Professional Documents
Culture Documents
TK Pure 7b Di
TK Pure 7b Di
TK Pure 7b Di
fo
ServiceInformation
.in
BAUKNECHT
Condensation Dryer
TK Pure 7B Di
8560 798 03071
z
Last Modification: 03/20/08
Creation Date: 03/20/08
rvi
ze
SparePartList 2
ExplodedView 4
TechnicalData 6
ps
WiringDiagram 9
CircuitDiagram 11
Testprogram 13
ge
ErrorCodes 14
ServiceBulletin481271340331 15
ServiceBulletin481271340300 16
so
ServiceBulletin481271340313 17
ServiceBulletin481271240301 19
ServiceBulletin481271340317 20
mo
ServiceBulletin481271340336 21
ServiceBulletin481271340324 22
This document is only intended for qualified technicans who are aware of the
w.
fo
SparePartList
Pos 12NC Description
.in
004 0 481244011701 Bottom CD
011 0 481250018054 Foot adjustable
012 0 481252878033 Roll
012 1 481252898003 Shaft Front + Roll
012 2 481252028188 Shaft rear
021 0 481244010819 Front VBL GW
z
022 0 481244010821 Panel side GW
024 0 481244011569 Panel rear
030 0 481244011504 Table top short BK EBL
rvi
053 0 481244011155 Flap EBL WH
053 2 481241728103 Lock transmit. plinth EBL
053 4 481244011171 Plinth EBL WH
053 5 481241728102 Axle f.flap EBL
100 0 481244011705 Door transparent CD WH/BK
131 1 481227138354 Door lock system
ze
133 2 481241728056 Lock Bag filter
191 0 481246668607 Gasket door
204 0 481246638014 Protector
220 0 481241818177 Drum cpl. SS
223 0 481241889017 Drum lifter GW ps
261 0 481241879821 Case f.water cont.
271 0 481235818164 BELT PV 1936 H6
273 0 481235818055 Pulley jokey
275 0 481249268129 Spring
291 0 481246668561 Gasket front
291 2 481246668837 Gasket drum rear
ge
301 0 481245310691 Control panel + handle drawer
303 0 481249878682 Handle drawer galv.
331 0 481241458338 Knob timer
331 3 481241458307 Spring Knob timer
331 4 481241458345 Knob timer ring, silver
332 0 481251318197 Push button options
333 0 481251318196 Push button start
so
fo
Pos 12NC Description
.in
633 1 481227618422 Pin Start reset GW
651 0 481213428056 Lamp drum light cpl.
651 1 481213418052 Lamp drum light
691 0 481225928863 Sensor temper. NTC
691 1 481228298014 Gasket NTC
692 0 481221058055 Bracket Sensor
z
692 1 481227858001 Sensor
692 2 481221058075 Cover Sensor, Kit
rvi
707 9 481253048165 Tube inflow
740 0 481251148417 Heat exchanger H2
741 0 481244008035 Blower cold air
741 1 481253048244 Cover blower house
743 0 481253048683 Air guide w/o Light/old Sensor ho.
743 1 481253049096 Heating chamber SS
ze
743 3 481253048239 Cover blow. house
743 8 481246688519 Gasket f. blow. house
750 0 481241879823 Tank condensw. 4.3l
750 1 481253028856 Water guide
751 1 481241888044 Water collector
751 2 481240118472 Clamp sump cover
751 3
761 0
481227118014
481248058322
Cover water switch
Filter; bag GW
ps
781 0 481253028243 EVACUATION PIPE 1,5 m F I D UK ND SP
783 0 481253008003 Hose inflow bottom
783 1 481253008009 Hose reflow long
783 2 481253008001 Hose Pump bottom
ge
794 0 481246688863 Gasket AC, Bottom
794 1 481246628108 Gasket heater channel
794 4 481246688521 Gasket filter
900 1 481229088053 Clip
900 2 481229088099 Clip for Heater
900 3 481240418529 Crossbar Control panel
so
fo
ExplodedView
.in
z
rvi
ze
ps
ge
so
mo
w.
ww
fo
ExplodedView
.in
z
rvi
ze
ps
ge
so
mo
w.
ww
fo
TechnicalData
Dimensions+Weight
.in
Product dimensions
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 cm
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59.5 cm
Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 cm
Weight
z
net . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 kg
rvi
Electricalbasedata
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V ± 10%
Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Hz
Fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 A
Total connected load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.49 kW
ze
Surroundingstemperature
Room temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 °C
Room temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .min. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 °C
ps
Capacityoflaundry
Cotton . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 kg
Easy care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5 kg
ge
Directdrainingoption
Max. allowable length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5 m
Max. height for drain outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 m
so
Heatingelement
Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V + 10 % / - 15 %
Total power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 x 1300 W ± 5 %
mo
Thermostatscondenser
Caracteristics of the NTC
w.
ww
fo
0 °C 34.6 kΩ
25 °C 11.5 kΩ
.in
60 °C 3.3 kΩ
70 °C 2.4 kΩ
95 °C 1.2 kΩ
100 °C 1.0 kΩ
z
110 °C 0.8 kΩ
130 °C 0.5 kΩ
rvi
180 °C 0.2 kΩ
Safety thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .TL
Switch off temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 °C ± 5 K
ze
Main-andblowermotor
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-phase asynchronous
Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V + 10 % / - 15 %
Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 ± 3 Hz
ps
Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285 W
Resistor (coil)
Main coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (2 - 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Ω
Auxiliary coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (3 - 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Ω
ge
Condensationpump
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-phase synchronous
Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 - 240 V + 10 % / - 15 %
Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Hz
Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (25 °C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450 Ω
so
Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 ± 2 W
Capacity (height 1.1m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.6 l/min
Microswitch
mo
Doorswitch
w.
Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 V
Max. current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA
Controlmodule
ww
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TINY/DOMINO
Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V + 10 % / - 15 %
Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50/60 Hz
fo
Humiditymodule
Nominal voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 V
z .in
rvi
ze
ps
ge
so
mo
w.
ww
fo
WiringDiagram
.in
z
rvi
ze
ps
ge
so
mo
w.
ww
fo
Legend
.in
z
rvi
ze
ps
ge
so
mo
w.
ww
fo
CircuitDiagram
.in
z
rvi
ze
ps
ge
so
mo
w.
ww
fo
Legend
.in
z
rvi
ze
ps
ge
so
mo
w.
ww
fo
Testprogram
.in
z
rvi
ze
ps
ge
so
mo
w.
ww
fo
ErrorCodes
.in
z
rvi
ze
ps
ge
so
mo
w.
ww
fo
ServiceBulletin481271340331
AUTHOR: Kay Augustin
LastUpdate: 03/01/11
.in
VERSION: 1.0
TITLE: Opening of transparent door for Scirocco
SUBJECT: Customer complains about the opening of the transparent door during the cycle
z
REMEDIALACTION
rvi
ze
ps
ge
so
mo
w.
ww
fo
ServiceBulletin481271340300
AUTHOR: Jürgen Reinhardt
LastUpdate: 06/02/08
.in
VERSION: 1.2
TITLE: Insufficient Drying Performance Condensation Drier with dual coil heater 2x1300W, Tiny Domino Controls.
SUBJECT:
z
REMEDIALACTION
rvi
Upgrade of controls in production since week 12/2008. This modification is improving the performance in automatic drying
programs. Please re-program controls with SAM by using the latest data base version 62.
All Tiny controls built before week 40 / 2007 are not programmable by SAM, these controls must be replaced by new
ze
ones.
All concerned spare parts in the warehouse have been replaced by the latest version of controls. Furthermore all the
service 12NC of Tiny controls built before week 40 / 2007 have been substituted as well.
ps
ge
so
mo
w.
ww
fo
ServiceBulletin481271340313
AUTHOR: Juergen Reinhardt
LastUpdate: 07/01/09
.in
VERSION: 1.0
TITLE: Randomly does not start or does stop in programs "SYNTHETIC"or "TIMESTEERED 30min".
SUBJECT: Loose contact in program selector.
Condenser driers and air vented driers produced in week 43, 44, 45, 46 and 48 could be affected by this issue.
z
REMEDIALACTION
rvi
In case of an issue check the production date of the timer according to the pictures below. Only the supplier INVENSIS is
involved in this. The supplier AKO do not have an issue.
ze
ps
ge
so
mo
w.
ww
fo
.in
z
rvi
ze
ps
ge
so
mo
w.
ww
fo
ServiceBulletin481271240301
AUTHOR: Ronny Schurricht
LastUpdate: 10/13/10
.in
VERSION: 1.0
TITLE: Start Delay Indication
SUBJECT: Some customers are claiming that the Start Delay function is not working well. The machine seems to start one
hour earlier than expected. For example, at Start Delay time 3hours the indication is switching from h:03 to h:02 after 1
minute.
z
rvi
REMEDIALACTION
The Start Delay function is working correct.
ze
If the start time is after 3h 00min it’s indicating h:03
If the start time is after 2h 59min it’s indicating h:02
If the start time is after 2h 00min it’s indicating h:02
If the start time is after 1h 59min it’s indicating h:01
If the start time is after 0h 59min it’s indicating :59
ps
If the start time is after 0h 30min it’s indicating :30
ge
so
mo
w.
ww
fo
ServiceBulletin481271340317
AUTHOR: Juergen Reinhardt
LastUpdate: 05/11/10
.in
VERSION: 1.0
TITLE: Reset Procedure for F14 / FE failure
z
REMEDIALACTION
In case of shortage of the heating element or a disturbance due to welding of the heating relay the following RESET proce-
rvi
dure must be always carried out:
Please follow the sequence below which must be performed within 10 seconds:
ze
2) Push "START"button three times
fo
ServiceBulletin481271340336
AUTHOR: Ronny Schuricht
LastUpdate: 07/11/13
.in
VERSION: 1.0
TITLE: 40 or 25 minutes rest time indication
SUBJECT: In a 1h40min. programme the machine runs around 10minutes and then jumps to a resttime indication of 40 or
25 minutes. This doesn’t depend on the amount of laundry inside the machine.
The reason in some cases is due to a residual of fabric softener covering and coating the 2 metal stripes of the humidity
z
sensor. This simulates a rest humidity resulting in 40 or 25 minutes cycle time.
rvi
REMEDIALACTION
Measure the ohmic value between the 2 metal stripes. If the ohmic value is less than 1M ohm exchange the humidity sensor.
ze
ps
ge
so
mo
w.
ww
fo
ServiceBulletin481271340324
AUTHOR: Kay Augustin
LastUpdate: 02/08/11
.in
VERSION: 1.0
TITLE: Fluff accumulation at heat exchanger or heating element
SUBJECT: Additional fluff filter available as service kit
z
REMEDIALACTION
rvi
An additional filter kit, placed at the heat exchanger, is now available.
Delivered with the filter kit will be a detailed Instruction For Use (IFU), see below.
The service code for the filter kit is: 4801 121 01629
ze
ps
ge
so
mo
w.
ww
fo
.in
z
rvi
ze
ps
ge
so
mo
w.
ww