Mix Submittal: Design

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

..

GREATER CAIRO METRO LI NE 4 PHASE (1)- NEW CP401

I I • , ,·,., ,.
·I I ' \ 1
I IIlii ; ,
!.
"
• '• o ' ' I~

Mix design Submittal

Submission Number Suppier 3S and Reliance


Conrractor AHPC Date SubmiHed 16-9-2021
Mix Code - 401-3S/ ReUance-37-20-18-A-CEM 111-A-RaftJRoof Sleb-27 C Strength/ grade C37/20

Material Type, Source, QuanUty, Volume and Alkali Conlent


Volume
Constituent Materials Materials Type and Source Kg/m3 S.G(3) Alkali %(4) Kglm3 (4)
m3
Cement CEM Ill - BENI SUEF Cement Company 420 3.15 0.133 0.465 1.465
PFAIGGBS NIA

Note (1) NIA

Note (1) N/A

40 mmAgg. NIA

Crushed rock GcB0/20, 12.5120. (Affaka (Techno


20 mmAgg. 492 2.61 0.189 0.0050 0.019
Gravel)
Crushed rock Gc90115, 4/14, Attaka (Techno
10 mmAgg. 578 2.63 0.220 0.0036 0.016
Gravel)
Sand Natural Sand (Zone C), Ab~Agwa 755 2.61 0..289 0.0210 0.120
Admix.1 Super Plastlclzer, Sikament R4PN 7.5±2 1.22 0.006 4.062 0.284
Admhc.2 NIA

Water Free Water, Potable water 159 1 0.159


Total Water, Potable water 183 1 0.183 0.0003 0.001
Total 2426 A¥(2) 2% Totai Aikan 1.905
Totalm3 1.010

Strength grade of concrete 37 Mpa


AggrvgateiCamantitious ratio by weight 4.345
[WateriCementltlous ratio by weight 0.388 calculate value to 3 decimal places
Design WorkabilitY 175mm±25mm 175 mm ± 25 mm after 2 hours
Compliance Workability Method (a g. Slump, Veba , CF, Skimp
WIC relationship attached Yes
Individual grading details attached Yes
Combined grading detAils attAched Yes
Test Reports of constituent materials attAched Yes
Backup Compressive Strength Date attached Yes
Main Concrete Batchfng Plant which mix Is applied for
Backup Concrete Batchlng Plant 3S /Rel ance and vice Versa

Note (1) use box for any other materials used.


Note (2) Use v.lue 0 .8% unless proved otherwi•e by previous trial.
Note (3) Use S.G. from verified Cest results.
Note (4) calculation of AlkaHcontent (Na20 equivalent) as percentage of material and as kg/m3
Note (5) The mix design proportions are subjected to be adjusted ai !he moisture content in aggregate Increased to achieve 1" or higher.
Note (6) Mix Design Proposal Number (1)