LAV WC F 40cm x 40cm


Floor Tiles
10
0m
m
DIS LAV FD Ø
PV
TRIB CS 75
UT WC S mm
KS IO Ø
NP PV
IPE CW
S
SH KS 10
0
A
mm
DS Ø
PV
KS C
(D
OW
KS NS
DS PO
F UT
)
WC LAV
LAV
DI
ST
FD
10
RI 0m
BU
TIO
WC m
Ø
N WC PV
PIP LA C
(D
E V OW
NS
PO
UT)
SH BE
DR BE
O OM DR
OO A
M
F WC MH SE
RIS PT
IC
LAV ER MH VA
UL
LA
V
T
MH
CO
FD
CO BLOWUP DETAIL OF BATHROOM
KS WC

CB
KS
SCALE 1: 50M

KIT CB
CH KS
EN KIT
CH
EN
DIN M

ING
SOTO W
UR AT
CE ER
DIN
ING
LIV
ING
LIV
I NG
CEILING LINE

WATERLINE ISOMETRIC PLAN PLAN SANITARY ISOMETRIC PLAN PLAN


SCALE 1: 100M SCALE 1: 100M

30cm x 60cm
Wall Tiles
0.600m. 3.00m.
0.600m.
0.100m. 0.400m. 0.100m.
0.100m. 0.400m. 0.100m. 1.80m.
LAVATORY
3" THK. CONCRETE
CONCRETE MANHOLE COVER
MANHOLE COVER 0.80m.
0.100m. 4"Ø PVC PIPE WATER CLOSET
4"Ø PVC PIPE
FINISH FLOOR LINE

0.600m. 0.400m.
INLET
INLET OUTLET OUTLET
0.100m. SECTION A - A
10MM.Ø VERT. SCALE 1: 50M
PLAN & HOR. BARS
SPACED AS
DETAILS OF CATCH BASIN SECTION
SHOWN
SCALE 1: 25M

SEAL: PROFESSIONAL: PRC NO. 0012623 PROJECT NAME AND LOCATION: APPROVED AS TO PLAN AND LOCATION: SHEET CONTENTS SHEET NO.
PTR NO. 0195714
CONSTRUCTION OF TWO - STOREY WATERLINE ISOMETRIC PLAN
JUSTIN JAN M. DIGAL PLACED ISSUED OROQUIETA CITY RESIDENTIAL BUILDING ALGUER P. KHO SANITARY ISOMETRIC PLAN 10
MASTER PLUMBER DATE ISSUED MARCH 24, 2022 WITH ROOF DECK OWNER DETAILS OF CATCH BASIN 13
ADDRESS: T. I. N. 727 - 842 - 908 LOCATION: PINES, OROQUIETA CITY ADDRESS: P-6 PINES, OROQUIETA CITY, MISAMIS OCCIDENTAL BLOW UP DETAIL OF BATHROOM
PLUMBING NOTES
1. GRADES OF HORIZONTAL PIPINGS
RUN ALL HORIZONTAL PIPINGS IN PERFECTALIGNMENT AND AT A FORM GRADE NOT LESS THAN TWO PERCENT (2%)

2. CHANGE IN DIRECTION
ALL CHANGE IN DIRECTION WAS MADE BY APPROPRIATE USE OF FORTY-FIVE DEGREES (45°) WYES, LONG SWEEP QUARTER BEND, LEGEND
SIXTH-EIIGHT OR SIXTEENTH BEND. WHEN THE CHANGE OF FLOW IS FROM HORIZONTAL TO VERTICAL, A SINGLE 1/8 BEND F FAUCET
COMBINATION USED ON VERTICAL STACKS, AND SHORT QUARTER BENDS USED ON WASTE LINE, TEE AND CROSSES MAYBE USED IN CB CATCH BASIN
BENT PIPES. CV CHECK VALVE
FD FLOOR DRAIN
3. PROHIBITED FITTINGS VTR VENTILATION THROUGH ROOF
NO DOUBLE HUB OR TEE BRANCH USED ON HORIZONTAL SOIL AND WASTE LINES, THE DRILLINGS AND TAPPING OF HOUSE DRAIN,
WASTE OR VENT PIPES AND USE OF SADDLE HUB AND BEND ARE PROHIBITED. WC WATER CLOSET

4. PIPE CLEAN-OUTS LAV LAVATORY


CLEAN-OUTS ARE REQUIRED UNDER THE F0LLOWING CONDITIONS:
S SINK
a. EVERY CHANGE OF HORIZONTAL DIRECTION EXCEEDING TWENTY TWO AND ONE-HALF DEGREES (22 1/2°). ST SEPTIC TANK
b. ONE AND ONE-HALF METERS (1.50m.) INSIDE THE PROPERTY LINES BEFORE THE HOUSE DRAINAGE CONNECTION. GV GATE VALVE
c. EVERY FIFTEEN METERS (15.00m) IN HORIZONTAL RUN OF PIPES. CO CLEAN OUT
d. AT THE END OF ANY HORIZONTAL PIPE LINES. 1
2 "Ø PVC PIPE , WATER LINE
4"Ø PVC PIPE SOLID WASTE LINE
5. THE DIGESTION CHAMBER OF SEPTIC VAULT WAS WATERPROOFED.
3"Ø PVC PIPE WATER WASTE LINE
6. NOT LESS THAN 0.30 METER OF AIR SPACE WAS LEFT BETWEEN THE TOP OF THE SEWAGE AND THE UNDER PART OF VAULT ROOF 2"Ø PVC PIPE WATER WASTE LINE /
SLAB. WET VENT.

TEE
7. NO SEPTIC VAULT WAS CONSTRUCTED UNDER THE BUILDING.
WYE
8. ALL PLUMBING WORKS WAS UNDER THE SUPERVISION OF A LICENSED MASTER PLUMBER AND A LICENSED PLUMBING CONTRACTOR.
ELBOW

DESIGN CRITERIA : P-TRAP

i. LIVE LOAD_________________ 1000Pa


POLISHED STAINLESS STEEL CLEANOUT
SQUARE FRAME W/ CIRCULAR COVER
ii ALLOWABLE STRESSES
SCREW
1. CONCRETE FROM
FINISHED WATER
FOR FOOTING, BEAMS AND SLABS
FLOOR CLOSET
fc'' = 20 MPa FROM FLOOR DRAIN

2. CONCRETE MASONRY UNITS (LOAD BEARING CHB) uPVC S-1000


fm' =6.90 MPa, fm = 2.41 MPa CONNECTION VENT
45 DEG. VENT
3. REINFORCING STEEL BARS BEND
FOR BARS SMALLER THAN 16mmØ
fy = 230 MPa uPVC CLEANOUT
BEND 45 DEG BEND S 45 DEG
45 BEND

4. ASSUMED ALLOWABLE BEARING CAPACITY Y = 100KPa P-TRAP

WATER TABLE IS 1500 BELOW GROUND LEVEL.

FLOOR CLEANOUT, DRAIN, VENT, SPOT DETAIL


NOT TO SCALE

SEAL: PROFESSIONAL: PRC NO. 0012623 PROJECT NAME AND LOCATION: APPROVED AS TO PLAN AND LOCATION: SHEET CONTENTS SHEET NO.
PTR NO. 0195714
CONSTRUCTION OF TWO - STOREY PLUMBING NOTES
JUSTIN JAN M. DIGAL PLACED ISSUED OROQUIETA CITY RESIDENTIAL BUILDING ALGUER P. KHO DESIGN CRITERIA 11
MASTER PLUMBER DATE ISSUED MARCH 24, 2022 WITH ROOF DECK OWNER FLOOR CLEAN OUT, DRAIN, 13
ADDRESS: T. I. N. 727 - 842 - 908 LOCATION: PINES, OROQUIETA CITY ADDRESS: P-6 PINES, OROQUIETA CITY, MISAMIS OCCIDENTAL VENT, SPOT DETAIL
1 2 3

A CO

ACU
5
LPA 7
LPA

CO
S2 - 2WAY

1 2 3
S2

CO

E
6
LPA

1 2 3
A 1 S32WAY
LPA
B S2

CO
R

E S2 - 2WAY

3
S22WAY
REF
LPA S2 A
CO

CO
6
LPA

S2
E
S1

4.750m.
E

2
LPA WP

TERRACE
B ACU
CO

8
CO
C LPA

S2

9.500m.
CO

WP
B
CO

5
LPA

PB S2
CO

E
E S32WAY S2

WP SECOND FLOOR POWER AND LIGHTING LAYOUT

4.750m.
SCALE 1: 100M
ACU 4
CO
C LPA

3.300m. 1.825m. 2.300m.


WP
C

GROUND FLOOR POWER AND LIGHTING LAYOUT


SCALE 1: 100M

ROOF DECK POWER AND LIGHTING LAYOUT


SCALE 1: 100M

SEAL: PROFESSIONAL: PRC NO. PROJECT NAME AND LOCATION: APPROVED AS TO PLAN AND LOCATION: SHEET CONTENTS SHEET NO.
PTR NO.
CONSTRUCTION OF TWO - STOREY
PLACED ISSUED RESIDENTIAL BUILDING ALGUER P. KHO 12
POWER AND LIGHTING LAYOUT
CIVIL ENGINEER DATE ISSUED WITH ROOF DECK OWNER 13
ADDRESS: T. I. N. LOCATION: PINES, OROQUIETA CITY ADDRESS: P-6 PINES, OROQUIETA CITY, MISAMIS OCCIDENTAL
GENERAL SPECIFICATION PB1 SCHEDULE OF LOADS
ALL MATERIALS TO BE USED IN THIS PROJECT SHALL BE
OF APPROVED BRAND AND QUALITY. RATING PER NO. OF NO. & SIZES CIRCUIT
CIRCUIT NO. LOAD PH VA VOLTS AMPS. CONDUIT SIZE
OUTLET OUTLETS OF WIRE BREAKER
WIRING FOR ALL SYSTEM SHALL BE TYPE THHN OR THW
CONDUCTORS USING PVC CONDUIT PIPES, OTHER TYPES OF
1 CO 1 180VA 22 3960 230 17.22 2-3.5mm2 THHN 30A 20mm Ø PVC CONDUIT PIPE

CONDUCTORS SHALL BE AS INDICATED IN THE DRAWINGS.


2 LO 1 100VA 12 1200 230 5.22 2-2.0mm2 THHN 15A 20mm Ø PVC CONDUIT PIPE

CONDUIT SHALL BE EMBEDDED IN COLUMNS, WALLS &


TOPPINGS OF FLOOR SLABS TO ALLOW FLUSH CONNECTIONS & 3 REF 1 250VA 1 250 230 1.09 2-2.0mm2 THHN 15A 20mm Ø PVC CONDUIT PIPE

LIGHTING SYSTEM WHICH MAY BE EXPOSED BETWEEN JOINTS IN


CASE A DROP CEILING IS INSTALLED. 4 ACU 1 1.5HP 1 1399 230 6.08 2-5.5mm2 THHN 30A 20mm Ø PVC CONDUIT PIPE

SMALLEST TYPE OF CONDUCTOR TO BE USED SHALL BE 2-#3.5 5 PB2 1 - - 8258 230 35.9 2-8.0 mm2 THHN 50A 25mm Ø PVC CONDUIT PIPE
MM² TYPE THHN OR THW. WIRES SHALL BE INDICATED IN THE
DRAWINGS. - - - -
MAIN 15067 230 65.51 2-14.0 mm2 THHN 80A 25mm Ø PVC CONDUIT PIPE

WALL SWITCHES INTENDED TO CONTROL LIGHTS ON THE 230


VOLTS SYSTEM SHALL BE RATED 15 AMP. 250 VOLTS. PB2 SCHEDULE OF LOADS

LIGHT SWITCHES SHALL BE 1.35 METERS ABOVE FINISH FLOOR


LINE.
1 CO 1 180VA 22 3960 230 17.22 2-3.5mm2 THHN 30A 20mm Ø PVC CONDUIT PIPE

CONVENIENCE OUTLETS SHALL BE FLUSHED DUPLEX TYPE 2 LO 1 100VA 15 1500 230 6.52 2-2.0mm2 THHN 15A 20mm Ø PVC CONDUIT PIPE

RATED 20 AMPERES 230 VOLTS 60 Hz, AC.


3 ACU 1 1.5HP 1 1399 230 6.08 2-5.5mm2 THHN 30A 20mm Ø PVC CONDUIT PIPE

CONVENIENCE OUTLET SHALL BE 30 CM. ABOVE FINISH


FLOOR LINE. 4 ACU 1 1.5HP 1 1399 230 6.08 2-5.5mm2 THHN 30A 20mm Ø PVC CONDUIT PIPE

THE CIRCUIT BREAKER SHALL BE DRAW OUT/MOULDED CASE MAIN - - - - 8258 230 35.9 2-8.0 mm2 THHN 50A 25mm Ø PVC CONDUIT PIPE
AS REQUIRED. THE CIRCUIT BREAKERS SHALL EACH HAVE
SUFFICIENT INTERRUPTING CAPACITY & SHALL BE MANUALLY
OPERATED COMPLETES W/ TRIP DEVICES & ALL NECESSARY
ACCESSORIES TO INSURE SAFE EFFICIENT OPERATIONS.

CIRCUIT BREAKERS SHALL BE OF THE INDICATING TYPE


PROVIDING "ON" & "OFF" & "TRIP" POSITIONS OF THE
LEGEND:
OPERATING HANDLES AND SHALL EACH BE PROVIDED W/ PB PANEL BOARD
NAME PLATE FOR BRANCH CIRCUIT DESIGNATION.
1
LPA CIRCUIT HOMERUN
GENERAL ELECTRICAL INSTALLATION SHALL BE MADE TO
CONFORM TO LOCAL ORDINANCES & THE NATIONAL S32WAY TWO WAY 3 GANG SWITCH
ELECTRICAL CODE OF THE PHILIPPINES AND SHALL BE
UNDER THE SUPERVISION OF A DULY LICENSED S2 TWO GANG SWITCH
PROFESSIONAL ELECTRICAL ENGINEER.
M S1 SINGLE GANG SWITCH
PROPOSED TWO-STOREY
W/ ROOF DECK
RESIDENTIAL BUILDING
CO 3 GANG CONVENIENCE OUTLET
8° 26' 43" N
123° 48' 31" E

80AT, 2P
WP 3 GANG WEATHER PROOF OUTLET

ACU AIRCON UNIT OUTLET


30A 30A
C1 C4 REF REFRIGERATOR OUTLET
E

60AT, 2P
. FENC

YELLO
W 15A 50A R RANGE OUTLET
CONC

HOUSE RIVER
PINES
BLUE STEE
L GATE
RISER DIAGRAM C2 C5
HOUSE
CON
C. FE
NCE
E EMERGENCY LIGHT OUTLET
MIZ 15A 30A 15A
TO OZA
75mm Ø x 3W DOWNLIGHT
C3 C5 C7
ER - 350mm Ø x 20W DOWNLIGHT
ROP Y RIVER
ITY P
TO C UIETA
ORO
Q
CIT PINES PB1 15A 15A
PINES
BRIDG
E
9W OUTDOOR WALL LED LIGHT
+ 247
K1737 C6 C8
250mm SQUARE 18W LED LIGHT
PB2
700mm x 200mm x 20W LED LIGHT
ONE LINE DIAGRAM
LOCATION MAP PLAN
NOT TO SCALE

SEAL: PROFESSIONAL: PRC NO. PROJECT NAME AND LOCATION: APPROVED AS TO PLAN AND LOCATION: SHEET CONTENTS SHEET NO.
PTR NO. GENERAL SPECIFICATION
PROPOSED TWO - STOREY
PLACED ISSUED ALGUER P. KHO SCHEDULE OF LOADS
RESIDENTIAL BUILDING
ONE LINE DIAGRAM
13
ELECTRICAL ENGINEER DATE ISSUED WITH ROOF DECK OWNER
RISER DIAGRAM 13
ADDRESS: T. I. N. LOCATION: PINES, OROQUIETA CITY ADDRESS: P-6 PINES, OROQUIETA CITY, MISAMIS OCCIDENTAL LOCATION MAP