Solution:
Required strength
From Chapter 2 in Minimum Design Loads for Buildings and Other Structures (ASCE, 2006), hereafter referred to as ASCE 7,
the required strength based on the vertical loads is:
LRFD ASD
Pu = 1.2 ( 23.0 kips ) + 1.6 ( 70.0 kips ) Pa = 23.0 kips + 70.0 kips
= 140 kips = 93.0 kips
For R 0° and the special case shown for the load not in the plane of the weld group, by linear interpolation using the values in
the table for k 0:
LRFD ASD
0.75 2.00
Pu ΩPa
Dmin = Dmin =
φCC1l CC1l
140 kips 2.00 ( 93.0 kips )
= =
0.75 ( 2.95 )(1.00 ) ( 9.00 in.) 2.95 (1.00 ) ( 9.00 in.)
= 7.03 sixteenths-of-an-inch = 7.01 sixteenths-of-an-inch
For the shear strength of the Pipe wall, the minimum thickness from Table 2-3 to develop '-in. fillet welds is 0.530 in., which
exceeds the actual wall thickness, t 0.465 in. Therefore, the base metal controls.
Effective weld size
From Table 2-2, the effective weld size, Deff, is:
⎛ Fy ⎞
Deff = 30.2 ⎜ t
⎝ FE XX ⎟⎠
⎛ 35 ksi ⎞
= 30.2 ⎜ ( 0.465 in.)
⎝ 70 ksi ⎟⎠
= 7.02 sixteenths-of-an-inch