KATEGORI ALAT KESEHATAN : Ultrasonic Pulsed Doppler Imaging System

SOLE AGENT/ DISTRIBUTOR : PT. FUJIFILM Indonesia


MODEL / TYPE : ARIETTA 650
CLINICAL APPLICATION : RADIOLOGY/OBGYN
PRODUCT NAME : ARIETTA 650 ULTRASOUND SYSTEM WITH 3 PROBE

SPECIFICATION for "ARIETTA 650 ULTRASOUND SYSTEM WITH 3 PROBE"


PACKAGE Include:
Convex Probe / Linear Probe Choice of (Convex Probe or Linear Probe)
Transvaginal Probe / Linear Probe / Convex Probe Choice of (Transvaginal Probe, OB/GYN or Linear Probe or Convex Probe)
4D Probe / Intraoperative Probe / Transvaginal Probe
Choice of (OB Fetal, 4D Probe or Intraoperative Probe or Transvaginal Probe)
Hardware 3D Unit option available for selection
Software BASIC SOFTWARE
Software DICOM NETWORK
Software 4D shading option available for selection
Software Panoramic View software
Software IMT Measurement
Software Real-Time Elastography option available for selection
Software Shear Wave Measurement option available for selection
Warranty 2 Year
Training On site training
Accessories Included UPS & Color Printer or BW Printer

Operating Modes ・ B-mode


・ M-mode
・ D: Spectral Doppler mode (PW, CW, HPRF-PW)
・ Dual Gate Doppler mode
・ Flow mode
・ Power Flow mode (Directional Power Flow)
・ eFLOW mode (Directional eFLOW)

Image Display Modes 2D/ B Mode/ Dual B/D/ M/PW/Trapezoidal/ DSM. CW/3D/4D are optional

Beam former
Transmission CPWG (Compound Pulse Wave Generator)
Programmable waveform transmission
Chirp wave transmission
Reception Multi processing high-speed digital beam former

Transmission/Reception method of Harmonics Reception frequency: 1.0-18.0 MHz


Transmission/Reception method of pulse modulation – Chirp Pulse modulation
Compound Broadband Pulse transmission
Tissue Adaptive Technology Sound velocity adjustment: 26 steps
Automated sound velocity adjustment
Focusing Reception: PixelFocus, Broad Focusing/ Adjustable Focus

Frame rate High Frame rate

B-mode Display Gray Scale: 256 levels


Scanning area: 100% to 25%, 1 degree step
Zoom
HI zoom (real-time image): PAN zoom (real time and frozen image): Depth range selections:

Gain*: 80 dB range
Weak-signal enhancement: On/Off
TGC (time gain control) : Virtual
Dynamic range: 40-90 dB
Receiving filter – Spatial resolution and deeper area penetration can be changed
View gamma: 4types
Spatial Compound Imaging
Trapezoidal scan

Image without degradation of spatial resolution.


Adaptive Imaging: HI REZ function 8 steps
Auto-optimizer (Optimization of gain, sound velocity adjustment)

M-mode Sweep method: Moving bar


Sweep speed: 300
Gain: B-gain ±30 dB
Dynamic Range: 40 dB-90 dB
AGC: 4 steps FAM (Free Angular M-mode)
Auto-optimizer (Optimization of gain)

Spectral Doppler Display: Power spectrum


Real-time Doppler Auto Trace
Doppler methods:
– PW (Pulsed Wave) Doppler
– HPRF (High Pulse Repetition Frequency) PW Doppler
– Dual Gate Doppler
– CW (Continuous Wave) Doppler (Optional)
Doppler gain: 60dB variable, adjustable in real-time and frozen.
Dynamic Range: 40-90dB 1dB steps (changeable after freezing)
Black-and-white inversion: changeable after freezing
Auto-Optimizer(Optimization of gain, velocity range and baseline shift )
CW auto noise reduction
Adaptive Noise Rejection)

Color Flow Mapping Color area size: Variable from 100% to 25% continuously
Steered linear scanning:
Max. ±30 degrees *, changeable at 5 degrees interval * Probe dependent
Line density: Up to 8 steps
Auto-Optimizer (Optimization of gain)

PowerFlow – Display patterns: PowerFlow, Directional PowerFlow

eFLOW – Display patterns: eFLOW, Directional eFLOW


– Advanced wall motion reduction

TDI (Tissue Doppler Imaging) Yes, optional

Cine Memory Cine search and loop display (in B mode):


Capacity B mode: Max. 78,835 frames.
M and D modes: Max. approx. 900 seconds.

Data Management
Format DICOM Optional/ (Raw, MJPEG) (Non-compressed, RLE, RGB(Plane/Pixel), JPEG)

Image acquisition mode


Cine loop high-speed data transfer (Raw, Image):
It is possible to selectively store data of arbitrary section
in the Cine Memory.
Simultaneous output to multiple media:
It is possible to output still image data to multiple of storage media
include network and printers at the touch of a button.

Measurement data It is possible to store measurement data in the main unit hard disk

Data storage media ・ Main unit hard disk


500 GB HDD (Image Storage) & 128 GB SSD (Run OS and Software)
・ USB memory
・ USB HDD
・ CD-R
・ DVD-RAM
・ Network interface(DICOM format): 10 BASE/T or 100 BASE/TX, (automatically switched)

DICOM network communication*1 DICOM Print/Storage/MWM

Measurements and Analysis


Basic measurements
On B-mode image Yes - All
On M-mode image Yes - All
On spectral Doppler Yes - All
On B/D mode Yes - All
Application measurements
Obstetrical measurements & calculations Yes
Gynecological measurements & calculations Yes

Small parts measurements & calculations Yes- All General measurements availible
Abdominal measurements & calculations Yes- All General measurements availible
Report Functions Yes- SR (basic)
Hot Key function Yes
Measurements on VCR playback image Possible (manual calibration)
User’s calculation 30 equations can be set for each application
User-assignable terms: 60 words possible
Font size of measurement result Yes- Adjustable
Preset Function 100 kinds

Characters and graphic displays Annotation & Body Marks


Menu control 10.1-inch color TFT LCD touch panel
Active Probe Port For electronic scanning probes: 4 active
Input/Output Signals Yes
Viewing Monitor ・ 21.5-inch LCD display
・ Tilt and swivel are possible.
・ Height adjustment and swivel together with operation panel
Environmental Requirements In Operation:
・ Temperature: +10 to +40 degrees C
・ Relative Humidity: 30 to 75%
(non condensing)
・ Atmospheric pressure: 700 to 1060 hPa

Power Requirement 100 to 120/ 200 to 240V ±10%, 50 or 60 Hz,


Max. 900 VA (with optional recorders connected)
Max. 580 VA (main unit only)
Dimensions 53.3 cm (W) × 74.2 cm (D) × 117.0 - 166.0cm (H)
Weight 85kg or less (main unit only)