The easi-edge difference
We design, fabricate, manage and hire products And what’s more, we also offer a simple
to provide practical industry leading solutions pricing system where we provide a quote
to all your working at height issues. with no hidden extras once the project
easi-edge products are designed to conform to has begun.
Working at Height Regulations 2005 and the Our dedicated sales managers can take your
British and European standard for temporary preliminary drawings or 3D model, propose
edge protection BS EN 13374. and detail a scheme for site safety that can
We are founding members of the Edge be easily incorporated during the fabrication
Protection Federation (EPF) and our mission and erection or general construction process.
is to make working at height safe for all The easi-edge team will coordinate all
site operatives. deliveries to your site to suit project phases,
Our commitment to excellence through with continuous on-site support provided
both superior product service is unparalleled. by experienced field engineers whose
All products are designed by chartered qualifications include CSCS certification
structural engineers and are rigorously tested. and Train the Trainer certificates.
Our experienced people are able to offer you
advice on solutions to your working at height
issues. We underpin our commitment through
ISO 9001, 14001 and OHAS 18001.
OVERVIEW
BOLT-ON SACRIFICIAL CLAMP-ON STAIRS
BOLT-ON STUB SACRIFICIAL SOCKET CLAMP-ON SURFACE MOUNTED
‘L’ BRACKET SOCKET
UB/UC SECTIONS
PFC SECTIONS
SHS/RHS SECTIONS
CHS SECTIONS
COLD FORMED
SECTIONS
PRE-CAST CONCRETE
STRUCTURAL TIMBER
Centre of column
100
22 dia
Shown here are the clearance forms Barriers initially set on lower hook to
provide final clearance for finished
for each type of system, these are to slab (as shown). It can be moved to
be completed by the customer, so the upper hook to provide an extra
that we know the specific positioning 100mm clearance (if required).
1050 o/barrier
requirements for each project.
The general standard is to set the
system with 20mm clearance in
STRUCTURAL
TOPPING
Depth of slab/screed/trim
Depth of slab/screed/trim
Sockets are typically on centre line &
socket length is at least as deep as slab
(to avoid posts being cast into floor).
100
1050mm o/barrier
1050mm o/barrier
1050mm
19
00
1050mm
mm 70
22 (M 0m
57
mm ax P 10 m
(M
Ov os 57 ax
era t Ctrs mm Pos
ll l ) Ov tC
eng era trs
th ll l )
eng
th
12 30
00 0m
15 mm 65 m
57 ( (M
mm Max 7m ax
Pos m Pos
Ov Ov tC
era tC era trs
ll l tr ll l )
eng s) eng
th th
The unique single bolt fixing solution helps reduce the exposure
to working at height.
The bolted assembly with both horizontal and vertical adjustment
facility is pre-detailed and delivered to site indexed to suit the floor
slab detail.
STANDARD STUB
0
30 40
0
Post
1070mm
Boot
Stub
0
20
0 20
E-00800 E-00810
200mm spacer 200mm spacer
(5.8kg) (2.65kg)
0
40
0
40
500mm to
underside
of panel
mm
00
10
UC/UB
Up to 178 UB or 152 UC
PFC
SHS
Centre of column
Split equal Split equal Split equal Split equal
(1900 Max.) 50 (1900 Max.) (1900 Max.) (1900 Max.)
100
22 dia
Outside of build
site set to suit the relevant floor slab thickness and overhang.
Inside of build
• The face of the top hook is colour coded.
• With each delivery of components, a colour coded drawing
will be provided showing which colour of Post assembly is
to be fixed to which beam.
• The unique ‘single bolt fixing’ system allows for quick and
easy installation and removal. STAGE 2
• The Post assemblies should be installed using M20x60
bolts supplied.
• The Post hooks should always face into the building.
• With the Posts in position, barrier panels should be applied,
initially set with on lower hook to provide final clearance for
finished slab.
• Barrier panels should overlap adjacent barriers by at least STAGE 3
one aperture at each Post where possible.
• Secure the barriers to the Post, the cable ties provided are
to be fitted as a visual aid for inspection
• The section can now be craned into position.
• Use two number pipe clamps to secure the barriers top
and bottom on all external and internal corners
Adjustment of the System STAGE 4
The following adjustment can be made on site:
• The barriers can be lifted by 100mm vertically if required,
by using lower handrail in the first hook to give a working
clearance gap under the barriers for edge trim installation,
slab floating etc.
• Utilising the indexing holes and pins provided, the system
can be adjusted both horizontally & vertically.
1070mm
425mm
standard Post
150
mm
150
mm
847mm
clearance to
underside
barrier
PRE-CAST
DECKING DECKING PLANK
Socket on centre of beam Socket at internal edge of beam Socket at internal edge of beam
Standard position Modified position to avoid cross bracing Modified position to avoid pre-cast planks
Centre of column
Centre of column
‘L’ BRACKET
525mm
765mm
925mm
m m
0m 0m m
50 74 0m
74
E-01100 500 ‘L’ bracket (6.3kg) E-01150 740 ‘L’ bracket (7.85kg) E-01175 900 ‘L’ bracket (8.4kg)
standard
Post
‘L’ bracket
TYPICAL POST DRESSED WITH Extra items available within the system.
BARRIERS (SHOWING OVERLAPS)
15
POST EXTENSION
0m
m
15
0m
m
744mm
940mm
STAGE 3
column
Column
Column
Center ofof
Center ofof
Centre
Centre
300 approx.
300 Approx. 300300
approx.
Approx.
EXTERNAL CORNER
External / internal corner – 300mm from the joint,
these may need adjusting to avoid a clash.
• Use two number pipe clamps to secure the barriers
top and bottom on all external and internal corners.
Adjustment of the system
The following adjustment can be made on site:
• The barriers can be raised by 100mm by transferring
the lower handrail to the upper of the top two hooks. INTERNAL CORNER
This system can be used to strike the barriers internal to the build
once the slab is cast, the barriers could have previously been on
bolt-on Stubs (depending on build conditions).
1070mm
Post
surface 19
mounted 00
mm
socket (M
ax
Ctr
s)
E-00500
standard Boot
500mm
(3.2kg)
1070mm
0
30 E-00550
650mm
extended Boot
(3.85kg)
standard Post
18
0m m 19
m 0m standard Boot 00
14 mm
(M
ax
fixing adapter Ctr
s)
KW-01-M05 plate
300mm Stub
Fixing adapter plate (2.22kg)
500mm
0
30
18
0m m
m 0m
14
E-00400 standard Post (3.6kg) KW-01-M05 wood fixing adapter plate (2.22kg)
Post
Boot
19
00
mm
(M
Stub wood fixing ax
Ctr
adapter plate s)
1070mm
18
0m m
m 0m
14
Post
surface socket 19
00
mm
(M
ax
wood fixing Ctr
adapter plate s)
500mm
0
30
150mm
Post
Boot
19
00
mm
wood fixing (M
Stub ax
right angle Ctr
adapter plate s)
1090mm
E-03450 surface mounted Post socket (2.4kg) E-00450 stair Post (3.5kg)
standard
Post
surface
mounted
post
250 mm typ.
3/4
1/4 1/2 3/4
1352 mm
1183 mm
1014 mm
mm
845 mm
m mm mm 12
7m 09 11 21
0 15 18
12
1000 mm 1250 mm 1500 mm 1750 mm
5 Risers 6 Risers 7 Risers 8 Risers
1/2
F
F 3/4
1690 mm
1521 mm
1521 mm
mm mm mm
14 14 16
24 24 27
3/4
3/4
F F
2028 mm
1859 mm
mm mm
18 19
30 33
2500 mm 2750 mm
11 Risers 12 Risers
F
F
F F
2366 mm
2197 mm
mm mm
21 23
36 39
3000 mm 3250 mm
13 Risers 14 Risers
100mm
100mm
100mm
100mm
250mm
= =
40 100 Typ 100 Typ 40 100 Typ 100 Typ
140 140
o/Stairs o/Stairs
FLOOR STAND
22
57
mm
ove
ral
l len
gth
ove 1057
ral mm
l le
ngt
h
E-H0100 E-H0250
Full barrier (22kg) Quarter barrier (8.7kg)