Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

VICINITY MAP:

SPECIFICATION: RISER DIAGRAM: THIS SITE


P electrical work shall comply in
1. All
accordance with whese plans and
specification, the applicable
provisions of the latest edition of ELECTRICAL LAYOUT: LINE TO GROUND 2 / 5.5 mm TW wire
the Philippine electrilcal code SYSTEM
v(PEC) the rules and regulation the SPECIFICATION:
local enforcing authority and the
: 230 volts 60 Htz.
requirements of the local power 1-Phase 2 WIRE
company.
2. All electrical All eiectrical installation
shall be in direct supervision of duiy
lisence lectrical engineer or M
registered master eiectrician.
3. The electrical service power is 1- phase
2 wire,230 VAC, 60 Hz.
4. All materials to be Used shall be
brand new and approved type for 30A
the participation & purpose of usage.
5. The panel board & switches shall be
mounted, wires going & emanating
from these devices shall run
through sureface raceway. 15A 20A
6. All work shall be done in the highest BRGY. NAVALAN, TUKURAN ZDS.
degree of workmanship, proper &
reliable.
7. Grounding system shall be provided 20A SPARE ELECTRICAL SYMBOLS:
to all lighting & power circuits as per
Philippine Electrical Code
requirements.
8. Mounting height of wiring devices --------- PANEL BOARD
shall be as follows:
a. Switch....... 150 cm.
---------- BULB
b. Convenient Outlet ...... 30 cm.

---------- CON. OUTLET

---------- PENLIGHT
LOAD COMPUTATION:
---------- GROUND
CIRCUIT – 1 (Lighting Load) CIRCUIT – 2 (Convenient Outlet)
TOTAL CURRENT 1 (Ckt. 1+ Ckt. 2) ---------- FLOURESCENT LAMP
7 Lighting Outlet @ 70 watts per bulb 5 Con. Outlet x 180
7 x 70 = 490 Watts = 5 x 180 = 900watts = 2.13 + 3.91 S1 ---------- 1 GANG SWITCH
= 490 / 230 volts = 900/ 230 volts = 6.04Ampere
= 2.13 Ampere = 3.91 Ampere S2 ---------- 2 GANG SWITCH

S3 ---------- 3 GANG SWITCH

S3W ---------- 3 WAY SWITCH


SCHEDULE OF LOAD:
---------- HOME RUN
LOAD NO. OF CIRCUIT SIZE OF
CIRCUIT NO. DISCRIPTION OUTLET WATTS CURRENT VOLTS PHASE PROTECTION CONDUCTOR
1 Lighting Outlet 7 490 2.13 230V 1 15A Used 2/ 2.0 mm2
2 Con. Outlet 5 900 3.91 230V 1 20A Used 2/ 3.5 mm2
MAIN 6.04 230V 1 30A Used 2/ 8.0 mm2
4
PREPARED BY: CHECKED BY: SEAL PROJECT TITTLE: CONFORMED BY: SHEET CONTENT SHEET NO.
CABAYARAN,OLIVER M. PRC NO. _________
DATE: ___________ ELECTRICAL WIRING Owner: :
BSEE - 2 PTR No. __________ Mr. & MRS. __________
Mario R. Clamohoy DATE: __________ INSTALLATION
PLACE: __________

You might also like