Metallography Evaluation Report

Report number : LAB-MIC-1920/13462 Date of report : 03-Apr-2019

Report Summary :

Testing performed as per ASTM F2111 & Work instruction IMS-QAD-TP-116, sample evaluated at 100x-500x magnification and found
acceptable. End grain pitting and Intergranular attack none observed.

Test Sample Description:

Customer : Pratt & Whitney Work Order Number : DPrd/1920/13462

Part Name : Bracket, Lifting AFT Part Number : 4506223

Material Specification : AMS 5659 (15-5PH) Sample Qty: 1 no.

Acceptance Specification : ASTM F2111 &


Evaluated Magnification : 100x-500X
Work instruction IMS-QAD-TP-116

Testing Machine Name / Make : Metallurgical Microscope / Nikon Etchant Details : NA

Test Method : ASTM F2111 & ASTM E3 Test condition : As polished condition

METALLOGRAPHY EXAMINATION RESULTS

Sl.no Criteria Reference specification Acceptable limit Actual values Disposition

ASTM F2111 & Work


.
01 *End grain pitting instruction IMS-QAD-TP- None observed Acceptable
Maximum 0.001 inch
116

ASTM F2111 & Work


02 Intergranular attack instruction IMS-QAD-TP- Maximum 0.0002 inch None observed Acceptable
116

Note : (*) Pit definition: A depression or cavity with a width to depth ratio of < 6 to 1

Form No.: IMIM-LAB-F-02 Rev No:01 Date: 04-MAR-2016 Page 1 of 3


INDO-MIM Private Limited (formerly known as INDO-MIM US Tech Private Limited)
45(P), KIADB Industrial Area, Doddaballapur, Bangalore 561203 (CIN U28110KA1996PLC137499)
Phone: +91-080-22048600/ FAX: +91-080-27630532 / Website: www.indo-mim.com

Metallography Evaluation Report

Report number : LAB-MIC-1920/13462 Date of report : 03-Apr-2019

Micro examination images

Image 1 : Image showing Long Transverse (LT) location-1 of part at 500X magnification.

Image 2 : Image showing Long Transverse (LT) location-2 of part at 500X magnification.

Form No.: IMIM-LAB-F-02 Rev No:01 Date: 04-MAR-2016 Page 2 of 3


INDO-MIM Private Limited (formerly known as INDO-MIM US Tech Private Limited)
45(P), KIADB Industrial Area, Doddaballapur, Bangalore 561203 (CIN U28110KA1996PLC137499)
Phone: +91-080-22048600/ FAX: +91-080-27630532 / Website: www.indo-mim.com

Metallography Evaluation Report

Report number : LAB-MIC-1920/13462 Date of report : 03-Apr-2019

Micro examination images

Image 3 : Image showing Short Transverse (ST) location of part at 500X magnification.

Suneel.L - QA- Metallurgical Lab Sanjeev - Lead Metallurgical Lab


Inspected and Prepared by Reviewed and Approved by

Form No.: IMIM-LAB-F-02 Rev No:01 Date: 04-MAR-2016 Page 3 of 3