NOTES

9Y12-10-150 T1 9Y12-05-150 T1
9Y12-11-150 T1 9Y12-04-150 B1 9Y12-06-150 B1 1. This drawing is to be read in conjunction
with all relevant architectural and
+1.65 +0.00 engineering drawings.

2. All dimensions are in millimetres unless


otherwise stated.

1200
16Y12-13-200 B2 3. All setting out dimensions are to be

(2)

(2)
4Y12-13 T2 verified on site prior to commencing
works.

4. Obtain all dimensions from shown figures.


10 9 8 7 6 5 4 3 2 1 5Y12-14-200 T2 + Do not scale off.
5Y12-14-200 B2
2600

200
5. All structural steelwork to be in accordance
with SABS 0162 : 1993 Parts 1 and 2
11 12 13 14 15 16 17 18 19 20
6. Steel grade to be 300WA

7. All welds to be 6mm continuous fillet welds


1200

to SABS 044 unless otherwise stated


15Y12-12-200 B2

(2)

(2)
4Y12-12 T2 8. All bolts to be Grade 8.8

9. All reinforcement to be inspected by the


+3.30 Engineer prior to pouring concrete.

200 1000 300 300 300 300 300 300 300 300 300 1400 9Y12-09-150 T1 9Y12-07-150 T1 9Y12-08-150 T1 10. All Reinforced Concrete works to be done
5300 9Y12-03-150 B1 9Y12-02-150 B1 9Y12-01-150 B1 in accordance with the Engineer's
specifications on structural concrete.

11. All Reinforced Concrete works to be done

STAIRCASE PLAN G.A STAIRCASE PLAN REINF. In accordance with Eurocode 2

12. All concrete to be class 30 with a


cube crushing strength of 30N/mm2
at 28 days unless otherwise stated.

13. Cover to reinforcement to be 30mm.


Unless stated otherwise.

14. Maximum aggregate size to be 20mm.

1200 2700 1400 9Y12-05-150


9Y12-16 -150
(2)

175
10 No. RISERS @165mm EACH

1055

9Y12-06-150
3
12-1
4Y
1650

-200
2-13
Y1
16
(2)
9Y12-11-150
9Y12-04-150

A
5Y12-14-200

D
(2) 9Y12-02-150

SC 133
B
3125
175

9Y12-10-150

C
5Y12-14-200
10 No. RISERS @165mm EACH

9Y12-03-150 4Y
12
-12

9Y12-09-150
1475

WAIST 175mm 15
Y1
2-1
9Y12-02-150 2-2
00
(2)
9Y12-01-150
9Y12-08-150
Y16
130

Y16
100

100

9Y12-07-150
200 2965 135 600 135 1265 9Y8-15-150
Y16

STAIRCASE ELEVATION G.A STAIRCASE ELEVATION REINF.

No BARS TOTAL BENDING


MEMBER PER DIA. LENGTH NUM- MARK S C
OF MEMB BER A B C D E/r

1 9 Y12 2300 9 01 45 640 1540 (130) 310


27 Y12 3950 27 02 62 3420 1650 (540)
9 Y12 1700 9 03 133 540 1050 (130) 260
9 Y12 4650 9 04 45 3320 1200 (130) 1600
9 Y12 1850 9 05 45 900 830 (130) 435
9 Y12 1900 9 06 133 540 1250 (130) 260
9 Y12 1400 9 07 62 860 410 (540)
9 Y12 2250 9 08 133 540 1600 (130) 260
9 Y12 2000 9 09 45 1020 850 (130) 490
9 Y12 1550 9 10 62 1020 490 (540)
9 Y12 2050 9 11 133 540 1400 (130) 260
19 Y12 1150 19 12 20 (1140)
20 Y12 1150 20 13 20 (1140)
10 Y12 2550 10 14 20 (2540)
9 Y8 1950 9 15 60 350 540
9 Y12 2100 9 16 45 900 1070 (130) 435

8 10 12 16 20 25 32 40 TOT Date
R Det. by
Y 7 347 354 Ref Dwg
STAIRCASE
TOT 7 347 354 Job No
STAIRCASE PLAN & ELEVATION
Revision G.A /REINFORCEMENT
ST-04
Schedule No

You might also like