4.

Operation Method

4.1 Caution before supply power to the master clock


1) Confirms inner connectors of the master clock and connection of external cables to the
terminals.
2) Confirms connection and grounding general and emergency power.
3) Confirms polarity of emergency power DC+24V.
4) Confirms suitable regular voltage level of general and emergency power.
5) Confirms wiring of input signal from GPS.
6) Confirms wiring of digital and analog slave clock. (power & signal lines)
7) Confirms identically time indication analog slave clock which is established.
Must be equaled time of the analog slave clocks.
(At the time of factory shipping indicates 12:00:00)
Fault Signal (Power PCB Terminal Block : J100) Power Fault.

4.2 Operation

1) Method of operation world-wide standard time (UTC)


The UTC of the master clock turns on the power switch and from GPS the signal comes
in and it comes to fix with automatic movement.
When from GPS the signal comes in to the master clock and it indicates the UTC time
from GPS information and Inside the “D1” LED blinks.
In case of do not input signal from GPS, you will want fixing a UTC time with option,
“AUTO/MANU” switch puts “AUTO” and “24/12” switch puts “24” and time is increment and

decrease pushing, , switch and “24/12” switch puts “12” and minute is increment and

decrease pushing , switch. Press the , switch above 1 second it is increases

and decrease at the case 10 units.


Second-hand Set

: “AUTO/MANU” switch puts “AUTO” and “24/12” switch puts “24” and press the switch of

3 or more seconds and the second hand becomes “00”. When takes off the switch and

the second increases. ( In case of do not input signal from GPS.)


In case of no GPS signal, if you want fixing a desired time with option, the following
procedure must be carried out. ( If the GPS signal is received, the date is set
automatically using the data received.)
- Put “AUTO/MANU” switch “MANU”.
- Push , switch for more than 3 seconds simultaneously, you will enter “Date Setting

Mode”.
- At this “Date Setting Mode”, “UTC Time Display” indicates year, “LTC Time Display”
indicates month and day in order. And “date default value” is January 1, 2012 (UTC Time
Display : 2012, LTC Time Display : 0101).
- When “date value” is blinking, you can modify it. The first digit of year is a starting point for

modifying value. And switch is used to increase by 1. Date value will increase

automatically if the switch is pushed for more than 1 second.

- Blinking position is shifted 1 digit to right by pushing switch. And after completing the

last digit of day value of modifications, you can exit back to “Time Display Screen” by pushing

switch once more.

2) Method of operation slave clock


Function of each switch
- AC, DC POWER SWITCH : General and emergency power

- ANALOG SWITCH : Operation switch for analog slave clock activity


- AUTO/MANU SWITCH : Selecting automatically or manually time adjustment for local
time display
- 24/12 SWITCH : Indication 24hour or AM/PM for local time display

- & SWITCH : Changing time and minute of local ootime and UTC time.
MASTER CLOCK CONTROL PANEL

ON ON
ANALOG
ON AUTO 24 SET
(UTC) (TIME)

(LTC) (MIN)
DIMMER OFF MANU 12 TIME
AC DC

First the control panel condition, ANALOG switch is “OFF”, AUTO/MANU switch is
“AUTO”, 24/12 switch is “24”.
Turns on the power switch and pass the little times(within 30 seconds, GPS activity),
master clock indicates UTC of present time in the left and local time in the right which is
calculated currently location of the vessel. ((Ex.) UTC : 01:30, Local time 10:30 (in Rep. of
Korea 9 hours)
In case of you will want fixing a local time with option, “AUTO/MANU” switch puts “MANU”

and “24/12” switch puts “24” and time is increment and decrease pushing , switch

and “24/12” switch puts “12” and minute is increment and decrease pushing , switch.

Press the , switch above 1 second it is increases and decrease at the case 10 units.

If you want to indicate A.M and P.M in local time display, puts the “12” direction “24/12”
switch. Automatically AM, PM indicates and in case UTC is 24 hours.
After master clock was setting, digital slave clock come to fix local time of master clock
exactly within 30 seconds.
Operation method of analog slave clock (First installation)
- Master clock is normal operation status and display currently UTC.
- When currently all of the analog slave clocks coming to fix in “12:00:00”, “AUTO/MANU” key

of the master clock lets with “MANU” direction and fixes the “11:59:xx” operating ,
switch.
- At the moment “12:00:00” local clock, “ANALOG” switch puts the “ON”.
- Analog slave clock operates.
- When “AUTO/MANU” key of the master clock lets with “AUTO” direction, change the digital
local time and also adjusting analog slave clock automatically.
Operation method of exchange slave clock
- When the digital slave clock breakdown, separates wiring and exchange new digital slave
clock, it is rightly indicated.
- Be careful wiring power and signal line of digital slave clock.

- In case of operation method of exchange the breakdown analog slave clock, “ANALOG”
switch puts the “OFF” specified time. (Example: specified time “10:35:00” analog slave clock
stopped, digital slave clock keep up activity)
- Removed the breakdown analog slave clock, and installs new analog slave clock after
setting “10:35:00”. (All of the analog slave clock indicates 10:35:00) - “AUTO/MANU” key of

the master clock lets with “MANU” direction, setting local time “10:34:xx” by pushing ,
switch.
- When local time display of master clock indicates “10:35:00”, puts the ANALOG switch is
“ON” and then all of analog & digital slave clock is settled.
- In order to fix the practice local time, “AUTO/MANU” key of the master clock lets with

“AUTO” direction or doing manual operation push the , switch “MANU” direction.

Current capacity each slave clock is as show below.


Type Pulse & Protocol Power consumption
2 hand slave clock 30sec. Polarized Pulse DC24V 12mA
0.5sec. ditto DC24V 12mA
3 hand slave clock
30sec. ditto DC24V 12mA
Digital slave clock RS-422, Maker Protocol DC24V 150mA
Note : Double faced type is twice as much above table.

3) Operation method of Logger signal


Logger out is equal analog out signal. Therefore it is applicable engine telegraphy
logger data.
Capacity of output for logger use is as follows.
Pulse Output capacity
00sec. Polarized Pulse 40mA
30sec. Polarized Pulse 40mA
Never load the master clock circuit with the logger in excess of the specified
capacity as shown above if the logger input circuit use a relay provide a spark
killer.