Professional Documents
Culture Documents
EC T2 Catalog 2
EC T2 Catalog 2
EC T2 Catalog 2
ECdrive T2
VIDEO
AR E AS OF A P P L I CAT I O N
PR OD UCT F E ATUR ES
Slim design with a cover height of just 100 mm for greater creative freedom
With double roller carriage and GCprofile Therm up to 140 kg leaf weight
Efficient installation thanks to pre-drilled tracks and oblong holes
Continuous floor guide available for controlled diversion of rainwater
Integrated cable guides make it easier to lay cables
Can be networked, and integrated into the building automation via open standard (BACnet)
Independent error recognition and recording
Freely configurable inputs and outputs for different functions
Integrated rechargeable battery for emergency opening and closing in the event of a power failure
Self-cleaning roller carriage reduces maintenance effort and costs
Various mechanical and electrical locks are optionally available
Service interface for simple maintenance
12 Automaticsliding door | Standard sliding door systems | ECdrive T2
D RIV E C OM P ON EN TS
6
5
4
3
2
1
1 = Transformer | 2 = Locking mechanism | 3 = Roller carriage | 4 = Control unit | 5 = Rechargeable battery | 6 = Motor
ECdrive T2 | Standard sliding door systems | Automaticsliding door 13
FITTIN G VA R IA N TS
Door fittings ECdrive T2
ISO glass fine-framed ●
MONO glass fine-framed ●
GCprofile Therm, energy-efficient profile system ●
fine-framed
Toughened safety glass clamping profile ●
All-glass system (GGS) -
Integrated all-glass system (IGG) -
Wooden leaf (on-site) ●
● = yes | - = not available
Note:
Opening widths of escape route sliding doors < 1000 mm are only permitted in exceptional cases.
A continuous floor guide is recommended for external systems from an opening width of 2000 mm.
The minimum opening widths depend on the requirements of building law.
CALCULAT ION OF LE A F A N D G L AS S D I M E N SI O N S I N MM
AL
GB
DH
GH
ÖW
AL = Drive length | DH = Passage height | GB = Glass width | GH = Glass height | ÖW = Opening width
ECdrive T2 | Standard sliding door systems | Automaticsliding door 15
Wall installation, angled floor guide, Wall installation, angled floor guide, Wall installation, continuous floor guide,
ISO glass ISO glass MONO glass
190
190 190
100
100
100
76
76
76
11
31
31
11
31
11
22 30 22 30 22 30
DH
FH
DH
FH
DH
FH
12
17
30
22
3 60
1-leaf, wall installation, ALU secondary closing edge, angled floor guide, left hand slide to open, MONO glass
AL eff.
(5) 40 ÖW+12
FW = ÖW FB = ÖW+40 12 Vrs
2-leaf, wall installation, rubber secondary closing edge, angled floor guide / adjustable floor guide, with protective leaf, ISO and MONO glass
ALeff.
(5) (5)
35 ÖW+2 35
25
(13) 2
FW= ÖW/2 FB = ÖW/2+35 FB = ÖW/2+35 FW = ÖW/2
DH = Passage height | FH = Left height | FW = Travel path | FB = Leaf width | ÖW = Opening width | Vrs = Drive extension right |
ALeff. = Effective drive length
16 Automaticsliding door | Standard sliding door systems | ECdrive T2
47.8
22
190
147
100
60
31
11
30 20 36
STH
DH
FH
17 12
Mounting within reveal, aluminium secondary closing edge, continuous floor guide, ISO and MONO glass
LB
5 AL eff. 5
STB STB
40 ÖW+2 40
TL = LB-32
2
FW = ÖW/2 FB = ÖW/2+40 FB = ÖW/2+40 FW = ÖW/2
Mounting within reveal, rubber secondary closing edge, angled / adjustable floor guide, with protective leaf, ISO and MONO glass
LB
Bls 5 5 Brs
STB STB
58
35 ÖW+2 35
TL = LB-32
4
4
LB = Clear components | STB = Side panel width | STH = Side panel height | FH = Leaf height | FB = Leaf width | FW = Travel path | ÖW = Opening width |
DH = Passage height | TL = Lintel length | Bls = Fastening left | Brs = Fastening right | ALeff. = Effective drive length
ECdrive T2 | Standard sliding door systems | Automaticsliding door 17
190 37.9
100
36
STH
FH
DH
17
2-leaf, wall mounting, rubber secondary closing edge, angled floor guide / adjustable floor guide, with protective leaf
Bls LB Brs
(5) ALeff.
25 25
STB STB (5)
35 ÖW+2 35
TL = AL-22
FW = ÖW/2
FB = ÖW/2+35 FB = ÖW/2+35 FW= ÖW/2
LB = Clear components | STB = Side panel width | STH = Side panel height | FH = Leaf height | FB = Leaf width | FW = Travel path | ÖW = Opening width |
DH = Passage height | Bls = Fastening left | Brs = Fastening right | ALeff. = Effective drive length
18 Automaticsliding door | Standard sliding door systems | ECdrive T2
190
100
76
31
11
17
FH
DH
1-leaf, wall installation, plastic secondary closing edge, adjustable angled floor guide, left hand slide to open
AL eff.
35 ÖW+6
(5) 25
FW = ÖW FB = ÖW+35 6 Vrs
2-leaf, wall installation, rubber secondary closing edge, adjustable floor guide with protective leaf
AL eff.
35 ÖW+4 35
25 25
5 5
4
FW=ÖW/2 FB=ÖW/2+35 FB=ÖW/2+35 FW=ÖW/2
FW = Travel path | FB = Leaf width | ÖW = Opening width | Vrs = Drive extension right | DH = Passage height | FH = Lead height |
ALeff = Effective drive extension
ECdrive T2 | Standard sliding door systems | Automaticsliding door 19
47.8
190
30
147
100
60
31
7
FH=DH
DH
17
LB
ALeff.
STB = LB-(ÖW+4)-10 STB = LB-(ÖW+4)-10
2 ÖW+4 2
(5) (5)
37.5 58 58 37.5
TL=LB-32
35 4 35
FW=ÖW/2 FB=ÖW/2+35 FB=ÖW/2+35 FW=ÖW/2
LB
STB = LB-(ÖW+4)-10 STB = LB-(ÖW+4)-10
Bls 2 ÖW+4 2 Brs
(5) (5)
35 35
TL=LB-32
5
5
5
4 5
ALeff.
LB = Clear components | STB = Side panel width | FH = Leaf height | FB = Leaf width | FW = Travel path | ÖW = Opening width | DH = Passage height |
TL = Lintel length | Bls = Fastening left | Brs = Fastening right | ALeff. = Effective drive length
20 Automaticsliding door | Standard sliding door systems | ECdrive T2
Wall installation, continuous floor guide Wall installation, angled floor guide
190 190
Ø9
Ø9
100
100
76
76
31
12 40 31 12 40
FH
DH
DH
FH
50 ÖW
FW = ÖW FB
AL eff.
50 ÖW 50
(5) (5)
FW = ÖW/2 FB FB FW = ÖW/2
FH = Leaf height | FB = Leaf width | FW = Travel path | ÖW = Opening width | DH = Passage height | ALeff. = Effective drive length
ECdrive T2 | Standard sliding door systems | Automaticsliding door 21
190 190
32 32
Ø9
100
100
76
76
60
60
31
10
40 ( DH )
( DH )
40
DH
FH
DH
STH
STB Li ÖW STB Re
10 10
6
50 50
FW = ÖW/2 FB FB FW= ÖW/2
LBW
LBW
STB Li ÖW STB Re
10 10
6
50 50
FW= ÖW/2 FB FB FW= ÖW/2
LBW = Clear installation width | STB Li = Side panel width left | STB Re = Side panel width right | FW = Travel path | FB = Leaf width | ÖW = Opening width |
DH = Passage height
22 Automaticsliding door | Standard sliding door systems | ECdrive T2
WITH IS O/ M ON O G L AS S F I TT I N G – W I T H S I DE PAN EL –
PART IT ION WALL I N STA LL AT I O N
190 190
32
min.10
max.20
32
145
145
100
100
60
15
LBH
LBH
STH
40
FH = DH+3
DH
40
DH
STB Li ÖW STB Re
10 10
6
52
50 50
FW= ÖW/2 FB FB FW = ÖW/2
LBW
LBW = Clear installation width | LBH = Clear installation height | STH = Side panel height | STB Li = Side panel width left | STB Re = Side panel width right |
FW = Travel path | FB = Leaf width | FH = Leaf height | ÖW = Opening width | DH = Passage height
ECdrive T2 | Standard sliding door systems | Automaticsliding door 23
min.10
max.20
H OL
H OL
190
190 32
32
145
145
100
100
15
10
LBH
LBH
STH
DH
40 40
FH
DH
7
Horizontal section
HOL = High fanlight | LBW = Clear installation width | LBH = Clear installation height | STH = Side panel height | STB Li = side panel width left |
STB Re = side panel width right | FW = Travel path | FB = Leaf width | FH = Leaf height | ÖW = Opening width | DH = Passage height