Professional Documents
Culture Documents
RG-S6100 Series Multi-GE Switches 20231121
RG-S6100 Series Multi-GE Switches 20231121
Multi-GE Switches
Scan QR Code
For More Enquiry
Product Pictures
RG-S6110-24MG4VS-UP
RG-S6110-48MG4VS2QXS-UP
RG-S6120-24XMG4XS4VS-UP-H
RG-S6120-48XMG4VS2QXS-UP-H
Product Overview
RG-S6100 series switches are next-generation multi-GE switches developed by Ruijie. With an advanced
hardware architecture and Ruijie modular operating system, the RG-S6100 delivers fast hardware processing
and good operation experience. They lay a foundation for high-performance networks that support IoT service
lifecycle management, mobility applications, and cloud applications.
The RG-S6100 offers flexible multi-GE access (10GE/5GE/2.5GE/1GE) and high-performance 10GE/40GE uplink
ports, catering for demands of high-density access and high-performance aggregation. It provides high-power
PoE++ power with a maximum of 90 W PoE output to cope with power needs of different terminals.
-01-
Product Highlights
Supports a variety of port types, including 100M/1000M/ redundancy and avoiding switch startup failures
2.5G/5G Base-T and 100M/1000M/2.5G/5G/10G Base-T caused by flash chip failures.
auto-negotiation Ethernet ports, to better adapt to Wi-Fi 7 Uses RGOS modular operating system to provide
access points (APs). more entries, faster hardware processing, and better
Provides high-power PoE++ power supply with a operation experience.
maximum of 90 W PoE output to cope with power Provides open and programmable RGOS modular
needs of different terminals, meeting demands for operating system. Basic functions are incorporated into
high bandwidth in large campuses. the main version, and custom functions are released in
Supports multiple PoE allocation modes, achieving app mode, ensuring stability of the basic functions.
more efficient power management and energy saving. Supports the x86 platform, which supports containers,
Supports VSU, delivering flexible networking and high allows third-party management applications to be
performance. installed, and makes it easy for customizing functions.
Intelligently adjusts the fan speed and supports Rectifies faults related to processes online in seconds,
automatic port sleeping, saving energy and reducing without interrupting network operation.
noise. Supports Python that allows applications across platforms.
Provides multiple network management methods, Supports high-speed access to northbound interfaces,
achieving simple and easy network maintenance. with the performance of up to thousands of operations.
Offers hardware-level protection, ensuring continuous It can associate with the controller to upgrade the man-
device operation and nonstop services. machine interface to machine-machine interface.
Uses two flash chips to store BOOT software (system Upgrades and extends functions online to ensure
boot program), achieving hardware-level BOOT nonstop services.
Product Features
Multi-GE Access standards. However, if the power exceeds 30 W, users
are unable to use PoE for power supply, opting instead
In recent years, Ethernet interface standards have rapidly for mains-powered cables or even high-voltage power
evolved from 10BASE-T and 100BASE-T to 1000BASE-T (IEEE deployment. This presents significant challenges related
802.3ab), leading to widespread adoption across devices to deployment costs and timelines, maintenance, and
such as PCs and APs. However, as the Wi-Fi 6 technology security. By adhering to the IEEE802.3bt standard, the RG-
has been introduced, APs can now deliver uplink rates of S6100 offers high-power PoE power supply capabilities
10 Gbps, which poses a growing challenge for GE network and achieves a maximum PoE output of 90 W through a
devices. The RG-S6100 addresses this issue by offering single Ethernet port, providing a significantly improved
100M/1000M/2.5G/5G Base-T and 100M/1000M/2.5G/5G/10G user experience.
Base-T Ethernet ports in auto-negotiation mode, providing
better adaptability to Wi-Fi 6 APs. IPv4/IPv6 Dual-Stack Multi-Layer Switching
High-Power PoE Power Supply The RG-S6100 hardware supports both IPv4 and IPv6 dual
stacks, as well as multi-layer line-rate switching in order
Previously, PoE remote power supply scenarios only to differentiate and process packets of each protocol
have access to PoE (IEEE 802.3af) and PoE+ (IEEE 802.3at) effectively. With flexible IPv6 network communication
-02-
solutions, the RG-S6100 can meet various IPv6 network as DoS attack defense, IP scanning attack defense, validity
demands such as planning or maintenance. The RG-S6100 check of ARP packets, and multiple hardware-based ACLs.
supports a wide range of IPv4 routing protocols, covering The hardware-based IPv6 ACL can easily control the access
IPv4 static routing, RIP, OSPFv2, IS-ISv4, and BGP4. Fitting of IPv6 users at the network edge even if there are IPv6
for different network environments, one can select users on an IPv4 network. The RG-S6100 allows IPv4 and
appropriate routing protocols for flexible network building. IPv6 users to coexist and can control access permissions
Additionally, the RG-S6100 also supports abundant IPv6 of IPv6 users, for example, restricting access to sensitive
routing protocols such as IPv6 static routing, RIPng, resources on the network.
OSPFv3, IS-ISv6, and BGP4+. These protocols can be The RG-S6100 provides a unique hardware CPU protection
flexibly selected to either upgrade an existing network to mechanism: CPU Protection Policy (CPP). CPP enables the
IPv6 or establish a new one. RG-S6100 to classify data traffic sent to the CPU, process the
traffic by queue priority, and apply the rate limit to traffic as
VSU required. CPP fully protects the CPU from being occupied
by unauthorized traffic, malicious attacks, and resource
The RG-S6100 supports Virtual Switching Unit (VSU). VSU consumption, which ensures the security of the CPU and the
enables multiple physical devices to be connected through switch.
aggregate links and virtualized into one logical device. The RG-S6100 and its ports can be flexibly bound to a
By using the same IP address, Telnet process, and CLI for user’s IP address and MAC address, which strictly restricts
management, along with automatic version check and the access of users connected to the ports or the switch.
configuration, network administrators can manage just DHCP snooping enables the RG-S6100 to receive DHCP
one logical device, thereby enhancing work efficiency. Response messages only from trusted ports, preventing
spoofing from unauthorized DHCP servers. With DHCP
Simplified management: The network administrator can snooping, the RG-S6100 dynamically monitors ARP packets,
manage multiple switches uniformly because there is no checks users’ IP addresses, and discards unauthorized
need to connect separately to each switch for configuring packets that do not match binding entries. This effectively
and managing them. prevents ARP spoofing and source IP address spoofing.
The RG-S6100 also supports access control through source
Simplified network topology: A VSU serves as a switch within a IP address-based Telnet, which can prevent unauthorized
network and eliminates Layer 2 loops and MSTP configurations users and hackers from maliciously attacking and
by connecting peripheral devices through aggregate links. controlling the switch, and enhance the network
Various control protocols can run on the VSU. management security of the switch.
Through the Secure Shell (SSH) and Simple Network
Fault rectification within milliseconds: A VSU connects Management Protocol version 3 (SNMPv3), the RG-S6100
to peripheral devices through aggregate links. If a fault occurs can encrypt management information in Telnet and
on one device or member link in the VSU, data and services can SNMP processes. This ensures information security of
be switched to another member link within 30 ms. management devices and prevents hackers from attacking
and controlling the devices.
High scalability: Devices can be added to or removed The RG-S6100 rejects unauthorized network access and
from a virtualized network, without affecting normal enables authorized network access by employing multi-
operation of other devices. element binding, port security, time-based ACL, and data
stream-based rate limiting. It can strictly control user
Sound Security Protection Policies access to enterprise networks and campus networks and
restrict the communication of unauthorized users.
The RG-S6100 can effectively defend against virus spread and The RG-S6100 supports the Network Foundation Protection
hacker attacks through multiple inherent mechanisms, such Policy (NFPP) to enhance its security. By isolating attack
-03-
sources, NFPP can protect the processor and channel snooping, IGMP, Multicast Listener Discovery (MLD),
bandwidth resources of the switch. This ensures normal Protocol Independent Multicast (PIM), PIM for IPv6, and
packet forwarding and protocol status. Multicast Source Discovery Protocol (MSDP). It provides
multicast service support for IPv4 networks, IPv6 networks,
-04-
Product Specifications
Hardware Specifications
Interface Specifications
48 x 100M/1000M/
48 x 100M/1000M/
24 x 100M/1000M/ 2.5GE/5GE electrical 24 x 100M/1000M/
2.5GE/5GE/10GE
2.5GE/5GE electrical ports with auto- 2.5GE/5GE/10GE
electrical ports with
ports with auto- negotiation electrical ports with
auto-negotiation
negotiation 4 x 10GE/25GE SFP28 + auto-negotiation
4 x 10GE/25GE SFP28 +
4 x 10GE/25GE SFP28 2 x 40GE QSFP+ ports 4 x 10GE SFP+ ports 4 x
2 x 40GE QSFP+ ports
ports Ports 1 to 48 support 25GE SFP28 ports
Fixed port Ports 1 to 48 support
Ports 1 to 24 support PoE/PoE+ power Ports 1 to 24 support
PoE/PoE+ power supply
PoE/PoE+ and supply (ports 1 to 24 PoE/PoE+ and
(ports 1 to 24 support
HPoE power supply support HPoE power HPoE power supply
HPoE power supply,
(maximum output supply, maximum (maximum output
maximum output power
power of a HPoE- output power of a power of a HPoE-
of a HPoE-capable port:
capable port: 90 W) HPoE-capable port: 90 capable port: 90 W)
90 W)
W)
2 x fixed fan modules 3 x fan module slots 3 x fan module slots 3 x fan module slots
Fan module Fan speed regulating Fan speed regulating Fan speed regulating Fan speed regulating
and fault alarms and fault alarms and fault alarms and fault alarms
1 x built-in power
Power module 2 x power module slots 2 x power module slots 2 x power module slots
module
Fixed management
1 x MGMT port, 1 x console port, and 1 x USB2.0 port
port
System Specifications
Packet forwarding
327 Mpps 625 Mpps 565 Mpps 982 Mpps
rate
System switching
440 Gbps 840 Gbps 760 Gbps 1320 Gbps
capacity
Number of global
Number of global MAC Number of global MAC Number of global MAC
MAC addresses:
Number of MAC addresses: 32,768 addresses: 32,768 addresses: 32,768
32,768
addresses Number of static MAC Number of static MAC Number of static MAC
Number of static MAC
addresses: 1,000 addresses: 1,000 addresses: 1,000
addresses: 1,000
Number of IPv4
16,000 16,000 16,000 16,000
unicast routes
-05-
Hardware RG-S6110- RG-S6110- RG-S6120- RG-S6120-
Specifications 24MG4VS-UP 48MG4VS2QXS-UP 24XMG4XS4VS-UP-H 48XMG4VS2QXS-UP-H
Number of IPv4
4,000 4,000 4,000 4,000
multicast routes
Number of IPv6
16,000 16,000 16,000 16,000
unicast routes
Number of IPv6
2,000 2,000 2,000 2,000
multicast routes
Number of IGMP
4,000
groups
Number of MLD
1,000
groups
Ingress: 2,500
Number of ACEs
Egress: 1,000
Number of VSU
2 2 2 2
members
1.2 GHz single-core 1.2 GHz single-core 1.2 GHz single-core 1.2 GHz single-core
CPU
processor processor processor processor
Maximum power Without PoE: < 120 W Without PoE: < 240 W Without PoE: < 120 W Without PoE: < 240 W
consumption Full PoE load: < 370 W Full PoE load: < 1,600 W Full PoE load: < 1,650 W Full PoE load: < 1,600 W
-06-
Hardware RG-S6110- RG-S6110- RG-S6120- RG-S6120-
Specifications 24MG4VS-UP 48MG4VS2QXS-UP 24XMG4XS4VS-UP-H 48XMG4VS2QXS-UP-H
RG-PA600I-P-F:
AC input: 100 V AC to 240 V AC
AC input: 100 V AC to
Frequency: 50/60 Hz
240 V AC
Rated current per circuit: 8 A
Rated input voltage Frequency: 50/60 Hz
RG-PA1000I-P-F:
Rated current per
AC input: 100 V AC to 240 V AC
circuit: 6 A
Frequency: 50/60 Hz
Rated current per circuit: 8 A
Maximum input
90 V AC to 264 V AC
voltage
Operating
0°C to 45°C (32°F to 113°F)
temperature
Storage
–40°C to +70°C (–40°F to +158°F)
temperature
Typical value: < 40 Typical value: < 60 Typical value: < 60 Typical value: < 60
dBA@27°C (80.6°F) dBA@27°C (80.6°F) dBA@27°C (80.6°F) dBA@27°C (80.6°F)
Operating noise
Maximum value < 78 Maximum value < 78 Maximum value < 78 Maximum value < 78
dBA dBA dBA dBA
Interface surge
6 kV
protection
Software Specifications
RG-S6100 Series
Feature Description
-07-
RG-S6100 Series
Feature Description
Voice VLAN
STP (IEEE 802.1.d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)
ERPS (G.8032)
LLDP/LLDP-MED
IP service DNS
Static routing
GR
-08-
RG-S6100 Series
Feature Description
IPv4/IPv6 VRF
IPv4/IPv6 PBR
IGMPv1/v2/v3 snooping
MLD snooping
MSDP
PIM-SMv6
Multicast querier
ACL and QoS Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers)
Extended MAC ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and
optional Ethernet type)
-09-
RG-S6100 Series
Feature Description
Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC
address, IP address, TCP/UDP port number, protocol type, and time range)
Time-based ACLs
Applying ACLs globally (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type,
MAC address, IP address, TCP/UDP port number, protocol type, and time range)
ACL redirection
Congestion management: SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ
Multi-AAA
IEEE802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC
address-based 802.1X authentication
-10-
RG-S6100 Series
Feature Description
Web authentication
ICMPv6
Port security
Security
IP source guard
SAVI
Various attack defense functions including NFPP, ARP anti-spoofing, DHCP/DHCPv6 attack defense, ICMP
attack defense, ND attack defense, IP scanning attack defense, and customizing attack defense packet types
REUP
ERPS (G.8032)
Rapid Link Detection Protocol (RLDP), Layer 2 link connectivity detection, unidirectional link detection,
and VLAN-based loop control
BFD
Hot swapping of power modules and fan modules (not supported by the RG-S6110-24MG4VS-UP)
-11-
RG-S6100 Series
Feature Description
Device
VSU
virtualization
sFlow
SNMP v1/v2/c3
RMON (1, 2, 3, 9)
Various types of RMON groups, including event groups, alarm groups, history groups, and statistics
groups, as well as private alarm extension groups
RMON used to implement Ethernet statistics, historical statistics, and alarm functions
NMS and
NETCONF
maintenance
CWMP
gRPC
CLI (Telnet/console), SSH, Syslog, SNMP over IPv6, Telnet v6, FTP/TFTP v6, DNS v6, and NTP for IPv6
Note: The item marked with the asterisk (*) will be available in the future.
-12-
Protocol Compliance
RG-S6100 Series
-13-
RG-S6100 Series
-14-
Typical Applications
RG-S6100 series switches can be deployed at the access layer of a large-scale enterprise campus network to serve as
the PSE for high-power APs.
RG-S6100 series switches provide abundant security management mechanisms to achieve robust network security
defense and highly secure network access control.
RG-S6100 series switches adopt sound management policies for bandwidth management to guarantee the
bandwidth required by voice, multicast audio and video services, video on demand (VoD), and other key services.
Scenario 1
RG-S6100 series switches can be deployed at the access or aggregation layer of a small- and medium-scale campus
network. The 2.5GE/5GE/10GE Ethernet ports of the RG-S6100 can serve as member ports of a high-speed aggregate
interface to achieve the link bandwidth of 10 Gbps or 25 Gbps at the aggregation layer and that of the 40 Gbps or 100
Gbps at the core layer. This meets the increasing needs for high-performance bandwidth.
Server farm
Legend
40G/100G
40G/100G optical fiber
RG-N18000-E 10G
10G optical fiber
2.5G
Multi-rate twisted pair
1000M
1000M optical pair
RG-S6150-X RG-S6150-X
1000M
1000M twisted pair
Ordering Guide
Follow the steps to order an RG-S6100 multi-GE switch:
Select a model of RG-S6100 series switches. The device is fully equipped with fan modules that do not need to be
purchased separately.
Select power modules based on switch models. At least one power module is required.
Select optical modules based on optical interfaces of the switch.
Models marked with asterisks (*) in Ordering Information will be available in the future.
-15-
Ordering Information
The switch, expansion module, power module, and other components can be ordered as needed. Before ordering an expansion
module or power module, contact the online customer service personnel for the latest support information about the module.
Model Description
GE Optical Module
Model Description
GE-SFP-LX20-SM1310-
SFP BIDI Transceiver-TX1310/RX1550, 20 km, LC
BIDI
GE-SFP-LX20-SM1550-
SFP BIDI Transceiver-TX1550/RX1310, 20 km, LC
BIDI
-16-
Model Description
GE-SFP-LH40-SM1310-
SFP BIDI Transceiver-TX1310/RX1550, 40 km, LC
BIDI
GE-SFP-LH40-SM1550-
SFP BIDI Transceiver-TX1550/RX1310, 40 km, LC
BIDI
Model Description
10GE LC connector module with a link length of up to 40 km, 1310-nm wavelength, applicable
XG-SFP-LR-SM1310
to the SFP+ port
10GE LC connector module with a link length of up to 40 km, 1550-nm wavelength, applicable
XG-SFP-ER-SM1550
to the SFP+ port
XG-SFP-AOC1M 10GE SFP+ port cable, 1 m, including one cable and two interface modules
XG-SFP-AOC3M 10GE SFP+ port cable, 3 m, including one cable and two interface modules
XG-SFP-AOC5M 10GE SFP+ port cable, 5 m, including one cable and two interface modules
Model Description
-17-
40GE Optical Modules
Model Description
40GE LR4, QSFP+ transceiver, LC, 1310-nm wavelength, 2-core, 10 km over SMF, applicable to
40G-QSFP-LR4 SM1310
QSFP+ ports
40G-AOC-5M 40GE QSFP+ active optical cable, 5 m, including one cable and two interface modules
40G-AOC-10M 40GE QSFP+ active optical cable, 10 m, including one cable and two interface modules
Warranty
For more information about warranty terms and period, contact your local sales agency:
Warranty terms: https://www.ruijienetworks.com/support/servicepolicy
Warranty period: https://www.ruijienetworks.com/support/service_41
Note: The warranty terms are subject to the terms of different countries and distributors.
More Information
For more information about Ruijie Networks, visit the official Ruijie website or contact your local sales agency:
Ruijie Networks official website: https://www.ruijienetworks.com/
Online support: https://www.ruijienetworks.com/support
Hotline support: https://www.ruijienetworks.com/support/hotline
Email support: service_rj@ruijienetworks.com
-18-