Civil Audit Check List

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

QUALITY CHECKLIST FOR SITE WORKS

SURVEYING AND SETTING OUT


ARCHITECTURAL STRUCTURL INTERIOR SERVICES & UTILITY

Name of the Customer: Date:

Project Name: Project ID:

Name of the Contractor: Location:

Drawing Ref. No.: Quantity:

CL : 01
Sl.No. Description YES NO NA

1 Is contour/ survey plan available?

2 Establishment of Co-ordination points, MAIN GRID LINES,


CENTRE LINES in both directions, block levels, spot level etc.
Is it as per Drawings?
3 Check for set back are they as per the norms of local authority
approval drawing?

4 Check whether there is any variation in the actual marking and


whether it is recorded/ reported?

5 LOCATION of INDIVIDUAL STRUCTURAL ELEMENTS like


Column footings, columns, location of pile, etc.,
Are they as per Drawings?
CORRECTIVE ACTION PROPOSED- Item wise.
If 'No' is marked, please specify reasons and thereafter corrective action proposed.
(Add additional sheets, if necessary)
Comments:
QUALITY CHECKLIST FOR SITE WORKS
EARTH WORK/ BACKFILLING
ARCHITECTURAL STRUCTURAL SITE SERVICES & UTILITY

Name of the Customer: Date:

Project Name: Project ID:

Name of the Contractor: Location:

Drawing Ref. No.: Quantity:

CL : 02
Sl.No. Description YES NO NA
1 Is format CL: 01 for Surveying complied with?
2 Whether suitable arrangements for re-routing the service lines
done?
3 Is the LAYOUT, ALIGNMENT and SIZE of Excavation marked
on the ground as per drawings?
4 Is adequate shoring, strutting done?
5 Check for DEWATERING. Is it O.K.?

6 Is the excavation done up-to the level as per drawing.

A. NATURAL EXISTING GROUND LEVEL :

B. FOUNDING LEVEL :

C. DEPTH OF EXCAVATION :

BACKFILLING

1 Is the earth used for filling as per specification?

2 Check for the approved method of compaction, ie. (Roller, plate


compactor, etc.,)
3 Whether Proctor compaction test carried out satisfactorily as
per the requirement?
CORRECTIVE ACTION PROPOSED- Item wise.
QUALITY CHECKLIST FOR SITE WORKS
CONCRETE POUR CARD

ARCHITECTURAL STRUCTURAL INTERIOR SERVICES & UTILITY

Name of the Customer: Date:

Project Name: Project ID:

Name of the Contractor: Location:

Drawing Ref. No.: Grade & Quantity :

CL : 03
Sl.No. Description YES NO NA
A. FORM WORK:
1 Level
2 Plumb
3 Cutouts
B. Reinforcement:
1 As per bar bending schedule
2 Dowel bars
3 Links

4 Binding/ Welding

C. Services:

1 Position

2 Size

3 Trimming bars
D. General
1 Embedments
2 Water proofing
3 Construction Joint
E. Sampling:
1 Mix as per design :
2 No. of sample & Identity
IF 'YES', THEN SITE ENGINEER SHALL TAKE SUITABLE CORRECTIVE ACTION in consultation with
PRT/ AST/ PRM AND RECHECK .
CORRECTIVE ACTION PROPOSED- Item wise.
If 'No' is marked, please specify reasons and thereafter corrective action proposed.
(Add additional sheets, if necessary)
Comments:
QUALITY CHECKLIST FOR SITE WORKS
WATER PROOFING
ARCHITECTURAL STRUCTURAL INTERIOR SERVICES & UTILITY

Name of the Customer: Date:

Project Name: Project ID:

Name of the Contractor: Location:

Drawing Ref. No.: Quantity:

1. Raft slab 2. Retaining wall 3. Toilet sunken 4. Terrace

CL : 04
Sl.No. Description YES NO NA
1 Whether approved / specified materials used as per
specification?
2 Check for surface preparation. Is it o.k.?

3 Check for Plastering before coating. Is it o.k.?


4 Check for coating of chemical. Is it o.k.?
5 Check for Plastering after coating. Is it o.k.?
6 Check for fixing of nozzles and spacing. Is it o.k.?

7 Check for grouting. Is it o.k.?

8 Check for brickbatcoba thickness & slopes.

9 Check for curing. Is it o.k.?

CORRECTIVE ACTION PROPOSED- Item wise.


If 'No' is marked, please specify reasons and thereafter corrective action proposed.
(Add additional sheets, if necessary)

Comments:
QUALITY CHECKLIST FOR SITE WORKS
EXTERNAL & PARTITION WALL/ RR MASONRY
ARCHITECTURAL STRUCTURAL INTERIOR SERVICES & UTILITY

1. Brick 2. Solid Block 3. Hollow Block 4. R . R 5. C. R

6. Aerocon Block 7. Gypsum 8. Wooden 10. Others


9. Glazed

Name of the Customer: Date:


Project Name: Project ID:
Name of the Contractor: Location:
Drawing Ref. No.: Quantity:

CL : 05
Sl.No. Description YES NO NA
Thickness
:

1 Check for ALIGNMENT & LOCATION of wall. Is it as per


drawing?
2 Check for placing reinforcement RC bands as per specification.

3 Check for MORTAR MIX PROPORTION is ok?


4 Check for SIZES OF OPENINGS for Doors & Windows? /
Any other sevices.
AC duct, Cable tray, chilled water pipe, etc.
INTERIOR - (PARTITION / WALL PANELLING FRAME WORK)
1 Type of Partitions/ Frame etc.,

Frame work materials used.


a) Aluminum frames

b) Timber frames

c) G.I /M.S frames

2 If it is wooden partition, check for Anti-termite/ wood borer


preventing treatment provided?
3 Height of Partition.
b) Half height
4 Whether the frame work sufficiently anchored in the floor & true
ceiling?
5 Check provisions made in the frame work for fixing conduits for
electrical, Data lines etc., as per drawings.
6 Check for approved make of finishing materials as per
specification.
CORRECTIVE ACTION PROPOSED- Item wise.
If 'No' is marked, please specify reasons and thereafter corrective action proposed.
(Add additional sheets, if necessary)
Comments:
QUALITY CHECKLIST FOR SITE WORKS
PLASTERING/ PAINTING
ARCHITECTURAL STRUCTURAL INTERIOR SERVICES & UTILITY

Name of the Customer: Date:

Project Name: Project ID:

Name of the Contractor: Location:

Drawing Ref. No.: Quantity:

CL : 06
Sl.No. Description YES NO NA
1 Check for COMPLETION OF PRECEDING ACTIVITIES like
fixing of service Conduits, Water Supply & sanitation lines, etc.

2 Whether chicken mesh, Corner beads used as per


specifications?
3 Check for MORTAR MIX PROPORTION & Check for Surface
of mortar mixing and addition of water profing compond if
required.
4 Check for THICKNESS & NUMBER OF COATS of Plaster and
required finish for further activities.

PAINTING
1 PRIOR TO PAINTING
Check whether approved make & shade are used?

DURING & AFTER PAINTING


1 Check for APPLICATION of paint. Is it uniform?

2 Check for Number of Coats.

CORRECTIVE ACTION PROPOSED- Item wise.


If 'No' is marked, please specify reasons and thereafter corrective action proposed.
(Add additional sheets, if necessary)
Comments:
QUALITY CHECKLIST FOR SITE WORKS

JOINERIES - (FIXING DOORS/ WINDOWS/ VENTILATOR)

ARCHITECTURAL STRUCTURAL INTERIOR SERVICES & UTILITY

Name of the Customer: Date:

Project Name: Project ID:

Name of the Contractor: Location:

Drawing Ref. No.: Quantity:

CL : 07
Sl.No. Description YES NO NA
1 Whether specified material and approved sample are used?

2 Check for the correct size of frames/ shutters as per drawing. Is


it o.k?
3 Check for the proper primer painting, powder coating, Anodizing
coating and other finishes to frames before fixing. Is it o.k.?
4 Check for fixing and grouting of frames with hold fasts. Is it
o.k.?
5 Check whether architrave is specified for door frames?

6 Check vision panel, door closers, floor spring, Access card ,


whether provision made.

7 Locks/ Latches
8 Handle

9 Weather stripping / Stoppers

CORRECTIVE ACTION PROPOSED- Item wise.


If 'No' is marked, please specify reasons and thereafter corrective action proposed.
(Add additional sheets, if necessary)
Comments:
QUALITY CHECKLIST FOR SITE WORKS
FLOORING/ DADOING
ARCHITECTURAL INTERIOR

FLOORING DADOING SKIRTING EXTERNAL CLADDING

Name of the Customer: Date:


Project Name: Project ID:
Name of the Contractor: Location:
Drawing Ref. No.: Quantity:

1. Ceramic tile 2. Vitrified tile 3. Marble 4. Granite

5. Cement based tile 6. Mosaic 7. Paver block 8. Others

CL : 08
Sl.No. Description YES NO NA
I Prior to Tiling:
1 Check for COMPLETION OF PRECEDING ACTIVITIES like
fixing of Door, Frames, Partitions, etc.
2 A. Check for Provision of Service Conduits, junction Boxes,
plumbing, etc.
3 Is the SAMPLE OF TILES approved?.

4 Check for MORTAR MIX/ ADHESIVE PROPORTION. Is it as


specified?
5 Check for THICKNESS OF MORTAR BED. Is it o.k?

6 Check for PATTERN OF LAYING. Is it ok?

7 Check for TOP LEVEL. Is it o.k?

LAYING PAVER BLOCKS

1 All pipe line/ Conduiting/ Sleeve work completed.

2 Check formation level ie. Bottom of sand bedding

3 Check thickness, shape, colour, pattern of paver blocks.

CORRECTIVE ACTION PROPOSED- Item wise.


If 'No' is marked, please specify reasons and thereafter corrective action proposed.
(Add additional sheets, if necessary)
Comments:
QUALITY CHECKLIST FOR SITE WORKS
INTERIOR (FALSECEILING)
ARCHITECTURAL STRUCTURA INTERIOR SERVICES & UTILITY

Name of the Customer: Date:

Project Name: Project ID:

Name of the Contractor: Location:

Drawing Ref. No.: Quantity:

CL : 09
Sl.N Description YES NO NA
o.
1 Check the type of falseceiling as per specification.
2 If it is Grid type, Check whether grids are marked as per
drawing so as to locate the service points.

3 Check whether the frame work and hanger rods are as per
specification.
4 Before fixing/ laying of boards check all service works such as
electrical, AC ducting, fire alarm, sprinkler, speakers, smoke
detector, heat detector, etc, Whether cutout/ opening provided.
5 Check for any cornices, trap door provision as per the drawing.

6 Check for painting of ceiling ( If it is board) - is it as per


specification.
CORRECTIVE ACTION PROPOSED- Item wise.
If 'No' is marked, please specify reasons and thereafter corrective action proposed.
(Add additional sheets, if necessary)
Comments:
QUALITY CHECKLIST FOR SITE WORKS
ROAD & DRAINS WORKS
SERVICES & UTILITY

Name of the Customer: Date:


Project Name: Project ID:
Name of the Contractor: Location:
Drawing Ref. No.: Quantity:

CL : 10
Sl.No. Description YES NO NA
PREPARATION OF SUBGRADE
1 PREPARATION OF SUBGRADE to specified lines and
Camber. Check for Cleaning and Making up of Soft spots &
other irregularities.
SAND - GRAVEL MIX FOR ROAD WORK.
1 Check the formation of subgrade with specified camber.

2 Check for spreading in layers as specified and watering has


been done on prior to the required proctor density to the
required compaction.
3 Check for finished surfaces, compacted thickness, camber,
gradient lines and slope. Are they acceptable?
W.B.M:
1 Check for proper grading of aggregates.

2 Check for Underground trenches / Hume pipes / Drain crossing /


road crossing LAYOUTS, GRADES & CROSS - SECTIONS OF
COMPACTED SUBGRADE prior to spreading of aggregates.

3 Check for UNIFORM SPREAD THICKNESS of Aggregates.

4 Check for DRY ROLLING, using proper road roller.

5 Check for WET ROLLING of Aggregates and COMPACTION.

6 Check for FINISHED SURFACES, COMPACTED THICKNESS,


CAMBER, LINES AND SLOPE.Are they acceptable?
ASPHALT/ BT FOR ROAD WORKS
2 Check Whether tack coat application is done properly.
3 Check for Uniform spread thickness of premix. Is it o.k.?
4 Check for finished surfaces,compacted thickness. gradient lines
and slope: Are they acceptable.
Drain work:
1 Marking layout line level of R.C.C drain.
2 Making R.C.C. drain all as per drawing in line, level & slope.
CORRECTIVE ACTION PROPOSED- Item wise.
If 'No' is marked, please specify reasons and thereafter corrective action proposed.
(Add additional sheets, if necessary)
Comments:
QUALITY CHECKLIST FOR SITE WORKS
INTERIOR - (FURNITURES/ STORAGE UNIT/ PARTITION/ PANELLING/ FURNISHING
WORKS)
ARCHITECTURAL STRUCTURAL INTERIOR SERVICES & UTILITY

Name of the Customer: Date:


Project Name: Project ID:
Name of the Contractor: Location:
Drawing Ref. No.: Quantity:

CL : 11
Sl.No. Description YES NO NA
1 Check the setting out is line with drawing/ layout

Check the provisions are made for such as pencil drawer, Key
2
board drawer, storage units attached with the table.
3 Check the type of finish :
a) Laminate
b) Veneer with melamine polish
c) ACP
Check the Approved make and thickness of materials as per
4
specifications and drawings.
INTERIOR (STORAGE UNIT)
1 Type of storage unit:
a) 750 mm Low height

b) 1200 mm height

c) 2100/ 2400 mm height

2 Check the Hardware such as lock, hinges, handles are provided


with as per specifications / drawings.
3 Check the plywood thickness, finishing of material whether with
Laminate or Veneer.
4 Check is it modular/ Custorm built.
1 Check type of internal frame work (work/ Aluminium box
sections)
2 Check type of partition (Fully solid/ Fully glazed/ combination of
glass and opaque)
3 Check before fixing of plywood electrical civil access, other
services consul
4 Check type of skirting.
5 Check location of switch boxes, is it ok?
INTERIOR (FURNISHING WORKS)
1 Check whether the carpet is of specified make colour and
shade.

2 Check whether chair is of specified make colour and shade.

3 Check the Fabric Pinup board.Is the fabric, colour, size of board
as per drawing / Specification.
4 Check about etching designs in glass partition.
CORRECTIVE ACTION PROPOSED- Item wise.
If 'No' is marked, please specify reasons and thereafter corrective action proposed.
(Add additional sheets, if necessary)
Comments:
QUALITY CHECKLIST FOR SITE WORKS
PLUMBING & SANITARY/ SANITARY FIXTURES
ARCHITECTURAL STRUCTURAL INTERIOR SERVICES & UTILITY

Name of the Customer: Date:


Project Name: Project ID:
Name of the Contractor: Location:
Drawing Ref. No.: Quantity:

CL : 12
Sl.No. Description YES NO NA
Water supply:
1 Check whether all pipe joints and method of jointing are done
as per specification and conforming to relevant IS codes and
standards.
2 Whether the samples of pipes and fittings are as per approved
specification?
3 Whether the concealed pipe lines are painted and protected as
per the specification?
4 Whether connected pipe lines and fittings are satisfactorily
tested for leaks before covering?
5 Ceiling suspended lines adequately supported by suitable dia of
rod/ anchor fastener with suitable spacing.
Sewer Line:
1 Check the approved pipes are used for the sewer lines. Is it
o.k.?
2 Check for the levels and alignment of sewer line as per drawing
/ specifications. Is it o.k.?

3 Check whether the jointing of pipes are as per specifications/


drawing. Is it o.k.?
4 Check whether for the inspection chambers are at the correct
location shape and to the correct invert level as per drawings/
5 specifications.
Whether leak tests conducted?

SANITARY FIXTURES & FITTINGS

1 Whether the fixtures are fixed in correct position and level as


per the drawings/ specifications?
Comments:
QUALITY CHECKLIST FOR SITE WORKS
ELECTRICAL INSTALLATION WORKS

SERVICES & UTILITY

Name of the Customer: Date:


Project Name: Project ID:

Name of the Contractor: Location:

Drawing Ref. No.: Quantity:

The following Indian Standard Codes are adopted for Installing the equipments at site

CL : 13
Sl. Description YES NO NA
No.
I.S No.
1 CODE OF PRACTICES

2 732/1989 - Code of Practice for Electrical wiring installation.

3 8884/1976 - Code of Practice for the installation of electric bell


and call system.
4 10028 Part 1 1985 - Code of Practice for selection installation
and maintenance of transformers Part 2 Installation.
5 10118 Part 3 1982 - Code of Practice for selection, installation
and maintenance of switchgear and control gear Part 3-
Installation.
6 5613 Part 2 Selection 1 1985 - Code of Practice for design
installation and maintenance of overhead power lines Part 2
lines upto and including 11KV section 1 Installation.
7 1255 (1983) - Code of Practice for Installation and Maintenance
of Power Cables upto and inlcuding 33 KV rating.
CORRECTIVE ACTION PROPOSED- Item wise.
If 'No' is marked, please specify reasons and thereafter corrective action proposed.
(Add additional sheets, if necessary)
Comments:

C.R. Narayana Rao


Architects & Engineers
Rev.1 dtd. 13.01.2006 1 of 1
QUALITY CHECKLIST FOR SITE WORKS

FABRICATION WORK

ARCHITECTURAL STRUCTURAL INTERIOR SERVICES & UTILITY

Name of the Customer: Date:


Project Name: Project ID:

Name of the Contractor: Location:

Drawing Ref. No.: Quantity:

CL : 14
Sl. No. Description YES NO NA
BEFORE FABRICATION:
Check for the following PRECEDING ACTIVITIES:
1 Check for the quality of materials / Test certificates of
materials submitted.
2 Approval obtained for the fabrication drawing
3 Check for the approved welding rods used
4 Check for fabrication material free from mud stains/ other
materials.
AFTER FABRICATION:
1 Material section used as per drawing.
2 Whether welding length as per drawing.
3 Whether all the interconnection section welded/ holes drilled
to assemble other members.
4 Fabricated material is ready for sand blasting
CORRECTIVE ACTION PROPOSED- Item wise.
If 'No' is marked, please specify reasons and thereafter corrective action proposed.
(Add additional sheets, if necessary)
Comments:

C.R. Narayana Rao


Architects & Engineers
Rev. 0 dtd. 13.01.2006 1 of 1

You might also like