COMMERCIAL IN CONFIDENCE

SHT
SHEET TITLE No.
SHEET REVISION MODIFICATION RECORD
ISSUE RECORD IR 1 2 SHT SHT DETAILS OF MODIFICATION
APPROVAL
No. REV. & DATE
A A
ALL 1 FIRST ISSUE 20-05-10
P.B.

AS PER
MODIFIED 14-06-10
ISSUE 2 F.C.

B B

CONTROL NETWORK-ETHERNET N10 1 1

IJS JOYSTICK NETWORK-ETHERNET N12 1 2

UPS DISTRIBUTION - SUPPLIES AND ALARMS P01 1 1

UPS1 POWER DISTRIBUTION P11 1 1


UPS2 POWER DISTRIBUTION P21 1 1
UPS3 POWER DISTRIBUTION P31 1 1
C ANEMOMETER HEATER SUPPLY BISTRIBUTION OPTION P41 1 1 C

SERIAL LINKS SIAa DP SENSORS & PME S15 1 1


SERIAL LINKS SIAb DP SENSORS & PME S16 1 2
SERIAL LINKS S1Ba DP SENSORS & PME (duplex version) S17 1 2
IJS SERIAL LINKS SIAa & SIAb S18 1 1

GYRO 1 (TSS Meridian Standard) INTERFACE ONLY S21 1 1

GYRO 2 (TSS Meridian Standard) INTERFACE ONLY S22 1 1


GYRO 3 (TSS Meridian Standard) INTERFACE ONLY S23 1 1

ANEMOMETER 1 (GILL Windobserver 11) S31 1 1


D ANEMOMETER 2 (GILL Windobserver 11) OPTION S32 1 1 D
ANEMOMETER 3 (GILL Windobserver 11) S33 1 1

VERIPOS LiD2 SERIES DGPS1 S41 1 1


VERIPOS LiD3 SERIES DGPS2 S42 1 1

CYSCAN 1 S50 1 1

VOYAGE DATA RECORDER S50 1


TUNNEL THRUSTER INTERFACE T01 2
AZIMUTH THRUSTER INTERFACE T02 1 2
SWITCHBOARD THRUSTER INTERFACE T03 1 1
E E

DRAWING ISSUE A B C D E F G H J K L MN P R S
20-05-10

14-06-10
DATE

F.CORDERO
P.BIGGS

TITLE:
F F
INITIALS

TYPICAL CLASS 2 DP SYSTEM


CABLE INTERCONNECTION DIAGRAMS
ISSUE RECORD SHEET
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam UK Ltd. DRG. No. IR SHEET: DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 2
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

DP DP
CONTROLLER CONTROLLER
CC01 CC02
A A
NETWORK SWITCH A NETWORK SWITCH A
PORT 5 N10-01 PORT 5
SEE NOTE 4

NETWORK SWITCH B NETWORK SWITCH B


PORT 5 N10-02 PORT 5
SEE NOTE 5

B DP B
WORKSTATION
DP WS01
WORKSTATION NETWORK SWITCH B TB21/
N10-06
WS01 PORT 7 ECM2
NETWORK SWITCH A TB21
PORT 7 N10-03 ECM1 SEE NOTE 5

SEE NOTE 4

DP
WORKSTATION
C
DP WS02 C
WORKSTATION NETWORK SWITCH B TB21/
N10-07
WS02 PORT 6 ECM2
NETWORK SWITCH A TB21
PORT 6
N10-04 ECM1 SEE NOTE 5

SEE NOTE 4

IJS
CONTROLLER
TEMPORARY FOR CC04
NETWORK SWITCH A COMMISSIONING ONLY NETWORK SWITCH A
PORT 8
N10-08 PORT 8
D D
SEE NOTE 4

LENGTH OF CABLE
NETWORK SWITCH A TO BE 5 METRE MIN MAINTENANCE
PORT 8
N10-05 LAPTOP
SEE NOTE 4

E E

TYPE 1 TYPE 2

HARTING LAPTOP
HARTING HARTING
CONNECTOR ETHERNET PORT
CONNECTOR CONNECTOR
YELLOW 1 1 YELLOW (TX+) YELLOW 1 1 YELLOW (TX+)
PAIR 1 PAIR 1
ORANGE 2 2 ORANGE (TX-) ORANGE 2 2 ORANGE (TX-)
WHITE 3 3 WHITE (RX+) WHITE 3 3 WHITE (RX+)
PAIR 2 PAIR 2
BLUE 6 6 BLUE (RX-) BLUE 6 6 BLUE (RX-)
SCN 5 S SCN SCN 5 S SCN

TITLE:
F TYPE : 2TW PAIR NETWORK TYPE : 2TW PAIR NETWORK
TYPICAL CLASS 2 DP SYSTEM F
VOLTS : LOW VOLTS : LOW
100 BASE-T 100 BASE-T CABLE INTERCONNECTION DIAGRAM
AMPS : LOW AMPS : LOW
EMC LEVEL : A EMC LEVEL : A CONTROL NETWORK - ETHERNET
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam Ltd. Rugby England - ALLAN PTASZYNSKI PAUL BIGGS -
any other person nor copied in whole or part except with the prior written consent of Converteam Ltd. DRG. No. SHEET:N10 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

IJS
CONTROLLER
CC04
A A
IJS
NETWORK SWITCH C N12-01
PORT 2 FIXED JOYSTICK
TB13 TB JS11
1 1
2 2
N12-02
TYPE: P-MULTICORE
VOLTS: 24V AC
AMPS: 1A
EMC LEVEL: B

B IJS B
NETWORK SWITCH C N12-03
PORT 3
JOP
DOCKING STATION
TB13 PL6 DS01
3 3
4 2
N12-04
TYPE: P-MULTICORE
VOLTS: 24V AC
AMPS: 1A
EMC LEVEL: B

C IJS C
NETWORK SWITCH C N12-05
PORT 4
JOP
DOCKING STATION
TB13 PL6 DS02
5 3
6 2
N12-06
TYPE: P-MULTICORE
VOLTS: 24V AC
AMPS: 1A
EMC LEVEL: B

D
IJS D

NETWORK SWITCH C N12-07 DOCKING STATION


PORT 5
JOP DS03
TB13 PL6

7 3
8 2
N12-08
TYPE: P-MULTICORE
VOLTS: 24V AC
AMPS: 1A
EMC LEVEL: B

E E

TYPE 1

HARTING HARTING
CONNECTOR CONNECTOR
YELLOW 1 1 YELLOW (TX+)
PAIR 1
ORANGE 2 2 ORANGE (TX-)
WHITE 3 3 WHITE (RX+)
PAIR 2
BLUE 6 6 BLUE (RX-)
SCN 5 S SCN

TITLE:
F TYPE : 2TW PAIR NETWORK
TYPICAL CLASS 2 DP SYSTEM F
VOLTS : LOW
100 BASE-T IJS JOYSTICK NETWORK - ETHERNET
AMPS : LOW
EMC LEVEL : A CABLE INTERCONNECTION DIAGRAM
REMARK : NO COLOURED SLEEVING CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam UK Ltd. DRG. No. SHEET:N12 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 2
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

UPS UPS UPS


DISTRIBUTION DISTRIBUTION DISTRIBUTION
A BOARD BOARD BOARD A
UPS1 UPS2 UPS3

B B
VESSEL VESSEL VESSEL
SUPPLY SUPPLY SUPPLY
230V AC 230V AC 220V AC
50HZ P01-01 20A INPUT MCB 50HZ P01-03 20A INPUT MCB 60HZ P01-05 20A INPUT MCB
1PH 1PH 1PH

C C

D D

DP DP IJS
CONTROLLER CONTROLLER CONTROLLER
CC01 CC02 CC04
P01-02 P01-04 P01-06

E E

F TITLE: F
TYPICAL CLASS 2 DP SYSTEM
UPS DISTRIBUTION - SUPPLIES AND ALARMS
CABLE INTERCONNECTION DIAGRAM
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam UK Ltd. DRG. No. SHEET:P01 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

UPS UPS
DISTRIBUTION DISTRIBUTION
BOARD BOARD MCB 6 TB
MCB 1 ISOLATOR 1 DP
A UPS1 1 1 (L) CONTROLLER 1
UPS1 1 L
CYSCAN A
2 3 (N) 2 N
CC 01
P11-01 P11-09
TYPE: P-MULTICORE TYPE: P-MULTICORE
VOLTS: 230V AC VOLTS: 230V AC
AMPS: 1A AMPS: 4A
EMC LEVEL: C EMC LEVEL: C

E16

TB POWER LEAD
MCB 2 TB L1 L1
1 L1 N1 N1 TB POWER LEAD
2 N1 DGPS1 E1 E1 DGPS1
B MCB 7 TB L L B
P11-02 LOCAL J/BOX P11-03 1 L N N
TYPE: P-MULTICORE (SHIPYARD SUPPLY) 2 N E E GYRO 1
VOLTS: 230V AC JUNCTION BOX
AMPS: 2A P11-10 P11-11
EMC LEVEL: C TYPE: P-MULTICORE (SHIPYARD SUPPLY)
TB POWER LEAD VOLTS: 230V AC
MCB3 TB L2 L1 AMPS: <1A
1 L2 N2 N1 EMC LEVEL: C
E16
2 N2 E1 E1 DGPS1
P11-04 P11-05 MONITOR
TYPE: P-MULTICORE
VOLTS: 230V AC
AMPS: 2A
EMC LEVEL: C

C C
MCB 8 ISOLATOR 2 DP
E16 1 1 (L) CONTROLLER 2
2 3 (N) CC 01
P11-12
TYPE: P-MULTICORE
VOLTS: 230V AC
AMPS: 1A
EMC LEVEL: C

E16

MCB 4 ISOLATOR DP
1 1 (L) WORKSTATION 1
2 3 (N) WS 01
D P11-06 D
TYPE: P-MULTICORE
VOLTS: 230V AC
AMPS: 1A
EMC LEVEL: C

E16

IEC
TB POWER LEAD
MCB 5 TB L L
1 L N N
2 N SOCKET/ E E DP ALARM & EVENT
P11-07 JUNCTION BOX P11-08 PRINTER
PR01
CAD FILE = J:\MARINE\TENDERS\TG12900\TG12945\DPS21 DUPLEX DP+IJS\ESDI-1R46240-SHP11.DWG

TYPE: P-MULTICORE (SHIPYARD SUPPLY)


E VOLTS: 230V AC E
AMPS: <1A
EMC LEVEL: C
E16

TITLE:
F TYPICAL CLASS 2 DP SYSTEM F
CABLE INTERCONNECTION DIAGRAM
UPS 1 DISTRIBUTION
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England - ALLAN PTASZYNSKI PAUL BIGGS -
any other person nor copied in whole or part except with the prior written consent of Converteam Ltd.
UK Ltd. DRG. No. SHEET:P11 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

UPS
DISTRIBUTION
BOARD
MCB 1 ISOLATOR 1 DP
A UPS-2 1 1 (L) CONTROLLER 2 A
2 3 (N) CC 02
P21-01
TYPE: P-MULTICORE
VOLTS: 230V AC
AMPS: 1A
EMC LEVEL: C

E16

B MCB 2 ISOLATOR DP B
1 1 (L) WORKSTATION 2
2 3 (N) WS 02
P21-02
TYPE: P-MULTICORE
VOLTS: 230V AC
AMPS: 1A
EMC LEVEL: C

E16

C TB POWER LEAD C
MCB 3 TB L2 L2
1 L N2 N2
2 N E2 E2
J/BOX
P21-03 P21-04 GYRO 2
(SHIPYARD SUPPLY)
TYPE: P-MULTICORE
VOLTS: 230V AC
AMPS: <1A
EMC LEVEL: C
E16

D D
TB POWER LEAD
MCB 5 TB L L
1 L N N
2 N SOCKET/ E E DP ALARM & EVENT
P21-05 JUNCTION BOX P21-06 PRINTER
TYPE: P-MULTICORE (SHIPYARD SUPPLY) PR02
VOLTS: 230V AC
AMPS: <1A
EMC LEVEL: C
E16

E E

MCB 6 ISOLATOR 2 DP
1 1 (L) CONTROLLER 1
2 3 (N) CC 01
P21-07
TYPE: P-MULTICORE
VOLTS: 230V AC
AMPS: 1A
EMC LEVEL: C

E16

TITLE:
F TYPICAL CLASS 2 DP SYSTEM F
UPS 2 DISTRIBUTION
CABLE INTERCONNECTION DIAGRAM
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam Ltd.
UK Ltd. DRG. No. SHEET:P21 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

UPS
DISTRIBUTION
BOARD
MCB 1 ISOLATOR 1 IJS
A UPS-3 1 1 (L) CONTROLLER A
2 3 (N) CC 03
P31-01
TYPE: P-MULTICORE
VOLTS: 230V AC
AMPS: 1A
EMC LEVEL: C

E16

TB POWER LEAD
B MCB 2 TB L2 L2 B
1 L N2 N2
2 N E2 E2
J/BOX
P31-02 P31-03 GYRO 3
(SHIPYARD SUPPLY)
TYPE: P-MULTICORE
VOLTS: 230V AC
AMPS: <1A
EMC LEVEL: C
E16

C C

D D

E E

TITLE:
F TYPICAL CLASS 2 DP SYSTEM F
UPS 3 DISTRIBUTION
CABLE INTERCONNECTION DIAGRAM
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam Ltd.
UK Ltd. DRG. No. SHEET:P31 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

A A

VESSEL SUPPLY . TB GENERAL


230V AC . L PURPOSE
. N
50Hz 1 PH 5A PSU GP01
P41-01
TYPE: P-MULTICORE
(FOR ANEMOMETER 1
VOLTS: 230V AC HEATING
AMPS: 2A SEE SHT. S31)
EMC LEVEL: C
B B

E16

VESSEL SUPPLY . TB GENERAL


C C
230V AC . L PURPOSE
. N
50Hz 1 PH 5A PSU GP02
P41-02
TYPE: P-MULTICORE
(FOR ANEMOMETER 2
VOLTS: 230V AC HEATING
AMPS: 2A SEE SHT. S32)
EMC LEVEL: C

E16

D D

VESSEL SUPPLY . TB GENERAL


230V AC . L PURPOSE
. N
50Hz 1 PH 5A PSU GP03
P41-03
TYPE: P-MULTICORE
(FOR ANEMOMETER 3
VOLTS: 230V AC HEATING
AMPS: 2A SEE SHT. S33)
EMC LEVEL: C

E E
E16

TITLE:
F TYPICAL LASS 2 DP SYSTEM F
ANEMOMETER HEATER SUPPLY DISTRIBUTION
CABLE INTERCONNECTION DIAGRAM
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam Ltd.
UK Ltd. DRG. No. SHEET:P41 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE LOCAL


TB13 JB LOCAL JB
+24V 1 6
0V 2 5
(SHIPYARD
SUPPLY)
DP CONTROLLER DP CONTROLLER
CC02 CC01 S15-115
A A
SIAa SIAa

TB1 TB1 GYROCOMPASS 1


S15-101
SEE SHT. S21

LOCAL FLYING LEAD WITH


JB 25 WAY D TYPE PLUG
1 WHITE (TX+ PIN2)
PAIR 1
2 RED (TX- PIN14)
TB2 TB2 ANEMOMETER 1 MAE99-04 LOCAL 3 WHITE (RX+ PIN3)
S15-102 TB3 JB (RX- PIN16)
PAIR 2
SEE SHT. S31 4 PINK
(TXA) 1 3 5 WHITE (0V PIN15)
PAIR 1 PAIR 5
(TXB) 2 4 6 BLACK (+24V PIN9)
B PAIR 2
(RXA) 4 1 7 GREEN/YELLOW (OAS - PIN1) B
(RXB) 5 2
(OAS) EARTHBAR 7
VRU 1
TB3 TB3
S15-103 S15-115 TSS
TYPE: 10 WAY DMS RP-30
TYPE: 2TW PAIR OAS FLYING LEAD
VOLTS: RS422 VOLTS: RS422
AMPS: LOW AMPS: LOW
EMC LEVEL: A EMC LEVEL: A
E10
REMARKS: CABLE 5M LENGTH.
TB4 TB4 DGPS1 PAIRS 3 AND 4 NOT USED
S15-104 NOT TERMINATED AND
SEE SHT. S41
MUST BE INSULATED
FROM EARTH.
SENSOR HOUSING
MUST BE INSULATED
FROM EARTH.
C TB5 TB5 C
TIME SYNC TIME SYNC

TB6 TB6 CYSCAN


S15-105
SEE SHT. S50

TB7 TB7 SPARE


S15-106
D 37 WAY 'D' TYPE PLUG TB8 D
PIN 24 1 (TXA)
PAIR 1
PIN 6 2 (TXB)
PIN 19 3 (0V)
PAIR 2
not conn 3 (0V)
DP ALARM
TB8 TB8
PRINTER S15-104 S15-107
(PR01)
TYPE: SL 2TW PAIR OAS
VOLTS: RS422
AMPS: LOW MAE MAE
EMC LEVEL: A 99-04 99-04

E E

TERMINATION TYPE TYPE 1


INTERNAL LINK

MAE 99-04 MAE 99-04 TB4 TB5


(TXA) 1 6 (TXA) (TXA) 1 1 (TXA)
PAIR 1 (TXB) 2 7 (TXB) PAIR 1(TXB) 2 2 (TXB)
(0V) 3 8 (0V) (0V) 3 3 (0V)
PAIR 2 (0V) 3 8 (0V) PAIR 2 (0V) 3 3 (0V)
(RXA) 4 9 (RXA) (RXA) 4 4 (RXA)
PAIR 3 (RXB) 5 10 (RXB) PAIR 3 (RXB) 5 5 (RXB)
NOT CONN. EARTH BAR (OAS) (OAS) EARTH BAR EARTH BAR

F TYPE : SL 3TW PAIR OAS TYPE : SL 3TW PAIR OAS TITLE: F


VOLTS : LOW VOLTS : LOW TYPICAL CLASS 2 DP SYSTEM
AMPS : RS422 AMPS : RS422 CONNECTION DIAGRAM-SERIAL LINKS (SIAa)
EMC LEVEL : A EMC LEVEL : A DP SENSORS AND PME
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam UK Ltd. DRG. No. SHEET:S15 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE LOCAL


TB13 JB LOCAL JB
+24V 1 6
0V 2 5
(SHIPYARD
SUPPLY)
DP CONTROLLER DP CONTROLLER
CC01 CC02 S16-115
A A
SIAb SIAb

TB1 TB1 GYROCOMPASS 2


S16-105
SEE SHT. S22

LOCAL FLYING LEAD WITH


JB 25 WAY D TYPE PLUG
1 WHITE (TX+ PIN2)
PAIR 1
2 RED (TX- PIN14)
TB2 TB2 ANEMOMETER 2 MAE99-04 LOCAL 3 WHITE (RX+ PIN3)
S16-106 TB3 JB (RX- PIN16)
PAIR 2
SEE SHT. S32 4 PINK
(TXA) 1 3 5 WHITE (0V PIN15)
PAIR 1 PAIR 5
(TXB) 2 4 6 BLACK (+24V PIN9)
B PAIR 2
(RXA) 4 1 7 GREEN/YELLOW (OAS - PIN1) B
(RXB) 5 2
(OAS) EARTHBAR 7
VRU 2
TB3 TB3
S16-107 S16-115 TSS
TYPE: 10 WAY DMS RP-30
TYPE: 2TW PAIR OAS FLYING LEAD
VOLTS: RS422 VOLTS: RS422
AMPS: LOW AMPS: LOW
EMC LEVEL: A EMC LEVEL: A
E10
REMARKS: CABLE 5M LENGTH.
TB4 TB4 DGPS2 PAIRS 3 AND 4 NOT USED
S16-108 NOT TERMINATED AND
SEE SHT. S42
MUST BE INSULATED
FROM EARTH.
SENSOR HOUSING
MUST BE INSULATED
FROM EARTH.
C TB5 VOYAGE DATA RECORDER TB5 VOYAGE DATA RECORDER C
SEE SHT. S60 SEE SHT. S60

TB6 TB6
S16-110

TB7 TB7
S16-111
D 37 WAY 'D' TYPE PLUG TB8 D
PIN 24 1 (TXA)
PAIR 1
PIN 6 2 (TXB)
PIN 19 3 (0V)
PAIR 2
not conn 3 (0V)
DP ALARM
TB8 TB8
PRINTER S16-104 S16-112
(PR02)
TYPE: SL 2TW PAIR OAS
VOLTS: RS422
AMPS: LOW MAE MAE
EMC LEVEL: A 99-04 99-04

E E

TERMINATION TYPE TYPE 1

MAE 99-04 MAE 99-04


(TXA) 1 6 (TXA)
PAIR 1
(TXB) 2 7 (TXB)
(0V) 3 8 (0V)
PAIR 2
(0V) 3 8 (0V)
(RXA) 4 9 (RXA)
PAIR 3 (RXB) 5 10 (RXB)
NOT CONN. EARTH BAR (OAS)

F TYPE : SL 3TW PAIR OAS TITLE: F


VOLTS : LOW TYPICAL CLASS 2 DP SYSTEM
AMPS : RS422 CONNECTION DIAGRAM-SERIAL LINKS (SIAb)
EMC LEVEL : A DP SENSORS AND PME
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam UK Ltd. DRG. No. SHEET:S16 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 2
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE LOCAL


TB13 JB LOCAL JB
+24V 3 6
0V 4 5
(SHIPYARD
SUPPLY)
DP CONTROLLER DP CONTROLLER
CC02 CC01 S17-115
A A
SIBa SIBa

TB1 TB1 GYROCOMPASS 3


S17-108
SEE SHT. S23

LOCAL FLYING LEAD WITH


JB 25 WAY D TYPE PLUG
1 WHITE (TX+ PIN2)
PAIR 1
2 RED (TX- PIN14)
TB2 TB2 ANEMOMETER 3 MAE99-04 LOCAL 3 WHITE (RX+ PIN3)
S17-109 TB3 JB (RX- PIN16)
PAIR 2
SEE SHT. S33 4 PINK
(TXA) 1 3 5 WHITE (0V PIN15)
PAIR 1 PAIR 5
(TXB) 2 4 6 BLACK (+24V PIN9)
B PAIR 2
(RXA) 4 1 7 GREEN/YELLOW (OAS - PIN1) B
(RXB) 5 2
(OAS) EARTHBAR 7
VRU 3
TB3 TB3
S17-110 S17-115 TSS
TYPE: 10 WAY DMS RP-30
TYPE: 2TW PAIR OAS FLYING LEAD
VOLTS: RS422 VOLTS: RS422
AMPS: LOW AMPS: LOW
EMC LEVEL: A EMC LEVEL: A
E10
REMARKS: CABLE 5M LENGTH.
TB4 TB4 PAIRS 3 AND 4 NOT USED
S17-111 NOT TERMINATED AND
MUST BE INSULATED
FROM EARTH.
SENSOR HOUSING
MUST BE INSULATED
FROM EARTH.
C TB5 TB5 C
S17-112

TB6 TB6
S17-113

TB7 TB7
S17-114
D D

TB8 TB8
S17-115

MAE MAE
99-04 99-04

E E

TERMINATION TYPE TYPE 1


NOTE : K2 ADE CONVERTER SWITCH SETTING
SW1 - OFF
MAE 99-04 MAE 99-04 SW2 - OFF
(TXA) 1 6 (TXA) SW3 - OFF
PAIR 1
(TXB) 2 7 (TXB) SW4 - ON
(0V) 3 8 (0V)
PAIR 2
(0V) 3 8 (0V)
SW5 - OFF
(RXA) 4 9 (RXA) SW6 - ON
PAIR 3 (RXB) 5 10 (RXB)
NOT CONN. EARTH BAR (OAS)

F TYPE : SL 3TW PAIR OAS TITLE:


F
VOLTS : LOW TYPICAL CLASS 2 DP SYSTEM
AMPS : RS422 CONNECTION DIAGRAM-SERIAL LINKS (SIBa)
EMC LEVEL : A DP SENSORS AND PME
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam UK Ltd. DRG. No. SHEET:S17 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 2
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

IJS CONTROLLER
CC04
A A
SIAa

TB1 GYRO 1
SEE SHT. S21

DP CONTROLLER
TB2 GYRO 2
CC01
SEE SHT. S22

B B
CONV 1

TB3 IPC1
S18-103

CONV 2

TB4 IPC2
S18-104

CONV 1
C TB5 IPC1
C
S18-103

CONV 2

TB6 IPC2
S18-104

TB7
DP CONTROLLER
D CC02 D

TB8

MAE
99-04

E E

TERMINATION TYPE TYPE 1

PHOENIX
CONVERTER
MAE 99-04 TERMINALS
(RXB) 5 T(B)
PAIR 1
(RXA) 4 T(A)
(0V) 3 GND
PAIR 2 (0V) 3 GND
(TXB) 2 D(B)
PAIR 3 (TXA) 1 D(A)
EARTH BAR (OAS) GND

F TYPE : SL 3TW PAIR OAS TITLE:


F
VOLTS : LOW TYPICAL CLASS 2 DP SYSTEM
AMPS : RS422 IJS SERIAL LINKS (SIAa )
EMC LEVEL : A CABLE INTERCONNECTION DIAGRAM
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam UK Ltd. DRG. No. SHEET:S18 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

MAE 99-04
TB1 .
(RXA) 4 . (TXA)
GYROCOMPASS
PAIR 1
(RXB) 5 . (TXB) 1
A PAIR 2 (0V) 3 . (COMMON) A
(0V) 3 . (COMMON)
(OAS) EARTH BAR GROUND
TO SHT.S15 POST
CC01
S21-104 LINK
CC01-SIAa
TYPE: SL 2 TW PAIR OAS
VOLTS: RS422
AMPS: LOW
EMC LEVEL: A

MAE 99-04
TB1 .

PAIR 1 (RXA) 4 . (TXA)


(RXB) 5 . (TXB)
B PAIR 2 (0V) 3 . (COMMON) B
(0V) 3 . (COMMON)
(OAS) EARTH BAR GROUND
TO SHT.18 POST
IJS
S21-105 LINK
CC03-SIAa
TYPE: SL 2 TW PAIR OAS
VOLTS: RS422
AMPS: LOW
EMC LEVEL: A

C C

D D

(SHIPYARD
E E
SUPPLY)

E6

TITLE:
F TYPICAL CLASS 2 DP SYSTEM F
GYROCOMPASS 1
CABLE INTERCONNECTION DIAGRAM
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam Ltd.
UK Ltd. DRG. No. SHEET:S21 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

MAE 99-04
TB1 .
(RXA) 4 .
GYROCOMPASS
PAIR 1
(RXB) 5 . 2
A PAIR 2 (0V) 3 . A
(0V) 3 .
(OAS) EARTH BAR GROUND
TO SHT.S16 POST
CC02
S22-104 LINK
CC02-SIAb
TYPE: SL 2 TW PAIR OAS
VOLTS: RS422
AMPS: LOW
EMC LEVEL: A

MAE 99-04
TB2 .
(RXA) 4 . (TXA)
PAIR 1
(RXB) 5 . (TXB)
B PAIR 2 (0V) 3 . (COMMON) B
(0V) 3 . (COMMON)
(OAS) EARTH BAR GROUND
TO SHT.18 POST
IJS
S22-105 LINK
CC04-SIAa
TYPE: SL 2 TW PAIR OAS
VOLTS: RS422
AMPS: LOW
EMC LEVEL: A

C C

D D

(SHIPYARD
E E
SUPPLY)

E6

F TITLE: F
TYPICAL CLASS 2 DP SYSTEM
GYROCOMPASS 2
CABLE INTERCONNECTION DIAGRAM
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam Ltd.
UK Ltd. DRG. No. SHEET:S22 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

GYROCOMPASS
3
A A

MAE 99-04
TB1 .
(RXA) 4 . (TXA)
PAIR 1
(RXB) 5 . (TXB)
B PAIR 2 (0V) 3 . (COMMON) B
(0V) 3 . (COMMON)
(OAS) EARTH BAR GROUND
TO SHT.17 POST
CC02
S23-105 LINK
CC02-SIBa
TYPE: SL 2 TW PAIR OAS
VOLTS: RS422
AMPS: LOW
EMC LEVEL: A

C C

D D

(SHIPYARD
E E
SUPPLY)

E6

F TITLE: F
TYPICAL CLASS 2 DP SYSTEM
GYROCOMPASS 3
CABLE INTERCONNECTION DIAGRAM
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam Ltd.
UK Ltd. DRG. No. SHEET:S23 DRAWING
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx 1
*TY

Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing CONT'D: - REVISION:

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

NOTE:
THIS PAIR BROUGHT INTO LIGHTNING
A PROTECTION UNIT AND EARTHED (FOR A
REPROGRAMMING ANEMOMETER IF REQUIRED)
ANY SPARE CORES TO BE KEPT WELL AWAY
MAE 99-04 FROM CLEAN CONNECTIONS.
SIAa TB2 LIGHTNING BARRIER

(RXA-) 4 4
PAIR 1 ESP15D
CLEAN LIGHTNING BARRIER LOCAL JB
(RXB+) 5 3
2 1 (TXB+) LOCAL
ESP15D PAIR 1
( 0v) 3 4 JB FLYING LEAD
LINE
PAIR 2 ESP15D 1 3 (TXA-)
CLEAN 1 Green (TXB+)
( 0v) 3 3 S 4 (RXB+) 2 Ind.scn PAIR 1
PAIR 2
3 Black (TXA-)
LIGHTNING BARRIER S 6 (RXA-) LOCAL JB
Overall scn overall screen
not connected &
ESP30E
SHIPYARD 4 White (RXB+) ANEMOMETER 1
LINE 2 7 (+24Vdc) PAIR 2
insulated from earth 5 Ind.scn Gill
PAIR 3 SUPPLY 6 Black (RXA-)
Any unused screens or
console earth bar drain wires to be insulated 1 9 (0Vdc)
7 Red (+24Vdc)
Windobserver II
from each other and earth 2 10 (RS422 0v)
B 8 Ind.scn PAIR 3 B
PAIR 4
ESP15D 9 Black (0Vdc)
LINE
1 12 (0Vdc)
10 Blue (RS422 0v)
with heater
S 2 Overall scn 11 Ind.scn PAIR 4 1390 pk 007

ESP50H ESP15D ESP30E ESP15D


ESP15D ESP30E ESP15D ESP50H
1

CLEAN CLEAN CLEAN CLEAN


12 Black (0Vdc)

2
4 S 3

LINE
Any unused screens 2

S
LINK 2 TO 5 TO 8 TO 11 13 Yellow (Heater +)
or drain wires to be 3
PAIR 5

1
connected to ESP15D 4 14 Ind.scn
'S' terminal 5 15 Black (Heater -)

2
TO SHT.S15

4 S 3

LINE
6

S
S31-101 S31-102 7 S31-103
CC01-TB2 NOTE:

1
TYPE: 3 TW PAIR OAS TYPE: 4 TW PAIR OAS 8 TYPE: 9 PAIR FLYING LEAD
VOLTS: 24V DC ON EARTH CONNECTION
VOLTS: 24V DC 9 ATTACHED TO

2
BETWEEN ANEMOMETER

4 S 3

LINE
AMPS: LOW LIGHTNING AMPS: LOW 10 ANEMOMETER

S
EMC LEVEL: A BARRIER TB MOUNTING BOLT AND
EMC LEVEL: A 11 VOLTS: RS422
MAST BOLT, ENSURE

1
NOTE: THIS CABLE AND ANY 1 13 12 AMPS: LOW
ESP50H GOOD CONNECTIONS
SPARE CORES,TO BE LINE 2 15 13 EMC LEVEL: A

1 S 2
4 S 3
WITH ANTI-CORROSIVE

LINE
KEPT WELL AWAY FROM 14 NOTE: CABLE 1.5M LENGTH.
S31-104 PROPERTIES.
THE LINE SIDE ANEMOMETER 15 ALL UNUSED PAIRS
C CONNECTIONS
TYPE: MULTICORE
MUST BE INSULATED
C
VOLTS: 24V DC
AMPS: 3A FROM EARTH AND
EACH OTHER
EMC LEVEL: B

Bridge Mast Mast


LIGHTNING
DP TB13 BARRIER
CONTROLLER (+24Vdc) 5 4
ESP30E E6 E6
CC01 PAIR 3
CLEAN E16 Max length 1m
(0Vdc) 6 3

TYPE: PART OF ABOVE TWISTED PAIRS CABLE

LIGHTNING
D BARRIER TB 11 GENERAL PURPOSE
D
ESP50H 3 1 (+24V) 5A PSU
CLEAN 4 2 (0V) GP01
S31-105
TYPE: MULTICORE
VOLTS: 24V DC
AMPS: 3A
EMC LEVEL: B

E E

TITLE:
F TYPICAL CLASS 2 DP SYSTEM F
ANEMOMETER 1
CABLE INTERCONNECTION DIAGRAM
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam UK Ltd. DRG. No. SHEET:S31 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

NOTE:
THIS PAIR BROUGHT INTO LIGHTNING
A PROTECTION UNIT AND EARTHED (FOR A
REPROGRAMMING ANEMOMETER IF REQUIRED)
ANY SPARE CORES TO BE KEPT WELL AWAY
MAE 99-04 FROM CLEAN CONNECTIONS.
SIAb TB2 LIGHTNING BARRIER

(RXA-) 4 4
PAIR 1 ESPD15D
CLEAN LIGHTNING BARRIER LOCAL JB
(RXB+) 5 3
2 1 (TXB+) LOCAL
ESP15D PAIR 1
( 0v) 3 4 JB FLYING LEAD
LINE
PAIR 2 ESPD15D 1 3 (TXA-)
CLEAN 1 Green (TXB+)
( 0v) 3 3 S 4 (RXB+) 2 Ind.scn PAIR 1
PAIR 2
3 Black (TXA-)
LIGHTNING BARRIER S 6 (RXA-) LOCAL JB
Overall scn overall screen
not connected &
ESP30E
SHIPYARD 4 White (RXB+) ANEMOMETER 2
LINE 2 7 (+24Vdc) PAIR 2
insulated from earth 5 Ind.scn Gill
PAIR 3 SUPPLY 6 Black (RXA-)
Any unused screens or
console earth bar drain wires to be insulated 1 9 (0Vdc)
7 Red (+24Vdc)
Windobserver II
from each other and earth 2 10 (RS422 0v)
B 8 Ind.scn PAIR 3 B
PAIR 4
ESP15D 9 Black (0Vdc)
LINE
1 12 (0Vdc)
10 Blue (RS422 0v)
with heater
S 2 Overall scn 11 Ind.scn PAIR 4 1390 pk 007

ESP50H ESP15D ESP30E ESP15D


ESP15D ESP30E ESP15D ESP50H
1

CLEAN CLEAN CLEAN CLEAN


12 Black (0Vdc)

2
4 S 3

LINE
Any unused screens 2

S
LINK 2 TO 5 TO 8 TO 11 13 Yellow (Heater +)
or drain wires to be 3
PAIR 5

1
connected to ESP15D 4 14 Ind.scn
'S' terminal 5 15 Black (Heater -)

2
TO SHT.S16

4 S 3

LINE
6

S
S32-101 S32-102 7 S32-103
CC02-TB2 NOTE:

1
TYPE: 3 TW PAIR OAS TYPE: 4 TW PAIR OAS 8 TYPE: 9 PAIR FLYING LEAD
VOLTS: 24V DC ON EARTH CONNECTION
VOLTS: 24V DC 9 ATTACHED TO

2
BETWEEN ANEMOMETER

4 S 3

LINE
AMPS: LOW LIGHTNING AMPS: LOW 10 ANEMOMETER

S
EMC LEVEL: A BARRIER TB MOUNTING BOLT AND
EMC LEVEL: A 11 VOLTS: RS422
MAST BOLT, ENSURE

1
NOTE: THIS CABLE AND ANY 1 13 12 AMPS: LOW
ESP50H GOOD CONNECTIONS
SPARE CORES,TO BE LINE 2 15 13 EMC LEVEL: A

1 S 2
4 S 3
WITH ANTI-CORROSIVE

LINE
KEPT WELL AWAY FROM 14 NOTE: CABLE 1.5M LENGTH.
S32-104 PROPERTIES.
THE LINE SIDE ANEMOMETER 15 ALL UNUSED PAIRS
C CONNECTIONS
TYPE: MULTICORE
MUST BE INSULATED
C
VOLTS: 24V DC
AMPS: 3A FROM EARTH AND
EACH OTHER
EMC LEVEL: B

Bridge Mast Mast


LIGHTNING
DP TB13 BARRIER
CONTROLLER (+24Vdc) 5 4
ESP30E E6 E6
CC02 PAIR 3
CLEAN E16 Max length 1m
(0Vdc) 6 3

TYPE: PART OF ABOVE TWISTED PAIRS CABLE

LIGHTNING
D BARRIER TB 11 GENERAL PURPOSE
D
ESP50H 3 1 (+24V) 5A PSU
CLEAN 4 2 (0V) GP02
S32-105
TYPE: MULTICORE
VOLTS: 24V DC
AMPS: 3A
EMC LEVEL: B

E E

F TITLE: F
TYPICAL CLASS 2 DP SYSTEM
ANEMOMETER 2
CABLE INTERCONNECTION DIAGRAM
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam Ltd.
UK Ltd. DRG. No. SHEET:S32 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

NOTE:
THIS PAIR BROUGHT INTO LIGHTNING
A PROTECTION UNIT AND EARTHED (FOR A
REPROGRAMMING ANEMOMETER IF REQUIRED)
ANY SPARE CORES TO BE KEPT WELL AWAY
MAE 99-04 FROM CLEAN CONNECTIONS.
SIBa TB2 LIGHTNING BARRIER

(RXA-) 4 4
PAIR 1 ESPD15D
CLEAN LIGHTNING BARRIER LOCAL JB
(RXB+) 5 3
2 1 (TXB+) LOCAL
ESP15D PAIR 1
( 0v) 3 4 JB FLYING LEAD
LINE
PAIR 2 ESPD15D 1 3 (TXA-)
CLEAN 1 Green (TXB+)
( 0v) 3 3 S 4 (RXB+) 2 Ind.scn PAIR 1
PAIR 2 3 Black (TXA-)
LIGHTNING BARRIER S 6 (RXA-) LOCAL JB
Overall scn overall screen
not connected &
ESP30E
SHIPYARD 4 White (RXB+) ANEMOMETER 3
LINE 2 7 (+24Vdc) PAIR 2
insulated from earth 5 Ind.scn Gill
PAIR 3 SUPPLY 6 Black (RXA-)
Any unused screens or
console earth bar drain wires to be insulated 1 9 (0Vdc)
7 Red (+24Vdc)
Windobserver II
from each other and earth 2 10 (RS422 0v)
B 8 Ind.scn PAIR 3 B
PAIR 4
ESP15D 9 Black (0Vdc)
LINE
1 12 (0Vdc)
10 Blue (RS422 0v)
with heater
S 2 Overall scn 11 Ind.scn PAIR 4 1390 pk 007

ESP50H ESP15D ESP30E ESP15D


ESP15D ESP30E ESP15D ESP50H
1

CLEAN CLEAN CLEAN CLEAN


12 Black (0Vdc)

2
4 S 3

LINE
Any unused screens 2

S
LINK 2 TO 5 TO 8 TO 11 13 Yellow (Heater +)
or drain wires to be 3
PAIR 5

1
connected to ESP15D 4 14 Ind.scn
'S' terminal 5 15 Black (Heater -)

2
TO SHT.S17

4 S 3

LINE
6

S
S33-101 S33-102 7 S33-103
CC01-TB2 NOTE:

1
TYPE: 3 TW PAIR OAS TYPE: 4 TW PAIR OAS 8 TYPE: 9 PAIR FLYING LEAD
VOLTS: 24V DC ON EARTH CONNECTION
VOLTS: 24V DC 9 ATTACHED TO

2
BETWEEN ANEMOMETER

4 S 3

LINE
AMPS: LOW LIGHTNING AMPS: LOW 10 ANEMOMETER

S
EMC LEVEL: A BARRIER TB MOUNTING BOLT AND
EMC LEVEL: A 11 VOLTS: RS422
MAST BOLT, ENSURE

1
NOTE: THIS CABLE AND ANY 1 13 12 AMPS: LOW
ESP50H GOOD CONNECTIONS
SPARE CORES,TO BE LINE 2 15 13 EMC LEVEL: A

1 S 2
4 S 3
WITH ANTI-CORROSIVE

LINE
KEPT WELL AWAY FROM 14 NOTE: CABLE 1.5M LENGTH.
S33-104 PROPERTIES.
THE LINE SIDE ANEMOMETER 15 ALL UNUSED PAIRS
C CONNECTIONS
TYPE: MULTICORE
MUST BE INSULATED
C
VOLTS: 24V DC
AMPS: 3A FROM EARTH AND
EACH OTHER
EMC LEVEL: B

Bridge Mast Mast


LIGHTNING
DP TB13 BARRIER
CONTROLLER (+24Vdc) 7 4
ESP30E E6 E6
CC01 PAIR 3 E16 Max length 1m
CLEAN
(0Vdc) 8 3

TYPE: PART OF ABOVE TWISTED PAIRS CABLE

LIGHTNING
D BARRIER TB 11 GENERAL PURPOSE
D
ESP50H 3 1 (+24V) 5A PSU
CLEAN 4 2 (0V) GP03
S33-105
TYPE: MULTICORE
VOLTS: 24V DC
AMPS: 3A
EMC LEVEL: B

E E

TITLE:
F TYPICAL CLASS 2 DP SYSTEM F
ANEMOMETER 3
CABLE INTERCONNECTION DIAGRAM
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam Ltd.
UK Ltd. DRG. No. SHEET:S33 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE
6

4
5
A A
tem Description Part No. Qty
1 VERIPOS Integrated Receiver See Sheet Title 1
2 Monitor (Converteam supply) N/A 1
3 Rack Mount Keyboard & Trackball VI-V-0031 1
4 AD410 Antenna - L1 / GLONASS VI-A-0011 1
5 A30 Triband Antenna VI-A-0018 1
6 90984 L-Band Antenna VI-A-0013 1
9 7 NF to NF cable assembly - 30 metres VI-C-0010 1 +2
8 NM to NM cable assembly - 2 metres VI-C-0011 3
9 NM to NM cable assembly - 2 metres VI-C-0012 1 +2

VI-C-0011
VI-C-0011

VI-C-0012
10 KVM Extension Cable - 5 metres VI-V-0023 1
11 IEC Mains Lead - 5 metres - unterminated VI-C-0025 2
12 Earth Braid Cable Assembly VI-C-0015 1

8
B B

DISPLAY
7
VI-C-0010

VI-C-0010
VI-C-0010

2
TB
C 11 L C
VI-C-0025 N SEE SHEET P11 FOR UPS POWER FEED TO DGPS1
VERIPOS RACK
VI-V-0018 P11-04

D D
LOCAL JUNCTION BOX
8
(SHIPYARD SUPPLY)
9 10
TB
L
VI-C-0011
VI-C-0012
VI-C-0012

VI-C-0025 N SEE SHEET P11 FOR UPS POWER FEED TO DGPS1


P11-02

11
1 REAR ELEVATION

DB9 FEMALE MAE 99-04


CAD FILE = J:\MARINE\TENDERS\TG12900\TG12945\DPS21 DUPLEX DP+IJS\ESDI-1R46240-SHS41.DWG

(TXB) 3 5 (RXB)
E PAIR 1 (TXA) 8 4 (RXA) E
VI-C-0015 (0V) 4 3 (0V)
PAIR 2 (0V) 4 3 (0V)
NOT CONN. EARTH BAR (OAS)
S41-01 DGPS1 SERIAL LINK INPUT TO DP
12 TYPE : 2TW PAIR OAS CONTROLLER
VOLTS : LOW SEE SHEET S15 CC01-SIAa TB4
AMPS : RS422
FRONT ELEVATION EMC LEVEL : A
DC Supply

Sync HF Lock

ID GPS

Message DGPS

3 TITLE:
F TYPICAL CLASS 2 DP SYSTEM F
COMBINED TRACKBALL & KEYBOARD DGPS 1 VERIPOS LID2-GG1
CABLE INTERCONNECTION DIAGRAM
CUSTOMER: ORDER No.
STANDARDS
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS STD
any other person nor copied in whole or part except with the prior written consent of Converteam UK Ltd. DRG. No. SHEET:S41 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE
ITEM DESCRIPTION PART No. QTY

1 VERIPOS INTEGRATED RECEIVER LD-3 1


10 2 POWER I/O CABLE ASSEMBLY VI-C-0017 1
3 CONFIGURATION CABLE ASSEMBLY VI-C-0016 1

5 PASSIVE RF SPLITTER VI-R-0016 1


A 6 "N" MALE TO "TNC" MALE LOW LOSS CABLE ASSEMBLY-1.5 METRES VI-C-0012 3 A
7 "N" MALE TO "N" MALE LOW LOSS CABLE ASSEMBLY-1.5 METRES VI-C-0011 1
8 "N" FEMALE TO "N" FEMALE LOW LOSS CABLE ASSEMBLY-30 METRES VI-C-0010 1

10 CDA3 TRIBAND ANTENNA VI-A-0015 1


6

VI-C-0012
8

VI-C-0010
B B

VI-C-0011
5

C C
6 6 MAE99-04
TB SIAb TB4
DGPS (NMEA OUT 1) 7 5 (RXB)

VI-C-0012

VI-C-0012
4 (RXA) PAIR 1
6
JB LINK
(0V) 5 3 (0V)
PAIR 2
(0V) 5 3 (0V)
NO CONN. EARTHBAR (OAS)

(Shipyard S42-01
1 Supply) TYPE: 2TW PAIR OAS
VOLTS: RS422
LID3-G1 AMPS: LOW
REAR ELEVATION EMC LEVEL: A

TO CC02
SHT S16
D D
TB TB13
F
A B
G
C
2 AMPHENOL 1 9 (+24V)
E D
CONNECTOR TB 2 10 (0V)
(RTCM OUT 1) RED 4 S42-02
TYPE: MULTICORE
(0V) BLACK 5
. . 6 VOLTS: 24V DC
VI-C-0017 (NMEA OUT 1) WHITE 7 AMPS: 1A
VI-C-0017
NMEA OUT
EMC LEVEL: B
AMPHENOL
CONNECTOR TB
VI-C-0017 (+24V) WHITE 1
11 - 36 VDC (0V) BLACK 2
LID3-G1 VI-C-0017
11 - 36 VDC

FRONT ELEVATION
CAD FILE = J:\MARINE\TENDERS\TG12900\TG12945\DPS21 DUPLEX DP+IJS\ESDI-1R46240-SHS42.DWG

E E

A F
B
C D
G
E (9-PIN
3 VI-C-0016 FEMALE)
GPS
VI-C-0016
GPS

(9-PIN
VI-C-0016 FEMALE)
OEM
VI-C-0016
OEM

F TITLE: F
TYPICAL CLASS 2 DP SYSTEM
DGPS3 VERIPOS LID3-G1
CABLE INTERCONNECTION DIAGRAM
CUSTOMER: ORDER No.
STANDARDS
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS STD
any other person nor copied in whole or part except with the prior written consent of Converteam UK Ltd. DRG. No. SHEET:S42 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

MAE99-04 CYSCAN PSU


SIAa-TB6 TERMINALS

(RXA) 4 18 (TXA)
PAIR 1
A (RXB) 5 19 (TXB) A
(0V) 3 14 (GND) CYSCAN CYSCAN
PAIR 2
NOT CONN NOT CONN PSU & SENSOR
TO SHEET S15 EARTH (OAS)
S50-01 JUNCTION BOX S50-05
INPUT POWER - 24V DC
CC01-TB6
TYPE: SL 3TW PAIR OAS
(DECK AREA) SUPPLIED FLYING LEAD 1.5M LONG. (DECK AREA)
VOLTS: RS485
AMPS: LOW
EMC LEVEL: A

CONSOLE COM 2
FEMALE 9-WAY CONSOLE
D-TYPE TERMINALS

PIN 4 9 (TXA) DP FEED - RS485


CYSCAN CYSCAN PIN 3 10 (TXB)
PAIR 1 S50-06
CONSOLE CONSOLE PIN 1 11 (RXA)
PAIR 2
PIN 2 8 (RXB) SUPPLIED FLYING LEAD 1.5M LONG.
DISPLAY S50-03 (BRIDGE)
PIN 5 5 (GND)
PAIR 3
B (BRIDGE) NOT CONN NOT CONN B
POWER CABLE
(SUPPLIED - 1M LONG) S50-02
TYPE: SL 3TW PAIR OAS
VOLTS: RS485
S50-04 AMPS: LOW
EMC LEVEL: A
VGA DISPLAY CABLE
(SUPPLIED 1M LONG)

DISPLAY/DIAGNOSTICS
S50-07
SUPPLIED FLYING LEAD 1.5M LONG.

S50-08
C SWITCHED POWER
C
SOCKET TERMINALS

L L
SWITCHED N
EARTH
N
E
20A DOUBLE
POLE SWITCH
CYSCAN PSU
TERMINALS
SOCKET
L 1 (90-264V AC)
(SHIPYARD SUPPLY) N 2 (NEUTRAL)
EARTH 3 (EARTH)
FROM UPS 20A
SHEET P11
DOUBLE POLE
CONTROL S50-09
SWITCH
(WITH NEON)
(SHIPYARD SUPPLY)
D D
CAD FILE = J:\MARINE\TENDERS\TG12900\TG12945\DPS21 DUPLEX DP+IJS\ESDI-1R46240-SHS50.DWG

E E

F TITLE: F
TYPICAL CLASS 2 DP SYSTEM
CABLE INTERCONNECTION DIAGRAM
CYSCAN 1
CUSTOMER: ORDER No.
STANDARDS
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England - ALLAN PTASZYNSKI PAUL BIGGS -
any other person nor copied in whole or part except with the prior written consent of Converteam Ltd.
UK Ltd. DRG. No. SHEET:S50 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

A A
VOYAGE
DATA
RECORDER
MAE99-04 RS422
SIAb-TB5 SERIAL

(TXA) 4 . (RXA)
(TXB) 5 . (RXB)
PAIR 1 (CUSTOMER
(0V) 3 . (0V)
PAIR 2
SUPPLY)
(0V) 3 . (0V)
TO SHEET S16 EARTH (OAS)
CC01-TB5 S60-01
TYPE: SL 3TW PAIR OAS
VOLTS: RS422
AMPS: LOW
EMC LEVEL: A
B B

MAE99-04 RS422
SIAb-TB5 SERIAL
C C
(TXA) 4 . (RXA)
PAIR 1
(TXB) 5 . (RXB)
(0V) 3 . (0V)
PAIR 2
(0V) 3 . (0V)
TO SHEET S16 EARTH (OAS)
CC02-TB5 S60-01
TYPE: SL 3TW PAIR OAS
VOLTS: RS422
AMPS: LOW
EMC LEVEL: A

D D
CAD FILE = J:\MARINE\TENDERS\TG12900\TG12945\DPS21 DUPLEX DP+IJS\ESDI-1R46240-SHS60.DWG

E E

F TITLE: F
TYPICAL CLASS 2 DP SYSTEM
CABLE INTERCONNECTION DIAGRAM
VOYAGE DATA RECORDER
CUSTOMER: ORDER No.
STANDARDS
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England - ALLAN PTASZYNSKI PAUL BIGGS -
any other person nor copied in whole or part except with the prior written consent of Converteam Ltd.
UK Ltd. DRG. No. SHEET:S60 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

A A

MAN-DP/IJS IPC1 MAN-DP/IJS IPC1


MANUAL/ DP/IJS 1/1 DI 03/5 SWITCH CONTACT 1 OF 8 MANUAL - DP/IJS 2/1 DI 03/5 SWITCH CONTACT 2 OF 8
CHANGEOVER 1/2 DI 03/8 CLOSED FOR DP/IJS CHANGEOVER 2/2 DI 03/8 CLOSED FOR DP/IJS
SWITCH (BRIDGE) NOT CONN. (OAS) EARTH BAR SWITCH (BRIDGE) NOT CONN. (OAS) EARTH BAR

CONTACT 1 OF 8 T01-101 CONTACT 2 OF 8 T01-201


TYPE: 1 TW PAIR OAS TYPE: 1 TW PAIR OAS
VOLTS: 24V VOLTS: 24V
AMPS: LOW IPC1 Wx65 AMPS: LOW IPC1 Wx65
EMC LEVEL: B EMC LEVEL: B
DO 01/1 . DP SWITCH DO 01/1 . DP SWITCH
DO 01/2 . CLOSED FOR DP DO 01/2 . CLOSED FOR DP
(OAS) EARTH BAR NOT CONN. (OAS) EARTH BAR NOT CONN.

T01-102 T01-202
TYPE: 1 TW PAIR OAS TYPE: 1 TW PAIR OAS
B VOLTS: 24V VOLTS: 24V B
AMPS: LOW AMPS: LOW
EMC LEVEL: B EMC LEVEL: B
IPC1 Wx68 IPC1 Wx68
DI 04/1 . CLOSED FOR HRP DI 04/1 . CLOSED FOR HRP
DI 04/4 . AVAILABLE TO DP DI 04/4 . AVAILABLE TO DP
DP CONTROLLER DI 04/5 . CLOSED WHEN HRP DI 04/5 . CLOSED WHEN HRP
BOW TUNNEL BOW TUNNEL
CC01 DI 04/8 . UNDER DP DP CONTROLLER DI 04/8 . UNDER DP
(MOST FWD) (MOST AFT)
(OAS) EARTH BAR NOT CONN. CC02 (OAS) EARTH BAR NOT CONN.
HRP CONTROL HRP CONTROL
T01-103 T01-203
TYPE: 2 TW PAIR OAS TYPE: 2 TW PAIR OAS
VOLTS: 24V VOLTS: 24V
AMPS: LOW AMPS: LOW
VIA EMC LEVEL: A VIA
EMC LEVEL: A
ISOL 1 Wx68 ISOL 1 Wx68
ISO 1/7 . RPM ORDER ISO 1/7 . RPM ORDER
ISO 1/9 . 4-20mA ISO 1/9 . 4-20mA
C (OAS) EARTH BAR NOT CONN. (OAS) EARTH BAR NOT CONN. C
T01-104 T01-204
TYPE: 1 TW PAIR OAS TYPE: 1 TW PAIR OAS
VOLTS: 24V VOLTS: 24V
AMPS: LOW AMPS: LOW
EMC LEVEL: A EMC LEVEL: A
IPC1 Wx68 IPC1 Wx68
AI 01/1 . RPM FEEDBACK AI 01/1 . RPM FEEDBACK
AI 01/3 . 4-20mA AI 01/3 . 4-20mA
(OAS) EARTH BAR NOT CONN. (OAS) EARTH BAR NOT CONN.

T01-105 T01-205
TYPE: 1 TW PAIR OAS TYPE: 1 TW PAIR OAS
VOLTS: 24V VOLTS: 24V
AMPS: LOW AMPS: LOW
EMC LEVEL: A EMC LEVEL: A

D D

E E

F TITLE: F
TYPICAL CLASS 2 DP SYSTEM
CABLE INTERCONNECTION DIAGRAM
TUNNEL THRUSTERS
CUSTOMER: ORDER No.
STANDARDS
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam UK Ltd. DRG. No. SHEET:T01 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

A A

MAN-DP/IJS IPC2 MAN-DP/IJS X101


MANUAL/ DP/IJS 3/1 DI 04/1 SWITCH CONTACT 3 OF 8 MANUAL - DP/IJS 4/1 DI 04/1 SWITCH CONTACT 4 OF 8
CHANGEOVER 3/2 DI 04/4 CLOSED FOR DP/IJS CHANGEOVER 4/2 DI 04/4 CLOSED FOR DP/IJS
SWITCH (BRIDGE) NOT CONN. (OAS) EARTH BAR SWITCH (BRIDGE) NOT CONN. (OAS) EARTH BAR

CONTACT 3 OF 8 T02-102 CONTACT 4 OF 8 T02-202


TYPE: 1 TW PAIR OAS TYPE: 1 TW PAIR OAS
VOLTS: 24V VOLTS: 24V
AMPS: LOW IPC2 X101 AMPS: LOW IPC2 X101
EMC LEVEL: B EMC LEVEL: B
DO 01/1 . DP SWITCH DO 01/1 . DP SWITCH
DO 01/2 . CLOSED FOR DP DO 01/2 . CLOSED FOR DP
(OAS) EARTH BAR NOT CONN. (OAS) EARTH BAR NOT CONN.
T02-102 T02-202
TYPE: 1 TW PAIR OAS TYPE: 1 TW PAIR OAS
B VOLTS: 24V VOLTS: 24V B
AMPS: LOW AMPS: LOW
EMC LEVEL: B EMC LEVEL: B
IPC2 X101 IPC2 X101
DI 04/5 . CLOSED FOR HRP DI 04/5 . CLOSED FOR HRP
DI 04/8 . AVAILABLE TO DP DI 04/8 . AVAILABLE TO DP
DP CONTROLLER DI 05/1 . CLOSED WHEN HRP DI 05/1 . CLOSED WHEN HRP
CC01 DI 05/4 . UNDER DP PORT AZIMUTH DP CONTROLLER DI 05/4 . UNDER DP STBD AZIMUTH
(OAS) EARTH BAR NOT CONN. STEER PROP CC02 (OAS) EARTH BAR NOT CONN. STEER PROP
T02-103 CONTROL SCU T02-203 CONTROL SCU
TYPE: 2 TW PAIR OAS TYPE: 2 TW PAIR OAS
VOLTS: 24V VOLTS: 24V
AMPS: LOW AMPS: LOW
EMC LEVEL: A VIA EMC LEVEL: A VIA
ISOL 1 & 2 X101 ISOL 1 & 2 X101
ISOL1 1/7 . RPM ORDER ISOL1 1/7 . RPM ORDER
ISOL1 1/9 . 4-20mA ISOL1 1/9 . 4-20mA
C ISOL2 2/7 . AZI DEMAND ISOL2 2/7 . AZI DEMAND
C
ISOL2 2/9 . 4-20mA ISOL2 2/9 . 4-20mA
(OAS) EARTH BAR NOT CONN. (OAS) EARTH BAR NOT CONN.
T02-104 T02-204
TYPE: 1 TW PAIR OAS TYPE: 1 TW PAIR OAS
VOLTS: 24V VOLTS: 24V
AMPS: 4-20mA AMPS: 4-20mA
EMC LEVEL: A EMC LEVEL: A
IPC2 X101 IPC2 X101
AI 01/1 . RPM FEEDBACK AI 01/1 . RPM FEEDBACK
AI 01/3 . 4-20mA AI 01/3 . 4-20mA
AI 01/5 . AZI READBACK AI 01/5 . AZI READBACK
AI 01/7 . 4-20mA AI 01/7 . 4-20mA
(OAS) EARTH BAR NOT CONN. (OAS) EARTH BAR NOT CONN.
T02-105 T02-205
TYPE: 1 TW PAIR OAS TYPE: 1 TW PAIR OAS
D D
VOLTS: 24V VOLTS: 24V
AMPS: 4-20mA AMPS: 4-20mA
EMC LEVEL: A EMC LEVEL: A

E E

F TITLE: F
TYPICAL CLASS 2 DP SYSTEM
AZIMUTH THRUSTERS
CABLE INTERCONNECTION DIAGRAM
CUSTOMER: ORDER No.
STANDARDS.
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam UK Ltd. DRG. No. SHEET:T02 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 2
*

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

COMMERCIAL IN CONFIDENCE

IPC2 .
DP
DI 01/5 MAIN
A CONTROLLER .
GEN 1 CB CLOSED A
DI 01/8 . SWITCHBOARD
CC01
DI 02/1 .
690V 3PH 50Hz
DI 02/4 GEN 2 CB CLOSED
.
DI 03/1 .
DI 03/4 BOW TUNNEL (FWD) CB CLOSED
.
DI 02/5 .
DI 02/8 PORT AZIMUTH CB CLOSED
.
DI 02/5 .
DI 02/8 BUSTIE CB CLOSED
.
(OAS) EARTH BAR NOT CONN.
T03-101
TYPE: 5TW PAIRS OAS
VOLTS: 24V DC
AMPS: LOW
B EMC LEVEL: A B

PORT SIDE
IPC2 .

AI 02/1 .
GEN 1 KW LOAD 4-20mA
AI 02/3 .
AI 02/5 .
GEN 2 KW LOAD 4-20mA
AI 02/7 .
(OAS) EARTH BAR NOT CONN.
T03-102
TYPE: 3TW PAIRS OAS
VOLTS: 24V DC
AMPS: LOW
C EMC LEVEL: A C

DP
CONTROLLER IPC2 .
CC02
DI 01/5 .
DI 01/8 GEN 3 CB CLOSED
.
DI 02/1 .
DI 02/4 GEN 4 CB CLOSED
D . D
DI 03/1 .
DI 03/4 BOW TUNNEL (AFT) CB CLOSED
.
DI 03/5 .
DI 03/8 STBD AZIMUTH CB CLOSED
.
(OAS) EARTH BAR NOT CONN.
T03-103
TYPE: 5TW PAIRS OAS
VOLTS: 24V DC
AMPS: LOW
EMC LEVEL: A

STBD SIDE
E E
IPC2 .

AI 02/1 .
GEN 3 KW LOAD 4-20mA
AI 02/3 .
AI 02/5 .
GEN 4 KW LOAD 4-20mA
AI 02/7 .
(OAS) EARTH BAR NOT CONN.
T03-104
TYPE: 3TW PAIRS OAS
VOLTS: 24V DC
AMPS: LOW
EMC LEVEL: A

F TITLE: F
TYPICAL CLASS 2 DP SYSTEM
SWITCHBOARD INTERFACE
CABLE INTERCONNECTION DIAGRAM
CUSTOMER: ORDER No.
STANDARDS
ORIGINATOR: DRAWN BY: APPROVED: CHECKED:
This document contains commercially confidential information and its contents must not be disclosed to Converteam UK Ltd. Rugby England STD-R01 ALLAN PTASZYNSKI PAUL BIGGS
any other person nor copied in whole or part except with the prior written consent of Converteam UK Ltd. DRG. No. SHEET:T03 DRAWING
Original sheet size A1 (841mm x 594mm) - prints may not be to original size. do not measure off this drawing
All Rights Reserved Copyright © Converteam UK Ltd. 2010 ESDI-xRxxxxx CONT'D: - REVISION: 1
*

1 2 3 4 5 6 7 8

You might also like